[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100666843":3},{"organization":4,"outcomesModule":7,"designInfo":34,"detailedDescription":44,"studyPopulation":33,"armGroups":45,"interventions":58,"overallOfficials":66,"centralContacts":70,"locations":79,"responsibleParty":93,"collaborators":33,"id":95,"slug":96,"hasResults":97,"nctId":98,"briefTitle":99,"officialTitle":100,"acronym":33,"eligibilityCriteria":101,"healthyVolunteers":97,"sex":102,"minAge":103,"maxAge":104,"enrollmentInfo":105,"targetDuration":33,"studyType":108,"phases":109,"briefSummary":111,"conditions":112,"keywords":114,"overallStatus":118,"whyStopped":33,"lastUpdateSubmitDate":119,"lastUpdatePostDateStruct":120,"startDateStruct":123,"completionDateStruct":125,"leadSponsor":127,"locationsCount":128},{"fullName":5,"class":6},"Antalya City Hospital","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":33},[9],{"measure":10,"description":11,"timeFrame":12},"Absolute Femoral-to-Radial Mean Arterial Pressure Difference at Cardiopulmonary Bypass Weaning","The primary outcome is the absolute difference between simultaneously measured femoral arterial mean arterial pressure (FA-MAP) and radial arterial mean arterial pressure (RA-MAP) at cardiopulmonary bypass (CPB) weaning, calculated as \\|FA-MAP - RA-MAP\\| and expressed in mmHg. This outcome will be compared between the distal radial and conventional radial artery catheterization groups. Lower absolute differences indicate closer agreement with femoral arterial pressure measurements.","At cardiopulmonary bypass (CPB) weaning, during the intraoperative period.",[14,18,21,25,29],{"measure":15,"description":16,"timeFrame":17},"First-Attempt Catheterization Success Rate","The proportion of patients in whom successful arterial catheterization is achieved on the first needle insertion, confirmed by an adequate arterial pressure waveform.","During initial arterial catheterization, before surgery.",{"measure":19,"description":20,"timeFrame":17},"Number of Arterial Catheterization Attempts","The total number of needle insertion attempts required to achieve successful arterial catheterization in each study group.",{"measure":22,"description":23,"timeFrame":24},"Time to Hemostasis After Arterial Catheter Removal","Time required to achieve complete hemostasis after removal of the arterial catheter, measured in seconds from the initiation of manual compression until cessation of bleeding. Hemostasis time will be compared between the distal radial and conventional radial artery catheterization groups.","From initiation of manual compression immediately after arterial catheter removal until complete hemostasis, assessed for up to 10 minutes.",{"measure":26,"description":27,"timeFrame":28},"Intraoperative Catheter Dysfunction","The proportion of patients experiencing arterial catheter dysfunction during surgery, defined as persistent arterial waveform damping or distortion, unreliable blood pressure measurements inconsistent with the clinical condition, or loss of catheter functionality. Catheter dysfunction will be compared between the distal radial and conventional radial artery catheterization groups.","From arterial catheter placement until the end of surgery (intraoperative period).",{"measure":30,"description":31,"timeFrame":32},"Total Arterial Catheterization Time","The total arterial catheterization time will be recorded in seconds for each patient. The duration of each catheterization attempt will be measured separately, starting immediately before needle insertion and ending when a satisfactory arterial pressure waveform is observed on the monitor for successful attempts, or when the attempt is terminated for unsuccessful attempts. A maximum of two palpation-guided attempts will be performed, followed by a third ultrasound-guided attempt if necessary. The total catheterization time will be calculated as the sum of the active durations of all attempts, excluding intervals between attempts and ultrasound localization time before needle insertion. Total catheterization time will be compared between the distal radial and conventional radial artery catheterization groups.","From the first needle insertion until completion or termination of arterial catheterization, assessed for up to 10 minutes before cardiopulmonary bypass.",null,{"allocation":35,"interventionModel":36,"interventionModelDescription":37,"primaryPurpose":38,"observationalModel":33,"timePerspective":33,"maskingInfo":39},"RANDOMIZED","PARALLEL","Participants will be randomly assigned in a 1:1 ratio to two parallel groups: distal radial artery catheterization or conventional radial artery catheterization. Each participant will undergo only the assigned catheterization technique for the initial arterial access.","SUPPORTIVE_CARE",{"masking":40,"maskingDescription":41,"whoMasked":42},"SINGLE","An independent physician who is unaware of group allocation will assess intraoperative arterial pressure measurements, waveform quality, and radial-to-femoral pressure differences. Additionally, the biostatistician performing the statistical analyses will be blinded to group allocation. The anesthesiologists performing arterial catheterization cannot be blinded due to the anatomical differences between the two techniques.",[43],"OUTCOMES_ASSESSOR","Invasive arterial blood pressure monitoring is essential for hemodynamic management during open cardiovascular surgery involving cardiopulmonary bypass (CPB). Clinically significant differences between peripheral radial and more central femoral arterial pressures may occur during and after CPB, potentially affecting the interpretation of hemodynamic measurements and clinical decision-making.