[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100662432":3},{"organization":4,"outcomesModule":7,"designInfo":54,"detailedDescription":57,"studyPopulation":58,"armGroups":59,"interventions":53,"overallOfficials":66,"centralContacts":74,"locations":83,"responsibleParty":101,"collaborators":53,"id":103,"slug":104,"hasResults":105,"nctId":106,"briefTitle":107,"officialTitle":108,"acronym":109,"eligibilityCriteria":110,"healthyVolunteers":105,"sex":111,"minAge":112,"maxAge":53,"enrollmentInfo":113,"targetDuration":53,"studyType":116,"phases":53,"briefSummary":117,"conditions":118,"keywords":120,"overallStatus":124,"whyStopped":53,"lastUpdateSubmitDate":125,"lastUpdatePostDateStruct":126,"startDateStruct":129,"completionDateStruct":131,"leadSponsor":133,"locationsCount":134},{"fullName":5,"class":6},"University of Bern","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":53},[9],{"measure":10,"description":11,"timeFrame":12},"Cumulative active prosthesis-related clinical chairside time","Cumulative active prosthesis-related clinical chairside time per participant, in minutes, summed across all treatment sessions from the first prosthesis-related appointment to definitive insertion. Includes regular clinical scanning required for fabrication, framework try-in and clinical adjustment, if required. Excludes waiting and interruption time, study-specific scanning procedures and framework planning\u002Fdrawing. Reported separately for the digital and conventional fabrication workflows.","From the first prosthesis-related appointment through definitive insertion, an average of 6 weeks per participant.",[14,18,22,26,30,34,37,41,44,47,50],{"measure":15,"description":16,"timeFrame":17},"Number of clinical appointments","Number of clinical appointments per participant from the first prosthesis-related appointment to definitive insertion. Reported separately per workflow.","Through completion of prosthetic treatment, an average of 6 weeks.",{"measure":19,"description":20,"timeFrame":21},"Active dental laboratory technician time","Active dental laboratory technician working time per participant, in minutes, recorded for predefined fabrication steps; idle time between steps is excluded. Reported separately per workflow.","From receipt of the laboratory order to completion of framework fabrication, approximately 3-4 weeks after treatment initiation.",{"measure":23,"description":24,"timeFrame":25},"Quantitative framework fit","Three-dimensional surface distance between supporting tooth\u002Fridge surfaces and the framework fitting surface, in micrometers, in predefined measurement regions, based on superimposition of an intraoral scan without the framework, an intraoral scan with the seated framework and an extraoral scan of the finished framework. Continuous measure; no clinical cut-off. Reported separately per workflow.","At initial framework try-in, approximately 3-4 weeks after treatment initiation, before clinical adjustment.",{"measure":27,"description":28,"timeFrame":29},"Number of participants whose framework meets all clinical fit and stability criteria before adjustment","Four predefined yes\u002Fno criteria: seating of rests; adaptation of clasps and tooth-contacting components; adaptation of the major connector; stability under bilateral finger pressure. Reported separately per workflow.","At framework try-in, approximately 3-4 weeks after treatment initiation, before clinical adjustment.",{"measure":31,"description":32,"timeFrame":33},"Number of participants whose framework requires clinical adjustment","Whether clinical adjustment of the framework is required (yes\u002Fno). Reported separately per workflow.","At framework try-in, approximately 3-4 weeks after treatment initiation.",{"measure":35,"description":36,"timeFrame":33},"Active clinical adjustment time","Active clinical adjustment time per participant, in minutes, including participants without adjustment (0 minutes). Reported separately per workflow.",{"measure":38,"description":39,"timeFrame":40},"Number of participants with clinically acceptable final framework fit","Number of participants whose framework demonstrates clinically acceptable final fit (yes\u002Fno), assessed after completion of framework try-in and clinical adjustment, if required. Reported separately per workflow.","At completion of framework try-in, approximately 3-4 weeks after treatment initiation.",{"measure":42,"description":43,"timeFrame":17},"Number of participants whose framework requires laboratory rework","Rework documented with predefined cause categories. Reported separately per workflow.",{"measure":45,"description":46,"timeFrame":17},"Number of participants whose framework requires complete remake","Remake documented with predefined cause categories. Reported separately per workflow.",{"measure":48,"description":49,"timeFrame":17},"Total invoiced treatment cost","Total invoiced treatment cost per participant, in Swiss francs (CHF): invoiced prosthesis-related clinical services plus dental laboratory costs from treatment initiation to definitive insertion; unrelated dental services excluded. Restricted to participants treated in the specialist (non-student-course) setting. Reported separately per workflow.",{"measure":51,"description":52,"timeFrame":17},"Estimated personnel-related process cost","Estimated personnel-related process cost per participant, in Swiss francs (CHF): prospectively recorded active clinical and dental laboratory working times multiplied by predefined personnel cost rates (separate rates for clinical and dental laboratory time). Restricted to participants treated in the specialist (non-student-course) setting. Reported separately per workflow.",null,{"allocation":53,"interventionModel":53,"interventionModelDescription":53,"primaryPurpose":53,"observationalModel":55,"timePerspective":56,"maskingInfo":53},"COHORT","PROSPECTIVE","Clasp-retained removable partial dentures are a frequent routine treatment at the Department of Reconstructive Dentistry and Gerodontology, University of Bern, including the undergraduate student course; approximately 100 are produced per year. Both a conventional workflow and a digital workflow are used in routine care. For internal process control, systematic prospective data on process efficiency, framework fit, adjustment effort, and rework or remake are currently lacking for these routinely used workflows.