[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100662699":3},{"organization":4,"outcomesModule":7,"designInfo":38,"detailedDescription":46,"studyPopulation":37,"armGroups":47,"interventions":54,"overallOfficials":37,"centralContacts":64,"locations":37,"responsibleParty":74,"collaborators":37,"id":76,"slug":77,"hasResults":78,"nctId":79,"briefTitle":80,"officialTitle":81,"acronym":37,"eligibilityCriteria":82,"healthyVolunteers":78,"sex":83,"minAge":84,"maxAge":37,"enrollmentInfo":85,"targetDuration":37,"studyType":88,"phases":89,"briefSummary":90,"conditions":91,"keywords":94,"overallStatus":100,"whyStopped":37,"lastUpdateSubmitDate":101,"lastUpdatePostDateStruct":102,"startDateStruct":105,"completionDateStruct":107,"leadSponsor":109,"locationsCount":37},{"fullName":5,"class":6},"Yonsei University","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":16,"otherOutcomes":37},[9,13],{"measure":10,"description":11,"timeFrame":12},"Side-to-Side Difference in Anterior Knee Laxity Measured by KT-2000 Arthrometer","Anterior knee laxity is measured as the side-to-side difference (SSD, in millimeters) in anterior tibial translation between the injured and contralateral uninjured knee using the KT-2000 arthrometer under a 30-lb (134 N) anterior load at 30 degrees of knee flexion.","Up to 24 months postoperatively (assessed at preoperative baseline, 3, 6, 12, and 24 months after surgery)",{"measure":14,"description":15,"timeFrame":12},"Rotational Knee Stability Evaluated by Pivot-Shift Test","Rotational knee stability evaluated by the manual pivot-shift test and graded according to International Knee Documentation Committee (IKDC) guidelines: Grade 0 (normal\u002Fequal), Grade 1 (glide), Grade 2 (clunk), Grade 3 (gross).",[17,21,24,28,31,34],{"measure":18,"description":19,"timeFrame":20},"Graft Signal-to-Noise Quotient (SNQ) on Postoperative MRI","Graft maturation and signal intensity quantified by the signal-to-noise quotient (SNQ) on sagittal-oblique proton density-weighted fat-suppressed MRI images, calculated using the posterior cruciate ligament (PCL) and background noise.","12 months after surgery",{"measure":22,"description":23,"timeFrame":20},"Structural Integrity and Graft Continuity on Postoperative MRI","Evaluation of the reconstructed ACL graft structural continuity, categorized as intact, partial tear, or complete tear based on 12-month postoperative MRI findings.",{"measure":25,"description":26,"timeFrame":27},"Knee Pain Assessed by Visual Analog Scale (VAS)","Patient-reported pain severity measured on a Visual Analog Scale ranging from 0 (no pain) to 10 (worst imaginable pain).","Preoperative baseline, and 6, 12, and 24 months after surgery",{"measure":29,"description":30,"timeFrame":27},"International Knee Documentation Committee (IKDC) Subjective Knee Score","Self-reported knee symptoms, function, and sports activities assessed using the IKDC Subjective Knee Evaluation Form. Scores range from 0 to 100, where higher scores indicate higher levels of function and lower levels of symptoms.",{"measure":32,"description":33,"timeFrame":27},"Lysholm Knee Scoring Scale","Evaluates knee function and daily activity symptoms (limp, support, locking, instability, pain, swelling, stair climbing, squatting). Scores range from 0 to 100, with higher scores reflecting better knee function.",{"measure":35,"description":36,"timeFrame":27},"Tegner Activity Scale","Assesses the patient's activity and sports participation level. Scores range from 0 (sick leave or disability due to knee injury) to 10 (participation in competitive sports at national\u002Finternational elite level). Higher scores indicate higher physical activity levels.",null,{"allocation":39,"interventionModel":40,"interventionModelDescription":41,"primaryPurpose":42,"observationalModel":37,"timePerspective":37,"maskingInfo":43},"NA","SINGLE_GROUP","A single-arm prospective cohort study evaluating clinical, radiological, and arthroscopic outcomes in patients undergoing primary ACL reconstruction augmented with BioBrace.","TREATMENT",{"masking":44,"maskingDescription":45,"whoMasked":37},"NONE","Participants are masked to the allocated drilling technique. Assessors of secondary imaging, arthroscopic, and histological outcomes are masked to allocation and evaluate coded participant information. The operating surgeon is aware of allocation.","The BioBrace® Reinforced BioInductive Implant is a bioresorbable scaffold composed of type I bovine collagen and poly-L-lactic acid (PLLA) microfilaments designed to provide mechanical reinforcement and facilitate tissue remodeling during graft healing. In this study, 30 skeletal mature patients receiving BioBrace-augmented primary ACL reconstruction will be evaluated preoperatively and postoperatively at 3, 6, 12, and 24 months. Objective anterior and rotational stability will be measured using the KT-2000 arthrometer (side-to-side difference, SSD) and the pivot-shift test. Patient-reported outcome measures (VAS for pain, IKDC subjective score, Lysholm score, and Tegner activity scale) will be recorded. Graft maturation will be assessed via 12-month postoperative MRI (measuring signal-to-noise quotient, SNQ, and structural integrity) and second-look arthroscopy during tibial implant removal at 24 months (using Ahn's Graft Maturation Score, GMS). Adverse events, graft failure\u002Fre-tear, and reoperation rates will be monitored