\n\nDistal radial artery catheterization at the anatomical snuffbox has emerged as an alternative to conventional radial artery catheterization at the wrist. However, evidence comparing these two catheterization sites in terms of femoral-to-radial pressure gradients, waveform reliability, catheterization performance, and complications during open cardiovascular surgery remains limited.\n\nThis study is designed as a prospective, single-center, randomized, two-parallel-group clinical trial at Antalya City Hospital, Türkiye. A total of 208 adult patients aged 18-80 years scheduled for elective coronary artery bypass grafting (CABG), valve surgery, or combined CABG and valve surgery requiring CPB will be enrolled.\n\nParticipants will be randomly allocated in a 1:1 ratio to distal radial artery catheterization or conventional radial artery catheterization using a computer-generated randomization sequence. Allocation concealment will be maintained using sequentially numbered, opaque, sealed envelopes.\n\nBefore catheterization, ultrasonography will be used to assess radial artery dimensions, including short-axis and long-axis diameters, arterial depth, and cross-sectional area.\n\nCatheterization will be performed by experienced clinicians under standardized aseptic conditions. The non-dominant upper extremity will be preferred. The first two catheterization attempts will be performed using the palpation-guided technique. If both attempts are unsuccessful, a third attempt will be performed under ultrasound guidance. If the procedure is unsuccessful after three attempts, it will be considered a failure, and catheterization will be attempted in the contralateral extremity.\n\nFollowing successful catheterization, radial and femoral arterial pressure transducers will be standardized for leveling and zeroing. The dynamic response of the monitoring systems will be assessed using the fast-flush (square-wave) test.\n\nSimultaneous systolic, diastolic, and mean arterial pressures from the radial and femoral arteries will be recorded at 12 predefined intraoperative time points: before incision, after sternotomy, before cannulation, before CPB, at 5, 10, 20, and 30 minutes after CPB initiation, at CPB weaning, after protamine administration, at sternal closure, and at the end of surgery.\n\nThe primary outcome will be the absolute femoral-to-radial mean arterial pressure difference (\\|FA-MAP - RA-MAP\\|), expressed in mmHg, at CPB weaning. This outcome will be compared between the distal radial and conventional radial catheterization groups.\n\nSecondary outcomes will include signed and absolute femoral-to-radial systolic, diastolic, and mean arterial pressure differences over time; arterial waveform adequacy; pressure measurement availability; overdamping and underdamping; additional flushing or catheter repositioning requirements; first-attempt and overall catheterization success; number and duration of catheterization attempts; total catheterization time; and ultrasound-derived arterial measurements.\n\nCatheter-related complications, including hematoma, bleeding, vasospasm, posterior arterial wall puncture, catheter dislodgement, and catheter dysfunction, will be recorded. Hematoma severity will be assessed using the modified EASY classification, and bleeding events will be evaluated according to the Bleeding Academic Research Consortium (BARC) criteria. Time to hemostasis following catheter removal will also be measured.\n\nAdditional perioperative variables will include demographic characteristics, comorbidities, vasoactive medication requirements, body temperature, and durations of anesthesia, surgery, aortic cross-clamping, and CPB.\n\nThe primary outcome will be compared between groups using appropriate statistical tests according to data distribution. Repeated intraoperative pressure measurements will be evaluated using mixed-effects models, and agreement between radial and femoral arterial pressure measurements will be assessed using repeated-measures Bland-Altman analysis.\n\nThe findings are expected to provide evidence regarding the influence of radial artery catheterization site on hemodynamic monitoring reliability, procedural performance, and catheter-related safety during open cardiovascular surgery.",[46,52],{"label":47,"type":48,"description":49,"interventionNames":50},"Distal Radial Artery Catheterization","EXPERIMENTAL","Patients randomized to this group will undergo distal radial artery catheterization for continuous invasive arterial blood pressure monitoring during open cardiovascular surgery.",[51],"Procedure: Distal Radial Artery Catheterization",{"label":53,"type":54,"description":55,"interventionNames":56},"Conventional Radial Artery Catheterization","ACTIVE_COMPARATOR","Patients randomized to this group will undergo conventional radial artery catheterization for continuous invasive arterial blood pressure