[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100666732":3},{"organization":4,"outcomesModule":7,"designInfo":13,"detailedDescription":22,"studyPopulation":11,"armGroups":23,"interventions":34,"overallOfficials":11,"centralContacts":11,"locations":44,"responsibleParty":81,"collaborators":83,"id":86,"slug":87,"hasResults":88,"nctId":89,"briefTitle":90,"officialTitle":91,"acronym":92,"eligibilityCriteria":93,"healthyVolunteers":88,"sex":94,"minAge":95,"maxAge":11,"enrollmentInfo":96,"targetDuration":11,"studyType":99,"phases":100,"briefSummary":102,"conditions":103,"keywords":105,"overallStatus":107,"whyStopped":11,"lastUpdateSubmitDate":108,"lastUpdatePostDateStruct":109,"startDateStruct":112,"completionDateStruct":114,"leadSponsor":116,"locationsCount":117},{"fullName":5,"class":6},"OMIQ Research","NETWORK",{"primaryOutcomes":8,"secondaryOutcomes":11,"otherOutcomes":11},[9],{"measure":10,"description":11,"timeFrame":12},"Mean binocular distance-corrected near visual acuity at 40 cm",null,"Three months after surgery",{"allocation":14,"interventionModel":15,"interventionModelDescription":11,"primaryPurpose":16,"observationalModel":11,"timePerspective":11,"maskingInfo":17},"RANDOMIZED","PARALLEL","TREATMENT",{"masking":18,"maskingDescription":11,"whoMasked":19},"DOUBLE",[20,21],"PARTICIPANT","OUTCOMES_ASSESSOR","Partial depth of field-extend intraocular lenses (PDOFiEx IOL) are designed to provide excellent distance, very good intermediate and functional near visual acuity with induction of minimal to no dysphotopsia. Many such lenses are available and enter the market regularly, but they are rarely compared on a head-to-head study. This hampers evaluation of their relative advantages and disadvantages.\n\nThis study will evaluate the visual performance of the new Clareon Vivity Pro with the PureSee IOL in patients undergoing bilateral cataract surgery with no other ocular comorbidity.",[24,29],{"label":25,"type":26,"description":11,"interventionNames":27},"A non-refractive intraocular lens","EXPERIMENTAL",[28],"Device: Clareon Vivity Pro",{"label":30,"type":31,"description":11,"interventionNames":32},"A refractive intraocular lens","ACTIVE_COMPARATOR",[33],"Device: PureSee",[35,40],{"type":36,"name":37,"description":38,"armGroupLabels":39,"otherNames":11},"DEVICE","Clareon Vivity Pro","A non-refractive partial depth of field-extend intraocular lens, which provides good distance and also intermediate visual acuity",[25],{"type":36,"name":41,"description":42,"armGroupLabels":43,"otherNames":11},"PureSee","A refractive partial depth of field-extend intraocular lens, which provides good distance and also intermediate visual acuity",[30],[45,65],{"facility":5,"status":11,"city":46,"state":46,"zip":47,"country":48,"countryCode":49,"cosmosGeoPoint":50,"geoPoint":55,"contacts":56},"Barcelona","08195","Spain","ES",{"type":51,"coordinates":52},"Point",[53,54],2.15899,41.38879,{"lat":54,"lon":53},[57,62],{"name":58,"role":59,"phone":60,"phoneExt":11,"email":61},"Aroa Grande","CONTACT","+34937071936","agrande@omiq.es",{"name":63,"role":64,"phone":11,"phoneExt":11,"email":11},"Mercè Guarro","PRINCIPAL_INVESTIGATOR",{"facility":66,"status":11,"city":67,"state":67,"zip":68,"country":48,"countryCode":49,"cosmosGeoPoint":69,"geoPoint":73,"contacts":74},"Vithas Eurocanarias","Las Palmas de Gran Canaria","35004",{"type":51,"coordinates":70},[71,72],-15.41573,28.10178,{"lat":72,"lon":71},[75,79],{"name":76,"role":59,"phone":77,"phoneExt":11,"email":78},"Josefina Reñones","+34928 49 10 90","renonesdaj@vithas.es",{"name":80,"role":64,"phone":11,"phoneExt":11,"email":11},"Humberto Carreras",{"type":82,"investigatorFullName":11,"investigatorTitle":11,"investigatorAffiliation":11,"oldNameTitle":11,"oldOrganization":11},"SPONSOR",[84],{"name":66,"class":85},"UNKNOWN","100666732","clareon-vivity-pro-vs-puresee-intraocular-lenses-100666732",false,"NCT07960225","Clareon Vivity Pro vs PureSee Intraocular Lenses","Characterization of Visual Performance of Clareon Vivity Pro and PureSee Intraocular Lenses","PURVI3","Inclusion Criteria:\n\n* Patients of any sex and race aged 45 years or older\n* Patients undergoing bilateral cataract surgery with clinically significant age-related lens opacity\n* Willing to receive implantation of a PDOFiEx IOL\n* Willing to sign the informed consent and attend the study visits\n\nExclusion Criteria:\n\n* Requirement of a spherical or toric power of the IOL to achieve emmetropia beyond the available range of either of the two lenses (specifically, the requirement of a toric T2-equivalent IOL)\n* Irregular astigmatism\n* Contact lens wear in the previous 3 weeks before biometry\n* Moderate or severe ocular surface, corneal, macular or optic nerve disease that in opinion of the investigator precludes the desired functional results\n* History of previous refractive, cornea, retina or glaucoma surgery\n* Eyes with a clear lens demanding a refractive lens exchange\n* Amblyopia in any eye\n* Significant previous ocular trauma\n* Pregnancy\n* A systemic condition that, in the opinion of the investigator, precludes the reliable assessments required in the study (i.e., dementia) or participation in the study (i.e., severe mobility problems).","ALL","45 Years",{"count":97,"type":98},200,"ESTIMATED","INTERVENTIONAL",[101],"NA","We compared the visual performance of two partial depth of field-extend intraocular lenses, the Clareon Vivity Pro (Alcon Healthcare, US) and the PureSee (Johnson \\& Johnson, US).",[104],"Cataracts",[104,106],"Intraocular lenses","NOT_YET_RECRUITING","2026-11-19",{"date":110,"type":111},"2026-11-25","ACTUAL",{"date":113,"type":98},"2026-12",{"date":115,"type":98},"2027-12",{"name":5,"class":6},2]