[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100664495":3},{"organization":4,"outcomesModule":7,"designInfo":43,"detailedDescription":53,"studyPopulation":42,"armGroups":54,"interventions":67,"overallOfficials":78,"centralContacts":83,"locations":92,"responsibleParty":110,"collaborators":112,"id":114,"slug":115,"hasResults":116,"nctId":117,"briefTitle":118,"officialTitle":119,"acronym":42,"eligibilityCriteria":120,"healthyVolunteers":116,"sex":121,"minAge":122,"maxAge":42,"enrollmentInfo":123,"targetDuration":42,"studyType":126,"phases":127,"briefSummary":129,"conditions":130,"keywords":136,"overallStatus":142,"whyStopped":42,"lastUpdateSubmitDate":143,"lastUpdatePostDateStruct":144,"startDateStruct":147,"completionDateStruct":149,"leadSponsor":151,"locationsCount":152},{"fullName":5,"class":6},"Aether Tech S.L.","INDUSTRY",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":42},[9],{"measure":10,"description":11,"timeFrame":12},"EFFICACY - EVALUATION OF THE RATE THE DEVICE MAINTAINS BLOOD OXYGEN SATURATION LEVELS","Percentage of monitored time with SpO2, measured by pulse oximetry, within the predefined target range (hypoxemic patients 94-98%; hypercapnic patients 92-94%), without delivering less or more oxygen than required. Comparing the closed-loop period (EMILY.AI) and the manual titration period.","From randomization to hospital discharge, up to 30 days.",[14,17,20,23,26,29,32,35,39],{"measure":15,"description":16,"timeFrame":12},"ACCURACY - MEASUREMENT OF THE SYSTEM'S ACTION SPEED CORRECTING THE OXYGEN SATURATION","Time in seconds from 1) detection of SpO2 outside the target range to the start of correction and 2) the return to the target range.",{"measure":18,"description":19,"timeFrame":12},"SAFETY - TIME WITH OXYGEN SATURATION BELOW AND ABOVE THE TARGET RANGE","Percentage of monitored time with SpO2 below and above the target range, as indicators of insufficient or excess in oxygen delivery. Comparing the closed-loop period (EMILY.AI) and the manual titration period.",{"measure":21,"description":22,"timeFrame":12},"EFFICIENCY - MEASUREMENT OF THE NUMBER OF TIMES THE MEDICAL AND NURSING TEAM MUST ADJUST OXYGENATION","Number of nursing or medical interventions to adjust oxygen flow or address oxygenation-related symptoms. Comparing the closed-loop period (EMILY.AI) and the manual titration period.",{"measure":24,"description":25,"timeFrame":12},"EFFICIENCY - OXYGEN FLOW DELIVERED","Mean delivered oxygen flow (L\u002Fmin), distinguishing flow delivered while SpO2 was above the target range, comparing the closed-loop period (EMILY.AI) and the manual titration period.",{"measure":27,"description":28,"timeFrame":12},"ALERT SYSTEM - MEASUREMENT OF THE NUMBER OF SYSTEM ALERTS","Number of alerts generated by EMILY.AI for changes in the oxygen saturation of monitored patients.",{"measure":30,"description":31,"timeFrame":12},"ALERT SYSTEM - EVALUATION OF THE AUTHENTICITY OF THE SYSTEM ALERTS BY COMPARING THE OXYGEN SATURATION LEVELS WITH A CONVENTIONAL SYSTEM","Proportion of alerts confirmed by the conventional monitor and, in case of discrepancy, by arterial blood gasometry.",{"measure":33,"description":34,"timeFrame":12},"VERSATILITY - COMPARISON OF BLOOD OXYGEN SATURATION LEVELS MAINTENANCE BETWEEN DIFFERENT PROFILES AND SITUATIONS","Percentage of time within the target range compared between hypoxaemic and hypercapnic participants and different clinical situations (bed rest, sitting, eating, physiotherapy).",{"measure":36,"description":37,"timeFrame":38},"CLINICAL BENEFIT - DYSPNOEA, ACTIVITY TOLERANCE, COMFORT AND SATISFACTION","Participant-reported dyspnoea and tolerance during hygiene, meals and physiotherapy, comfort and satisfactaction with Likert-scale questionnaire.","At randomization and at hospital discharge (up to 30 days).",{"measure":40,"description":41,"timeFrame":12},"ADAPTABILITY - AGREEMENT BETWEEN PULSE OXIMETER MODELS","Agreement of SpO2 measurements and trends between pulse oximeter models (Nonin, Masimo, Nihon Kohden) acceptable when variability is below 10% and does not affect patient management",null,{"allocation":44,"interventionModel":45,"interventionModelDescription":46,"primaryPurpose":47,"observationalModel":42,"timePerspective":42,"maskingInfo":48},"RANDOMIZED","PARALLEL","Participants