[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100662971":3},{"organization":4,"outcomesModule":7,"designInfo":99,"detailedDescription":98,"studyPopulation":102,"armGroups":98,"interventions":103,"overallOfficials":98,"centralContacts":111,"locations":98,"responsibleParty":120,"collaborators":98,"id":122,"slug":123,"hasResults":124,"nctId":125,"briefTitle":126,"officialTitle":127,"acronym":128,"eligibilityCriteria":129,"healthyVolunteers":124,"sex":130,"minAge":131,"maxAge":98,"enrollmentInfo":132,"targetDuration":135,"studyType":136,"phases":98,"briefSummary":137,"conditions":138,"keywords":140,"overallStatus":143,"whyStopped":98,"lastUpdateSubmitDate":144,"lastUpdatePostDateStruct":145,"startDateStruct":148,"completionDateStruct":150,"leadSponsor":152,"locationsCount":98},{"fullName":5,"class":6},"Vascutek Ltd.","INDUSTRY",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":98},[9],{"measure":10,"description":11,"timeFrame":12},"Primary Endpoint","The primary endpoint is a composite endpoint defined as the absence of the following events through 12-months post-procedure:\n\n* All-cause mortality\n* Aortic rupture in the treated segment\n* Unanticipated device-related secondary intervention (endovascular or open surgical)","1 year",[14,18,22,25,28,31,34,37,40,43,46,49,53,56,58,62,65,68,71,74,77,80,83,86,89,92,95],{"measure":15,"description":16,"timeFrame":17},"Individual Components of Primary Endpoint: All-cause mortality","Rate of all-cause mortality","The secondary endpoints will be measured at each standard of care follow-up timepoint from discharge\u002F30 days through to completion of follow up (approx. 10 years).",{"measure":19,"description":20,"timeFrame":21},"Individual Components of Primary Endpoint: Aortic rupture in the treated segment","Rate of aortic rupture in the treated segment","The secondary endpoints will be measured at each standard of care follow-up timepoint from the procedure\u002FDay 1 through to completion of follow up (approx. 10 years).",{"measure":23,"description":24,"timeFrame":21},"Individual Components of Primary Endpoint: Unanticipated device-related secondary intervention (endovascular or open surgical)","Rate of unanticipated device-related secondary intervention (endovascular or open surgical)",{"measure":26,"description":27,"timeFrame":21},"Major Adverse Events: Stroke","Rate of Stroke of any type, including transient ischemia attack (TIA)",{"measure":29,"description":30,"timeFrame":21},"Major Adverse Events: Myocardial Infarction (MI)","Rate of Myocardial Infarction (MI)",{"measure":32,"description":33,"timeFrame":21},"Major Adverse Events: Paraplegia\u002FParaparesis","Rate of Paraplegia\u002FParaparesis",{"measure":35,"description":36,"timeFrame":21},"Major Adverse Events: Respiratory Failure","Rate of Respiratory Failure",{"measure":38,"description":39,"timeFrame":21},"Major Adverse Events: Renal Failure","Rate of Renal Failure",{"measure":41,"description":42,"timeFrame":21},"Major Adverse Events: Bowel Ischemia","Rate of Bowel Ischemia",{"measure":44,"description":45,"timeFrame":21},"Dissection Endpoints: Entry Flow Type","Entry Flow (Type I, Type II and Type R)",{"measure":47,"description":48,"timeFrame":21},"Dissection Endpoints: Remodelling","Positive aortic remodelling in the treated segment(s), defined as either:\n\n* false lumen reduction in maximal diameter or volume and no growth in total aortic diameter or volume\n* true lumen expansion in maximal diameter or volume and no growth in total aortic diameter or volume; or\n* total aortic maximal diameter reduction with variable changes in true and false lumen diameters.",{"measure":50,"description":51,"timeFrame":52},"Clinical Utility Measures","Procedure time (hours)","Perioperative",{"measure":50,"description":54,"timeFrame":55},"Time in the Intensive Care Unit (ICU) (days)","Discharge\u002F30 days",{"measure":50,"description":57,"timeFrame":55},"Time in Hospital (days)",{"measure":59,"description":60,"timeFrame":61},"Technical Success","Technical Success is a composite endpoint evaluated at the index procedure by the implanting physician and is defined as follows:\n\n* Successful access to the arterial system\n* Successful delivery and accurate placement of the implant in the planned location without unplanned vessel coverage\n* Absence of device deformations requiring unplanned placement of an additional device (at the index procedure)\n* Patency of the implant (including branches) without significant twist, kinks or obstruction\n* Successful retrieval of the device delivery system (without unanticipated corrective action related to the withdrawal)\n* No need for unanticipated corrective intervention or emergency surgery to achieve the above goals Technical success can include the use of additional modular components, stents, or angioplasty and adjunctive surgical procedures at the time of the primary procedure.","Day 