[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100666817":3},{"organization":4,"outcomesModule":7,"designInfo":36,"detailedDescription":39,"studyPopulation":40,"armGroups":41,"interventions":50,"overallOfficials":59,"centralContacts":63,"locations":72,"responsibleParty":85,"collaborators":20,"id":89,"slug":90,"hasResults":91,"nctId":92,"briefTitle":93,"officialTitle":94,"acronym":95,"eligibilityCriteria":96,"healthyVolunteers":91,"sex":97,"minAge":98,"maxAge":20,"enrollmentInfo":99,"targetDuration":20,"studyType":102,"phases":20,"briefSummary":103,"conditions":104,"keywords":107,"overallStatus":113,"whyStopped":20,"lastUpdateSubmitDate":114,"lastUpdatePostDateStruct":115,"startDateStruct":118,"completionDateStruct":120,"leadSponsor":122,"locationsCount":123},{"fullName":5,"class":6},"University of Roma La Sapienza","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":20},[9],{"measure":10,"description":11,"timeFrame":12},"Change in fetal heart rate short-term variation (STV) after device insertion","Within-woman difference in STV (milliseconds) between the 60-minute recording after insertion and the baseline recording, measured by computerised cardiotocography (Dawes-Redman analysis).","Time Frame: Baseline (60 minutes before device insertion) and 60 minutes immediately after device insertion",[14,18,22,24,26,28,30,33],{"measure":15,"description":16,"timeFrame":17},"Change in STV at device removal","Within-woman difference in STV (milliseconds) between the recording at device removal and the baseline recording.","Time Frame: Baseline (60 minutes before device insertion) and 12 hours after insertion (60-minute recording ending at device removal)",{"measure":19,"description":20,"timeFrame":21},"Difference between CRB and Dilapan-S in STV change",null,"Time Frame: Baseline, 60 minutes after device insertion, and 12 hours after insertion (at device removal)",{"measure":23,"description":20,"timeFrame":21},"Change in other computerised CTG parameters",{"measure":25,"description":20,"timeFrame":21},"Presence of cycling",{"measure":27,"description":20,"timeFrame":21},"Dawes-Redman criteria met",{"measure":29,"description":20,"timeFrame":21},"Contractile activity",{"measure":31,"description":20,"timeFrame":32},"Mode of birth and operative birth for suspected fetal compromise","From device insertion to delivery, up to 7 days",{"measure":34,"description":20,"timeFrame":35},"Composite adverse neonatal outcome","From birth to hospital discharge, up to 28 days",{"allocation":20,"interventionModel":20,"interventionModelDescription":20,"primaryPurpose":20,"observationalModel":37,"timePerspective":38,"maskingInfo":20},"COHORT","PROSPECTIVE","Design: prospective, single-centre, observational, non-randomised cohort study with repeated measures in each participant. The choice between CRB and Dilapan-S follows routine clinical practice and is made by the attending obstetrician. The study adds no intervention to standard care other than the standardisation and computerised analysis of three 60-minute CTG recordings.\n\nRecordings: T0, 60 minutes immediately before insertion; T1, 60 minutes started within 5 minutes of the end of insertion; T2, 60 minutes started 11 hours after insertion and ending at removal at 12 hours (early T2 at spontaneous expulsion, membrane rupture, onset of labour or clinical need). All recordings run for the full 60 minutes with the same cCTG system, in semi-recumbent left-lateral tilt, with simultaneous maternal heart rate recording.\n\nParameters: short-term variation, basal fetal heart rate, long-term variation, episodes of high and low variation, presence of cycling, accelerations, decelerations, fetal movements, Dawes-Redman criteria met and time to meet them, and contractile activity on external tocography (contractions per 10 and 60 minutes, duration, tachysystole, prolonged contraction, regular contractions).\n\nSample size: 184 women (92 per device). This gives 80% power to detect a standardised difference of 0.45 in STV change between devices (alpha 0.05), allowing 15% unusable recordings; 66 women give 90% power to detect a 1 ms within-woman change in STV.