[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100662597":3},{"organization":4,"outcomesModule":7,"designInfo":39,"detailedDescription":42,"studyPopulation":43,"armGroups":44,"interventions":50,"overallOfficials":38,"centralContacts":58,"locations":64,"responsibleParty":83,"collaborators":38,"id":85,"slug":86,"hasResults":87,"nctId":88,"briefTitle":89,"officialTitle":90,"acronym":91,"eligibilityCriteria":92,"healthyVolunteers":87,"sex":93,"minAge":94,"maxAge":95,"enrollmentInfo":96,"targetDuration":38,"studyType":99,"phases":38,"briefSummary":100,"conditions":101,"keywords":38,"overallStatus":66,"whyStopped":38,"lastUpdateSubmitDate":104,"lastUpdatePostDateStruct":105,"startDateStruct":108,"completionDateStruct":110,"leadSponsor":112,"locationsCount":113},{"fullName":5,"class":6},"Nanfang Hospital, Southern Medical University","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":31,"otherOutcomes":38},[9,13,16,19,22,25,28],{"measure":10,"description":11,"timeFrame":12},"Change in Anterior Chamber Depth (ACD)","Anterior chamber depth (ACD), defined as the distance from the posterior corneal surface to the anterior lens surface along the visual axis, will be measured in millimeters (mm) using swept-source anterior segment optical coherence tomography (SS-OCT; CASIA2). Changes from the preoperative baseline will be calculated at each postoperative follow-up visit.","Preoperative baseline; postoperative day 1, week 1, month 1, and month 3",{"measure":14,"description":15,"timeFrame":12},"Change in Anterior Chamber Width (ACW)","Anterior chamber width (ACW), defined as the distance between the nasal and temporal scleral spurs, will be measured in millimeters (mm) using swept-source anterior segment optical coherence tomography (SS-OCT; CASIA2). Changes from the preoperative baseline will be calculated at each postoperative follow-up visit.",{"measure":17,"description":18,"timeFrame":12},"Change in Anterior Chamber Volume (ACV)","Anterior chamber volume (ACV) will be quantified in cubic millimeters (mm³) using the anterior chamber analysis function of swept-source anterior segment optical coherence tomography (SS-OCT; CASIA2). Changes from the preoperative baseline will be calculated at each postoperative follow-up visit.",{"measure":20,"description":21,"timeFrame":12},"Change in Angle Opening Distance at 500 μm (AOD500)","Angle opening distance at 500 μm (AOD500) will be measured in millimeters (mm) using swept-source anterior segment optical coherence tomography (SS-OCT; CASIA2). AOD500 is defined as the distance between the corneal endothelium and the anterior iris surface along a line perpendicular to the trabecular meshwork at 500 μm from the scleral spur. Changes from the preoperative baseline will be calculated at each postoperative follow-up visit.",{"measure":23,"description":24,"timeFrame":12},"Change in Trabecular-Iris Space Area at 500 μm (TISA500)","Trabecular-iris space area at 500 μm (TISA500) will be measured in square millimeters (mm²) using swept-source anterior segment optical coherence tomography (SS-OCT; CASIA2). TISA500 represents the cross-sectional area of the anterior chamber angle bounded by the trabecular meshwork, anterior iris surface, and reference lines at the scleral spur and 500 μm from the scleral spur. Changes from the preoperative baseline will be calculated at each postoperative follow-up visit.",{"measure":26,"description":27,"timeFrame":12},"Change in Trabecular-Iris Angle at 500 μm (TIA500)","Trabecular-iris angle at 500 μm (TIA500) will be measured in degrees using swept-source anterior segment optical coherence tomography (SS-OCT; CASIA2). The angle will be determined from the anterior chamber angle geometry at 500 μm from the scleral spur. Changes from the preoperative baseline will be calculated at each postoperative follow-up visit.",{"measure":29,"description":30,"timeFrame":12},"Change in Iris Curvature (IC)","Iris curvature (IC) will be quantified in millimeters (mm) using swept-source anterior segment optical coherence tomography (SS-OCT; CASIA2). Iris curvature is defined as the maximum perpendicular distance between the posterior iris surface and a reference line connecting the iris root to the pupillary margin. Changes from the preoperative baseline will be calculated at each postoperative follow-up visit.",[32,35],{"measure":33,"description":34,"timeFrame":12},"Correlation Between Preoperative Ocular Biometric Parameters and Postoperative Visual Acuity","Preoperative ocular biometric parameters, including axial length (AL, mm), anterior chamber depth (ACD, mm), lens thickness (LT, mm), and white-to-white distance (WTW, mm), will be measured using swept-source anterior segment optical coherence tomography (SS-OCT; CASIA2). Postoperative