are randomized 1:1 to automatic oxygen titration by EMILY.AI or to usual care with manual titration, using permuted blocks of 4 stratified by main admission diagnosis and prior long-term home oxygen therapy. All participants wear the device from randomization to discharge.","TREATMENT",{"masking":49,"maskingDescription":50,"whoMasked":51},"SINGLE","All participants are connected to the same device, which titrates oxygen in the EMILY arm and works in fixed mode in the MANUAL arm, so participants cannot tell which group they are in. Investigators and nurses are not masked.",[52],"PARTICIPANT","Background On conventional hospital wards, oxygen is usually given at a fixed flow and saturation is checked about once per nursing shift, so periods of hypoxaemia or hyperoxaemia can go undetected. EMILY.AI combines a medical-grade oxygen valve with a rule-based algorithm that sets the oxygen flow.\n\nDesign Prospective, single-blind (participant), randomized, parallel-group study. Participants are randomized 1:1 to the EMILY arm (automatic titration) or the MANUAL arm (usual care with nursing monitoring every 8 hours and a fixed oxygen prescription), using permuted blocks of 4 stratified by main admission diagnosis (COPD exacerbation, pneumonia, interstitial lung disease, other) and prior long-term home oxygen therapy (yes or no). Allocation takes place after eligibility is confirmed and informed consent is signed.\n\nIntervention and follow-up All participants are connected to the EMILY.AI device continuously from randomization until hospital discharge. In the EMILY arm the device titrates oxygen autonomously to keep SpO2 within the target range for the type of respiratory failure (hypoxaemic 91-97%; hypercapnic 91-94%). In the MANUAL arm the device works in fixed mode, recording SpO2, heart rate and respiratory rate without changing the flow, and nurses adjust oxygen as usual. Conventional back-up oxygen is available at all times.\n\nSample size 100 participants: 80 planned for the main comparison and approximately 20 added by protocol amendment (CIP v8.0) to further validate an adjustment of the algorithm parameter. All 100 are randomized in the same way. As a pilot functional validation, no formal sample size calculation was performed.\n\nThe protocol FJD-EMILY-23-02 also includes a substudy in the Respiratory Intermediate Care Unit and an exercise substudy (six-minute walk test), registered separately.",[55,61],{"label":56,"type":57,"description":58,"interventionNames":59},"EMILY","EXPERIMENTAL","Automatic oxygen titration by EMILY.AI 24 hours a day from randomization to hospital discharge, targeting SpO2 91-97% (hypoxaemic) or 91-94% (hypercapnic).",[60],"Device: EMILY.AI closed-loop oxygen titration",{"label":62,"type":63,"description":64,"interventionNames":65},"MANUAL","ACTIVE_COMPARATOR","Usual care: fixed oxygen prescription adjusted by nursing staff, with vital signs checked every 8 hours. The EMILY.AI device is connected in fixed mode and only records data.",[66],"Other: Manual oxygen titration",[68,73],{"type":69,"name":70,"description":71,"armGroupLabels":72,"otherNames":42},"DEVICE","EMILY.AI closed-loop oxygen titration","Investigational smart oxygen valve with rule-based algorithm that adjusts oxygen flow to keep SpO2 within a target range.",[56],{"type":74,"name":75,"description":76,"armGroupLabels":77,"otherNames":42},"OTHER","Manual oxygen titration","Usual care: oxygen flow set and adjusted by the ward nursing team according to standard practice. The EMILY.AI device stays connected in fixed mode, recording signals but not controlling delivery.",[62],[79],{"name":80,"affiliation":81,"role":82},"Sarah Beatrice Heili Frades, MD, PhD, MD, PhD","Hospital Universitario Fundación Jiménez Díaz","PRINCIPAL_INVESTIGATOR",[84,89],{"name":85,"role":86,"phone":87,"phoneExt":42,"email":88},"Sarah Beatrice Heili Frades, MD, PhD","CONTACT","+34 915 50 48 00","SHeili@fjd.es",{"name":90,"role":86,"phone":87,"phoneExt":42,"email":91},"Alba Naya