[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100662213":3},{"organization":4,"outcomesModule":7,"designInfo":14,"detailedDescription":21,"studyPopulation":13,"armGroups":22,"interventions":29,"overallOfficials":13,"centralContacts":38,"locations":48,"responsibleParty":62,"collaborators":13,"id":66,"slug":67,"hasResults":68,"nctId":69,"briefTitle":70,"officialTitle":70,"acronym":71,"eligibilityCriteria":72,"healthyVolunteers":68,"sex":73,"minAge":74,"maxAge":13,"enrollmentInfo":75,"targetDuration":13,"studyType":78,"phases":79,"briefSummary":80,"conditions":81,"keywords":90,"overallStatus":99,"whyStopped":13,"lastUpdateSubmitDate":100,"lastUpdatePostDateStruct":101,"startDateStruct":104,"completionDateStruct":106,"leadSponsor":108,"locationsCount":109},{"fullName":5,"class":6},"The University of Hong Kong","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":13},[9],{"measure":10,"description":11,"timeFrame":12},"sensitivity of POC-ANC compared with the laboratory reference method","The target accuracy index is the lower 95%CI of sensitivity, although we evaluate other important factors of diagnostic accuracy (see data analysis below).\n\nThe primary analysis is on sensitivity of 97 - 99.9% looking to safely rule out NF.","All samples will be analysed in duplicates on the HemoCue WBC DIFF system and in single replicate on the Sysmex XE-5000 within 8 hours after collection.",null,{"allocation":15,"interventionModel":16,"interventionModelDescription":17,"primaryPurpose":18,"observationalModel":13,"timePerspective":13,"maskingInfo":19},"NA","SINGLE_GROUP","Study Design\n\nS1. Prospective diagnostic accuracy of POC-ANC;\n\nS1. Diagnostic Accuracy\n\nThe diagnostic study will be performed 24 hours a day. Informed consent will be sought from every patient for a finger prick (capillary blood) and venous blood sample.\n\nWe use methods as previously reported by Russcher \\[16\\]. Briefly, paired capillary (finger prick) and venous EDTA blood samples will be obtained from 317 patients meeting the inclusion criteria. Reference counts (Gold standard) will be obtained by a standard¬ised Sysmex XE-5000 automated cell counter (Sysmex Corporation, Kobe, Japan). All samples will be analysed in duplicates on the HemoCue WBC DIFF system and in single replicate on the Sysmex XE-5000 within 8 hours after collection. The timespan between analyses on both systems should be less than 2 hours for each sample.","DIAGNOSTIC",{"masking":20,"maskingDescription":13,"whoMasked":13},"NONE","Questions\n\nIn ED and hospitalised adult cancer patients with sNF, is a POC-ANC sufficiently accurate as a diagnostic test compared with a laboratory gold standard?\n\nPrimary hypotheses\n\nStudy 1 (S1). In a range of adult patients with sNF and controls, there is no significant difference between the POC-ANC and laboratory analyser.\n\nDefinitions\n\nSuspected neutropenic fever (sNF) refers to fever after myelosuppressive cancer treatment in a patient in whom neutropenia is suspected, before laboratory confirmation.\n\nThe definition of NF varies across different international guidelines. In this proposal, NF is defined as an ANC \\\u003C1.0 × 10⁹\u002FL and fever with a single oral temperature of ≥38.3°C (101°F) or a temperature of ≥38.0°C (100.4°F) sustained over a one-hour period after myelosuppressive cancer treatment in the ED or within 24 hours prior to ED registration. However, some guidelines and oncologists set the definition of NF at \\\u003C0.5 × 10⁹\u002FL.\n\nSevere neutropenia is defined as an ANC \\\u003C0.5 × 10⁹\u002FL. This NF definition leaves a safety margin with an anticipation that some patients with an initial ANC of 0.5-1.0 × 10⁹\u002FL may progress to severe neutropenia over the next 48 hours.\n\nThus, sNF patients will be further categorised into severe NF (ANC \\\u003C0.5 × 10⁹\u002FL), non-severe NF (ANC 0.5-1.0 × 10⁹\u002FL) and non-NF (ANC ≥1.0 × 10⁹\u002FL) for comparison.\n\nS1. Diagnostic Accuracy\n\nThe diagnostic study will be performed 24 hours a day. Informed consent will be sought from every patient for a finger prick (capillary blood) and venous blood sample.\n\nWe use methods as previously reported by Russcher \\[16\\]. Briefly, paired capillary (finger prick) and venous EDTA blood samples will be obtained from 317 patients meeting the inclusion criteria. Reference counts (Gold standard) will be obtained by a standardised Sysmex XE-5000 automated cell counter (Sysmex Corporation, Kobe, Japan). All samples will be analysed in duplicates on the HemoCue WBC DIFF system and in single replicate on the Sysmex XE-5000 within 8 hours after collection. The timespan between analyses on both systems should be less than 2 hours for each sample.\n\nJustification for evaluating capillary blood\n\nIt is important to evaluate the accuracy of capillary blood as the POCANC device might find a use in other settings e.g. clinics, or home use.\n\nOutcomes\n\nProspective diagnostic accuracy study. The target accuracy index is the lower 95%CI of sensitivity, although we evaluate other important factors of diagnostic accuracy (see data analysis below).