visual acuity will be assessed using a standardized visual acuity chart and expressed in logarithm of the minimum angle of resolution (logMAR) units. Correlations between each preoperative biometric parameter and postoperative visual acuity will be evaluated using Pearson's or Spearman's correlation coefficient, as appropriate. Correlation coefficients will be reported as dimensionless values ranging from -1 to +1",{"measure":36,"description":37,"timeFrame":12},"Correlation Between Preoperative Ocular Biometric Parameters and Postoperative Spherical Equivalent Refraction","Preoperative ocular biometric parameters, including axial length (AL, mm), anterior chamber depth (ACD, mm), lens thickness (LT, mm), and white-to-white distance (WTW, mm), will be measured using swept-source anterior segment optical coherence tomography (SS-OCT; CASIA2). Postoperative refractive status will be assessed by refraction examination and expressed as spherical equivalent refraction (SER) in diopters (D), calculated as spherical power plus half of the cylindrical power. Correlations between each preoperative biometric parameter and postoperative SER will be evaluated using Pearson's or Spearman's correlation coefficient, as appropriate. Correlation coefficients will be reported as dimensionless values ranging from -1 to +1.",null,{"allocation":38,"interventionModel":38,"interventionModelDescription":38,"primaryPurpose":38,"observationalModel":40,"timePerspective":41,"maskingInfo":38},"COHORT","PROSPECTIVE","1. Background The anatomical structures of the anterior segment of the eye play an important role in ocular function and the clinical management of patients undergoing anterior segment surgery. Accurate evaluation of ocular anatomical parameters may provide valuable information for understanding individual anatomical characteristics and supporting clinical assessment.\n\n   Swept-source optical coherence tomography (SS-OCT) is a non-invasive imaging technology that enables detailed visualization and quantitative assessment of anterior segment structures. It provides an opportunity to investigate ocular anatomical characteristics in patients undergoing anterior segment surgery.\n2. Study Objectives This study aims to characterize ocular anatomical parameters in patients undergoing anterior segment surgery using SS-OCT. The study will examine the distribution and variation of these parameters and explore potential associations between ocular anatomical characteristics and relevant clinical factors.\n3. Study Design and Methods This is a prospective observational study involving patients undergoing anterior segment surgery at Nanfang Hospital, Southern Medical University.\n\n   Ocular anatomical parameters will be assessed using SS-OCT. Relevant demographic and clinical information will also be collected to support the evaluation of anatomical characteristics. The collected data will be analyzed to describe the distribution of ocular anatomical parameters and investigate potential differences or associations across relevant patient characteristics.\n\n   The study is observational in nature. Surgical treatment decisions will be made according to routine clinical practice rather than assigned by the research protocol.\n4. Expected Significance This study is expected to provide a better understanding of ocular anatomical characteristics in patients undergoing anterior segment surgery. The findings may contribute to the clinical application of SS-OCT and provide reference information for anatomical assessment and individualized clinical management.","The study population will consist of adult patients aged 18 to 89 years who are scheduled to undergo anterior segment surgery at Nanfang Hospital, Southern Medical University. Eligible patients include those diagnosed with cataract, primary angle-closure disease, glaucoma with cataract, or other anterior segment disorders requiring surgical treatment. Surgical procedures may include phacoemulsification with intraocular lens implantation, goniosynechialysis, ab interno trabeculotomy, and related combined procedures. Treatment decisions will be made according to routine clinical practice. Approximately 500 participants will be enrolled in this prospective observational study.",[45],{"label":46,"type":38,"description":47,"interventionNames":48},"Patients Undergoing Anterior Segment Surgery","Patients undergoing anterior segment surgery will be enrolled in this observational study. Ocular anatomical parameters will be assessed using swept-source optical coherence tomography (SS-OCT). Surgical treatment will be determined according to routine clinical practice, without assignment of treatment interventions by the study protocol.",[49],"Diagnostic Test: