[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100661092":3},{"organization":4,"outcomesModule":7,"designInfo":115,"detailedDescription":121,"studyPopulation":114,"armGroups":122,"interventions":129,"overallOfficials":114,"centralContacts":135,"locations":145,"responsibleParty":163,"collaborators":114,"id":166,"slug":167,"hasResults":168,"nctId":169,"briefTitle":170,"officialTitle":171,"acronym":172,"eligibilityCriteria":173,"healthyVolunteers":168,"sex":174,"minAge":175,"maxAge":114,"enrollmentInfo":176,"targetDuration":114,"studyType":179,"phases":180,"briefSummary":181,"conditions":182,"keywords":114,"overallStatus":188,"whyStopped":114,"lastUpdateSubmitDate":189,"lastUpdatePostDateStruct":190,"startDateStruct":193,"completionDateStruct":195,"leadSponsor":197,"locationsCount":198},{"fullName":5,"class":6},"University of Maryland, Baltimore","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":30,"otherOutcomes":114},[9,13,16,19,23,27],{"measure":10,"description":11,"timeFrame":12},"All-cause mortality","Rate of death from any cause","30 days",{"measure":14,"description":15,"timeFrame":12},"Stroke, excluding transient ischemic attack (TIA)","Rate of stroke",{"measure":17,"description":18,"timeFrame":12},"Early Paralysis, excluding paraparesis","Rate of paralysis",{"measure":20,"description":21,"timeFrame":22},"Technical success","Composite of successful delivery of the device through the vasculature, successful deployment of the device at the intended location, and patient survival","24 hours",{"measure":24,"description":25,"timeFrame":26},"Patency of all graft and endograft components","Graft and endograft patency confirmed by computed tomography (CT) imaging assessment","At hospital discharge or at 1 month",{"measure":28,"description":29,"timeFrame":26},"Complete sealing of the aortic pathology","Absence of Type Ia and IIIa\u002Fb endoleak, complete coverage of penetrating aortic ulcer (PAU) cases, and isolation of the primary entry tear in dissection cases, confirmed by CT imaging assessment",[31,35,38,41,44,47,50,53,56,59,62,65,68,71,74,77,80,83,86,89,92,95,98,101,105,108,111],{"measure":32,"description":33,"timeFrame":34},"Aortic-related death","Rate of aortic-related death","Up to 36 months after the index procedure",{"measure":36,"description":37,"timeFrame":34},"Pseudoaneurysm at the treatment sites","Rate of pseudoaneurysm at the treatment sites",{"measure":39,"description":40,"timeFrame":34},"Unanticipated aortic or branch-related reoperation","Rate of unanticipated aortic or branch-related reoperation",{"measure":42,"description":43,"timeFrame":34},"Late endoleak","Rate of Type I or III endoleak confirmed by computed tomography (CT) imaging assessment",{"measure":45,"description":46,"timeFrame":34},"Non-cardiac\u002Fnon-aortic reoperations","Rate of non-cardiac\u002Fnon-aortic reoperations",{"measure":48,"description":49,"timeFrame":34},"Vocal cord paralysis","Rate of vocal cord paralysis",{"measure":51,"description":52,"timeFrame":34},"Myocardial infarction","Rate of myocardial infarction",{"measure":54,"description":55,"timeFrame":34},"Respiratory failure","Rate of respiratory failure",{"measure":57,"description":58,"timeFrame":34},"Renal failure requiring dialysis","Rate of renal failure requiring dialysis",{"measure":60,"description":61,"timeFrame":34},"Thromboembolic events","Rate of thromboembolic events",{"measure":63,"description":64,"timeFrame":34},"Loss of patency of a graft or endovascular stent graft, including branch grafts","Rate of loss of patency of a graft or endovascular stent graft, including branch grafts",{"measure":66,"description":67,"timeFrame":34},"Secondary unplanned interventions in the treated vascular segment or related to the original pathology","Rate of secondary unplanned interventions in the treated vascular segment or related to the original pathology",{"measure":69,"description":70,"timeFrame":34},"Aortic rupture","Rate of aortic rupture",{"measure":72,"description":73,"timeFrame":34},"Device integrity failures","Rate of device integrity failures confirmed by CT imaging assessment",{"measure":75,"description":76,"timeFrame":34},"Device crimping\u002Fkinking","Rate of device crimping\u002Fkinking confirmed by CT imaging assessment",{"measure":78,"description":79,"timeFrame":34},"Device migration","Rate of device migration (\\>10 mm relative to the implantation position), compared with baseline and confirmed by CT imaging assessment",{"measure":81,"description":82,"timeFrame":34},"Thrombosis of the device lumen","Rate of thrombosis of the device lumen confirmed by CT imaging assessment",{"measure":84,"description":85,"timeFrame":34},"Surgical graft or stent graft infection","Rate of surgical graft or stent graft infection",{"measure":87,"description":88,"timeFrame":34},"Incidence of all endoleak types","Rate of all endoleak types confirmed by CT imaging assessment",{"measure":90,"description":91,"timeFrame":34},"Migration of the distal extension","Rate of distal extension migration (\\>10 mm based on the position of the device implantation) confirmed by CT imaging assessment",{"measure":93,"description":94,"timeFrame":34},"Failure