Prieto, MD","alba.naya@fjd.es",[93],{"facility":81,"status":42,"city":94,"state":42,"zip":95,"country":96,"countryCode":97,"cosmosGeoPoint":98,"geoPoint":103,"contacts":104},"Madrid","28040","Spain","ES",{"type":99,"coordinates":100},"Point",[101,102],-3.70256,40.4165,{"lat":102,"lon":101},[105,107,108],{"name":106,"role":86,"phone":87,"phoneExt":42,"email":88},"Sarah Beatrice Heili Frades Zimmermann MD, PhD",{"name":90,"role":86,"phone":87,"phoneExt":42,"email":91},{"name":109,"role":82,"phone":42,"phoneExt":42,"email":42},"Sarah Beatrice Heili Frades Zimmermann, MD, PhD",{"type":111,"investigatorFullName":42,"investigatorTitle":42,"investigatorAffiliation":42,"oldNameTitle":42,"oldOrganization":42},"SPONSOR",[113],{"name":81,"class":74},"100664495","automated-versus-manual-oxygen-titration-with-the-emilyai-device-in-hospitalized-patients-with-acute-respiratory-failure-100664495",false,"NCT07932847","Automated Versus Manual Oxygen Titration With the EMILY.AI Device in Hospitalized Patients With Acute Respiratory Failure","Functional, Clinical, and Predictive Validation Study of the EMILY AI Device in Patients With Acute and Chronic Respiratory Failure: Randomized Substudy in a Conventional Hospital Ward","Inclusion Criteria:\n\n* Men and women aged 18 years or older.\n* Admitted to the general pulmonology ward (Unit 67) of Hospital Universitario Fundación Jiménez Díaz.\n* Acute respiratory failure, defined as baseline arterial PaO2 below 60 mmHg or the need for supplemental oxygen to maintain SpO2 above 90%. Patients on long-term oxygen therapy are eligible if a clinical deterioration requires a higher-than-usual oxygen flow to maintain SpO2 above 90%.\n* Signed informed consent.\n\nExclusion Criteria:\n\n* Anatomical abnormalities preventing correct placement of the pulse oximeter.\n* Pregnancy or breastfeeding (women of childbearing potential require a negative pregnancy test at screening).\n* Need for non-invasive ventilation or high-flow nasal cannula at admission.\n* Palliative care or limitation of therapeutic effort at admission.\n* Expected hospital stay under 48 hours.\n* Clinical situations expected to determine length of stay independently of oxygen therapy, such as intravenous antibiotics for more than 10 days, scheduled interventional or surgical procedures, active social care needs that may delay discharge, a non-respiratory main admission diagnosis, or acute or decompensated non-respiratory comorbidities.\n* Known or suspected carbon monoxide poisoning or methemoglobinemia.\n* Severe hypercapnia with decompensated respiratory acidosis (pH below 7.30), hemodynamic instability requiring vasoactive drugs, or severe sepsis at admission.\n* Cognitive impairment, behavioral disorder or any circumstance preventing proper use of the device or compliance with study procedures.\n* Simultaneous participation in another interventional clinical trial, or readmission of a patient previously included in this study.","ALL","18 Years",{"count":124,"type":125},100,"ESTIMATED","INTERVENTIONAL",[128],"NA","This randomized study evaluates EMILY.AI, an investigational (non-CE-marked) smart oxygen valve that automatically adjusts the oxygen flow delivered to a patient.\n\nAdults admitted to the pulmonology ward of Hospital Universitario Fundación Jiménez Díaz (Madrid, Spain) with acute respiratory failure are randomly assigned to receive oxygen titrated automatically by EMILY.AI or oxygen managed as usual by the nursing team, from randomization until hospital discharge. All participants wear the device; in the usual-care group it only records data.\n\nThe study compares the time patients stay within their target saturation range, episodes of low and high oxygen, nursing workload, oxygen use, length of stay and patient experience. This substudy is part of clinical investigation FJD-EMILY-23-02, whose other substudies are registered in separate records.",[131,132,133,134,135],"Acute Respiratory Failure","Acute-on-chronic Respiratory Failure","COPD Exacerbation","Pneumonia","Interstitial Lung Diseases",[137,138,139,140,141],"closed-loop oxygen therapy","automated oxygen titration","hospital ward","oxygen saturation target","nursing workload","NOT_YET_RECRUITING","2026-11-16",{"date":145,"type":146},"2026-11-18","ACTUAL",{"date":148,"type":125},"2027-02",{"date":150,"type":125},"2027-12",{"name":5,"class":6},1]