[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100666938":3},{"organization":4,"outcomesModule":7,"designInfo":69,"detailedDescription":71,"studyPopulation":72,"armGroups":73,"interventions":89,"overallOfficials":102,"centralContacts":107,"locations":113,"responsibleParty":126,"collaborators":68,"id":129,"slug":130,"hasResults":131,"nctId":132,"briefTitle":133,"officialTitle":134,"acronym":68,"eligibilityCriteria":135,"healthyVolunteers":131,"sex":136,"minAge":137,"maxAge":68,"enrollmentInfo":138,"targetDuration":68,"studyType":141,"phases":68,"briefSummary":142,"conditions":143,"keywords":146,"overallStatus":115,"whyStopped":68,"lastUpdateSubmitDate":150,"lastUpdatePostDateStruct":151,"startDateStruct":154,"completionDateStruct":156,"leadSponsor":158,"locationsCount":159},{"fullName":5,"class":6},"Shandong University","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":17,"otherOutcomes":68},[9,13],{"measure":10,"description":11,"timeFrame":12},"mAP@0.5:0.95","For the lesion-detection task, average precision is calculated at 10 intersection-over-union thresholds ranging from 0.50 to 0.95 in increments of 0.05, and the mean of these 10 values is reported. Double-blind annotations from senior endoscopists are used as the reference standard. This indicator evaluates the model's overall lesion-detection and localization performance across a range of overlap criteria. A higher mAP@0.5:0.95 indicates more accurate and robust lesion detection.","At the end of cross-sectional validation, up to 12 months",{"measure":14,"description":15,"timeFrame":16},"Clinical Acceptability of Automatically Generated Reports","The outcome is defined as the proportion of AI-generated reports receiving a Likert score of ≥4 on a five-point scale, where 1 indicates \"completely unusable\" and 5 indicates \"ready for direct issuance.\" Three blinded senior endoscopists independently rate each report, and the modal rating is used as the final score. This indicator measures the proportion of AI-generated reports considered clinically usable with little or no revision. A higher acceptability rate indicates better clinical applicability of the report-generation system.","At report review, through prospective validation, up to 3 months",[18,22,25,28,32,35,39,42,45,49,52,55,59,62,65],{"measure":19,"description":20,"timeFrame":21},"Number of Physician Modifications","The number of additions, deletions, and revisions made by the physician is extracted from the system's backend logs. This indicator measures the extent of physician intervention required to finalize an AI-generated report. Fewer modifications indicate that the generated report is more accurate, complete, and clinically usable.","From AI report generation to final issuance, up to 3 months",{"measure":23,"description":24,"timeFrame":12},"Cohen's Kappa for Video Quality Assessment","The model's video quality assessments are compared with experts' subjective ratings, and Cohen's kappa is calculated to assess agreement in image clarity, exposure, field-of-view completeness, and other quality dimensions. This indicator measures chance-adjusted agreement between the model and expert endoscopists. A higher kappa value indicates stronger agreement.",{"measure":26,"description":27,"timeFrame":12},"Sensitivity","Model outputs are classified as positive or negative using a prespecified clinically relevant threshold. Sensitivity is calculated as the number of true-positive lesions correctly identified by the model divided by the total number of positive lesions according to the reference standard. This indicator measures the model's ability to detect patients or lesions with the target condition. A higher sensitivity indicates a lower false-negative rate.",{"measure":29,"description":30,"timeFrame":31},"NASA-TLX Total Workload Score","The NASA-TLX questionnaire is used to evaluate six dimensions: mental demand, physical demand, temporal demand, performance, effort, and frustration. The dimension scores are combined into a weighted total score. This indicator measures physicians' perceived workload when preparing endoscopy reports. A lower score under the AI-assisted condition indicates that the system reduces physician workload.","Immediately after each reporting task, up to 3 months",{"measure":33,"description":34,"timeFrame":12},"Weighted F1-Score","Precision and recall are calculated for each lesion category and combined to obtain the category-specific F1-score. The F1-scores are then weighted according to the number of samples in each category, using the double-blind review results from senior endoscopists as the reference standard. This indicator summarizes classification precision and recall while accounting for differences in category size. A higher weighted F1-score indicates better overall classification or grading performance.",{"measure":36,"description":37,"timeFrame":38},"Terminology Error Rate","NLP-based rules are first applied to detect non-standard terminology, incorrect wording, and inappropriate expressions, followed by manual sampling and verification. The proportion of reports or terms containing terminology errors is then calculated. This indicator measures the frequency of inaccurate or non-standard clinical terminology in AI-generated reports. A lower error rate indicates greater linguistic accuracy and reporting safety.","At final report issuance, through prospective validation, up to 3 months",{"measure":40,"description":41,"timeFrame":12},"Specificity","Model