[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100662461":3},{"organization":4,"outcomesModule":7,"designInfo":58,"detailedDescription":59,"studyPopulation":62,"armGroups":63,"interventions":71,"overallOfficials":77,"centralContacts":81,"locations":90,"responsibleParty":113,"collaborators":115,"id":119,"slug":120,"hasResults":121,"nctId":122,"briefTitle":123,"officialTitle":124,"acronym":59,"eligibilityCriteria":125,"healthyVolunteers":121,"sex":126,"minAge":127,"maxAge":59,"enrollmentInfo":128,"targetDuration":59,"studyType":131,"phases":59,"briefSummary":132,"conditions":133,"keywords":59,"overallStatus":93,"whyStopped":59,"lastUpdateSubmitDate":135,"lastUpdatePostDateStruct":136,"startDateStruct":139,"completionDateStruct":141,"leadSponsor":143,"locationsCount":144},{"fullName":5,"class":6},"Mayo Clinic","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":19,"otherOutcomes":29},[9,13,16],{"measure":10,"description":11,"timeFrame":12},"Percentage of accurate post ablation outcome predictions Percentage of Accurate Post-Ablation Outcome Predictions","The ACORYS-AI4AF model will use non-invasive mapping data collected during standard clinical procedures to predict post-ablation outcomes. Accuracy will be reported as the percentage of predictions that correctly correspond with the observed post-ablation outcome.","12 Months",{"measure":14,"description":15,"timeFrame":12},"Number of Patients to remain arrhythmia-free after pulmonary vein isolation (PVI) alone","Freedom from atrial fibrillation, atrial tachycardia, or atrial flutter lasting longer than 30 seconds, with or without symptoms, after a single ablation procedure (excluding episodes within the first 6 weeks post-procedure). This will be Measured through any of the following per standard of care procedures: 12-lead ECG, ambulatory rhythm monitoring devices, Consumer-facing wearable ECG devices (e.g., AliveCor KardiaMobile 6L, Apple Watch, etc), and Cardiac implanted electronic devices (implanted loop recorders, pacemakers, defibrillators).",{"measure":17,"description":18,"timeFrame":12},"Number of Patients not remaining arrhythmia-free after pulmonary vein isolation (PVI) and requiring additional atrial substrate ablation.","Freedom from atrial fibrillation, atrial tachycardia, or atrial flutter lasting longer than 30 seconds, with or without symptoms, after a single ablation procedure (excluding episodes within the first 6 weeks post-procedure). This will be Measured by the number of patients to undergo a second atrial substrate ablation post procedure.",[20,23,26],{"measure":21,"description":22,"timeFrame":12},"Percentage of patients with identified critical atrial regions contributing to arrhythmia maintenance for whom post-ablation outcomes were accurately predicted","Percentage of patients with identified critical atrial regions contributing to arrhythmia maintenance whose observed post-ablation outcome matched the outcome predicted based on the identified regions. Prediction accuracy is calculated as the proportion of correct predictions among all evaluated patients.",{"measure":24,"description":25,"timeFrame":12},"Accuracy of Imageless Electrocardiographic Imaging (ECGI) in Identifying Arrhythmogenic Substrates","The accuracy of Imageless Electrocardiographic Imaging (ECGI) in identifying arrhythmogenic substrates will be assessed by comparison with conventional electroanatomical mapping. Accuracy will be reported as the percentage of ECGI findings that correspond with findings from conventional electroanatomical mapping.",{"measure":27,"description":28,"timeFrame":12},"Percentage of procedures with successful mapping completed","Percentage of procedures with successful mapping completed will be determined by the findings that correspond with findings from conventional electroanatomical mapping.",[30,34,37,40,43,46,49,52,55],{"measure":31,"description":32,"timeFrame":33},"Number of Participants With Atrial Fibrillation Termination to Sinus Rhythm","Number of participants with atrial fibrillation during the index catheter ablation procedure whose rhythm terminates to sinus rhythm during the procedure.","Baseline",{"measure":35,"description":36,"timeFrame":33},"Number of Participants With Atrial Fibrillation Conversion to Atrial Flutter","Number of participants with atrial fibrillation during the index catheter ablation procedure whose rhythm converts to atrial flutter during the procedure.",{"measure":38,"description":39,"timeFrame":33},"Radiation Exposure Time","Duration of radiation exposure during the index catheter ablation procedure, reported in minutes.",{"measure":41,"description":42,"timeFrame":33},"Total duration of index catheter ablation procedure","Total duration of the index catheter ablation procedure measured in minutes",{"measure":44,"description":45,"timeFrame":33},"Duration of ablation during procedure","Total ablation time during the index catheter ablation