1",{"measure":63,"description":64,"timeFrame":21},"Lesion- and\u002For device-related secondary intervention","Rate of lesion- and\u002For device-related secondary intervention",{"measure":66,"description":67,"timeFrame":21},"Lesion related mortality","Rate of Lesion-related mortality",{"measure":69,"description":70,"timeFrame":21},"Intraluminal Thrombosis (ILT)","Rate of Intraluminal Thrombosis (ILT)",{"measure":72,"description":73,"timeFrame":21},"Device occlusion","Rate of Device occlusion",{"measure":75,"description":76,"timeFrame":21},"Device infection","Rate of device infection",{"measure":78,"description":79,"timeFrame":21},"New aortic dissection","Incidence of new aortic dissection",{"measure":81,"description":82,"timeFrame":21},"Device migration","Device migration (\\>10mm movement of stented portion of the implant)",{"measure":84,"description":85,"timeFrame":21},"All endoleaks","Rate of all endoleaks",{"measure":87,"description":88,"timeFrame":21},"Aortic expansion","Rate of aortic expansion (increase of \\>5mm in diameter \\[of the treated aortic segment\\] when compared with the first post-procedural imaging)",{"measure":90,"description":91,"timeFrame":21},"Fistula formation","Rate of fistula formation",{"measure":93,"description":94,"timeFrame":21},"Pseudoaneurysm in the treated segment","Rate of pseudoaneurysm in the treated segment",{"measure":96,"description":97,"timeFrame":21},"Loss of device integrity","Loss of device integrity (i.e., stent fractures, device kinking, device twisting)",null,{"allocation":98,"interventionModel":98,"interventionModelDescription":98,"primaryPurpose":98,"observationalModel":100,"timePerspective":101,"maskingInfo":98},"COHORT","PROSPECTIVE","Patients with damaged or diseased aortic arch and descending aorta in cases such as aneurysm and dissection, with or without involvement of the ascending aorta, who undergo treatment with a Thoraflex Hybrid device.",[104],{"type":105,"name":106,"description":107,"armGroupLabels":98,"otherNames":108},"DEVICE","Thoraflex Hybrid","Aortic repair with Thoraflex Hybrid device.",[109,110],"Frozen Elephant Trunk","Hybrid Aortic Repair",[112,117],{"name":113,"role":114,"phone":115,"phoneExt":98,"email":116},"Clinical Study Manager","CONTACT","+441418125555","r.smith1@terumoaortic.com",{"name":118,"role":114,"phone":98,"phoneExt":98,"email":119},"Study Mailbox","taukcheetahstudy@terumoaortic.com",{"type":121,"investigatorFullName":98,"investigatorTitle":98,"investigatorAffiliation":98,"oldNameTitle":98,"oldOrganization":98},"SPONSOR","100662971","clinical-health-outcomes-evaluation-of-terumo-aortic-hybrid-devices-100662971",false,"NCT07911163","Clinical Health Outcomes Evaluation of Terumo Aortic Hybrid Devices","Clinical HEalth Outcomes Evaluation of Terumo Aortic Hybrid Devices","CHEETAH","Inclusion Criteria:\n\n1. Patient is aged 18 years or older on date of consent\n2. Indication for open surgical repair using a Thoraflex Hybrid graft\n3. Ability to provide informed consent\n\n   * Retrospective consent will be permitted in some circumstances. In the event the patient was not consented prior to procedure (e.g., due to admission type or study site personnel availability at the time of pre-procedure), consent may be collected retrospectively immediately after procedure and no later than discharge\n\n     o Where retrospective consent is used, no data will be collected in the study electronic data capture (EDC) prior to written informed consent being obtained\n   * If the subject is unable to provide consent (for example, in emergency treatment; or if they are 18 years old but do not meeting the minimum legal age for informed consent in their region), then the consent of their \u002Flegally designated representative (LDR)\u002Flegally authorized representative (LAR) is permitted (dependent on local IEC\u002FIRB approvals).\n4. Willingness to comply with standard of care follow-up visits\n\nExclusion Criteria:\n\n1. Patient is unable or unwilling to comply with standard of care follow-up regimen\n2. Patient is contraindicated per the instructions for use (IFU)\n3. Patient has any other medical, social or psychological condition which, in the opinion of the Investigator, could compromise the patient's ability to comply with study evaluations (as outlined in the protocol)","ALL","18 Years",{"count":133,"type":134},150,"ESTIMATED","10 Years","OBSERVATIONAL","This prospective, non-interventional, study of Thoraflex Hybrid devices is part of Terumo Aortic's clinical development and Post Market Clinical Follow-Up (PMCF) plan and will provide insights into both the short- and long-term clinical outcomes of all commercially available Thoraflex Hybrid devices.",[139],"Aortic Aneurysm and Dissection",[106,141,142],"Aortic Aneurysm","Aortic Dissection","NOT_YET_RECRUITING","2026-10-27",{"date":146,"type":147},"2026-11-02","ACTUAL",{"date":149,"type":134},"2027-05",{"date":151,"type":134},"2039-05",{"name":5,"class":6}]