[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100652442":3},{"organization":4,"armGroups":7,"interventions":20,"overallOfficials":26,"centralContacts":31,"locations":41,"responsibleParty":61,"collaborators":26,"id":65,"slug":66,"hasResults":67,"nctId":68,"briefTitle":69,"officialTitle":69,"acronym":70,"eligibilityCriteria":71,"healthyVolunteers":67,"sex":72,"minAge":73,"maxAge":74,"enrollmentInfo":75,"targetDuration":26,"studyType":78,"phases":79,"briefSummary":81,"conditions":82,"keywords":84,"overallStatus":44,"whyStopped":26,"lastUpdateSubmitDate":88,"lastUpdatePostDateStruct":89,"startDateStruct":92,"completionDateStruct":94,"leadSponsor":96,"locationsCount":97},{"fullName":5,"class":6},"Allama Iqbal Medical College","OTHER",[8,14],{"label":9,"type":10,"description":11,"interventionNames":12},"Hybrid Ilizarov Technique","EXPERIMENTAL","Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and fixation using a hybrid Ilizarov external fixation technique. Closed or minimally open reduction will be performed under C-arm fluoroscopic guidance, followed by application of a hybrid Ilizarov frame using tensioned Kirschner wires and Schanz screws. Bone graft or bone substitute may be used when clinically indicated.",[13],"Procedure: Hybrid Ilizarov Fixation",{"label":15,"type":16,"description":17,"interventionNames":18},"Locking Plate Technique","ACTIVE_COMPARATOR","Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and internal fixation using a locking compression plate under C-arm fluoroscopic guidance. Appropriate medial and\u002For lateral plate fixation will be performed according to fracture configuration and stability. Bone grafting may be used when clinically indicated.",[19],"Procedure: Locking Plate Fixation",[21,27],{"type":22,"name":23,"description":24,"armGroupLabels":25,"otherNames":26},"PROCEDURE","Hybrid Ilizarov Fixation","Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and fixation using a hybrid Ilizarov external fixation system under C-arm fluoroscopic guidance. Closed or minimally open reduction will be performed as appropriate. The construct will consist of a hybrid Ilizarov C-ring with appropriately tensioned Kirschner wires and Schanz screws. Additional wires or fixation components may be used when required to achieve adequate fracture stability and alignment. Bone graft or bone substitute may be used when clinically indicated.",[9],null,{"type":22,"name":28,"description":29,"armGroupLabels":30,"otherNames":26},"Locking Plate Fixation","Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and internal fixation using a locking compression plate under C-arm fluoroscopic guidance. The appropriate surgical approach and medial and\u002For lateral plate configuration will be selected according to fracture morphology, comminution, and stability. Bone graft or bone substitute may be used when clinically indicated. Postoperative rehabilitation will include early knee range-of-motion exercises, non-weight-bearing ambulation initially, and progressive weight-bearing according to clinical and radiological fracture healing.",[15],[32,37],{"name":33,"role":34,"phone":35,"phoneExt":26,"email":36},"Sajjad Hussain","CONTACT","0333 4077389","prof.sajjadhussain@aimc.edu.pk",{"name":38,"role":34,"phone":39,"phoneExt":26,"email":40},"Montiha Azeem","03479717317","muntahaazeem9@gmail.com",[42],{"facility":43,"status":44,"city":45,"state":46,"zip":47,"country":48,"countryCode":49,"cosmosGeoPoint":50,"geoPoint":55,"contacts":56},"Jinnah Hospital Lahore","RECRUITING","Lahore","Punjab Province","54000","Pakistan","PK",{"type":51,"coordinates":52},"Point",[53,54],74.35071,31.558,{"lat":54,"lon":53},[57,58,59],{"name":33,"role":34,"phone":35,"phoneExt":26,"email":40},{"name":38,"role":34,"phone":26,"phoneExt":26,"email":40},{"name":33,"role":60,"phone":26,"phoneExt":26,"email":26},"PRINCIPAL_INVESTIGATOR",{"type":62,"investigatorFullName":63,"investigatorTitle":64,"investigatorAffiliation":5,"oldNameTitle":26,"oldOrganization":26},"SPONSOR_INVESTIGATOR","Prof. Sajjad Hussain Goraya","Principal Investigator","100652442","comparison-of-functional-outcome-between-locking-plate-technique-versus-hybrid-ilizarov-technique-in-patients-with-schatzker-type-v-and-vi-tibial-plateau-fractures-100652442",false,"NCT07773402","Comparison of Functional Outcome Between Locking Plate Technique Versus Hybrid Ilizarov Technique in Patients With Schatzker Type V and VI Tibial Plateau Fractures","TPF","Inclusion Criteria:\n\n* Patients of either sex.\n* Age between 25 and 50 years.\n* Patients presenting within 2 weeks of sustaining the fracture.\n* Patients diagnosed with complex tibial plateau fractures classified as Schatzker type V or VI.\n* Patients willing to participate in the study.\n* Patients providing written informed consent.\n\nExclusion Criteria:\n\n* Associated ipsilateral limb fractures.\n* Pathological fracture of the tibia.\n* Associated major organ injuries.\n* Psychiatric illness that may interfere with participation or outcome assessment.\n* Refusal to provide informed consent.","ALL","25 Years","50 Years",{"count":76,"type":77},78,"ESTIMATED","INTERVENTIONAL",[80],"NA","This comparative clinical study will evaluate and compare the functional outcomes of patients with Schatzker type V and VI tibial plateau fractures treated using either the locking plate technique or the hybrid Ilizarov technique. Functional outcome will primarily be assessed using the Rasmussen Knee Functional Score. Fracture healing, time to union, non-union, delayed union, and infection will also be assessed and compared between the two treatment groups.",[83],"Tibial Plateau Fracture",[85,86,87],"Tibial plateau fracture","Schatzker type V","Schatzker type VI","2026-08-15",{"date":90,"type":91},"2026-08-19","ACTUAL",{"date":93,"type":77},"2026-08-16",{"date":95,"type":77},"2026-11-16",{"name":63,"class":6},1]