[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100666760":3},{"organization":4,"outcomesModule":7,"designInfo":18,"detailedDescription":21,"studyPopulation":22,"armGroups":23,"interventions":29,"overallOfficials":17,"centralContacts":37,"locations":43,"responsibleParty":62,"collaborators":64,"id":68,"slug":69,"hasResults":70,"nctId":71,"briefTitle":72,"officialTitle":72,"acronym":73,"eligibilityCriteria":74,"healthyVolunteers":70,"sex":75,"minAge":76,"maxAge":17,"enrollmentInfo":77,"targetDuration":17,"studyType":80,"phases":17,"briefSummary":81,"conditions":82,"keywords":86,"overallStatus":95,"whyStopped":17,"lastUpdateSubmitDate":96,"lastUpdatePostDateStruct":97,"startDateStruct":100,"completionDateStruct":102,"leadSponsor":104,"locationsCount":105},{"fullName":5,"class":6},"NHS Grampian","OTHER_GOV",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":17},[9],{"measure":10,"description":11,"timeFrame":12},"Comparison of ADCs","Quantitative measurement of the change in ADC post treatment to determine whether a larger trial is justified. If the pilot study is successful in providing evidence that quantitative ADCs can be used to predict treatment outcomes, this study will be used as justification for a trial with a larger patient cohort to provide sufficient evidence to bring the technique into routine clinical use.","Up to aroung 6 months post-treatment for each recruited participant",[14],{"measure":15,"description":16,"timeFrame":12},"Higher order analysis of ADCs","Determining whether radiomics analysis can provide data showing if the tumour has responded to treatment at an earlier stage than other means, such as using RECIST criteria to evaluate response at 6 months (this is the current clinical workflow).",null,{"allocation":17,"interventionModel":17,"interventionModelDescription":17,"primaryPurpose":17,"observationalModel":19,"timePerspective":20,"maskingInfo":17},"COHORT","PROSPECTIVE","Water molecules constantly disperse randomly by diffusion, at a rate which can be measured and quantified using magnetic resonance imaging (MRI) diffusion-weighted imaging. The rate of diffusion is dependent on the tissue structure in the region of interest and can be quantified for each image pixel by the apparent diffusion coefficient (ADC). Diffusion is usually restricted in tumour tissue compared with healthy tissue, so tumour tissue typically has lower ADCs. Therefore, diffusion imaging can be used to help identify cancerous tissue and analyse its structure.\n\nThis pilot trial will investigate whether using MRI ADC maps allows us to reliably assess if patients have responded to high-dose liver stereotactic ablative radiotherapy (SABR) treatment. There is evidence from previous studies suggesting quantitative diffusion imaging could allow identification of changes to the structure of tumours within a few days of radiotherapy treatment. For comparison, the current clinical imaging methods take several months to show whether the patient has responded or not.\n\nSix suitable patients referred for liver SABR treatment will be recruited onto the trial and imaged with MRI diffusion imaging before treatment and 4 times in the 6 months following treatment. Qualitative and quantitative analysis will be completed for the images, allowing changes in ADC post-treatment to be monitored. We aim to determine whether a change in ADC corresponds to the tumour responding to treatment and how soon after treatment this change is visible.\n\nIf the trial demonstrates that MRI diffusion imaging can be used to determine if liver tumours are responding to treatment in the days and weeks after treatment, it may be possible to reduce the length of time patients are anxiously waiting to find out if their treatment has worked by several months, as well as provide doctors with more information for further clinical decisions.","Patients who have been prescribed a minimum of 45Gy SABR treatment for hepatocellular carcinoma or colon metastases in the liver",[24],{"label":25,"type":17,"description":26,"interventionNames":27},"Liver Patient Cohort","A cohort of 6 participants receiving liver SABR treatment for HCC or CRC mets and who do not have contraindications to 3T MRI.",[28],"Diagnostic Test: Magnetic Resonance