[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100661875":3},{"organization":4,"outcomesModule":7,"designInfo":91,"detailedDescription":94,"studyPopulation":95,"armGroups":96,"interventions":102,"overallOfficials":90,"centralContacts":108,"locations":114,"responsibleParty":127,"collaborators":90,"id":131,"slug":132,"hasResults":133,"nctId":134,"briefTitle":135,"officialTitle":136,"acronym":137,"eligibilityCriteria":138,"healthyVolunteers":133,"sex":139,"minAge":140,"maxAge":90,"enrollmentInfo":141,"targetDuration":90,"studyType":144,"phases":90,"briefSummary":145,"conditions":146,"keywords":150,"overallStatus":117,"whyStopped":90,"lastUpdateSubmitDate":159,"lastUpdatePostDateStruct":160,"startDateStruct":163,"completionDateStruct":165,"leadSponsor":167,"locationsCount":168},{"fullName":5,"class":6},"Buca Seyfi Demirsoy State Hospital","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":90},[9],{"measure":10,"description":11,"timeFrame":12},"Correlation between early heart rate variability (ln RMSSD) and quality of recovery (ObsQoR-11T)","Correlation (Pearson or Spearman, per distribution) between early postoperative HRV (natural log of RMSSD over the first 24 hours) and the ObsQoR-11T total score (range 0-110; higher = better recovery) at 24 hours postpartum.","First 24 hours postpartum",[14,18,21,25,28,31,34,37,40,44,47,50,53,56,60,64,67,70,74,77,80,83,86],{"measure":15,"description":16,"timeFrame":17},"ObsQoR-11T total score","Obstetric Quality of Recovery score, validated Turkish version (ObsQoR-11T); 11 items, total range 0-110 (higher = better recovery).","24 and 48 hours postpartum",{"measure":19,"description":20,"timeFrame":17},"Subjective sleep quality (Richards-Campbell Sleep Questionnaire, RCSQ)","RCSQ total score, calculated as the mean of the first 5 items (range 0-100; higher = better sleep).",{"measure":22,"description":23,"timeFrame":24},"Standard deviation of NN intervals (SDNN)","Time-domain heart rate variability computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform. Reported in milliseconds from analyzable nocturnal 5-minute segments.","First 48 hours after cesarean delivery",{"measure":26,"description":27,"timeFrame":24},"Proportion of successive NN intervals differing by more than 50 ms (pNN50)","Time-domain heart rate variability computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform. Reported as a percentage of successive interval pairs from analyzable nocturnal 5-minute segments.",{"measure":29,"description":30,"timeFrame":24},"Low-frequency power of heart rate variability (LF)","Frequency-domain heart rate variability (0.04-0.15 Hz) computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform. Reported as absolute power in squared milliseconds from analyzable nocturnal 5-minute segments.",{"measure":32,"description":33,"timeFrame":24},"High-frequency power of heart rate variability (HF)","Frequency-domain heart rate variability (0.15-0.40 Hz) computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform. Reported as absolute power in squared milliseconds from analyzable nocturnal 5-minute segments.",{"measure":35,"description":36,"timeFrame":24},"Ratio of low-frequency to high-frequency power (LF\u002FHF)","Ratio of absolute low-frequency to high-frequency heart rate variability power, computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform. Reported as a unitless ratio from analyzable nocturnal 5-minute segments.",{"measure":38,"description":39,"timeFrame":24},"Ratio of Poincare plot descriptors SD1 to SD2","Non-linear heart rate variability index computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform. Reported as a unitless ratio from analyzable nocturnal 5-minute segments.",{"measure":41,"description":42,"timeFrame":43},"Natural log of RMSSD at fixed postoperative time windows","Natural logarithm of the root mean square of successive beat-to-beat interval differences, computed from raw beat-to-beat intervals recorded by a wrist-worn wearable (Garmin Vivosmart 5) and processed on the Fitrockr platform, at fixed postoperative windows. Reported as ln(ms).","12, 24, 36 and 48 hours after cesarean delivery",{"measure":45,"description":46,"timeFrame":43},"Mean heart rate at fixed postoperative time windows","Mean heart rate derived from the wrist-worn wearable (Garmin Vivosmart 5) via the Fitrockr platform at fixed postoperative windows, reported in beats per minute.",{"measure":48,"description":49,"timeFrame":24},"Total sleep time measured by the wearable device","Total sleep time derived from the wrist-worn wearable (Garmin Vivosmart 5) via the Fitrockr platform, reported in minutes.",{"measure":51,"description":52,"timeFrame":24},"Sleep efficiency measured by the wearable device","Total sleep time divided by time in bed, derived from the wrist-worn wearable (Garmin Vivosmart 5) via the Fitrockr platform and reported as a percentage.",{"measure":54,"description":55,"timeFrame":24},"Number of awakenings measured by the wearable device","Count of awakenings during the sleep period, derived from the wrist-worn wearable (Garmin Vivosmart 