throughout the 24-month follow-up period.",[48],{"label":49,"type":50,"description":51,"interventionNames":52},"2-mm subchondral drilling","EXPERIMENTAL","Patients undergoing primary anterior cruciate ligament (ACL) reconstruction augmented with the BioBrace® Reinforced BioInductive Implant (5 x 250 mm). The implant is folded and incorporated alongside the prepared ACL graft, then fixed into the femoral and tibial bone tunnels. Concomitant meniscal surgery (repair or partial meniscectomy) or anterolateral ligament (ALL) reconstruction is performed when clinically indicated.",[53],"Device: BioBrace® Reinforced BioInductive Implant",[55],{"type":56,"name":57,"description":58,"armGroupLabels":59,"otherNames":60},"DEVICE","BioBrace® Reinforced BioInductive Implant","BioBrace® Reinforced BioInductive Implant (5 x 250 mm; CONMED Corporation) is used as an augment for primary ACL reconstruction. The bioinductive scaffold is whipstitched at both ends, folded in half, positioned alongside the autograft\u002Fallograft tendon, and passed through femoral and tibial tunnels for standard fixation to reinforce early mechanical stability and facilitate graft maturation.",[49],[61,62,63],"BioBrace","Bioinductive collagen-PLLA implant","BioBrace-augmented primary ACL reconstruction",[65,70],{"name":66,"role":67,"phone":68,"phoneExt":37,"email":69},"Sung-Hwan Kim, M.D., Ph.D.","CONTACT","+82-2-2228-2180","orthohwan@gmail.com",{"name":71,"role":67,"phone":72,"phoneExt":37,"email":73},"Seung Hoon Baik, Clinical Fellow","+82-10-6691-8492","bsh4508@gmail.com",{"type":75,"investigatorFullName":37,"investigatorTitle":37,"investigatorAffiliation":37,"oldNameTitle":37,"oldOrganization":37},"SPONSOR","100662699","clinical-and-biological-outcomes-of-biobrace-augmented-acl-reconstruction-100662699",false,"NCT07906860","Clinical and Biological Outcomes of BioBrace-Augmented ACL Reconstruction","Clinical and Biological Outcomes of BioBrace®-Augmented Anterior Cruciate Ligament Reconstruction: A Prospective Cohort Study","Inclusion Criteria:\n\n1. Patients with anterior cruciate ligament (ACL) injury confirmed by physical examination and MRI, scheduled for primary ACL reconstruction.\n2. Skeletally mature patients who are suitable for standard ACL reconstruction without physeal-sparing techniques.\n3. Patients who, during routine clinical practice prior to study enrollment, have already voluntarily decided to undergo BioBrace®-augmented primary ACL reconstruction after receiving full explanations regarding the purpose, expected benefits, risks, limitations of evidence, uncovered costs, and alternative treatment options.\n4. Patients who have received adequate explanation of the study objectives, procedures, potential risks, and benefits, and voluntarily signed written informed consent.\n5. Adults aged 19 years or older.\n\nExclusion Criteria:\n\n1. Revision ACL reconstruction in the affected knee.\n2. History of prior ligament reconstruction or major knee surgery in the ipsilateral knee that may significantly influence study outcomes.\n3. Contralateral knee with ACL tear, ACL deficiency, prior ACL reconstruction, or major knee surgery that may affect outcome assessment.\n4. Multi-ligament injuries requiring simultaneous ligament reconstruction other than the ACL.\n5. Requirement for concomitant major procedures that may affect clinical outcomes (e.g., osteotomy, meniscus allograft transplantation, cartilage restoration) other than standard meniscal repair or partial meniscectomy.\n6. Advanced osteoarthritis of the knee joint.\n7. Concomitant periarticular fracture of the knee requiring surgery, or a history of surgery for such fractures.\n8. Active infection, inflammatory arthritis, neuromuscular disorders, or other systemic conditions that may significantly affect tendon healing and postoperative rehabilitation.\n9. Known hypersensitivity or allergy to bovine-derived materials, polyethylene glycol, poly-L-lactic acid (PLLA), or any component of the BioBrace® implant.\n10. Contraindications to magnetic resonance imaging (MRI).\n11. Inability to adhere to the planned rehabilitation protocol or attend 24-month follow-up visits.\n12. Inability to provide voluntary written informed consent.\n13. Age younger than 19 years.\n14. Other medical or clinical conditions deemed inappropriate for participation by the principal investigator.","ALL","19 Years",{"count":86,"type":87},30,"ESTIMATED","INTERVENTIONAL",[39],"This prospective, single-center, single-arm observational cohort study aims to evaluate the clinical, radiological, and arthroscopic outcomes and safety of primary anterior cruciate ligament (ACL) reconstruction augmented with the BioBrace® Reinforced BioInductive Implant. A total of 30 patients who decided to undergo BioBrace-augmented ACL reconstruction in routine clinical practice will be followed for up to 24 months postoperatively. Knee stability, graft maturation via MRI and second-look arthroscopy, patient-reported outcomes, and complications will be assessed.",[92,93],"Anterior Cruciate Ligament Injuries","Anterior Cruciate Ligament Rupture",[95,61,96,97,98,99],"Anterior Cruciate Ligament Reconstruction","Bioinductive Implant","Graft Healing","KT-2000","Second-Look Arthroscopy","NOT_YET_RECRUITING","2026-10-25",{"date":103,"type":104},"2026-10-30","ACTUAL",{"date":106,"type":87},"2026-11-01",{"date":108,"type":87},"2029-04-30",{"name":5,"class":6}]