[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100660363":3},{"organization":4,"outcomesModule":7,"designInfo":43,"detailedDescription":52,"studyPopulation":48,"armGroups":53,"interventions":60,"overallOfficials":68,"centralContacts":72,"locations":77,"responsibleParty":94,"collaborators":48,"id":96,"slug":97,"hasResults":98,"nctId":99,"briefTitle":100,"officialTitle":101,"acronym":102,"eligibilityCriteria":103,"healthyVolunteers":98,"sex":104,"minAge":105,"maxAge":48,"enrollmentInfo":106,"targetDuration":48,"studyType":109,"phases":110,"briefSummary":111,"conditions":112,"keywords":114,"overallStatus":117,"whyStopped":48,"lastUpdateSubmitDate":118,"lastUpdatePostDateStruct":119,"startDateStruct":122,"completionDateStruct":124,"leadSponsor":126,"locationsCount":127},{"fullName":5,"class":6},"Fondazione Policlinico Universitario Agostino Gemelli IRCCS","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":16,"otherOutcomes":38},[9,13],{"measure":10,"description":11,"timeFrame":12},"Patient-level sensitivity of Pi stand-alone for clinically significant prostate cancer (Gleason score >=3+4)","Proportion of participants with clinically significant prostate cancer (csPCa, Gleason score \\>=3+4 \u002F ISUP grade group \\>=2) correctly identified as positive by Prostate Intelligence (Pi) stand-alone at a threshold fixed before study start. Reference standard: histopathology from MRI-targeted biopsy or radical prostatectomy, or composite true negative status (no csPCa on 12-month clinical and PSA follow-up) for non-biopsied participants. Reported with 95% confidence interval; NPV, PPV and ROC AUC also reported.","Index test at baseline MRI; reference standard up to 12 months after MRI",{"measure":14,"description":15,"timeFrame":12},"Patient-level specificity of Pi stand-alone for clinically significant prostate cancer (Gleason score >=3+4)","Proportion of participants without clinically significant prostate cancer (csPCa, Gleason score \\>=3+4 \u002F ISUP grade group \\>=2) correctly identified as negative by Prostate Intelligence (Pi) stand-alone at a threshold fixed before study start. Reference standard: histopathology from MRI-targeted biopsy or radical prostatectomy, or composite true negative status (no csPCa on 12-month clinical and PSA follow-up) for non-biopsied participants. Reported with 95% confidence interval.",[17,20,23,26,29,32,35],{"measure":18,"description":19,"timeFrame":12},"Patient-level sensitivity and specificity of the Pi-assisted radiologist read for csPCa (Gleason score >=3+4)","Sensitivity and specificity of the radiologist's merged report after review of the Pi output, for csPCa defined as Gleason score \\>=3+4. Reference standard: histopathology from MRI-targeted biopsy or radical prostatectomy, or composite true negative status (no csPCa on 12-month clinical and PSA follow-up) for non-biopsied participants. Exploratory.",{"measure":21,"description":22,"timeFrame":12},"Patient-level sensitivity and specificity of the Pi-assisted radiologist read for Gleason score >=4+3 cancer","Sensitivity and specificity of the Pi-assisted read for prostate cancer of Gleason score \\>=4+3 (ISUP grade group \\>=3). Reference standard: histopathology from MRI-targeted biopsy or radical prostatectomy, or composite true negative status (no csPCa on 12-month clinical and PSA follow-up) for non-biopsied participants. Exploratory.",{"measure":24,"description":25,"timeFrame":12},"Diagnostic performance of Pi-assisted read versus radiologist-alone read (ROC AUC)","Difference in patient-level area under the ROC curve between the Pi-assisted read and the radiologist-alone read (blinded to Pi), for csPCa (Gleason score \\>=3+4). Compared with the DeLong method; two-sided 95% CIs by bootstrapping. Sensitivity, specificity, PPV and NPV also compared. Exploratory.",{"measure":27,"description":28,"timeFrame":12},"Diagnostic performance of Pi stand-alone versus radiologist-alone read (ROC AUC)","Difference in patient-level area under the ROC curve between Pi stand-alone and the