[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100666892":3},{"organization":4,"outcomesModule":7,"designInfo":42,"detailedDescription":50,"studyPopulation":41,"armGroups":51,"interventions":66,"overallOfficials":41,"centralContacts":72,"locations":41,"responsibleParty":81,"collaborators":41,"id":83,"slug":84,"hasResults":85,"nctId":86,"briefTitle":87,"officialTitle":88,"acronym":89,"eligibilityCriteria":90,"healthyVolunteers":91,"sex":92,"minAge":93,"maxAge":41,"enrollmentInfo":94,"targetDuration":41,"studyType":97,"phases":98,"briefSummary":100,"conditions":101,"keywords":103,"overallStatus":112,"whyStopped":41,"lastUpdateSubmitDate":113,"lastUpdatePostDateStruct":114,"startDateStruct":117,"completionDateStruct":119,"leadSponsor":121,"locationsCount":41},{"fullName":5,"class":6},"Fondazione G.B. Bietti, IRCCS","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":25,"otherOutcomes":41},[9,13,16,19,22],{"measure":10,"description":11,"timeFrame":12},"Sensitivity of GlaukomAI for Glaucoma Detection","Proportion of participants with glaucoma correctly identified by GlaukomAI, compared with the reference classification established by three glaucoma specialists. Sensitivity will be expressed as a percentage with a 95% confidence interval.","Baseline (single visit or within 1 week)",{"measure":14,"description":15,"timeFrame":12},"Specificity of GlaukomAI for Glaucoma Detection","Proportion of participants without glaucoma correctly identified by GlaukomAI, compared with the reference classification established by three glaucoma specialists. Specificity will be expressed as a percentage with a 95% confidence interval.",{"measure":17,"description":18,"timeFrame":12},"Positive Predictive Value of GlaukomAI","Proportion of positive GlaukomAI classifications corresponding to glaucoma according to the expert reference standard. Positive predictive value will be expressed as a percentage with a 95% confidence interval.",{"measure":20,"description":21,"timeFrame":12},"Negative Predictive Value of GlaukomAI","Proportion of negative GlaukomAI classifications corresponding to the absence of glaucoma according to the expert reference standard. Negative predictive value will be expressed as a percentage with a 95% confidence interval.",{"measure":23,"description":24,"timeFrame":12},"Area Under the ROC Curve of GlaukomAI","Area under the receiver operating characteristic curve (AUC) describing the diagnostic discrimination of GlaukomAI compared with the expert reference standard, reported on a scale from 0 to 1 with a 95% confidence interval.",[26,29,32,35,38],{"measure":27,"description":28,"timeFrame":12},"Sensitivity of GlaukomAI for Specialist Referral","Percentage of participants requiring specialist referral correctly classified as referable by GlaukomAI, compared with the reference standard established by glaucoma specialists.",{"measure":30,"description":31,"timeFrame":12},"Specificity of GlaukomAI for Specialist Referral","Percentage of participants not requiring specialist referral correctly classified as non-referable by GlaukomAI, compared with the reference standard established by glaucoma specialists.",{"measure":33,"description":34,"timeFrame":12},"Diagnostic Agreement Between GlaukomAI and the Expert Reference Standard","Agreement between GlaukomAI classification and the classification established by the panel of three glaucoma specialists, measured using Cohen's kappa coefficient.",{"measure":36,"description":37,"timeFrame":12},"Referral Agreement Between Non-Specialist Ophthalmologists and the Expert Reference Standard","Agreement between referral recommendations made by non-glaucoma-specialist ophthalmologists and the reference standard established by glaucoma specialists, measured using Cohen's kappa coefficient.",{"measure":39,"description":40,"timeFrame":12},"Diagnostic Performance Across Participant Subgroups","Evaluation of GlaukomAI diagnostic performance stratified by age, sex, glaucoma severity (early, moderate, advanced), and fundus image quality using logistic regression analyses.",null,{"allocation":43,"interventionModel":44,"interventionModelDescription":41,"primaryPurpose":45,"observationalModel":41,"timePerspective":41,"maskingInfo":46},"NON_RANDOMIZED","PARALLEL","DIAGNOSTIC",{"masking":47,"maskingDescription":41,"whoMasked":48},"SINGLE",[49],"OUTCOMES_ASSESSOR","GlaukomAIcare is a prospective, single-center, interventional clinical investigation designed to evaluate the diagnostic performance of Sens-vue GlaukomAI, an artificial intelligence-based medical software system for glaucoma screening and referral assessment.