[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100661940":3},{"organization":4,"outcomesModule":7,"designInfo":41,"detailedDescription":43,"studyPopulation":44,"armGroups":45,"interventions":54,"overallOfficials":64,"centralContacts":68,"locations":74,"responsibleParty":87,"collaborators":89,"id":94,"slug":95,"hasResults":96,"nctId":97,"briefTitle":98,"officialTitle":99,"acronym":40,"eligibilityCriteria":100,"healthyVolunteers":96,"sex":101,"minAge":102,"maxAge":103,"enrollmentInfo":104,"targetDuration":40,"studyType":107,"phases":40,"briefSummary":108,"conditions":109,"keywords":114,"overallStatus":121,"whyStopped":40,"lastUpdateSubmitDate":122,"lastUpdatePostDateStruct":123,"startDateStruct":126,"completionDateStruct":128,"leadSponsor":130,"locationsCount":131},{"fullName":5,"class":6},"Ruijin Hospital","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":27,"otherOutcomes":40},[9,13,17,21,24],{"measure":10,"description":11,"timeFrame":12},"Diagnostic Performance of ARDS Subphenotype Classification","Area Under the Receiver Operating Characteristic curve (AUC-ROC) of the AutoEIT model for classifying ARDS subphenotypes into hyperinflammatory versus hypoinflammatory phenotypes, using latent class analysis (LCA) based on clinical and biomarker data as the reference ground truth. AUC-ROC will be calculated with 95% confidence intervals using DeLong's method. A predefined threshold of AUC-ROC ≥ 0.80 will be considered clinically acceptable.Unit of Measure: AUC-ROC (dimensionless, 0 to 1)","At baseline, within 24 hours of ARDS diagnosis or Intensive Care Unit (ICU) admission.",{"measure":14,"description":15,"timeFrame":16},"Accuracy of Optimal PEEP Recommendation","Root Mean Square Error (RMSE) between the AutoEIT-recommended positive end-expiratory pressure (PEEP) and the clinically optimal PEEP derived from the intersection point of lung collapse and overdistension curves obtained during a standardized decremental PEEP trial. RMSE will be calculated in cmH2O; lower values indicate better agreement. A clinically acceptable RMSE threshold is predefined as ≤ 2.0 cmH2O.Unit of Measure: cmH2O","At the time of the first standardized decremental PEEP trial, within 72 hours of enrollment.",{"measure":18,"description":19,"timeFrame":20},"Detection Accuracy of Patient-Ventilator Asynchrony","Area Under the Receiver Operating Characteristic curve (AUC-ROC) of the AutoEIT model for detecting occult patient-ventilator asynchrony events, including pendelluft, breath-stacking, and ineffective triggering, validated independently against blinded expert review of synchronized video, EIT images, and ventilator waveforms by two intensivists. AUC-ROC will be calculated with 95% confidence intervals. A predefined threshold of AUC-ROC ≥ 0.85 will be considered clinically acceptable.Unit of Measure: AUC-ROC (dimensionless, 0 to 1)","Throughout the EIT monitoring period, within 72 hours of enrollment.",{"measure":22,"description":23,"timeFrame":20},"Accuracy of V\u002FQ Ratio Prediction","Pearson Correlation Coefficient (PCC) between the AutoEIT-predicted ventilation\u002Fperfusion (V\u002FQ) ratio and the physiological ground truth measured by the reference multiple inert gas elimination technique (MIGET) or a surrogate method. PCC will be calculated with 95% confidence intervals using Fisher's z-transformation. A predefined threshold of PCC ≥ 0.70 will be considered clinically acceptable.Unit of Measure: PCC (dimensionless, range -1 to 1)",{"measure":25,"description":26,"timeFrame":20},"Accuracy of Non-invasive PaO2\u002FFiO2 Ratio Prediction","Root Mean Square Error (RMSE) between the AutoEIT-predicted non-invasive PaO2\u002FFiO2 ratio and the simultaneously measured arterial blood gas (ABG) PaO2\u002FFiO2 ratio. RMSE will be calculated in mmHg; lower values indicate better agreement. A clinically acceptable RMSE threshold is predefined as ≤ 20 mmHg.Unit of Measure: mmHg",[28,32,36],{"measure":29,"description":30,"timeFrame":31},"Prognostic Association with 28-Day Ventilator-Free Days (VFDs)","Correlation between AutoEIT-derived dynamic spatiotemporal features extracted from the foundation model embeddings and the number of ventilator-free days (VFDs) at day 28, defined as the number of days from successful weaning to day 28 during which the patient is alive and free from invasive mechanical ventilation. The association will be assessed using multivariable linear