monitoring during open cardiovascular surgery.",[57],"Procedure: Conventional Radial Artery Catheterization",[59,63],{"type":60,"name":47,"description":61,"armGroupLabels":62,"otherNames":33},"PROCEDURE","Distal radial artery catheterization will be performed at the anatomical snuffbox for continuous invasive arterial blood pressure monitoring during elective open cardiovascular surgery with cardiopulmonary bypass. The non-dominant upper extremity will be preferred. Before catheterization, arterial diameter, depth, and cross-sectional area will be assessed by ultrasonography. The first two catheterization attempts will be performed using the palpation-guided Seldinger technique under standard aseptic conditions. If unsuccessful, a third attempt will be performed under ultrasound guidance. If catheterization remains unsuccessful after three attempts, the procedure will be recorded as a failure, and catheterization will be attempted in the contralateral extremity.",[47],{"type":60,"name":53,"description":64,"armGroupLabels":65,"otherNames":33},"Conventional radial artery catheterization will be performed at the wrist for continuous invasive arterial blood pressure monitoring during elective open cardiovascular surgery with cardiopulmonary bypass. The non-dominant upper extremity will be preferred. Before catheterization, arterial diameter, depth, and cross-sectional area will be assessed by ultrasonography. The first two catheterization attempts will be performed using the palpation-guided Seldinger technique under standard aseptic conditions. If unsuccessful, a third attempt will be performed under ultrasound guidance. If catheterization remains unsuccessful after three attempts, the procedure will be recorded as a failure, and catheterization will be attempted in the contralateral extremity.",[53],[67],{"name":68,"affiliation":5,"role":69},"Feray Akgül Erdil, MD","PRINCIPAL_INVESTIGATOR",[71,76],{"name":72,"role":73,"phone":74,"phoneExt":33,"email":75},"Başak Göktaş Dörtyol, MD","CONTACT","+905375419903","basakgoktas07@gmail.com",{"name":68,"role":73,"phone":77,"phoneExt":33,"email":78},"+905325595136","feray.erdil@inonu.edu.tr",[80],{"facility":5,"status":33,"city":81,"state":81,"zip":82,"country":83,"countryCode":33,"cosmosGeoPoint":84,"geoPoint":89,"contacts":90},"Antalya","07080","Turkey (Türkiye)",{"type":85,"coordinates":86},"Point",[87,88],30.69556,36.90812,{"lat":88,"lon":87},[91,92],{"name":72,"role":73,"phone":74,"phoneExt":33,"email":75},{"name":68,"role":73,"phone":77,"phoneExt":33,"email":78},{"type":94,"investigatorFullName":33,"investigatorTitle":33,"investigatorAffiliation":33,"oldNameTitle":33,"oldOrganization":33},"SPONSOR","100666843","comparison-of-distal-and-conventional-radial-artery-catheterization-in-open-cardiovascular-surgery-100666843",false,"NCT07961083","Comparison of Distal and Conventional Radial Artery Catheterization in Open Cardiovascular Surgery","Comparison of Distal Radial Artery and Conventional Radial Artery Catheterization in Open Cardiovascular Surgery","Inclusion Criteria:\n\n* Age between 18 and 80 years.\n* Scheduled for elective open cardiovascular surgery.\n* Provision of written informed consent to participate in the study.\n\nExclusion Criteria:\n\n* Emergency surgery.\n* Severe peripheral arterial disease of the upper extremities.\n* History of radial artery surgery or intervention in the relevant extremity.\n* Infection or impaired skin integrity at the catheterization site.\n* Severe coagulopathy or thrombocytopenia.\n* Presence of an arteriovenous fistula.\n* Abnormal Allen's test or inadequate collateral circulation.\n* Failure to provide written informed consent.","ALL","18 Years","80 Years",{"count":106,"type":107},208,"ESTIMATED","INTERVENTIONAL",[110],"NA","This prospective, single-center, randomized controlled trial aims to compare distal radial artery catheterization with conventional radial artery catheterization for invasive arterial blood pressure monitoring in adult patients undergoing elective open cardiovascular surgery with cardiopulmonary bypass (CPB).\n\nA total of 208 patients aged 18-80 years will be randomly assigned in a 1:1 ratio to either distal radial artery catheterization at the anatomical snuffbox or conventional radial artery catheterization at the wrist.\n\nThe primary outcome is the absolute difference in mean arterial pressure (MAP) between the femoral and radial arteries at the time of weaning from cardiopulmonary bypass.\n\nSecondary outcomes include femoral-to-radial arterial pressure differences at predefined intraoperative time points, arterial waveform quality, catheterization success rates, number of attempts, catheterization time, arterial dimensions, catheter function, local complications, and time to hemostasis.\n\nThe study aims to determine whether the catheterization site influences the accuracy and reliability of invasive arterial blood pressure monitoring during open cardiovascular surgery.",[113],"Arterial Catheterization",[47,53,115,116,117],"Open Cardiovascular Surgery","Invasive Arterial Pressure Monitoring","Cardiopulmonary Bypass","NOT_YET_RECRUITING","2026-11-23",{"date":121,"type":122},"2026-11-27","ACTUAL",{"date":124,"type":107},"2027-01-01",{"date":126,"type":107},"2027-07-01",{"name":5,"class":6},1]