radiologist-alone read for csPCa (Gleason score \\>=3+4). Compared with the DeLong method; two-sided 95% CIs by bootstrapping. Exploratory.",{"measure":30,"description":31,"timeFrame":12},"Proportion of csPCa detected by Pi-assisted and Pi stand-alone reads versus radiologist-alone read","Proportion of participants with csPCa (Gleason score \\>=3+4) detected by the Pi-assisted read and by Pi stand-alone, compared with the proportion detected by the radiologist-alone read. Exploratory.",{"measure":33,"description":34,"timeFrame":12},"Lesion-level sensitivity and positive predictive value of the Pi-assisted read for csPCa","Lesion-level sensitivity and PPV of the Pi-assisted read for csPCa (Gleason score \\>=3+4), with PI-RADS \\>=3 considered positive; lesions matched to histopathology. Generalised estimating equations account for clustering of multiple lesions within a participant. Exploratory.",{"measure":36,"description":37,"timeFrame":12},"Additional csPCa detected with Pi compared with radiologist-alone read","Number and proportion of csPCa (Gleason score \\>=3+4) lesions\u002Fparticipants detected only through Pi (Pi-identified lesions not reported by the radiologist alone) and confirmed on histopathology. Exploratory.",[39],{"measure":40,"description":41,"timeFrame":42},"Diagnostic performance of Pi stand-alone and Pi-assisted read against radical prostatectomy histopathology","Sensitivity, specificity and lesion-level detection of Pi stand-alone and the Pi-assisted read in the subgroup of participants who undergo radical prostatectomy, using whole-mount prostatectomy histopathology as the reference standard. Exploratory subgroup analysis.","Up to 12 months after MRI",{"allocation":44,"interventionModel":45,"interventionModelDescription":46,"primaryPurpose":47,"observationalModel":48,"timePerspective":48,"maskingInfo":49},"NA","SINGLE_GROUP","Single-group, paired-read diagnostic accuracy design. Every participant's MRI is read sequentially: (1) radiologist alone, blinded to Pi, report locked and time-stamped; (2) Pi stand-alone; (3) Pi-assisted radiologist read. All three index tests are compared against the same reference standard (MRI-targeted biopsy histopathology, radical prostatectomy where available, or 12-month clinical\u002FPSA follow-up for non-biopsied participants). In participants with lesions to biopsy (maximum two), the order of sampling (Pi-identified lesions first vs radiologist-alone-identified lesions first) is block-randomised 1:1 using the Pi software UI; this randomises procedural order only and does not allocate participants to different interventions.","DIAGNOSTIC",null,{"masking":50,"maskingDescription":51,"whoMasked":48},"NONE","Single-arm study, registered as open label. Within the reading workflow, the radiologist-alone assessment is performed blinded to the Pi output and is locked and time-stamped before the Pi report is made available.","Background and rationale Prostate cancer is the most common cancer in men in Europe. International guidelines recommend multiparametric MRI before biopsy, and findings are graded with PI-RADS v2.1. PI-RADS assessment varies with institution, reader experience and field strength, and inter-reader variability is substantial among less experienced radiologists. Prostate Intelligence (Pi, Lucida Medical Ltd) is an AI software that analyses prostate MRI and provides prostate volume, lesion detection\u002Fsegmentation, an AI-Likert score and a preliminary report as a concurrent read to support the radiologist. This study evaluates the diagnostic performance of Pi in a prospective clinical setting.\n\nDesign Prospective, multicentre (national), interventional diagnostic accuracy study with a medical device. The software runs on servers of the participating institutions; DICOM data are de-identified and imaging data do not leave the institutional perimeter.