regression models adjusted for Acute Physiology and Chronic Health Evaluation II (APACHE II) score, age, and baseline PaO2\u002FFiO2 ratio. Partial correlation coefficients (r) and 95% confidence intervals will be reported.Unit of Measure: Days (continuous)","From enrollment to the end of treatment at day 28.",{"measure":33,"description":34,"timeFrame":35},"Intensive Care Unit (ICU) All-Cause Mortality Prediction","Predictive value of AutoEIT-derived subphenotypes, hyperinflammatory versus hypoinflammatory, for ICU all-cause mortality, assessed using Cox proportional hazards regression models. Hazard ratios (HR) with 95% confidence intervals will be reported for the association between subphenotype and mortality, adjusted for age, APACHE II score, and vasopressor use.Hazard ratio (HR, dimensionless)","From ICU admission to ICU discharge or death, assessed up to day 28.",{"measure":37,"description":38,"timeFrame":39},"28-Day All-Cause Mortality Prediction","Predictive value of AutoEIT-derived subphenotypes, hyperinflammatory versus hypoinflammatory, for 28-day all-cause mortality, assessed using Cox proportional hazards regression models. Hazard ratios (HR) with 95% confidence intervals will be reported for the association between subphenotype and mortality, adjusted for age, APACHE II score, and vasopressor use. Cumulative incidence of mortality will be visualized using Kaplan-Meier curves, and the log-rank test will be used to compare survival distributions between subphenotypes.Hazard ratio (HR, dimensionless)","From enrollment to day 28.",null,{"allocation":40,"interventionModel":40,"interventionModelDescription":40,"primaryPurpose":40,"observationalModel":42,"timePerspective":6,"maskingInfo":40},"COHORT","This is a multicenter ambispective cohort study designed to develop and prospectively validate an all-in-one Artificial Intelligence Foundation Model (AutoEIT) for the precision management of Acute Respiratory Distress Syndrome (ARDS). The study comprises two distinct phases:\n\nPhase 1 - Retrospective Training and Internal Validation (2020-2025): A total of 1000 adult ARDS patients who received invasive mechanical ventilation and continuous Electrical Impedance Tomography (EIT) monitoring across three participating tertiary hospitals will be enrolled. High-frequency ventilator waveforms (≥ 200 Hz), synchronized EIT image sequences (≥ 20 frames\u002Fsecond), and concurrent arterial blood gas (ABG) measurements will be extracted from electronic health records. This dataset will be used to train the shared spatiotemporal encoder and five task-specific prediction heads of the AutoEIT foundation model using a deep multi-task learning framework. Internal validation will be performed via 5-fold cross-validation, with a 70\u002F30 training-to-validation split.\n\nPhase 2 - Prospective Temporal and External Validation (January 2026 - December 2026): A total of 200 adult ARDS patients will be prospectively enrolled at the same centers. For this critical validation phase, millisecond-level synchronization between the EIT system, mechanical ventilator, and clinical events (e.g., ABG sampling timestamps) will be enforced prior to data recording. The AutoEIT model will run in the background in a fully blinded manner (i.e., clinicians will not receive any model-generated outputs), and its five-task predictions will be compared against the clinical ground truths at the end of the monitoring period.\n\nThe Five Core Clinical Tasks of the AutoEIT Model:\n\nARDS Subphenotype Classification: The model will classify patients into hyperinflammatory versus hypoinflammatory phenotypes using latent class analysis (LCA) as the reference standard. Performance will be evaluated by Area Under the Receiver Operating Characteristic curve (AUC-ROC), with a predefined clinically acceptable threshold of AUC-ROC ≥ 0.80.\n\nIndividualized Positive End-Expiratory Pressure (PEEP) Recommendation: The model will recommend an optimal PEEP level derived from the intersection of lung collapse and overdistension curves during a standardized decremental PEEP trial. Accuracy will be quantified by Root Mean Square Error (RMSE) in cmH₂O, with a predefined acceptable threshold of ≤ 2.0 cmH₂O.\n\nOccult Patient-Ventilator Asynchrony Detection: The model will detect asynchrony events (including pendelluft, breath-stacking, and ineffective triggering) in real-time, validated against blinded expert review of synchronized video, EIT, and waveform data. Performance will be assessed by AUC-ROC, with a predefined threshold of AUC-ROC ≥ 0.85.