[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100663112":3},{"organization":4,"outcomesModule":7,"designInfo":64,"detailedDescription":71,"studyPopulation":11,"armGroups":72,"interventions":77,"overallOfficials":82,"centralContacts":87,"locations":11,"responsibleParty":97,"collaborators":99,"id":102,"slug":103,"hasResults":104,"nctId":105,"briefTitle":106,"officialTitle":107,"acronym":108,"eligibilityCriteria":109,"healthyVolunteers":104,"sex":110,"minAge":111,"maxAge":11,"enrollmentInfo":112,"targetDuration":11,"studyType":115,"phases":116,"briefSummary":117,"conditions":118,"keywords":122,"overallStatus":127,"whyStopped":11,"lastUpdateSubmitDate":128,"lastUpdatePostDateStruct":129,"startDateStruct":132,"completionDateStruct":134,"leadSponsor":136,"locationsCount":11},{"fullName":5,"class":6},"Advanced MedTech Solutions Pvt. Ltd.","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":40},[9],{"measure":10,"description":11,"timeFrame":12},"Major adverse cardiac events (MACE) - defined as composite of cardiovascular death, non-fatal myocardial infarction (MI), and clinically driven target vessel revascularization (CD-TVR)",null,"180 days",[14,17,20,23,26,30,34,37],{"measure":15,"description":11,"timeFrame":16},"Incidence of Major Advance Cardiac Events 1. Cardiac Death 2. Non- fatal Myocardial Infarction 3. Clinically driven Target Vessel Revascularization","30 and 360 days",{"measure":18,"description":11,"timeFrame":19},"Clinically driven target lesion revascularization (CD-TLR)","30, 180 and 360 days",{"measure":21,"description":22,"timeFrame":19},"Target vessel failure (TVF)","a composite of Cardiovascular (CV) death, TV-MI and CD-TVR, and individual components of composite end points",{"measure":24,"description":11,"timeFrame":25},"Non-Target Vessel related Myocardial Infarction","30, 180, and 360 days",{"measure":27,"description":28,"timeFrame":29},"Stent thrombosis","Stent thrombosis as per\n\n1. Academic Research Consortium \\[ARC\\] 2 Evidence definitions - Definite and probable.\n2. As per latency - Acute (0-24 hours), Subacute (24 hours- 30 days) and late (30-365 days)","0-24 hours, 24 hours-30 days and late 30-365 days",{"measure":31,"description":32,"timeFrame":33},"Device success","Defined as achievement of a final residual stenosis of \\\u003C20%, Successful deployment of stent with complete retrieval of delivery system without coronary dissection, device deformation \\& visible mal apposition on fluoroscopy with stent boost","0 hour, 24 hours, 3 days",{"measure":35,"description":36,"timeFrame":33},"Procedural Success","Defined as achievement of a final diameter stenosis of \\\u003C 20%(site reported) using any PCI method, without the occurrence of death, MI, or repeat target vessel revascularization during hospital stay.",{"measure":38,"description":39,"timeFrame":33},"Lesion success","Defined as achievement of \\\u003C 20% residual stenosis using any percutaneous method.",[41,45,47,49,51,54,56,58,60,62],{"measure":42,"description":43,"timeFrame":44},"QCA Endpoints","Late Lumen Loss","0 and 180 days",{"measure":42,"description":46,"timeFrame":44},"Angiographic binary restenosis",{"measure":42,"description":48,"timeFrame":44},"In-stent and in-segment minimum lumen diameter (MLD)",{"measure":42,"description":50,"timeFrame":44},"In-stent and in-segment % diameter stenosis (DS)",{"measure":52,"description":53,"timeFrame":44},"OCT Endpoints","Minimal Lumen Area (MLA)",{"measure":52,"description":55,"timeFrame":44},"Late lumen loss (LLL)",{"measure":52,"description":57,"timeFrame":44},"Percentage area stenosis",{"measure":52,"description":59,"timeFrame":44},"Neointimal hyperplasia",{"measure":52,"description":61,"timeFrame":44},"proportion of in stent and in segment binary restenosis",{"measure":52,"description":63,"timeFrame":44},"Proportion