5) via the Fitrockr platform.",{"measure":57,"description":58,"timeFrame":59},"Agreement between objective (device) and subjective (RCSQ) sleep","Correlation\u002Fagreement between wearable-derived sleep parameters and the RCSQ score.","First 48 hours postpartum",{"measure":61,"description":62,"timeFrame":63},"Pain at rest on a numeric rating scale","Patient-reported pain intensity at rest on a numeric rating scale from 0 to 10, where 0 is no pain and 10 is the worst imaginable pain.","24 and 48 hours after cesarean delivery",{"measure":65,"description":66,"timeFrame":63},"Pain on movement on a numeric rating scale","Patient-reported pain intensity on movement on a numeric rating scale from 0 to 10, where 0 is no pain and 10 is the worst imaginable pain.",{"measure":68,"description":69,"timeFrame":24},"Total opioid consumption in oral morphine milligram equivalents","Cumulative opioid dose administered after cesarean delivery, converted to oral morphine milligram equivalents and recorded from the medication chart.",{"measure":71,"description":72,"timeFrame":73},"Change in ObsQoR-11T from 24 to 48 hours","Difference in ObsQoR-11T total score (range 0-110; higher = better recovery) between 24 and 48 hours postpartum, and its association with early HRV and sleep.","24 to 48 hours postpartum",{"measure":75,"description":76,"timeFrame":24},"Mean device-derived stress score","Mean of minute-level stress scores recorded by the wrist-worn wearable (Garmin Vivosmart 5; proprietary 0-100 scale derived from heart rate variability, higher values indicate greater physiological stress) and exported via the Fitrockr platform, averaged over all valid minutes. Reported as score units on a 0-100 scale.",{"measure":78,"description":79,"timeFrame":24},"Proportion of valid wear time in the rest stress state","Percentage of valid minutes in which the wrist-worn wearable (Garmin Vivosmart 5) recorded a stress score of 0-25 (rest state on the device's proprietary 0-100 scale), exported via the Fitrockr platform.",{"measure":81,"description":82,"timeFrame":24},"Number of stress episodes per 24 hours","Number of episodes of at least 3 consecutive minutes with a device-derived stress score above 50 (medium or high stress on the Garmin Vivosmart 5 proprietary 0-100 scale), exported via the Fitrockr platform and normalized to episodes per 24 hours of valid wear time.",{"measure":84,"description":85,"timeFrame":24},"Median stress recovery time after stress episodes","Median time in minutes from the end of each stress episode (at least 3 consecutive minutes with a device-derived stress score above 50) to the first subsequent minute with a stress score of 25 or below (rest state), computed from minute-level Garmin Vivosmart 5 stress scores exported via the Fitrockr platform.",{"measure":87,"description":88,"timeFrame":89},"Overnight Body Battery charge","Change in the device-derived Body Battery energy score (Garmin Vivosmart 5; proprietary 0-100 scale estimated from heart rate variability, stress, sleep and activity) from the start to the end of the main nocturnal sleep period detected by the device, exported via the Fitrockr platform. Reported as score units on a 0-100 scale; positive values indicate recharge.","First and second postoperative nights (within 48 hours after cesarean delivery)",null,{"allocation":90,"interventionModel":90,"interventionModelDescription":90,"primaryPurpose":90,"observationalModel":92,"timePerspective":93,"maskingInfo":90},"COHORT","PROSPECTIVE","Background: Cesarean section is among the most common surgical procedures, and objective assessment of postpartum recovery may help improve quality of care. Wearable-derived autonomic (HRV) and sleep measures are candidate objective correlates of recovery but have not been characterized in the early in-hospital cesarean period.\n\nObjectives \u002F Hypotheses:\n\n* H1: Higher early HRV (e.g., RMSSD, HF power) is associated with better ObsQoR-11T score.\n* H2: Shorter \u002F more fragmented sleep (sleep duration, efficiency, number of awakenings) is associated with lower ObsQoR-11T score.\n\nProcedures: Consenting women receive a Garmin Vívosmart 5 on the non-dominant wrist immediately postoperatively; the device remains in hospital only (\\~48 hours) and is disinfected\u002Frecharged between patients. Raw beat-to-beat intervals and computed HRV metrics (RMSSD, SDNN, pNN50, LF, HF, LF\u002FHF, SD1\u002FSD2), continuous heart rate, sleep, and minute-level device-derived stress scores and Body Battery are obtained from the Fitrockr platform. Patient-reported outcomes (ObsQoR-11T, RCSQ, numeric rating scale \\[NRS\\] pain) and clinical\u002Fdemographic data are collected via a case report form at 24 and 48 hours.\n\nHRV analysis windows and signal-quality criteria: nocturnal 5-minute stable segments at fixed hours; beats deviating \\>20% from neighboring intervals are corrected\u002Fremoved; a segment is analyzable if the corrected\u002Fremoved beat proportion is ≤5%; the primary window (first 24 hours) requires at least one valid nocturnal segment and ≥80% device wear time within the window.