\n\nThe investigational diagnostic and referral functions are not covered by the software's current Class I CE marking.\n\nThe study consists of two complementary phases.\n\n\\*\\*Phase 1: Prospective Cross-Sectional Diagnostic Accuracy Study\\*\\*\n\nA total of 200 participants will be enrolled, including 100 patients with diagnosed glaucoma and 100 healthy controls.\n\nThe diagnostic performance of GlaukomAI will be evaluated against a reference standard established by three glaucoma specialists using fundus photography, optical coherence tomography (OCT), visual field examinations, and clinical findings.\n\nEach specialist will independently classify participants as healthy, glaucoma suspect, or glaucoma. The final reference classification will be determined by majority agreement.\n\nGlaukomAI will independently analyze pseudonymized optic disc photographs and classify participants using the same diagnostic categories.\n\n\\*\\*Phase 2: Prospective Referral Accuracy Assessment\\*\\*\n\nA total of 1,000 consecutive patients attending the ophthalmology outpatient clinic of IRCCS Fondazione G.B. Bietti for any clinical reason will be enrolled.\n\nThe GlaukomAI system will analyze fundus photographs and provide a binary referral recommendation:\n\n* Referable: glaucoma or suspected glaucoma requiring specialist assessment.\n* Non-referable: no specialist referral required.\n\nOphthalmologists without subspecialty expertise in glaucoma will independently assess the same images, blinded to the AI output and reference standard diagnosis.\n\nReferral recommendations will be compared with the classification established by the panel of glaucoma specialists.\n\n\\*\\*Study Procedures\\*\\*\n\nFollowing written informed consent, participants will undergo:\n\n* Medical and ophthalmological history assessment.\n* Best-corrected visual acuity measurement.\n* Slit-lamp examination.\n* Intraocular pressure measurement using Goldmann applanation tonometry.\n* Visual field testing using Humphrey 24-2 SITA Standard or SITA Faster.\n* Fundus examination.\n* Optic disc photography using the iCare DRS Plus system.\n* OCT assessment of retinal nerve fiber layer and ganglion cell complex thickness using Cirrus HD-OCT.\n\nAll examinations will be completed during one visit or, if necessary, two visits within one week.\n\n\\*\\*Outcome Assessment\\*\\*\n\nDiagnostic performance will be assessed through sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve.\n\nAgreement between diagnostic methods will be evaluated using Cohen's kappa coefficient. Additional analyses will examine performance according to age, sex, glaucoma severity, and image quality.\n\nBoth eyes may be included in the analysis, with statistical methods accounting for correlation between eyes from the same participant.\n\nThe overall study duration is 24 months, including an 18-month enrollment period.",[52,58,62],{"label":53,"type":54,"description":55,"interventionNames":56},"Glaucoma Patients (Phase 1)","EXPERIMENTAL","Patients with an established diagnosis of glaucoma receiving pharmacological treatment. Participants will undergo comprehensive ophthalmological examinations and fundus photography. Images will be analyzed using GlaukomAI, and the diagnostic classification will be compared with the reference standard established by three glaucoma specialists.",[57],"Device: Sens-vue GlaukomAI",{"label":59,"type":54,"description":60,"interventionNames":61},"Healthy Controls (Phase 1)","Healthy participants without ocular diseases who will undergo ophthalmological examinations, fundus photography, visual field testing, and OCT. Fundus images will be analyzed using GlaukomAI to evaluate its ability to distinguish healthy eyes from glaucomatous eyes.",[57],{"label":63,"type":54,"description":64,"interventionNames":65},"Consecutive Ophthalmology Patients (Phase 2)","Consecutive patients attending the ophthalmology outpatient clinic for any clinical reason. Participants will undergo ophthalmological examinations and fundus photography. GlaukomAI will generate a binary referral recommendation, which will be compared with independent assessments by non-glaucoma-specialist ophthalmologists and the reference classification established by glaucoma experts.",[57],[67],{"type":68,"name":69,"description":70,"armGroupLabels":71,"otherNames":41},"DEVICE","Sens-vue GlaukomAI","Sens-vue GlaukomAI is an artificial intelligence-based medical software system that analyzes pseudonymized fundus photographs to identify signs of glaucoma.