of struts uncovered and malapposed",{"allocation":65,"interventionModel":66,"interventionModelDescription":67,"primaryPurpose":68,"observationalModel":11,"timePerspective":11,"maskingInfo":69},"NA","SINGLE_GROUP","Pilot Study (Open Label)","TREATMENT",{"masking":70,"maskingDescription":11,"whoMasked":11},"NONE","A prospective, global, multi-centre, single-arm clinical study to evaluate the Safety and Performance of ADVA ACE Everolimus eluting Coronary Stent System in Coronary Artery Disease in Indian \\& European population. (ADVANCE)\n\nA QCA Analysis will be performed on all 70 patients in Indian population \\& OCT for only 10 Indian patients at baseline visit and at 6-month follow up visit.\n\nInterval (Days) for patients visit at Day 0, Day 30±14, Day 180±14 and Day 360±14.\n\nSample size distribution:\n\nOf the 110, 40 patients will be assigned to European population, and 70 patients will be assigned to Indian population.\n\nPrimary Objective:\n\nTo evaluate the performance of Adva ACE Everolimus Eluting Stent assessed by Major Adverse Cardiac Events (MACE) a composite of cardiovascular death, non-fatal Myocardial Infarction (MI) and Clinically driven Target Vessel Revascularization (CD-TVR) at 180 days.\n\nSecondary Objectives:\n\nTo estimate patient safety and performance through incidence of Major Adverse Cardiac Events (MACE) at 30 and 360 days, clinically driven target lesion revascularization (CD-TLR), Target vessel failure (TVF) a composite of cardiovascular death, Target Vessel Myocardial Infarction (TV-MI) and Clinically driven Target Vessel Revascularization (CD-TVR), Stent thrombosis and individual components of composite endpoints at 30, 180 and 360 days.\n\nTo estimate device and procedure success of Adva ACE Everolimus Eluting stent on the device and procedure.\n\nTo estimate angiographic (QCA) and OCT parameters of performance of Adva ACE Everolimus eluting stent as defined by Late lumen loss and percentage diameter stenosis at 180 days (For India Only).\n\nExploratory objectives: None\n\nStent is approved for manufacturing and marketing in India.",[73],{"label":74,"type":6,"description":11,"interventionNames":75},"ADVA ACE Everolimus Eluting Coronary Stent System",[76],"Device: ADVA ACE Everolimus Eluting Coronary Stent System",[78],{"type":79,"name":74,"description":80,"armGroupLabels":81,"otherNames":11},"DEVICE","ADVA ACE - Everolimus Eluting Coronary Stent System is a device\u002Fdrug combination product comprised of two regulated components: a device (coronary stent system) and a drug product (a formulation of Everolimus contained in a biodegradable polymer coating). is uniquely designed with a low polymer load, abluminal coating and bioabsorbable polymer matrix which may reduce the risk of thrombosis and the need for prolonged dual antiplatelet therapy.",[74],[83],{"name":84,"affiliation":85,"role":86},"Dr. Upendra Kaul, M.B.B.S., M.D, D.M Cardiology","Batra Hospital & Medical Research Centre, New Delhi-110062","PRINCIPAL_INVESTIGATOR",[88,93],{"name":89,"role":90,"phone":91,"phoneExt":11,"email":92},"Sudipt Chakraborty","CONTACT","+91 9211465538","schakraborty@amsltd.com",{"name":94,"role":90,"phone":95,"phoneExt":11,"email":96},"Dr. Priyadarshini Arambam","+91 9910990347","regulatory@clicebo.com",{"type":98,"investigatorFullName":11,"investigatorTitle":11,"investigatorAffiliation":11,"oldNameTitle":11,"oldOrganization":11},"SPONSOR",[100],{"name":101,"class":6},"Clicebo Solutions Private Limited","100663112","adva-ace-coronary-stent-system-in-coronary-artery-disease-patients-advance-100663112",false,"NCT07912541","ADVA ACE Coronary Stent System in Coronary Artery Disease Patients (ADVANCE)","A Prospective, Global, Multi-centre, Single-arm Clinical Study to Evaluate the Safety and Performance of ADVA ACE Everolimus elutiNg Coronary Stent System in Coronary Artery Disease in Indian & European Population (ADVANCE)","ADVANCE","Inclusion Criteria:\n\n1. Age ≥18 years\n2. Gender: All (Males, Females, Transgenders, Non-binary)\n3. ICF: Patient or legally authorized representative (LAR) agrees to participate by signing the informed consent form.