[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100664922":3},{"organization":4,"outcomesModule":7,"designInfo":58,"detailedDescription":57,"studyPopulation":57,"armGroups":65,"interventions":76,"overallOfficials":82,"centralContacts":86,"locations":91,"responsibleParty":104,"collaborators":57,"id":108,"slug":109,"hasResults":110,"nctId":111,"briefTitle":112,"officialTitle":113,"acronym":114,"eligibilityCriteria":115,"healthyVolunteers":110,"sex":116,"minAge":117,"maxAge":57,"enrollmentInfo":118,"targetDuration":57,"studyType":121,"phases":122,"briefSummary":124,"conditions":125,"keywords":57,"overallStatus":127,"whyStopped":57,"lastUpdateSubmitDate":128,"lastUpdatePostDateStruct":129,"startDateStruct":132,"completionDateStruct":134,"leadSponsor":136,"locationsCount":137},{"fullName":5,"class":6},"Mayo Clinic","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":57},[9],{"measure":10,"description":11,"timeFrame":12},"Number of Participants With Successful Delivery of Ablation Lesions Using the Dual-Energy THERMOCOOL SMARTTOUCH SF Catheter With the TRUPULSE Generator","Feasibility is defined as successful delivery of ablation energy at the targeted premature ventricular complex (PVC) site. Delivery counts as successful only if there is no study device deficiency or malfunction that prevents energy delivery, and no need to convert to a bailout ablation approach.","During the index ablation procedure",[14,18,22,26,29,33,37,41,45,48,51,54],{"measure":15,"description":16,"timeFrame":17},"Acute procedural success","Number of participants with elimination of the target premature ventricular contraction by the end of the procedure.","End of the ablation procedure",{"measure":19,"description":20,"timeFrame":21},"Participants with greater than 80% reduction in target PVC burden","Number of participants with greater than 80% reduction from baseline in the burden of the target premature ventricular contraction on Holter monitoring.","1 month, 6 months",{"measure":23,"description":24,"timeFrame":25},"Change in Short Form Health Survey (SF-36) score","The 36-Item Short Form Health Survey (SF-36) is a participant-reported questionnaire that assesses health-related quality of life across eight domains: physical functioning, role limitations due to physical health, bodily pain, general health, vitality, social functioning, role limitations due to emotional problems, and mental health. Total scores range from 0 to 100. Higher scores indicate better health status.","Baseline, 1 month, 6 months",{"measure":27,"description":28,"timeFrame":25},"Change in EQ-5D score","The EQ-5D is a participant-reported measure of health-related quality of life covering five dimensions: mobility, self-care, usual activities, pain\u002Fdiscomfort, and anxiety\u002Fdepression. Responses across the five dimensions define the participant's health state. Higher scores indicate better health.",{"measure":30,"description":31,"timeFrame":32},"Number of Participants With New Coronary Artery Stenosis on Coronary CT Angiography at 6 Months After Ablation","Total number of patients with new-onset coronary luminal stenosis found on CT coronary angiography","6 months",{"measure":34,"description":35,"timeFrame":36},"Total Procedure Time","Total procedure time will be reported in minutes","From start to finish of index ablation procedure",{"measure":38,"description":39,"timeFrame":40},"Electrogram endpoints","EGM amplitude changes after PF, RF, and RF-PF lesion delivery","Intraprocedure",{"measure":42,"description":43,"timeFrame":44},"Ablation Lesion Depth","Maximum depth of the ablation lesion at the target premature ventricular complex (PVC) site. Depth is measured from the endocardial surface on late gadolinium enhancement (LGE) cardiac MRI. Only participants with an evaluable post-ablation MRI are analyzed. Reported in millimeters.","1 month and 6 months after ablation",{"measure":46,"description":47,"timeFrame":44},"Ablation Lesion Width","Maximum width of the ablation lesion at the target PVC site, measured on LGE cardiac MRI. Only participants with an evaluable post-ablation MRI are analyzed. Reported in millimeters.",{"measure":49,"description":50,"timeFrame":44},"Ablation Lesion Volume","Total volume of the ablation lesion at the target PVC site, measured on LGE cardiac MRI. Only participants with an evaluable post-ablation MRI are analyzed. Reported in cubic centimeters.",{"measure":52,"description":53,"timeFrame":12},"Number of Radiofrequency (RF) Lesions Delivered per Participant","Total number of RF lesions delivered with the study catheter during the index procedure",{"measure":55,"description":56,"timeFrame":12},"Number of Pulsed-Field (PF) Lesions Delivered per Participant","Total number of PF lesions delivered with the study catheter during the index procedure",null,{"allocation":59,"interventionModel":60,"interventionModelDescription":61,"primaryPurpose":62,"observationalModel":57,"timePerspective":57,"maskingInfo":63},"RANDOMIZED","PARALLEL","Randomized assignment to RF-PF vs PF-PF arm, with crossover optionality","TREATMENT",{"masking":64,"maskingDescription":57,"whoMasked":57},"NONE",[66,72],{"label":67,"type":68,"description":69,"interventionNames":70},"RF-PF Sequential Ablation","EXPERIMENTAL","Participants are assigned to receive radiofrequency (RF) followed by pulsed-field (PF) at each selected