Ocular anatomical parameters will be measured using a swept-source optical coherence tomography (SS-OCT) device (CASIA2; Tomey Corporation, Nagoya, Japan). The imaging examination will be used to asse",[51],{"type":52,"name":53,"description":54,"armGroupLabels":55,"otherNames":56},"DIAGNOSTIC_TEST","Ocular anatomical parameters will be measured using a swept-source optical coherence tomography (SS-OCT) device (CASIA2; Tomey Corporation, Nagoya, Japan). The imaging examination will be used to asse","Ocular anatomical parameters will be assessed using a swept-source optical coherence tomography (SS-OCT) device (CASIA2; Tomey Corporation, Nagoya, Japan). This non-invasive imaging examination provides detailed visualization and quantitative measurements of anterior segment structures. The collected imaging data will be used to evaluate ocular anatomical characteristics and investigate their associations with relevant clinical factors in patients undergoing anterior segment surgery. Surgical treatment decisions will follow routine clinical practice and will not be assigned by the study protocol.",[46],[57],"CASIA2",[59],{"name":60,"role":61,"phone":62,"phoneExt":38,"email":63},"Hongyang Zhang","CONTACT","13503005716","zengli729600@163.com",[65],{"facility":5,"status":66,"city":67,"state":68,"zip":69,"country":70,"countryCode":71,"cosmosGeoPoint":72,"geoPoint":77,"contacts":78},"RECRUITING","Guangzhou","Guangdong","510515","China","CN",{"type":73,"coordinates":74},"Point",[75,76],113.25,23.11667,{"lat":76,"lon":75},[79],{"name":80,"role":61,"phone":81,"phoneExt":38,"email":82},"LI Zeng","18990646290","3147282815@qq.com",{"type":84,"investigatorFullName":38,"investigatorTitle":38,"investigatorAffiliation":38,"oldNameTitle":38,"oldOrganization":38},"SPONSOR","100662597","anterior-segment-anatomy-assessed-by-swept-source-oct-in-ocular-surgery-patients-100662597",false,"NCT07903454","Anterior Segment Anatomy Assessed by Swept-Source OCT in Ocular Surgery Patients","Ocular Anatomical Parameters in Patients Undergoing Anterior Segment Surgery Based on Swept-Source Optical Coherence Tomography: An Observational Study","SS-OCT","Inclusion Criteria:\n\n* Voluntary provision of written informed consent.\n* 18≤Age≤90 years.\n* Patients diagnosed by an ophthalmologist with cataract, primary angle-closure disease, or other anterior segment disorders requiring anterior segment surgery.\n* Availability of complete or accessible preoperative and postoperative clinical records and ophthalmic examination data.\n\nExclusion Criteria:\n\n* Follow-up duration of less than 3 months.\n* Substantial missing ophthalmic examination or perioperative data that prevents the required study analyses.\n* Inability to obtain valid anterior segment imaging data due to severe corneal opacity, poor ocular fixation, inadequate cooperation, or other related factors.\n* Presence of severe ocular trauma, intraocular tumors, severe corneal disease, active intraocular inflammation, or other ocular conditions that may substantially affect anterior segment structural assessment.\n* History of complex intraocular surgery that may significantly alter anterior segment anatomy and is considered unsuitable for inclusion by the investigator.\n* Other conditions considered by the investigator to make the patient unsuitable for participation in the study.","ALL","18 Years","90 Years",{"count":97,"type":98},500,"ESTIMATED","OBSERVATIONAL","This observational study aims to evaluate ocular anatomical parameters in patients undergoing anterior segment surgery using swept-source optical coherence tomography (SS-OCT).\n\nAnterior segment surgery, including procedures involving the cornea, lens, and other anterior eye structures, may be associated with changes in ocular anatomy. SS-OCT is a non-invasive imaging technique that provides detailed images of the anterior structures of the eye and allows quantitative assessment of ocular anatomical parameters.\n\nPatients undergoing anterior segment surgery at Nanfang Hospital, Southern Medical University, will be included in this study. SS-OCT will be used to assess ocular anatomical parameters, and the collected measurements will be analyzed to characterize anatomical features and explore potential differences among patients undergoing different types of anterior segment surgery.\n\nThe findings of this study may improve understanding of ocular anatomical characteristics in patients undergoing anterior segment surgery and provide useful information for clinical assessment and surgical management.",[102,103],"Cataract","Primary Angle-Closure Glaucoma","2026-10-22",{"date":106,"type":107},"2026-10-29","ACTUAL",{"date":109,"type":107},"2026-05-01",{"date":111,"type":98},"2028-03-31",{"name":5,"class":6},1]