procedure, reported in minutes.",{"measure":47,"description":48,"timeFrame":12},"Number of participants with procedural complications","Number of participants experiencing at least one complication associated with the index catheter ablation procedure",{"measure":50,"description":51,"timeFrame":12},"Number of serious adverse events","The number of serious adverse events (SAEs), including unanticipated adverse device effects, will be measured as the total number of events reported during the study.",{"measure":53,"description":54,"timeFrame":12},"Number of device failures","The number of device failures, including device malfunctions, will be measured as the total number of events reported throughout the study.",{"measure":56,"description":57,"timeFrame":12},"Number of skin irritation reactions","The number of skin irritation reactions will be measured as the total number of events reported throughout the study.",{"allocation":59,"interventionModel":59,"interventionModelDescription":59,"primaryPurpose":59,"observationalModel":60,"timePerspective":61,"maskingInfo":59},null,"COHORT","PROSPECTIVE","Patients diagnosed with atrial arrhythmia and referred for catheter ablation procedure.",[64,68],{"label":65,"type":59,"description":59,"interventionNames":66},"PVI (Pulmonary veins isolation)-Only",[67],"Device: Acorys Mapping System",{"label":69,"type":59,"description":59,"interventionNames":70},"PVI (Pulmonary veins isolation) +",[67],[72],{"type":73,"name":74,"description":75,"armGroupLabels":76,"otherNames":59},"DEVICE","Acorys Mapping System","Acorys Mapping System is a non-invasive cardiac mapping system to be used as part of the electrophysiology procedure",[69,65],[78],{"name":79,"affiliation":5,"role":80},"Konstantinos Siontis, M.D","PRINCIPAL_INVESTIGATOR",[82,87],{"name":83,"role":84,"phone":85,"phoneExt":59,"email":86},"Brooke Stanga","CONTACT","507-422-6692","stanga.brooke@mayo.edu",{"name":88,"role":84,"phone":59,"phoneExt":59,"email":89},"Konstantinos Siontis","Siontis.Konstantinos@mayo.edu",[91],{"facility":92,"status":93,"city":94,"state":95,"zip":96,"country":97,"countryCode":98,"cosmosGeoPoint":99,"geoPoint":104,"contacts":105},"Mayo Clinic in Rochester","RECRUITING","Rochester","Minnesota","55905","United States","US",{"type":100,"coordinates":101},"Point",[102,103],-92.4699,44.02163,{"lat":103,"lon":102},[106,109,112],{"name":107,"role":84,"phone":108,"phoneExt":59,"email":59},"Heart Rhythm Services Research Team","(507) 255-0774",{"name":110,"role":84,"phone":111,"phoneExt":59,"email":89},"Konstantinos Siontis, MD","(507) 255-1051",{"name":110,"role":80,"phone":59,"phoneExt":59,"email":59},{"type":80,"investigatorFullName":88,"investigatorTitle":114,"investigatorAffiliation":5,"oldNameTitle":59,"oldOrganization":59},"Principal Investigator",[116],{"name":117,"class":118},"Corify Care","UNKNOWN","100662461","acorys-ai4af-pilot-study-100662461",false,"NCT07904377","ACORYS AI4AF PILOT STUDY","Pilot Observational Study for the Development of an Artificial Intelligence-Driven Methodology to Identify Optimal Atrial Ablation Strategies Using Non-Invasive Electrocardiographic Imaging (ACORYS-AI4AF Pilot Study)","Inclusion Criteria\n\n* Age ≥ 18 years old\n* Diagnosis of paroxysmal AF, persistent (including longstanding) AF or atrial flutter\n\n  o Definition of persistent AF per the 2023 AHA\u002FACC\u002FHRS Guidelines: AF that is continuous and sustains for \\>7 d and requires intervention. Of note, patients with persistent AF who, with therapy, become paroxysmal should still be defined as persistent.\n* Clinical indication for catheter ablation per SOC.\n* Demonstrated willingness and ability to adhere to the study protocol, including provision of written informed consent\n\nExclusion Criteria\n\n* Age \\\u003C18 years old\n* Pregnancy or lactation\n* Contraindications for catheter ablation\n* Prior surgical\u002FConvergent Ablation\n* 2 or more prior PVIs\n* Typical atrial flutter as the only clinical arrhythmia (anticipated cavotricuspid isthmus ablation only)\n* Contraindications to use of the ACORYS Mapping System, such as open wounds, skin conditions, or known material sensitivities, including sensitivities to acrylic adhesives or silver\n* Participation in another clinical trial that would interfere with study outcome","ALL","18 Years",{"count":129,"type":130},200,"ESTIMATED","OBSERVATIONAL","This is a Pilot Observational Study designed to record atrial electrophysiological activity in patients with atrial arrhythmias using non-invasive mapping technology. The primary objective is to develop and evaluate the capacity of novel artificial intelligence models (i.e. ACORYS-AI4AF model) to predict post-ablation outcomes based on the data obtained from non-invasive mapping.",[134],"Atrial Arrhythmia","2026-10-23",{"date":137,"type":138},"2026-10-29","ACTUAL",{"date":140,"type":138},"2026-01-28",{"date":142,"type":130},"2028-12",{"name":5,"class":6},1]