[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100539163":3},{"organization":4,"outcomesModule":7,"designInfo":53,"detailedDescription":61,"studyPopulation":58,"armGroups":62,"interventions":68,"overallOfficials":73,"centralContacts":78,"locations":58,"responsibleParty":88,"collaborators":58,"id":90,"slug":91,"hasResults":92,"nctId":93,"briefTitle":94,"officialTitle":95,"acronym":96,"eligibilityCriteria":97,"healthyVolunteers":92,"sex":98,"minAge":99,"maxAge":58,"enrollmentInfo":100,"targetDuration":58,"studyType":103,"phases":104,"briefSummary":105,"conditions":106,"keywords":110,"overallStatus":115,"whyStopped":58,"lastUpdateSubmitDate":116,"lastUpdatePostDateStruct":117,"startDateStruct":120,"completionDateStruct":122,"leadSponsor":124,"locationsCount":58},{"fullName":5,"class":6},"Advanced MedTech Solutions Pvt. Ltd.","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":44},[9],{"measure":10,"description":11,"timeFrame":12},"Composite Endpoint","MACE (Hierarchical incidence of Cardiovascular Death, Myocardial infarction or Target Vessel Revascularization)","1 Year",[14,18,21,25,27,29,33,37,41],{"measure":15,"description":16,"timeFrame":17},"Incidence of DOCE","1. Cardiovascular Death\n2. Myocardial infarction in the territory of Target vessel\n3. Clinically driven target lesion revascularization","30 Days, 180 Days, 270 Days and 360 days",{"measure":19,"description":20,"timeFrame":17},"Incidence of POCE","1. All cause death\n2. Any Stroke\n3. Any myocardial infarction\n4. Any revascularization",{"measure":22,"description":23,"timeFrame":24},"Incidence of MACE","1. Cardiovascular Death\n2. Non-fatal MI\n3. Target Vessel Revascularization","30 Days, 180 Days and 360 days",{"measure":26,"description":26,"timeFrame":17},"Target vessel failure (TVF)",{"measure":28,"description":28,"timeFrame":17},"Non-Target Vessel related Myocardial Infarction",{"measure":30,"description":31,"timeFrame":32},"Stent thrombosis","Stent thrombosis as per\n\n1. Academic Research Consortium \\[ARC\\] Evidence definitions - Definite and probable\n2. As per latency - Acute (0-24 hours), Subacute (24 hours-30 days) and late (30-365 days)","0-24 hours, 24 hours-30 days and late 30-365 days",{"measure":34,"description":35,"timeFrame":36},"Device success","* Residual coronary stenosis less than 20%\n* Normal coronary flow and absence of coronary dissections \\> C\n* Procedural and absence of PCI complications including periprocedural MI, coronary perforation, urgent CABG or death or revascularization within 3 days of Index procedure","0 hour, 24 hours, 3 days",{"measure":38,"description":39,"timeFrame":40},"Procedural Success","* Residual Stenosis less than 20%\n* Successful reperfusion of Target vessel region with TIMI Flow ≥ 2","24 Hours",{"measure":42,"description":43,"timeFrame":40},"Acute Device Success","Acute Device Success as defined by Residual Stenosis ≤ 20%",[45,49,51],{"measure":46,"description":47,"timeFrame":48},"For QCA Group","• Late Lumen Loss","270 Days",{"measure":46,"description":50,"timeFrame":48},"• Angiographic binary restenosis",{"measure":46,"description":52,"timeFrame":48},"• In-stent and in-segment minimum lumen diameter (MLD) and % diameter stenosis (DS)",{"allocation":54,"interventionModel":55,"interventionModelDescription":56,"primaryPurpose":57,"observationalModel":58,"timePerspective":58,"maskingInfo":59},"NA","SINGLE_GROUP","Pilot Study (Open Label)","TREATMENT",null,{"masking":60,"maskingDescription":58,"whoMasked":58},"NONE","A Prospective, Multicentre, Pilot Study to Evaluate the Safety and Performance of the AdvaPro Sirolimus Eluting Coronary Stent System in Coronary Artery Stenosis in Indian and European Population(RESTORE).\n\nA QCA Analysis will be performed on minimum 48 patients in Indian population only at baseline visit and 9 month follow-up.\n\nInterval(Days) for patients visit at Day 0, Day 30±7, Day 180±8, Day 270±10 and Day 360±14.\n\nSample size distribution:\n\nOf the 120, 40 patients will be assigned to European population and 80 patients will be assigned to Indian population.\n\nPrimary Objective:\n\nTo evaluate the performance of AdvaPro Sirolimus Eluting Stent follow up indicated by MACE at 9 months.\n\nSecondary Objectives:\n\nTo estimate patient safety and performance through incidence of Major Adverse Cardiac Events (MACE) at 30, 180, 360 days and device oriented composite end point (DOCE), patient oriented composite end point (POCE) Stent Thrombosis, Target vessel failure (TVF), Target Vessel related Myocardial Infarction (TV-MI), and individual components of composite end points at 30, 180, 270 and 360 days after use of AdvaPro Sirolimus Eluting Stent.\n\nTo estimate device and procedure success at 30, 180, 270 and 360 days after use of AdvaPro Sirolimus Eluting Stent.\n\nTo Estimate Definitive parameters of performance of AdvaPro Sirolimus Eluting Stent as defined by Late Lumen Loss and Diameter Stenosis percentage at 270 days of AdvaPro Sirolimus Eluting Stent.