treatment site. For each PF treatment, 24 PF bursts are delivered. Up to three stacked lesions may be performed at the same location.",[71],"Device: Dual Energy THERMOCOOL SMARTTOUCH™ SF (STSF) Bi-Directional Navigation catheter with TRUPULSE™ Generator",{"label":73,"type":68,"description":74,"interventionNames":75},"PF-Only Ablation","Participants are assigned to receive pulsed-field (PF) alone at each selected treatment site. For each PF treatment, 24 PF bursts are delivered. Up to three stacked lesions may be performed at the same location.",[71],[77],{"type":78,"name":79,"description":80,"armGroupLabels":81,"otherNames":57},"DEVICE","Dual Energy THERMOCOOL SMARTTOUCH™ SF (STSF) Bi-Directional Navigation catheter with TRUPULSE™ Generator","The THERMOCOOL SMARTTOUCH™ SF Bi-Directional Navigation Catheter is an irrigated, contact-force-sensing catheter used to map the heart and deliver radiofrequency (RF) or pulsed-field (PF) energy to selected treatment sites. The catheter is connected to the TRUPULSE™ Generator, which provides both energy types, and to the nGEN™ Pump, which controls saline irrigation. The system is used with the CARTO™ 3 electroanatomic mapping system and workstation with the VISITAG SURPOINT™ Module to display heart anatomy, catheter location, catheter-to-tissue contact, and treatment information during the procedure.",[73,67],[83],{"name":84,"affiliation":5,"role":85},"Konstantinos Siontis, MD","PRINCIPAL_INVESTIGATOR",[87],{"name":84,"role":88,"phone":89,"phoneExt":57,"email":90},"CONTACT","507-255-0774","siontis.konstantinos@mayo.edu",[92],{"facility":5,"status":57,"city":93,"state":94,"zip":95,"country":96,"countryCode":97,"cosmosGeoPoint":98,"geoPoint":103,"contacts":57},"Rochester","Minnesota","55905","United States","US",{"type":99,"coordinates":100},"Point",[101,102],-92.4699,44.02163,{"lat":102,"lon":101},{"type":105,"investigatorFullName":106,"investigatorTitle":107,"investigatorAffiliation":5,"oldNameTitle":57,"oldOrganization":57},"SPONSOR_INVESTIGATOR","Konstantinos Siontis","Principal Investigator","100664922","dual-energy-focal-ablation-of-premature-ventricular-complexes-100664922",false,"NCT07935265","Dual Energy Focal Ablation of Premature Ventricular Complexes","Dual Energy (RF\u002FPF) Focal Ablation of Premature Ventricular Complexes: the DUAL-PVC Prospective Clinical Trial","DUAL-PVC","Inclusion Criteria:\n\n* ≥10% burden of the target PVC on ambulatory rhythm monitoring within 3 months prior to enrollment. The qualifying ambulatory monitor may be of any duration (1-30 days) per standard of care and may be distinct from the baseline 12-lead Holter required within 30 days before ablation\n* Guideline-supported indication for first-time or redo catheter ablation of PVCs at the judgment of the electrophysiologist. Specifically:\n\n  * Patients with symptomatic PVCs for whom antiarrhythmic medications are ineffective, not tolerated, or not the patient's preference.\n  * Suspected or confirmed PVC-induced cardiomyopathy\n  * Enrollment of patients requiring a redo procedure will be capped at 30% of planned enrollment (n=18) if the target PVC is the same or similar to that targeted in previous procedure(s), per review of the study investigator\n* Patients with and without known structural heart disease are eligible\n* Ability to undergo study-directed cardiac MRI pre- and post-procedure\n* Ability to undergo study-directed post-ablation coronary CT angiography\n* Ability to provide written informed consent\n\nExclusion Criteria:\n\n* LVEF \\\u003C35%\n* NYHA class IV\n* Presence of multifocal PVCs (\\>=3 distinct morphologies) on available pre-baseline standard-of-care ambulatory monitor and ECG tracings per the review of the study team.\n* PVCs attributable to a reversible or non-cardiac cause (e.g., electrolyte imbalance or active thyroid disease).\n* History of sustained VT or VF.\n* Current or recent (\\\u003C4 weeks) decompensated heart failure.\n* Active systemic infection.\n* Contraindication to LGE-MRI or contrast CT.\n* Known allergy to iodinated contrast dye that cannot be adequately managed with pre-medication protocol.\n* Thrombocytopenia (platelet count \\\u003C50,000\u002Fmm³) or known coagulopathy.\n* Contraindication to systemic anticoagulation.\n* Severe valvular disease requiring future intervention.\n* Mechanical valve prosthesis.\n* Pregnancy.\n* Recent acute coronary syndrome (\\\u003C6 months).\n* Un-revascularized coronary artery disease.\n* Presence of left ventricular assist device (LVAD) or transplanted heart.\n* Presence of intracardiac thrombus.\n* Current use of inotropes.\n* Recent stroke or TIA (\\\u003C6 months).\n* Presence of a systemic illness likely to limit survival to \\\u003C1 year.\n* Patient enrollment in other clinical study that could conflict with the current investigation.","ALL","18 Years",{"count":119,"type":120},60,"ESTIMATED","INTERVENTIONAL",[123],"NA","The purpose of this research is to understand whether a dual-energy catheter ablation system that uses radiofrequency (RF) and pulsed-field (PF) energy can safely and effectively treat premature ventricular contractions (PVCs).",[126],"Premature Ventricular Contractions","NOT_YET_RECRUITING","2026-11-08",{"date":130,"type":131},"2026-11-13","ACTUAL",{"date":133,"type":120},"2027-01",{"date":135,"type":120},"2029-06",{"name":106,"class":6},1]