of device-extension integrity resulting in a compromised seal and blood leakage or movement of the device","Rate of extension device integrity issues confirmed by CT imaging assessment",{"measure":96,"description":97,"timeFrame":34},"Incidence of Type III endoleak related to the extension device","Rate of Type III endoleak related to the extension device confirmed by CT imaging assessment",{"measure":99,"description":100,"timeFrame":34},"Incidence of failed patency of the device-extension overlap","Rate of failed patency of the device-extension overlap confirmed by CT imaging assessment",{"measure":102,"description":103,"timeFrame":104},"Incidence of major adverse events (MAE) at 30 days post-extension","Individual rate and type of major adverse events (MAE) at 30 days post-extension","Up to 1 month post-extension",{"measure":106,"description":107,"timeFrame":34},"Incidence of secondary procedures related to the extension","Rate of secondary procedures related to the extension",{"measure":109,"description":110,"timeFrame":34},"Disabling and\u002For non-disabling stroke","Rate of occurrence of disabling and\u002For non-disabling stroke",{"measure":112,"description":113,"timeFrame":34},"Overall incidence of Paralysis and\u002For paraparesis","Rate of paralysis and\u002For paraparesis",null,{"allocation":116,"interventionModel":117,"interventionModelDescription":114,"primaryPurpose":118,"observationalModel":114,"timePerspective":114,"maskingInfo":119},"NA","SINGLE_GROUP","TREATMENT",{"masking":120,"maskingDescription":114,"whoMasked":114},"NONE","Surgical repair of the aortic arch has evolved significantly over the past several decades in response to persistent challenges related to cerebral protection, operative time, and the complex anatomy of the thoracic aorta. The classic elephant trunk technique allowed for a two-stage repair of extensive aortic disease by leaving a free-floating Dacron graft in the descending thoracic aorta to be addressed during a subsequent operation. While foundational, this staged approach was associated with inter-stage mortality and incomplete aortic remodeling.\n\nIn response, the frozen elephant trunk (FET) technique was developed to allow simultaneous treatment of the arch and descending thoracic aorta in a single-stage procedure. By combining an open surgical Dacron graft proximally with a distal stented endograft component (deployed antegrade into the descending aorta), FET became a transformative hybrid approach. However, FET techniques remain technically demanding, particularly when managing supra-aortic branch reimplantation, maintaining cerebral perfusion, and reducing circulatory arrest time. To address these issues, newer procedural refinements have emerged, including the Branched Stented Anastomosis Frozen Elephant Trunk Repair (B-SAFER) technique.\n\nThe B-SAFER technique entails deploying the endograft with a proximal landing zone in zone 1 or 2 of the aortic arch, in situ fenestration of the graft and insertion of branch stent grafts in one or more of the supra-aortic branch vessels via the fenestration. A surgical Dacron graft is then sewn to incorporate the distal aorta and the aortic endograft. This technique has had promising early results and is currently under investigation with an ongoing physician-sponsored investigational device exemption study at the Cleveland Clinic.\n\nSubsequently, hybrid FET devices such as the Thoraflex Hybrid (Terumo Aortic) and E-vita Open Plus (Jotec) have become widely used internationally. These devices incorporate a surgical aortic graft and an endograft together to obviate the need for surgeons to sew the two together, such as in the B-SAFER technique. This can lead to a significant reduction in circulatory arrest time. However, the stenting of supra-aortic vessels with hybrid FET devices has not been routinely performed, or systematically evaluated, as direct access to the endograft proves more challenging than with the B-SAFER technique, where a separate endograft and surgical aortic graft are used. The investigators introduce a novel modification of a hybrid FET device that enables supra-aortic vessel stenting. This technique involves a wire-reinforced fenestration made on the endograft portion of the hybrid FET device that is pre-wired. A branch stent graft is then delivered through this fenestration and allows for supra-aortic vessel stenting. One of the key advantages of this modification is the improvement in seal between the branch stents and the endograft. The wire-reinforcement prevents tearing of the endograft which can lead to early endoleak, as seen in 7% or more of B-SAFER patients. In addition, this technique can allow for direct suture fixation of the branch stent to the wire-reinforced fenestration preventing migration of the components and further improving seal.",[123],{"label":124,"type":125,"description":126,"interventionNames":127},"Supra-aortic frozen elephant trunk (SA-FET)","EXPERIMENTAL","Patients undergoing aortic replacement using the novel modified SA-FET technique.",[128],"Device: Modified Supra-Aortic Frozen Elephant Trunk (SA-FET) Device",[130],{"type":131,"name":132,"description":133,"armGroupLabels":134,"otherNames":114},"DEVICE","Modified Supra-Aortic Frozen Elephant Trunk (SA-FET) Device","The proposed SA-FET procedure consists of a hybrid frozen elephant trunk (FET) device (Thoraflex, Terumo) with up to three reinforced fenestrations on the proximal endograft segment. Each fenestration is sized from 4 to 13 millimeters (mm) based on the size of the targeted supra-aortic vessel and wire-reinforced circumferentially using continuous watertight anastomosis-type suturing with polyester suture, as is done in commercially available fenestrated aortic endografts. The reinforcement provides an anchoring point against the radial force of the branch stents to maintain a seal and prevent tearing of the aortic endograft, and also provides a radiopaque marker. The fenestration is then pre-wired to allow delivery of a branch stent graft (Gore Viabahn). After deployment of the fenestrated graft, the supra-aortic branch stent grafts are deployed. The branch stent may be additionally secured to the fenestration using interrupted or continuous suturing with polypropylene suture.",[124],[136,141],{"name":137,"role":138,"phone":139,"phoneExt":114,"email":140},"Aakash Shah, MD","CONTACT","3013353253","aakash.shah@som.umaryland.edu",{"name":142,"role":138,"phone":143,"phoneExt":114,"email":144},"Kaitlyn Masih, BSN","410-328-4562","kmasih@som.umaryland.edu",[146],{"facility":147,"status":114,"city":148,"state":149,"zip":150,"country":151,"countryCode":152,"cosmosGeoPoint":153,"geoPoint":158,"contacts":159},"University of Maryland Medical Center","Baltimore","Maryland","21201","United States","US",{"type":154,"coordinates":155},"Point",[156,157],-76.61219,39.29038,{"lat":157,"lon":156},[160,161],{"name":142,"role":138,"phone":143,"phoneExt":114,"email":144},{"name":137,"role":162,"phone":114,"phoneExt":114,"email":114},"PRINCIPAL_INVESTIGATOR",{"type":162,"investigatorFullName":164,"investigatorTitle":165,"investigatorAffiliation":5,"oldNameTitle":114,"oldOrganization":114},"Aakash Shah","Associate Professor","100661092","a-novel-wire-reinforced-fenestration-of-a-hybrid-frozen-elephant-trunk-device-for-supra-aortic-branch-vessel-stenting-during-aortic-arch-replacement-100661092",false,"NCT07885865","A Novel Wire-Reinforced Fenestration of a Hybrid Frozen Elephant Trunk Device for Supra-Aortic Branch Vessel Stenting During Aortic Arch Replacement","Supra-Aortic Branch Vessel Stenting With a Hybrid Frozen Elephant Trunk Device: A Novel Wire-Reinforced Fenestration Technique","SA-FET","Inclusion Criteria:\n\n1. Age 18 years or older.\n2. Willing and able to give written informed consent, or the patient's legally authorized representative has given written informed consent.\n3. Expected life expectancy of more than two years after repair.\n4. Aortic pathology requiring repair or replacement of multiple damaged or diseased segments of the thoracic aorta, with at least one of the following: (a) thoracic aortic aneurysm at increased risk for rupture or complications; (b) acute aortic dissection requiring urgent repair; (c) aortic pseudoaneurysm at risk for rupture or complications; (d) penetrating aortic ulcer (PAU) at risk for rupture or complications; (e) congenital aortic disease requiring repair.\n\nExclusion Criteria:\n\n1. Unfit for open surgical repair involving circulatory arrest.\n2. Comatose or suffering from irreversible severe brain malperfusion.\n3. Known sensitivity to components of the devices.\n4. Active systemic infection that, in the opinion of the investigator, would compromise the outcome of the surgical procedure.\n5. Currently participating in an investigational drug or another device study within 6 months before the date of implant, or has not reached the primary endpoint of that study.\n6. Eligible for treatment with a U.S. Food and Drug Administration (FDA)-approved marketed device.\n7. Willing and eligible for enrollment in a manufacturer-sponsored clinical study at any institution.\n8. Willing and eligible to participate in a study with a manufacturer-made device at any institution.\n9. Uncorrectable bleeding anomaly.\n10. Pregnant.\n11. Other medical, social, or psychological conditions that, in the opinion of the investigator, preclude appropriate consent or adherence to the follow-up examinations required by the protocol.","ALL","18 Years",{"count":177,"type":178},100,"ESTIMATED","INTERVENTIONAL",[116],"The goal of this prospective, non-randomized trial is to determine the safety and technical success of a novel modification to a U.S. Food and Drug Administration (FDA)-approved hybrid frozen elephant trunk (FET) device (Thoraflex Hybrid, Terumo Aortic). The modification is intended to enable supra-aortic vessel stenting in patients undergoing aortic arch replacement for aortic aneurysm or dissection.",[183,184,185,186,187],"Aortic Aneurysm","Aortic Dissection","Penetrating Aortic Ulcer (PAU)","Aortic Pseudoaneurysm","Aortic Arch Replacement","NOT_YET_RECRUITING","2026-10-13",{"date":191,"type":192},"2026-10-21","ACTUAL",{"date":194,"type":178},"2026-11-01",{"date":196,"type":178},"2032-12-31",{"name":5,"class":6},1]