\n\nThis is a single-center, prospective, observational cohort study embedded in routine care. The fabrication workflow (digital = Group 1; conventional = Group 2) is chosen clinically as part of regular treatment and is not assigned, randomized, or otherwise influenced by the study; the workflow actually used is documented prospectively. An approximately balanced representation of both workflows and Kennedy classes is sought over the data-collection period, but no fixed allocation rule or quota is applied. No causal or superiority comparison between workflows is intended.\n\nThe only study-specific procedure is two additional, non-invasive intraoral scans performed during the already-scheduled framework try-in: one scan without the framework and one with the fully seated framework. For the second scan, an intraorally approved scan spray is applied to visible metal surfaces and removed afterwards. The two scans together take about 10 minutes and require no additional appointment. In addition, the finished framework is scanned extraorally in the laboratory as a reference, which adds no patient time. All other examinations and treatment steps are part of routine care.\n\nOutcomes are described separately per workflow and setting using descriptive statistics. No sample-size calculation and no confirmatory hypothesis testing are performed.","Consecutive patients with an indication for a clasp-retained removable partial denture treated at the Department of Reconstructive Dentistry and Gerodontology, University of Bern (clinical, postgraduate and undergraduate student-course settings), during the data-collection period who consent to the two additional intraoral scans.",[60,63],{"label":61,"type":53,"description":62,"interventionNames":53},"Digital workflow","Patients whose clasp-retained RPD is fabricated using the digital workflow (intraoral scan-based CAD and digital framework fabrication) as selected in routine clinical care. Group membership reflects the clinically chosen fabrication workflow and is not assigned by the study.",{"label":64,"type":53,"description":65,"interventionNames":53},"Conventional workflow","Patients whose clasp-retained RPD is fabricated using the conventional workflow as selected in routine clinical care. Group membership reflects the clinically chosen fabrication workflow and is not assigned by the study.",[67,71],{"name":68,"affiliation":69,"role":70},"Sebastian Hinz, Dr. med. dent.","University of Bern, Department of Reconstructive Dentistry and Gerodontology","PRINCIPAL_INVESTIGATOR",{"name":72,"affiliation":69,"role":73},"Martin Schimmel, Prof. Dr. med. dent.","STUDY_CHAIR",[75,79],{"name":68,"role":76,"phone":77,"phoneExt":53,"email":78},"CONTACT","+41 31 684 07 41","sebastian.hinz@unibe.ch",{"name":80,"role":76,"phone":81,"phoneExt":53,"email":82},"Nicole Schenk, Dr. med. dent.","+41 31 684 07 39","nicole.schenk@unibe.ch",[84],{"facility":69,"status":53,"city":85,"state":86,"zip":87,"country":88,"countryCode":89,"cosmosGeoPoint":90,"geoPoint":95,"contacts":96},"Bern","Canton of Bern","3010","Switzerland","CH",{"type":91,"coordinates":92},"Point",[93,94],7.44744,46.94809,{"lat":94,"lon":93},[97,99],{"name":68,"role":76,"phone":98,"phoneExt":53,"email":78},"+41 31 68407 41",{"name":80,"role":76,"phone":100,"phoneExt":53,"email":82},"+41 31 684 0739",{"type":102,"investigatorFullName":53,"investigatorTitle":53,"investigatorAffiliation":53,"oldNameTitle":53,"oldOrganization":53},"SPONSOR","100662432","digital-and-conventional-clasp-retained-partial-dentures-digiclasp-100662432",false,"NCT07903662","Digital and Conventional Clasp-retained Partial Dentures (DIGICLASP)","Digital and Conventional Fabrication of Clasp-retained Removable Partial Dentures: A Prospective Observational Evaluation of Clinical and Dental Laboratory Processes","DIGICLASP","Inclusion Criteria:\n\n* Adults aged 18 years or older\n* Indication for a clasp-retained removable partial denture, treated at the department during the data-collection period\n* Consent to the two additional, non-invasive intraoral scans performed during the framework try-in\n\nExclusion Criteria:\n\n* No consent to the study-specific additional measures\n* Minors\n* Persons unable to give informed consent","ALL","18 Years",{"count":114,"type":115},70,"ESTIMATED","OBSERVATIONAL","This single-center prospective observational cohort study evaluates two fabrication workflows already in routine clinical use for clasp-retained removable partial dentures (RPDs): a digital workflow (Group 1) and a conventional workflow (Group 2). The fabrication workflow is selected as part of routine clinical care and is not assigned by the study. Separately for the digital and conventional workflows, the study describes the cumulative active clinical chairside time (primary), together with the number of clinical appointments, dental laboratory process times, quantitative and clinical framework fit, adjustment effort, final fit, and the frequency of rework and remake. Consecutive patients treated at the Department of Reconstructive Dentistry and Gerodontology, University of Bern, are included over a 36-month period. The analysis is purely descriptive; no causal inference, confirmatory hypothesis testing, or superiority assessment is planned.",[119],"Partial Edentulism",[121,122,123],"Jaw","Edentulous","Partially","NOT_YET_RECRUITING","2026-10-22",{"date":127,"type":128},"2026-10-29","ACTUAL",{"date":130,"type":115},"2026-11",{"date":132,"type":115},"2030-03",{"name":5,"class":6},1]