\n\nReading workflow For each examination the radiologist first reports the MRI blinded to Pi; the report is locked and time-stamped in RIS\u002FPACS. The Pi output is then made available and the radiologist produces a merged Pi-assisted report, recording PI-RADS v2.1 categories, lesion zone and whether each Pi finding is accepted or rejected, and adding any lesions considered missed by Pi.\n\nReference standard Histopathology from MRI-targeted biopsy (maximum two lesions, including discordant radiologist\u002FPi lesions) and, where available, radical prostatectomy. Participants who are not biopsied are followed for 12 months after MRI (PSA at 6 and 12 months plus clinical assessment) and classified as composite true negatives when there is no evidence of clinically significant cancer. Clinically significant prostate cancer (csPCa) is defined as Gleason grade 3+4 or higher.\n\nEndpoints Co-primary: patient-level sensitivity and specificity of stand-alone Pi for csPCa (Gleason \\>=3+4).\n\nSecondary (all exploratory): diagnostic performance of the Pi-assisted read at patient level for Gleason \\>=3+4 and \\>=4+3; comparison of Pi-assisted vs radiologist-alone and Pi vs radiologist-alone; proportion of csPCa detected and additional csPCa detection with Pi; lesion-level performance of the Pi-assisted read; exploratory cost-consequence analysis; subgroup performance in patients with radical prostatectomy histology.\n\nSample size 226 participants (150 at Gemelli, 76 at San Raffaele), based on 7.5% precision at a 5% significance level for an expected Pi sensitivity of 90% and specificity of 65%, with an assumed csPCa prevalence of 31% (R v4.4.2). Assumptions are conservative relative to published validation of the device. The study is powered for stand-alone accuracy only; comparative endpoints are exploratory.\n\nStatistical analysis Sensitivity, specificity, PPV, NPV and ROC AUC with 95% CIs. AUCs of radiologist-alone, Pi-alone and Pi-assisted reads compared with the DeLong method, with bootstrapped two-sided 95% CIs. Lesion-level metrics (PI-RADS \\>=3 as positive) use generalised estimating equations to account for clustering. The primary analysis includes histologically verified participants and composite true negatives; pre-specified sensitivity analyses are restricted to histologically verified participants and a bounding analysis assigning unverified participants first to non-csPCa and then to csPCa. Missing data are tabulated and the primary analysis uses complete cases. Exploratory comparative p-values are reported unadjusted and Benjamini-Hochberg adjusted (5%). Centre, scanner model and field strength are recorded and explored as subgroups; no centre contributes more than 70% of participants. Reporting follows STARD.\n\nDuration 27 months: 12 months enrolment and data collection, up to 12 months follow-up per participant, 3 months analysis.\n\nSafety All adverse events are recorded; device incidents and deficiencies are reported to the National Competent Authority and the manufacturer under EU Regulation 2017\u002F745 and Italian Legislative Decree 137\u002F2022.",[54],{"label":55,"type":56,"description":57,"interventionNames":58},"Pi-assisted prostate MRI reading","EXPERIMENTAL","Adults with a prostate gland referred for MRI for suspected prostate cancer. Each MRI is assessed by the radiologist alone (blinded to Pi), by Pi stand-alone, and by the radiologist assisted by Pi. Participants with suspicious lesions undergo MRI-targeted biopsy of up to two lesions (radiologist- and\u002For Pi-identified), with the order of lesion sampling randomised 1:1. Participants not biopsied are followed for 12 months after MRI with PSA at 6 and 12 months and clinical assessment.",[59],"Device: AI-based prostate MRI analysis software",[61],{"type":62,"name":63,"description":64,"armGroupLabels":65,"otherNames":66},"DEVICE","AI-based prostate MRI analysis software","Prostate Intelligence (Pi, Lucida Medical Ltd) is an artificial intelligence software that analyses prostate MRI and provides prostate volume, lesion detection and segmentation, an AI-Likert score and a preliminary report. It runs on the participating institutions' servers on de-identified