Imaging with Contrast",[30],{"type":31,"name":32,"description":33,"armGroupLabels":34,"otherNames":35},"DIAGNOSTIC_TEST","Magnetic Resonance Imaging with Contrast","Each participant will receive 5 additional MRI scans based off of the standard LI-RADS protocol, including diffusion-weighted imaging. The scans will take place the week before SABR treatment, then 1 week, 1 month, 3 months and 6 months post treatment.",[25],[36],"diffusion-weighted imaging",[38],{"name":39,"role":40,"phone":41,"phoneExt":17,"email":42},"Emily C Kilgour, BA (Hons), MSc","CONTACT","01224 559307","emily.kilgour@nhs.scot",[44],{"facility":45,"status":17,"city":46,"state":47,"zip":48,"country":49,"countryCode":50,"cosmosGeoPoint":51,"geoPoint":56,"contacts":57},"Aberdeen Royal Infirmary","Aberdeen","Scotland","AB25 2ZN","United Kingdom","UK",{"type":52,"coordinates":53},"Point",[54,55],-2.09814,57.14369,{"lat":55,"lon":54},[58,59],{"name":39,"role":40,"phone":41,"phoneExt":17,"email":42},{"name":60,"role":40,"phone":17,"phoneExt":17,"email":61},"John McLellan","john.mclellan@nhs.scot",{"type":63,"investigatorFullName":17,"investigatorTitle":17,"investigatorAffiliation":17,"oldNameTitle":17,"oldOrganization":17},"SPONSOR",[65],{"name":66,"class":67},"University of Aberdeen","OTHER","100666760","apparent-diffusion-coefficient-as-a-predictor-of-liver-sabr-treatment-outcome-100666760",false,"NCT07959055","Apparent Diffusion Coefficient as A Predictor of Liver SABR Treatment Outcome","ADAPTO","Inclusion Criteria:\n\n* older than 18 years old\n* able to undergo MR scans for the duration for the study referred for liver SABR treatment\n* able to provide informed consent and understand written and spoken English\n\nExclusion Criteria:\n\n* they have a contraindication to 3T MRI, a gadolinium contrast allergy, or a recent GFR test indicating they are at risk of complications from being scanned using gadolinium contrast. Their status with respect to these factors will be monitored throughout the trial and they may receive additional GFR tests to ensure they can undergo contrast-enhanced MRI with minimal risk.\n* they have an implant which is likely to reduce the quality of the images e.g. hip prosthesis. Certain implants, for example surgical\u002Fhaemostatic clips, biopsy markers, stents, TIPS shunts and embolisation coils, could also present a risk of artefact for DWI at 3T and will be assessed at screening.\n* they are pregnant (who will not be referred for SABR treatment and so would not reach the stage where participants are being selected).","ALL","18 Years",{"count":78,"type":79},6,"ESTIMATED","OBSERVATIONAL","The ADAPTO study is a pilot trial where 6 participants receiving liver SABR treatment will be recruited. Participants will have MRI scans before treatment, then 1 week, 1 month, 3 months and 6 months after treatment, focusing partiuclarly on diffusion imaging (which creates a map of water movement over the imaging region). Since tumours are structured differently from healthy tissue, they look different on diffusion maps. Previous studies show that changes to the tumour caused by treatment should be visible on diffusion maps earlier after treatment than using the methods used at the moment to watch tumour response to treatment. This study will analyse the diffusion maps (both qualitatively and quantitatively) before and after treatment to investigate when tumour response can be detected and assessed using this imaging method compared with the standard follow up processes in use clinically. If tumour response can be accurately assessed at an earlier point than standard follow up processes when using diffusion imaging, this opens up possibilities to use this technique to reduce the time patients wait to know if their treatment has been effective and make clinical decision making possible at an earlier stage.",[83,84,85],"Liver Cancer (Primary and Metastatic)","SABR","Diffusion MRI",[87,88,89,90,84,91,92,93,94],"MRI","diffusion","DWI","apparent diffusion coefficient (ADC)","clinical biomarkers","radiotherapy","radiomics","treatment response monitoring","NOT_YET_RECRUITING","2026-11-18",{"date":98,"type":99},"2026-11-25","ACTUAL",{"date":101,"type":79},"2026-12",{"date":103,"type":79},"2027-12",{"name":5,"class":6},1]