\n\nAnalysis: paired comparison of STV between T0 and T1; linear mixed-effects models with timepoint, device and timepoint x device interaction and a random intercept per woman, adjusted for gestational age, parity, body mass index, indication, clock time, time since last meal and signal loss; inverse probability of treatment weighting for confounding by indication. Pre-specified subgroups: fetal growth restriction or small-for-gestational-age fetuses, late preterm and post-term gestation, parity.","Consecutive women admitted for induction of labour with an unfavourable cervix and planned mechanical cervical ripening at a tertiary university hospital in Rome, Italy.",[42,46],{"label":43,"type":20,"description":20,"interventionNames":44},"Cervical ripening balloon (CRB)",[45],"Device: Double-balloon cervical ripening catheter",{"label":47,"type":20,"description":20,"interventionNames":48},"Dilapan-S",[49],"Device: Dilapan-S",[51,56],{"type":52,"name":53,"description":54,"armGroupLabels":55,"otherNames":20},"DEVICE","Double-balloon cervical ripening catheter","Standard-care mechanical cervical ripening; each balloon filled with 80 mL saline, left for 12 hours. Not assigned by the study.",[43],{"type":52,"name":47,"description":57,"armGroupLabels":58,"otherNames":20},"Standard-care mechanical cervical ripening with synthetic hygroscopic dilators, number adjusted to cervical admission, left for 12 hours. Not assigned by the study.",[47],[60],{"name":61,"affiliation":5,"role":62},"Giuseppe Rizzo, MD","PRINCIPAL_INVESTIGATOR",[64,68],{"name":61,"role":65,"phone":66,"phoneExt":20,"email":67},"CONTACT","390649971","giuseppe.rizzo@uniroma1.it",{"name":69,"role":65,"phone":70,"phoneExt":20,"email":71},"Ilenia Mappa, MD PhD","39 06 49971","giuseppe.rizzo@uniroma2.it",[73],{"facility":74,"status":20,"city":75,"state":20,"zip":76,"country":77,"countryCode":78,"cosmosGeoPoint":79,"geoPoint":84,"contacts":20},"Policlinico Umberto I, Sapienza University of Rome","Rome","00161","Italy","IT",{"type":80,"coordinates":81},"Point",[82,83],12.51133,41.89193,{"lat":83,"lon":82},{"type":86,"investigatorFullName":87,"investigatorTitle":88,"investigatorAffiliation":5,"oldNameTitle":20,"oldOrganization":20},"SPONSOR_INVESTIGATOR","Giuseppe Rizzo","Prof","100666817","computerised-ctg-changes-during-mechanical-cervical-ripening-with-balloon-or-dilapan-s-100666817",false,"NCT07961382","Computerised CTG Changes During Mechanical Cervical Ripening With Balloon or Dilapan-S","Computerised Cardiotocographic Changes During Mechanical Cervical Ripening With a Double-Balloon Catheter or a Synthetic Osmotic Dilator (MECH-cCTG): a Prospective Observational Cohort Study","MECH-cCTG","Inclusion Criteria:\n\n* Age 18 years or older\n* Singleton pregnancy in cephalic presentation\n* Gestational age 34+0 weeks or more, dated by first-trimester crown-rump length\n* Clinical indication for induction of labour\n* Unfavourable cervix (Bishop score below 6) with planned ripening by double-balloon catheter or Dilapan-S\n* Intact membranes\n* Written informed consent\n\nExclusion Criteria:\n\n* Labour, regular painful contractions or ruptured membranes at enrolment\n* Contraindication to vaginal birth or to mechanical ripening (placenta praevia or low-lying placenta, active genital infection, active vaginal bleeding)\n* Major fetal structural or chromosomal anomaly, or fetal arrhythmia\n* Maternal drugs that alter fetal heart rate variation in the previous 7 days (corticosteroids, magnesium sulphate, beta-blockers, opioids, benzodiazepines) or methyldopa started within 48 hours\n* Any pharmacological ripening agent before or during the study period\n* Maternal fever 38 degrees C or higher, or maternal heart rate above 100 bpm at baseline\n* Baseline computerised CTG not meeting Dawes-Redman criteria within 60 minutes","FEMALE","18 Years",{"count":100,"type":101},184,"ESTIMATED","OBSERVATIONAL","Mechanical cervical ripening (balloon catheters and synthetic osmotic dilators) is considered safe for the fetus because it rarely causes uterine tachysystole. However, its effect on fetal heart rate control has never been measured objectively. This study uses computerised cardiotocography (cCTG, Dawes-Redman analysis) to measure fetal heart rate parameters before and after insertion of a double-balloon catheter (CRB) or Dilapan-S in women undergoing induction of labour. Each woman has three 60-minute cCTG recordings: before insertion, immediately after insertion, and at device removal after 12 hours. The main question is whether short-term variation (STV) changes after insertion, and whether changes differ between the two devices.",[105,106],"Induction of Labor","Cervical Ripening",[108,109,110,47,111,112],"computerised cardiotocography","short-term variation","Dawes-Redman","cervical ripening balloon","mechanical induction of labour","NOT_YET_RECRUITING","2026-11-19",{"date":116,"type":117},"2026-11-27","ACTUAL",{"date":119,"type":101},"2027-01-15",{"date":121,"type":101},"2028-01-16",{"name":87,"class":6},1]