DICOM data. Each MRI is first reported by the radiologist blinded to Pi (report locked and time-stamped); Pi output is then revealed and the radiologist issues a merged Pi-assisted report (PI-RADS v2.1), accepting or rejecting each Pi finding. Up to two lesions per participant (radiologist- and\u002For Pi-identified) undergo MRI-targeted biopsy, with sampling order randomised 1:1. Non-biopsied participants are followed for 12 months (PSA at 6 and 12 months, clinical assessment).",[55],[67],"Prostate Intelligence (Pi)",[69],{"name":70,"affiliation":5,"role":71},"Luca Russo, MD, PhD","PRINCIPAL_INVESTIGATOR",[73],{"name":70,"role":74,"phone":75,"phoneExt":48,"email":76},"CONTACT","+39 06 30156054","luca.russo@policlinicogemelli.it",[78],{"facility":79,"status":48,"city":80,"state":81,"zip":82,"country":83,"countryCode":84,"cosmosGeoPoint":85,"geoPoint":90,"contacts":91},"Fondazione Policlinico Universitario A. Gemelli IRCCS","Rome","Lazio","00168","Italy","IT",{"type":86,"coordinates":87},"Point",[88,89],12.51133,41.89193,{"lat":89,"lon":88},[92,93],{"name":70,"role":74,"phone":75,"phoneExt":48,"email":76},{"name":70,"role":71,"phone":48,"phoneExt":48,"email":48},{"type":95,"investigatorFullName":48,"investigatorTitle":48,"investigatorAffiliation":48,"oldNameTitle":48,"oldOrganization":48},"SPONSOR","100660363","artificial-intelligence-software-prostate-intelligence-for-detecting-clinically-significant-prostate-cancer-on-mri-100660363",false,"NCT07875491","Artificial Intelligence Software (Prostate Intelligence) for Detecting Clinically Significant Prostate Cancer on MRI","A Prospective, Multi-Centre Diagnostic Accuracy Study of AI-based Prostate Cancer Diagnosis Software","RADAR","Inclusion Criteria:\n\n* Individuals with a prostate gland (biological males, including transgender women with a prostate gland)\n* Age 18 years or older\n* Referred for prostate MRI for suspected prostate cancer\n* Signed informed consent and consent to personal data processing\n\nExclusion Criteria:\n\n* Previous prostate biopsy\n* Previous treatment for prostate cancer or benign prostatic hyperplasia\n* Any factor that may compromise MRI scan quality (e.g. metal implants, UroLift)\n* Contraindications to MRI\n* Contraindications to prostate biopsy\n* Failure to sign informed consent and\u002For consent to personal data processing","MALE","18 Years",{"count":107,"type":108},226,"ESTIMATED","INTERVENTIONAL",[44],"The goal of this study is to learn how accurately an artificial intelligence (AI) software called Prostate Intelligence (Pi) detects clinically significant prostate cancer on prostate MRI in adults with a prostate gland who are referred for MRI because prostate cancer is suspected.\n\nThe main question it aims to answer is:\n\n\\- How sensitive and specific is Pi, used on its own, in detecting clinically significant prostate cancer (Gleason grade 3+4 or higher) at the patient level?\n\nResearchers will also compare Pi, the radiologist alone, and the radiologist assisted by Pi, to see whether AI assistance changes cancer detection.\n\nParticipants will:\n\n* Undergo prostate MRI as part of their usual clinical care. Each MRI is first read by a radiologist without the AI result; the Pi report is then shown to the radiologist, who produces a final combined report.\n* Undergo targeted prostate biopsy (up to two lesions) if the MRI is suspicious, as in routine practice. Areas flagged only by Pi may also be biopsied.\n* If not biopsied, be followed for 12 months after MRI with PSA tests at 6 and 12 months and clinical assessment, to confirm the absence of clinically significant cancer.\n\nAbout 226 participants will be enrolled at two Italian centres (Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, and IRCCS Ospedale San Raffaele, Milan).",[113],"Prostate Cancer",[115,116],"prostate cancer","magnetic resonance imaging","NOT_YET_RECRUITING","2026-10-08",{"date":120,"type":121},"2026-10-15","ACTUAL",{"date":123,"type":108},"2026-11",{"date":125,"type":108},"2027-07",{"name":5,"class":6},1]