\n\nVentilation\u002FPerfusion (V\u002FQ) Ratio Prediction: The model will continuously estimate the regional V\u002FQ ratio, with reference values obtained from the multiple inert gas elimination technique (MIGET) or a validated surrogate. Performance will be measured by Pearson Correlation Coefficient (PCC), with a predefined acceptable threshold of PCC ≥ 0.70.\n\nNon-invasive PaO₂\u002FFiO₂ Ratio Estimation: The model will predict the PaO₂\u002FFiO₂ ratio without invasive ABG sampling, compared against simultaneous ABG measurements. Accuracy will be evaluated by RMSE (dimensionless), with a predefined acceptable threshold of ≤ 20 units. Bland-Altman limits of agreement and mean bias will be reported as descriptive secondary analyses.\n\nStatistical Analysis Plan:\n\nFor the retrospective phase, model training will be conducted using PyTorch with an Adam optimizer and a learning rate of 1e-4. Early stopping with a patience of 10 epochs will be applied to prevent overfitting. For the prospective validation phase, all five primary outcomes will be assessed using a per-patient analysis. AUC-ROC will be calculated with 95% confidence intervals using DeLong's method; RMSE will be reported with bootstrap 95% confidence intervals (1000 resamples); PCC will be computed with 95% confidence intervals using Fisher's z-transformation. Subgroup analyses will be performed according to ARDS severity (moderate vs. severe), age group (≥ 60 vs. \\\u003C 60 years), and primary etiology (pulmonary vs. extrapulmonary). All statistical tests will be two-sided with a significance level of α = 0.05. Missing data will be handled via multiple imputation by chained equations (MICE) if the proportion of missingness is \\\u003C 20%; otherwise, complete-case analysis will be performed.\n\nSample Size Justification: The retrospective cohort of 1000 patients is derived from the available data from 2020 to 2025 at the three participating centers and is considered adequate for deep learning model training based on prior similar EIT-AI studies. The prospective cohort of 200 patients was calculated to provide \\> 80% power to detect a moderate effect size (Cohen's d = 0.5) for the primary outcomes, assuming a two-sided α of 0.05 and a 15% dropout rate. This sample size also ensures sufficient event counts (≥ 10 events per predictor variable) for the Cox proportional hazards models used in secondary mortality analyses.\n\nStudy Governance: The study is sponsored by Ruijin Hospital, with collaborating centers including Peking Union Medical College Hospital and Fujian Provincial Hospital. An independent Data Monitoring Committee (DMC) will oversee patient safety and interim analyses. The study protocol has been approved by the Ruijin Hospital Ethics Committee (Approval No. 202647), and all patients or their legal surrogates will provide written informed consent prior to enrollment in the prospective phase.","Adult ARDS patients admitted to participating ICUs who received invasive mechanical ventilation and EIT monitoring",[46,50],{"label":47,"type":40,"description":40,"interventionNames":48},"Cohort 1: Retrospective Training and Internal Validation Cohort",[49],"Diagnostic Test: AutoEIT Model Training",{"label":51,"type":40,"description":40,"interventionNames":52},"Cohort 2: Prospective Temporal\u002FExternal Validation Cohort",[53],"Diagnostic Test: AutoEIT Blinded Validation",[55,60],{"type":56,"name":57,"description":58,"armGroupLabels":59,"otherNames":40},"DIAGNOSTIC_TEST","AutoEIT Model Training","Adult ARDS patients admitted to participating ICUs between January 2020 and December 2025 who received invasive mechanical ventilation and EIT monitoring. Data from this cohort will be used exclusively to train the shared spatiotemporal encoder and the five task specific prediction heads of the AutoEIT foundation model.",[47],{"type":56,"name":61,"description":62,"armGroupLabels":63,"otherNames":40},"AutoEIT Blinded Validation","Adult ARDS patients prospectively enrolled between January 2026 and December 2026. For this cohort, strict millisecond-level synchronization between the EIT system, mechanical ventilator, and clinical events (e.g., ABG sampling) will be enforced. The AutoEIT model will run in the background (blinded to treating clinicians) to generate