\n\nStatistics: The primary analysis is the association between early (first 24 hours) ln RMSSD and ObsQoR-11T at 24 hours, using Pearson or Spearman correlation according to distribution, with adjustment for age, body mass index, and anesthesia type. The single pre-specified primary test is reported without multiplicity correction; secondary\u002Fexploratory analyses apply Benjamini-Hochberg false discovery rate control (q\\\u003C0.05). Missing data: complete-case for the primary analysis, with multiple-imputation sensitivity analysis. Device-derived stress and Body Battery outcomes are secondary, exploratory measures; because both are derived from heart rate variability, they are not independent of the primary exposure (ln RMSSD) and will be reported descriptively and in exploratory correlation analyses. The proportion of valid minutes will be reported for each participant.","Adult women delivering by cesarean section at a single tertiary obstetrics and gynecology clinic.",[97],{"label":98,"type":90,"description":99,"interventionNames":100},"Women after cesarean delivery","Adult women who delivered by cesarean section, monitored with a wrist-worn wearable (Garmin Vívosmart 5) for the first 48 postoperative hours.",[101],"Device: Wearable-derived heart rate variability and sleep monitoring",[103],{"type":104,"name":105,"description":106,"armGroupLabels":107,"otherNames":90},"DEVICE","Wearable-derived heart rate variability and sleep monitoring","Objective HRV, heart rate and sleep metrics derived from a consumer wrist wearable (Garmin Vivosmart 5) via the Fitrockr platform during the first 48 postoperative hours. Measurement only; no clinical intervention is assigned and device data do not inform clinical care.",[98],[109],{"name":110,"role":111,"phone":112,"phoneExt":90,"email":113},"Egehan Bilen, MD","CONTACT","+90 539 342 28 46","egehanbilen@gmail.com",[115],{"facility":116,"status":117,"city":118,"state":90,"zip":119,"country":120,"countryCode":90,"cosmosGeoPoint":121,"geoPoint":126,"contacts":90},"Buca Seyfi Demirsoy Training and Research Hospital, Department of Obstetrics and Gynecology","RECRUITING","Izmir","35390","Turkey (Türkiye)",{"type":122,"coordinates":123},"Point",[124,125],27.13838,38.41273,{"lat":125,"lon":124},{"type":128,"investigatorFullName":129,"investigatorTitle":130,"investigatorAffiliation":5,"oldNameTitle":90,"oldOrganization":90},"PRINCIPAL_INVESTIGATOR","Egehan Bilen","Principal Investigator","100661875","early-heart-rate-variability-and-sleep-and-quality-of-recovery-after-cesarean-delivery-100661875",false,"NCT07897331","Early Heart Rate Variability and Sleep and Quality of Recovery After Cesarean Delivery","Association of Early Postoperative Heart Rate Variability and Sleep Parameters With Quality of Recovery After Cesarean Delivery: A Prospective Observational Cohort Study","Otonom-CS","Inclusion Criteria:\n\n* Women aged 18 years or older who delivered by cesarean section\n* Provided written informed consent\n* Clinically able to wear the wrist device throughout the first 48 postoperative hours\n\nExclusion Criteria:\n\n* Known significant cardiac arrhythmia (e.g., atrial fibrillation) or a permanent pacemaker (invalidates HRV analysis)\n* Severe maternal complication requiring intensive care\n* Skin or limb condition precluding device placement\n* Inability to provide informed consent or to communicate\n\n(Conditions or medications that may substantially affect HRV are recorded and relevant cases excluded as needed.)","FEMALE","18 Years",{"count":142,"type":143},82,"ESTIMATED","OBSERVATIONAL","This prospective single-center observational cohort study investigates whether objectively measured early postoperative heart rate variability (HRV) and sleep parameters are associated with patient-reported quality of recovery after cesarean delivery. Women who deliver by cesarean section wear a consumer wrist device (Garmin Vívosmart 5) on the non-dominant wrist during the in-hospital period (first 48 hours). HRV metrics (e.g., RMSSD), continuous heart rate, and sleep are derived from raw beat-to-beat intervals via the Fitrockr platform. Quality of recovery is measured with the validated Turkish Obstetric Quality-of-Recovery score (ObsQoR-11T) at 24 and 48 hours, and subjective sleep with the Richards-Campbell Sleep Questionnaire (RCSQ). The primary hypothesis is that higher early HRV (particularly RMSSD) and better sleep are associated with higher ObsQoR-11T at postoperative day 1 (24 hours). The wearable is used for research purposes only and does not inform any clinical decision; routine care proceeds independently of the study.",[147,148,149],"Recovery of Function","Postoperative Period","Cesarean Section",[151,152,153,154,155,156,157,158],"Heart Rate Variability","Sleep","Wearable Device","Quality of Recovery","ObsQoR-11T","Richards-Campbell Sleep Questionnaire","Cesarean Delivery","Autonomic Function","2026-11-21",{"date":161,"type":162},"2026-11-24","ACTUAL",{"date":164,"type":162},"2026-11-11",{"date":166,"type":143},"2027-04",{"name":5,"class":6},1]