outputs are classified as positive or negative using a prespecified clinically relevant threshold. Specificity is calculated as the number of true-negative cases correctly identified by the model divided by the total number of negative cases according to the reference standard. This indicator measures the model's ability to correctly identify patients or lesions without the target condition. A higher specificity indicates a lower false-positive rate.",{"measure":43,"description":44,"timeFrame":38},"BERTScore-F1","BERT-based contextual embeddings are used to compare the AI-generated report with the reference report. Semantic precision and semantic recall are calculated and combined into an F1-score. This indicator measures semantic similarity between the two reports, including similarities not captured by exact word matching. A higher BERTScore-F1 indicates greater semantic consistency.",{"measure":46,"description":47,"timeFrame":48},"Report-Writing Time","A system timer automatically records the time, in seconds, from the end of the gastroscopy examination to final report issuance. Report-writing time is compared between the AI-assisted and conventional conditions. This indicator evaluates whether AI assistance improves report-generation efficiency. A shorter report-writing time under the AI-assisted condition indicates greater efficiency.","From procedure completion to final report issuance, up to 3 months",{"measure":50,"description":51,"timeFrame":12},"Lesion Classification or Grading Accuracy","The lesion category or grade predicted by the model is compared case by case with the results of double-blind review by senior endoscopists. Accuracy is calculated as the number of correctly classified cases or lesions divided by the total number evaluated. This indicator measures the proportion of lesions or cases correctly classified or graded by the model. A higher accuracy indicates better agreement with the expert reference standard.",{"measure":53,"description":54,"timeFrame":38},"ROUGE-L","Text similarity is calculated using the longest common subsequence between the AI-generated report and the reference report. This indicator evaluates the consistency of report content, information sequence, and textual structure. A higher ROUGE-L score indicates greater textual consistency.",{"measure":56,"description":57,"timeFrame":58},"Incidence of Diagnostic Deviation Events","An event is recorded when AI assistance causes the final issued report to differ from the reference standard and the discrepancy affects clinical decision-making. The incidence is calculated as the number of such events divided by the total number of evaluated cases. This indicator measures clinically consequential diagnostic errors attributable to AI assistance. A lower incidence indicates greater clinical safety.","Through prospective validation, up to 3 months",{"measure":60,"description":61,"timeFrame":16},"Critical Negative Finding Omission Rate","Clinically important findings or lesions requiring intervention that are omitted from the AI-generated report are identified. The omission rate is calculated as the number of omitted findings divided by the total number of findings that should have been reported. This indicator measures the risk that AI-generated reports fail to document clinically important findings. A lower omission rate indicates greater report completeness and safety.",{"measure":63,"description":64,"timeFrame":12},"Area Under the Receiver Operating Characteristic Curve","A receiver operating characteristic curve is constructed using lesion-level model confidence scores as the predictor and expert-reviewed results as the reference standard. The area under the curve is then calculated. AUC measures the model's overall ability to distinguish between positive and negative lesions across all possible classification thresholds. A higher AUC indicates better discriminative performance.",{"measure":66,"description":67,"timeFrame":38},"BLEU-4","Using the physician's final issued report or an expert reference report as the reference, the overlap of one- to four-word sequences between the AI-generated and reference reports is calculated. This indicator measures lexical similarity between the reports, with particular emphasis on the precision of matching word sequences. A higher BLEU-4 score indicates greater textual similarity.",null,{"allocation":68,"interventionModel":68,"interventionModelDescription":68,"primaryPurpose":68,"observationalModel":70,"timePerspective":6,"maskingInfo":68},"COHORT","This study employs three time perspectives: retrospective, cross-sectional, and prospective.