\n\nExploratory objectives: None\n\nStent is approved for manufacturing and marketing in India.",[63],{"label":64,"type":6,"description":65,"interventionNames":66},"Interventional","AdvaPro Sirolimus Eluting Coronary Stent System",[67],"Device: AdvaPro Sirolimus Eluting Coronary Stent System",[69],{"type":70,"name":65,"description":71,"armGroupLabels":72,"otherNames":58},"DEVICE","Cardiac Stent",[64],[74],{"name":75,"affiliation":76,"role":77},"Dr Philippe Garot","Hôpital Privé Jacques Cartier, Massy","PRINCIPAL_INVESTIGATOR",[79,84],{"name":80,"role":81,"phone":82,"phoneExt":58,"email":83},"Dr Jayesh Jani","CONTACT","8130009876","jjani@amsltd.com",{"name":85,"role":81,"phone":86,"phoneExt":58,"email":87},"Priyadarshini Arambam","9910990347","regulatory@clicebo.com",{"type":89,"investigatorFullName":58,"investigatorTitle":58,"investigatorAffiliation":58,"oldNameTitle":58,"oldOrganization":58},"SPONSOR","100539163","advapro-coronary-stent-system-in-coronary-artery-diseased-patients-100539163",false,"NCT06300268","Advapro Coronary Stent System in Coronary Artery Diseased Patients.","A Prospective, MulticentRe, Pilot Study to Evaluate the Safety and Performance of The AdvaPro Sirolimus Eluting CorOnary Stent System in Coronary ARtery Stenosis in Indian and European Population(RESTORE)","RESTORE","Inclusion Criteria:\n\n* Age \\>18 years\n* Gender : All (Males, Females, Transgenders, Non-binary)\n* ICF : Patient or legally authorized representative (LAR) agrees to participation by signing the informed consent form.\n* Condition - Clinical : Patient with coronary artery disease Eligible for percutaneous coronary intervention (PCI)\n* Condition - Angiographic : Patient with coronary artery disease having one or more de novo stenosis lesion in two native coronary artery with a visually estimated diameter stenosis ≥70%\n* Condition - Angiographic : Patients with Reference vessel diameter of 2.5 \\~ 3.50 mm\n* Condition - Angiographic : Patients with lesion length ≤ 36 mm\n\nExclusion Criteria:\n\n* Ethical : Pregnant and lactating females\n* Patients requiring staged procedure\n* Condition : Known congestive heart failure (NYHA IV) or left ventricular ejection fraction (LVEF) \\\u003C30%\n* Condition : Patients with known hypersensitivity or allergies to aspirin, heparin, clopidogrel, ticlopidine, Sirolimus or similar drugs, or any other analogue or derivative, cobalt, chromium, nickel, molybdenum or contrast media\n* Condition : Current medical condition with a life expectancy of less than 12 months\n* Condition : Diagnosis: Acute Myocardial Infarction within 72 hours of Planned Index procedure\n* Condition : Patient has current unstable arrhythmias\n* Procedural : Patients previously treated with PCI or CABG for any coronary artery lesion revascularization\n* Procedural : Patients with Chronic Total Occlusion in two or more vessels\n* Procedural : Patients with Ostial lesions (within 5.0mm of vessel origin).\n* Procedural : Patients with Bifurcation lesions that include a side branch \\>2.0 mm diameter\n* Procedural : Unprotected Left Main Coronary Artery lesion\n* Condition : Heavily calcified lesion and\u002For calcified lesion which cannot be successfully predilated in opinion of the treating cardiologist\n* Condition : Patients with Cardiogenic shock, systemic bleeding and coagulation disorders, intracranial bleeding, Renal insufficiency requiring dialysis, Acute or chronic renal function (serum creatinine \\>2.0mg\u002Fdl or 150 µmol\u002FL), peripheral vascular diseases, cancer, etc. and patients who are planning to undergo surgery within 1 year of the index procedure\n* Condition : Patients with platelet count \\\u003C100.000 cells\u002Fmm3 or \\>700.000 cells\u002Fmm3 or a WBC \\\u003C3.000 cells\u002Fmm3","ALL","18 Years",{"count":101,"type":102},120,"ESTIMATED","INTERVENTIONAL",[54],"A Prospective, Multicentre, Pilot Study to Evaluate the Safety and Performance of the AdvaPro Sirolimus Eluting Coronary Stent System in Coronary Artery Stenosis in Indian and European Population.\n\nTo evaluate the performance of AdvaPro Sirolimus Eluting Stent follow up indicated by MACE at 9 months.\n\nOf the 120, 40 patients will be assigned to European population and 80 patients will be assigned to Indian population. QCA is applicable for only in sub-strategy participants at baseline and 9 month follow-up visit.\n\nA QCA Analysis will be performed on minimum 48 patients in Indian population only.\n\nInterval(Days) for patients visit at Day 0, Day 30±6, Day 180±8, Day 270±10 and Day 360±14.",[107,108,109],"Coronary Artery Disease","De Novo Stenosis Lesion","Coronary Stent Implantation",[65,111,112,113,114],"Late lumen loss","Advanced Medtech Solutions","QCA","PTCA","NOT_YET_RECRUITING","2024-03-06",{"date":118,"type":119},"2024-03-08","ACTUAL",{"date":121,"type":102},"2024-06",{"date":123,"type":102},"2026-12",{"name":5,"class":6}]