\n\nData processing\n\nThe primary analysis is on sensitivity of 97 - 99.9% looking to safely rule out NF.\n\nIn addition we will evaluate accuracy of the ANC aiming for the slope for linear regression between both test and reference methods no more than ± 5% (r≥0.95).\n\nWe will also calculate pooled standard deviations (SD) and coefficient variations (CV). We will report the SD\u002FCV and Bland-Altman Limits of acceptance (LoA) aiming for \\\u003C15%. All the data will be analysed using orthogonal regression analysis (Deming regression) and Pearson's correlation coefficient (r).\n\nWe will also report intra-and inter-class variation, inter-hospital laboratory variation (where available), specificity, AUC, NPV and PPV.\n\nMissing Data\n\nPatients with missing laboratory or POCT ANC data will be excluded from data analysis. For POCT ANC values below lower limit of detection leading to the absence of a numerical value, pairwise correlation analysis will not be performed. Other missing values will not be imputed.\n\nEthics approval\n\nThis study has been approved by the Institutional Review Board of The University of Hong Kong\u002FHospital Authority Hong Kong West Cluster (HKU\u002FHA HKW IRB; reference number: UW 25-660).",[23],{"label":24,"type":25,"description":26,"interventionNames":27},"Consented participants","EXPERIMENTAL","S1. Adult patients with suspected low ANC in the ED or admitted to medical wards.\n\n1. ≥18 years; AND\n2. Suspected low ANC; AND\n3. Stable",[28],"Diagnostic Test: Hemocue® WBC DIFF system",[30],{"type":31,"name":32,"description":33,"armGroupLabels":34,"otherNames":35},"DIAGNOSTIC_TEST","Hemocue® WBC DIFF system","Briefly, paired capillary (finger prick) and venous EDTA blood samples will be obtained from 317 patients meeting the inclusion criteria. Reference counts (Gold standard) will be obtained by a standardised Sysmex XE-5000 automated cell counter (Sysmex Corporation, Kobe, Japan). All samples will be analysed in duplicates on the HemoCue WBC DIFF system and in single replicate on the Sysmex XE-5000 within 8 hours after collection. The timespan between analyses on both systems should be less than 2 hours for each sample.",[24],[36,37],"POC-ANC","POCT-ANC",[39,44],{"name":40,"role":41,"phone":42,"phoneExt":13,"email":43},"Timothy Rainer","CONTACT","+852 39176846","thrainer@hku.hk",{"name":45,"role":41,"phone":46,"phoneExt":13,"email":47},"Manson Yeung","+852 39103191","htmanson@hku.hk",[49],{"facility":50,"status":13,"city":51,"state":13,"zip":13,"country":51,"countryCode":52,"cosmosGeoPoint":53,"geoPoint":58,"contacts":59},"Queen Mary Hospital","Hong Kong","HK",{"type":54,"coordinates":55},"Point",[56,57],114.17469,22.27832,{"lat":57,"lon":56},[60],{"name":40,"role":41,"phone":61,"phoneExt":13,"email":43},"39176846",{"type":63,"investigatorFullName":64,"investigatorTitle":65,"investigatorAffiliation":5,"oldNameTitle":13,"oldOrganization":13},"PRINCIPAL_INVESTIGATOR","Prof. Timothy Hudson RAINER","Professor","100662213","diagnostic-accuracy-clinical-utility-and-implementation-of-point-of-care-absolute-neutrophil-count-in-suspected-neutropenic-fever-ducatis---diagnostic-accuracy-s1-100662213",false,"NCT07901660","Diagnostic Accuracy, Clinical Utility and Implementation of Point-of-Care Absolute Neutrophil Count in Suspected Neutropenic Fever (DUCATIS) - Diagnostic Accuracy (S1)","DUCATIS - S1","Inclusion Criteria:\n\n1. ≥18 years; AND\n2. Suspected low ANC; AND\n3. Stable.\n\nExclusion Criteria:\n\n1. No consent obtained\n2. Blood sampling my hinder the management of the patient according to the doctor or nurse.","ALL","18 Years",{"count":76,"type":77},317,"ESTIMATED","INTERVENTIONAL",[15],"Study 1 (S1). In a range of adult patients with sNF and controls, there is no significant difference between the POC-ANC and laboratory analyser.\n\nThe diagnostic study will be performed 24 hours a day. Informed consent will be sought from every patient for a finger prick (capillary blood) and venous blood sample.\n\nBriefly, paired capillary (finger prick) and venous EDTA blood samples will be obtained from 317 patients meeting the inclusion criteria.\n\nProspective diagnostic accuracy study. The target accuracy index is the lower 95%CI of sensitivity, although we evaluate other important factors of diagnostic accuracy (see data analysis below).",[82,83,84,85,86,87,88,89],"Suspected Neutropenic Fever","Confirmed Neutropenic Fever","Severe Neutropenic Fever","Neutropenic Fever","Febrile Neutropenia","Febrile Neutropenia (FN)","Neutropenia","Neutropenia (Low White Blood Cell Count)",[91,92,93,94,95,96,97,98],"DUCATIS","neutropenic fever","febrile neutropenia","point-of-care","diagnostic accuracy","neutrophil","absolute neutrophil count","ANC","NOT_YET_RECRUITING","2026-10-21",{"date":102,"type":103},"2026-10-28","ACTUAL",{"date":105,"type":77},"2027-01-01",{"date":107,"type":77},"2028-03-31",{"name":5,"class":6},1]