\n4. Patient with coronary artery disease eligible for percutaneous coronary intervention (PCI) as per current ESC \u002F AHA\u002F WCC or hospital's approved guidelines.\n5. Patient with coronary artery disease having de novo lesion in native coronary arteries with a visually estimated diameter stenosis ≥50 %.\n6. Patients with Reference vessel diameter of 2.25 to 4.5 mm.\n7. Patients with lesion length ≤36 mm.\n\nExclusion Criteria:\n\n1. Pregnant and\u002For lactating females.\n2. Patients under judicial protection, tutorship, curatorship, imprisonment etc (for Europe only).\n3. Patients requiring staged procedure.\n4. Known congestive heart failure (NYHA IV) or left ventricular ejection fraction (LVEF) \\\u003C30%.\n5. Patients with known hypersensitivity or allergies to aspirin, heparin, clopidogrel, ticlopidine, Everolimus or similar drugs, or any other analogue or derivative, cobalt, chromium, nickel, molybdenum or contrast media.\n6. Current medical condition with a life expectancy of less than 12 months.\n7. Diagnosis: Acute Myocardial Infarction within 72 hours of Planned Index procedure.\n8. Patient has current unstable arrhythmias.\n9. Patients previously treated with PCI or CABG for any coronary artery lesion revascularization.\n10. Patients with Chronic Total Occlusion or In-Stent Restenosis lesion.\n11. Patients with Ostial Lesions (within 5.0mm of vessel origin).\n12. Patients with Bifurcation lesions that include a side branch \\>2.0 mm diameter.\n13. Unprotected Left Main Coronary Artery lesion.\n14. Heavily calcified lesion and\u002For calcified lesion which cannot be successfully predilated in opinion of the treating cardiologist.\n15. Patients with Cardiogenic shock, systemic bleeding and coagulation disorders, intracranial bleeding, Renal insufficiency requiring dialysis, Acute or chronic renal dysfunction (serum creatinine \\>2.0mg\u002Fdl or 150 µmol\u002FL), peripheral vascular diseases, cancer, etc. and patients who are planning to undergo surgery within 1 year of the index procedure.\n16. Patients with platelet count \\\u003C100.000 cells\u002Fmm3 or \\>700.000 cells\u002Fmm3 or a WBC\\\u003C3.000 cells\u002Fmm3.\n17. Currently participating in another clinical trial.","ALL","18 Years",{"count":113,"type":114},110,"ESTIMATED","INTERVENTIONAL",[65],"A prospective, global, multi-centre, single-arm clinical study to evaluate the Safety and Performance of ADVA ACE Everolimus eluting Coronary Stent System in Coronary Artery Disease in Indian \\& European population.\n\nTo evaluate the performance of ADVA ACE Everolimus Eluting Stent, follow up indicated by MACE at 6 months.\n\nOf the 110, 40 patients will be assigned to European population, and 70 patients will be assigned to Indian population. QCA is applicable to all Indian patients while OCT applicable for 10 Indian patients only at baseline and 6-months follow-up visit.\n\nA QCA Analysis will be performed on all 70 patients in Indian population \\& 10 Indian patients only.\n\nInterval (Days) for patients visit at Day 0, Day 30±14, Day 180±14 and Day 360±14.",[119,120,121],"Coronary Artery Disease","De Novo Stenosis Lesion","Coronary Stent Implantation",[74,43,123,124,125,126],"QCA","OCT","percutaneous coronary intervention","Advanced Medtech Solutions","NOT_YET_RECRUITING","2026-10-30",{"date":130,"type":131},"2026-11-03","ACTUAL",{"date":133,"type":114},"2026-11",{"date":135,"type":114},"2029-05",{"name":5,"class":6}]