the 5-task predictions, which will later be compared against actual clinical ground truths.",[51],[65],{"name":66,"affiliation":5,"role":67},"Rui Zhang","PRINCIPAL_INVESTIGATOR",[69],{"name":70,"role":71,"phone":72,"phoneExt":40,"email":73},"Rui Zhang, MD","CONTACT","0086-021-67340045","ccmzhangrui@foxmail.com",[75],{"facility":76,"status":40,"city":77,"state":78,"zip":40,"country":79,"countryCode":80,"cosmosGeoPoint":81,"geoPoint":86,"contacts":40},"Department of Critical Care Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine","Shanghai","Shanghai Municipality","China","CN",{"type":82,"coordinates":83},"Point",[84,85],121.45806,31.22222,{"lat":85,"lon":84},{"type":88,"investigatorFullName":40,"investigatorTitle":40,"investigatorAffiliation":40,"oldNameTitle":40,"oldOrganization":40},"SPONSOR",[90,92],{"name":91,"class":6},"Peking Union Medical College Hospital",{"name":93,"class":6},"Fujian Provincial Hospital","100661940","development-and-prospective-validation-of-the-autoeit-foundation-model-for-ards-100661940",false,"NCT07898319","Development and Prospective Validation of the AutoEIT Foundation Model for ARDS","A Multimodal Artificial Intelligence Foundation Model for Precision Management of Acute Respiratory Distress Syndrome (ARDS) (AutoEIT): Development and Prospective Validation in a Multicenter Cohort","Inclusion Criteria:\n\n* Age ≥ 18 years;\n* Admitted to the Intensive Care Unit (ICU);\n* Receiving invasive mechanical ventilation for at least 24 hours;\n* Diagnosed with moderate-to-severe ARDS according to the Berlin Definition as PaO2\u002FFiO2 ≤ 200 mmHg with PEEP ≥ 5 cmH2O.;\n* Underwent continuous EIT monitoring during the ICU stay;\n* Availability of synchronized high-frequency ventilator waveforms and concurrent arterial blood gas (ABG) results;\n* (Specific for Prospective Cohort): EIT, ventilator, and clinical event times must be prospectively synchronized via precise time-stamping before data recording.\n\nExclusion Criteria:\n\n* Extremely poor EIT signal quality (e.g., severe artifacts, electrode detachment lasting \\> 50% of the monitoring time);\n* Patients receiving Extracorporeal Membrane Oxygenation (ECMO) therapy prior to or during the EIT monitoring period;\n* Severe thoracic deformity, un-drained severe pneumothorax, or extensive chest burns precluding proper EIT belt placement;\n* Decision to withhold or withdraw life-sustaining treatment do-not-resuscitate\u002Fdo-not-intubate (DNR\u002FDNI) at the time of enrollment.","ALL","18 Years","90 Years",{"count":105,"type":106},1200,"ESTIMATED","OBSERVATIONAL","Acute Respiratory Distress Syndrome (ARDS) is a highly heterogeneous condition, making precision mechanical ventilation challenging. Electrical Impedance Tomography (EIT) provides real-time monitoring of regional lung ventilation, but interpreting its complex spatiotemporal data relies on subjective clinical experience. This multicenter ambispective cohort study aims to develop and validate an all-in-one Artificial Intelligence Foundation Model (AutoEIT). The study consists of two phases: (1) A Retrospective Phase (data from 2020 to 2025, N=1000) to train the AutoEIT model using continuous EIT images and synchronous high-frequency ventilator waveforms; and (2) A Prospective Temporal Phase (January 2026 to December 2026, N=200) to rigorously test the model's performance in a real-world clinical setting. The AutoEIT model is a deep multi-task learning framework designed to simultaneously perform five core clinical tasks: (1) classify ARDS subphenotypes, (2) recommend individualized positive end-expiratory pressure (PEEP), (3) detect occult patient-ventilator asynchrony, (4) predict ventilation\u002Fperfusion (V\u002FQ) ratio, and (5) continuously estimate the non-invasive PaO₂\u002FFiO₂ ratio. Ultimately, this system aims to reduce ventilator-induced lung injury (VILI) and improve precision respiratory care.",[110,111,112,113],"ARDS (Acute Respiratory Distress Syndrome)","Respiratory Failure","Mechanical Ventilation","Ventilator-induced Lung Injury (VILI)",[115,116,117,118,119,120],"Electrical Impedance Tomography (EIT)","Artificial Intelligence","Foundation Model","Multi-task Learning","Precision Medicine","Patient-Ventilator Asynchrony","NOT_YET_RECRUITING","2026-10-20",{"date":124,"type":125},"2026-10-27","ACTUAL",{"date":127,"type":106},"2026-11-01",{"date":129,"type":106},"2027-05-31",{"name":5,"class":6},1]