\n\nThe total number of participants is expected to be 371000 (300000 for constructing the retrospective training set, 70000 for evaluating the cross-sectional validation set, and 1000 for prospective clinical validation)","Individuals who are at least 18 years of age, are undergoing a routine gastroscopy, and have provided informed consent to participate in this study",[74,79,84],{"label":75,"type":68,"description":76,"interventionNames":77},"Retrospective","Retrospective training set construction",[78],"Other: Retrospective Model Development Cohort",{"label":80,"type":68,"description":81,"interventionNames":82},"cross-sectional","cross-sectional validation set evaluation",[83],"Other: Cross-Sectional Validation Cohort",{"label":85,"type":68,"description":86,"interventionNames":87},"prospective","prospective clinical efficacy validation",[88],"Other: Prospective Clinical Evaluation Cohort",[90,94,98],{"type":6,"name":91,"description":92,"armGroupLabels":93,"otherNames":68},"Retrospective Model Development Cohort","This cohort includes approximately 300,000 patients who underwent gastroscopy. Retrospectively collected gastroscopy images, videos, and corresponding endoscopy reports will be used for the development, training, and internal validation of multimodal, multitask artificial intelligence models. No study-specific interventions will be administered to patients.",[75],{"type":6,"name":95,"description":96,"armGroupLabels":97,"otherNames":68},"Cross-Sectional Validation Cohort","This cohort includes approximately 70,000 patients who underwent gastroscopy. Gastroscopy images, videos, and corresponding reports will be used to independently evaluate the diagnostic performance, video quality assessment, and report generation capabilities of the developed AI models. Model outputs will be compared with expert-established reference standards. No study-specific interventions will be administered to patients.",[80],{"type":6,"name":99,"description":100,"armGroupLabels":101,"otherNames":68},"Prospective Clinical Evaluation Cohort","This cohort will include approximately 1,000 patients undergoing gastroscopy. The developed AI system will be evaluated in real-world clinical workflows. The study will assess report generation efficiency, clinical acceptability, physician workload, and safety by comparing AI-assisted reporting with conventional physician reporting. Final endoscopy reports will be reviewed and signed by physicians.",[85],[103],{"name":104,"affiliation":105,"role":106},"Xiuli Zuo","Qilu Hospital of Shandong University","STUDY_CHAIR",[108],{"name":109,"role":110,"phone":111,"phoneExt":68,"email":112},"Mingjun Ma","CONTACT","+86 15153118009","202662001088@email.sdu.edu.cn",[114],{"facility":105,"status":115,"city":116,"state":117,"zip":68,"country":118,"countryCode":119,"cosmosGeoPoint":120,"geoPoint":125,"contacts":68},"RECRUITING","Jinan","Shandong","China","CN",{"type":121,"coordinates":122},"Point",[123,124],116.99722,36.66833,{"lat":124,"lon":123},{"type":127,"investigatorFullName":104,"investigatorTitle":128,"investigatorAffiliation":5,"oldNameTitle":68,"oldOrganization":68},"PRINCIPAL_INVESTIGATOR","Department Director","100666938","development-and-clinical-evaluation-of-multimodal-ai-for-gastroscopy-and-automated-report-generation-100666938",false,"NCT07961759","Development and Clinical Evaluation of Multimodal AI for Gastroscopy and Automated Report Generation","A Study on the Construction of Multi-Task, Multi-Modal Models for Gastroscopy Diagnosis and Treatment Scenarios and the Automatic Generation of Endoscopy Reports","Inclusion Criteria:\n\n\\- Patients undergoing gastroscopy\n\nExclusion Criteria:\n\n* Patients undergoing specialized endoscopic procedures, such as endoscopic ultrasonography or endoscopic retrograde cholangiopancreatography (ERCP)","ALL","18 Years",{"count":139,"type":140},371000,"ESTIMATED","OBSERVATIONAL","This mixed-methods study will include retrospective model development, cross-sectional validation, and prospective clinical validation. The study will generally follow relevant guidelines for AI-based clinical research.\n\n1. Retrospective Model Development\n\n   Approximately 300,000 gastroscopy examinations from our center will be retrospectively included. Available endoscopic data and related clinical information will be collected for model development and internal validation.\n\n   Several publicly available gastrointestinal endoscopy datasets will also be included to increase data diversity. These datasets will provide supplementary data for model development and evaluation.\n\n   The model will broadly support common gastroscopy-related tasks, such as lesion assessment, examination quality evaluation, and report generation. General data cleaning, quality control, and expert review will be conducted when necessary.\n2. Cross-sectional Validation\n\n   Approximately 70,000 gastroscopy examinations from a different time period will be consecutively included for independent validation.\n\n   The model results will be compared with reference results established according to generally accepted clinical practice. Diagnostic standards will broadly follow relevant clinical guidelines and expert judgment.\n\n   The purpose of this phase is to assess the model's overall diagnostic performance, report quality, generalizability, and stability using commonly accepted evaluation methods.\n3. Prospective Clinical Validation\n\nA prospective clinical validation study involving approximately 1,000 patients will be conducted at our center.\n\nThe model will be integrated into routine clinical practice to provide general assistance to physicians. Its outputs will be used for reference and will not replace physicians' final clinical decisions or signed reports.\n\nThe study will generally compare clinical workflows with and without AI assistance. It will assess the model's potential effects on work efficiency, workload, clinical usability, and safety under real-world conditions.",[144,145],"AI (Artificial Intelligence)","Endoscopy of Stomach (Procedure)",[147,148,149],"upper gastrointestinal diseases","AI","endoscopy","2026-11-19",{"date":152,"type":153},"2026-11-27","ACTUAL",{"date":155,"type":140},"2026-11-12",{"date":157,"type":140},"2028-08-01",{"name":5,"class":6},1]