\n\nIn Phase 1, the software classifies images as healthy, glaucoma suspect, or glaucoma.\n\nIn Phase 2, the software provides a binary referral recommendation (referable or non-referable).\n\nThe investigational diagnostic and referral functions are not covered by the current Class I CE marking. The software output will be compared with an independent reference standard established by a panel of three glaucoma specialists.",[63,53,59],[73,78],{"name":74,"role":75,"phone":76,"phoneExt":41,"email":77},"Francesco Oddone, MD","CONTACT","+390684009442","francesco.oddone@fondazionebietti.it",{"name":79,"role":75,"phone":41,"phoneExt":41,"email":80},"Carmela Carnevale, MD","carmela.carnevale@fondazionebietti.it",{"type":82,"investigatorFullName":41,"investigatorTitle":41,"investigatorAffiliation":41,"oldNameTitle":41,"oldOrganization":41},"SPONSOR","100666892","clinical-validation-of-an-ai-based-system-for-glaucoma-screening-and-diagnosis-100666892",false,"NCT07962292","Clinical Validation of an AI-Based System for Glaucoma Screening and Diagnosis","GlaukomAI: Clinical Validation of an Artificial Intelligence-Based System for Early Glaucoma Screening and Diagnosis - A Case-Control Study and Referral Accuracy Assessment","GlaukomAIcare","\\*\\*Inclusion Criteria:\\*\\*\n\nGeneral inclusion criteria:\n\n* Age \\>18 years.\n* Freely given informed consent obtained before study initiation.\n* Ability to understand and willingness to follow study instructions and likely to complete all required study visits and procedures.\n\nAdditional inclusion criteria for glaucoma patients (Phase 1):\n\n* Diagnosis of any type of glaucoma, including primary open-angle glaucoma, primary angle-closure glaucoma, or secondary glaucoma.\n* Current pharmacological treatment for glaucoma.\n\nAdditional inclusion criteria for healthy controls (Phase 1):\n\n* Absence of ocular diseases.\n* Normal optic disc appearance on clinical examination.\n* Intraocular pressure \\\u003C21 mmHg.\n* Visual field examination and optical coherence tomography (OCT) within normal limits.\n\nPhase 2 population:\n\n\\- Consecutive patients attending the ophthalmology outpatient clinic of IRCCS Fondazione G.B. Bietti for any clinical reason, provided they meet the general eligibility criteria.\n\n\\*\\*Exclusion Criteria:\\*\\*\n\n* Presence of ocular media opacities preventing the acquisition of adequate-quality fundus images, including advanced cataract, vitreous hemorrhage, or severe corneal opacities.\n* Retinal or optic nerve diseases that could confound glaucoma diagnosis, including non-glaucomatous optic neuropathies (ischemic, inflammatory, or compressive), moderate-to-severe diabetic retinopathy, advanced age-related macular degeneration, or retinal vascular occlusions.\n* Any ocular surgery within the previous 3 months.\n* Inability to cooperate with visual field testing.",true,"ALL","18 Years",{"count":95,"type":96},1200,"ESTIMATED","INTERVENTIONAL",[99],"NA","The GlaukomAIcare study aims to evaluate an artificial intelligence (AI)-based system designed to help identify glaucoma, an eye disease that can damage the optic nerve and cause irreversible vision loss.\n\nThe study will assess how accurately GlaukomAI identifies glaucoma compared with a diagnosis established by three glaucoma specialists using eye examinations, retinal photographs, optical coherence tomography (OCT), and visual field tests.\n\nThe study consists of two phases. The first phase will compare patients with glaucoma and healthy participants to evaluate the diagnostic accuracy of the AI system. The second phase will assess whether the system can help ophthalmologists who are not glaucoma specialists identify patients who should be referred for specialist evaluation.\n\nParticipants will undergo ophthalmological examinations and imaging assessments. All examinations will be completed during one visit or, if necessary, two consecutive visits within one week.\n\nThe results may help determine whether AI-based technology can support earlier glaucoma detection and improve referral decisions in ophthalmological practice.",[102],"Glaucoma",[104,105,106,107,108,109,110,111],"Artificial Intelligence","Glaucoma Screening","Glaucoma Diagnosis","Deep Learning","Diagnostic Accuracy","Fundus Photography","Optical Coherence Tomography","Referral Accuracy","NOT_YET_RECRUITING","2026-11-20",{"date":115,"type":116},"2026-11-27","ACTUAL",{"date":118,"type":96},"2026-12-19",{"date":120,"type":96},"2028-06-15",{"name":5,"class":6}]