[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100660127":3},{"organization":4,"outcomesModule":7,"designInfo":49,"detailedDescription":52,"studyPopulation":53,"armGroups":54,"interventions":64,"overallOfficials":72,"centralContacts":76,"locations":82,"responsibleParty":100,"collaborators":48,"id":103,"slug":104,"hasResults":105,"nctId":106,"briefTitle":107,"officialTitle":108,"acronym":109,"eligibilityCriteria":110,"healthyVolunteers":105,"sex":111,"minAge":112,"maxAge":113,"enrollmentInfo":114,"targetDuration":48,"studyType":117,"phases":48,"briefSummary":118,"conditions":119,"keywords":123,"overallStatus":129,"whyStopped":48,"lastUpdateSubmitDate":130,"lastUpdatePostDateStruct":131,"startDateStruct":134,"completionDateStruct":136,"leadSponsor":138,"locationsCount":139},{"fullName":5,"class":6},"Ankara City Hospital Bilkent","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":48},[9],{"measure":10,"description":11,"timeFrame":12},"Percentage change in maternal plasma oxytocin concentration from baseline to T-Eff","Calculated as: \\[(T-Eff plasma oxytocin - T-0 plasma oxytocin) \u002F T-0 plasma oxytocin\\] × 100. Positive values indicate an increase in oxytocin; negative values indicate suppression. Plasma oxytocin concentration will be measured in pg\u002FmL using an enzyme-linked immunosorbent assay (ELISA).","From T-0 (immediately before DPEA) to T-Eff (30 minutes after onset of effective analgesia defined as VAS\u003C2); total duration approximately 35-45 minutes depending on time to VAS\u003C2. (VAS: Visual analogue scale 0-10 poits. 10 means worst pain)",[14,18,22,26,30,33,36,40,44],{"measure":15,"description":16,"timeFrame":17},"Time to effective analgesia (VAS\u003C2). (VAS: Visual analogue scale 0-10 poits. 10 means worst pain)","Duration in minutes from DPEA injection to the first time point when patient reports VAS pain score \\\u003C2. (VAS: Visual analogue scale 0-10 poits. 10 means worst pain)","Within 30 minutes of DPEA administration",{"measure":19,"description":20,"timeFrame":21},"Cervical dilation progression rate","Rate of cervical dilation in cm\u002Fhour from DPEA administration to delivery.","From DPEA to delivery (variable, typically 1-6 hours)",{"measure":23,"description":24,"timeFrame":25},"Bromage motor block score","Degree of motor block assessed by Bromage scale (0=no block, 3=complete block).","At delivery",{"measure":27,"description":28,"timeFrame":29},"Need for post-T-Eff oxytocin augmentation","Binary outcome: whether exogenous oxytocin was initiated after T-Eff for labor augmentation (yes\u002Fno), start time, and initial dose","From T-Eff to delivery",{"measure":31,"description":32,"timeFrame":25},"Mode of delivery","Vaginal, instrumental, or cesarean delivery; if cesarean, indication is recorded.",{"measure":34,"description":35,"timeFrame":25},"First and second stage durations","Duration of first stage (from DPEA to full dilation) and second stage (full dilation to delivery) in minutes.",{"measure":37,"description":38,"timeFrame":39},"Neonatal Apgar scores (0-10 points. 10 is the best score)","Apgar scores at 1 and 5 minutes of life.","At 1 and 5 minutes after delivery",{"measure":41,"description":42,"timeFrame":43},"Umbilical cord blood pH","pH value from umbilical cord arterial blood.","Immediately after delivery",{"measure":45,"description":46,"timeFrame":47},"Hemodynamic parameters","Systolic blood pressure (SBP) and heart rate (HR) at baseline, 5, 10, 15, 20, and 30 minutes after DPEA","0-30 minutes after DPEA",null,{"allocation":48,"interventionModel":48,"interventionModelDescription":48,"primaryPurpose":48,"observationalModel":50,"timePerspective":51,"maskingInfo":48},"COHORT","PROSPECTIVE","Background:\n\nOxytocin is a neuropeptide produced in the hypothalamus and released from the posterior pituitary in a pulsatile manner during labor. Through the Ferguson reflex, oxytocin release increases substantially as labor progresses, with peak release around delivery. The effect of neuraxial analgesia on oxytocin dynamics has been controversial. Previous studies have reported both suppression and no significant change in oxytocin levels following epidural analgesia. DPEA, a technique that involves controlled dural puncture to enhance epidural local anesthetic spread without intrathecal drug administration, provides an opportunity to investigate whether the oxytocin response to neuraxial analgesia varies according to the stage of labor.\n\nDesign:\n\nThis is a prospective, comparative, observational cohort study. Patients are not randomized. Participants are classified into two groups according to cervical dilation at the time of DPEA request: Early Labor Group (≤5 cm) and Late Labor Group (≥6 cm). All participants receive standardized DPEA. Laboratory personnel performing oxytocin assays are blinded to group assignment.\n\nDPEA protocol: After sterile preparation and local infiltration with 1% lidocaine, the epidural space is identified at L3-L4 or L4-L5 using a 17G Tuohy needle and loss-of-resistance technique. A 26G spinal needle is passed through the Tuohy needle to perform dural puncture, and cerebrospinal fluid return is confirmed. No intrathecal drug is administered. The spinal needle is withdrawn and the epidural catheter is advanced 5 cm into the epidural space. Following negative aspiration and an appropriate test dose, a total volume of 15 mL containing 0.1% bupivacaine and 100 µg fentanyl is administered through the epidural catheter. Maintenance analgesia is provided with patient-controlled epidural analgesia (PCEA).\\*\\* Blood sampling: A baseline blood sample (T-0) is obtained immediately before DPEA. The time at which the patient first reports a VAS pain score \\\u003C2 is recorded as T-VAS; no blood sample is obtained at this time. The second blood sample (T-Eff) is obtained 30 minutes after T-VAS. Plasma samples are stored at -80°C until batch analysis for oxytocin concentration.\\*\\* The primary outcome is the percentage change in maternal plasma oxytocin concentration from T-0 to T-Eff, calculated as: \\[(T-Eff - T-0) \u002F T-0\\] × 100. Patients who receive exogenous oxytocin before the T-0 blood sample are excluded from the study.","Pregnant women aged 18-40 years admitted to the Labor Ward of Ankara Bilkent City Hospital with spontaneous labor who request Dural Puncture Epidural Analgesia (DPEA). Participants will be classified according to cervical dilation at the time of DPEA request as Early Labor Group (≤5 cm) or Late Labor Group (≥6 cm). Eligible participants will have a singleton, vertex pregnancy at 37-41 weeks of gestation and ASA physical status II.",[55,60],{"label":56,"type":48,"description":57,"interventionNames":58},"Early Labor Group","Pregnant women in spontaneous labor who request Dural Puncture Epidural Analgesia (DPEA) when cervical dilation is 5 cm or less. All receive standardized DPEA with a total volume of 15 mL containing 0.1% bupivacaine and 100 µg fentanyl via epidural catheter after dural puncture (26G) without intrathecal drug injection. Plasma oxytocin measured at T-0 (before DPEA) and T-Eff (30 min after VAS\\\u003C2).",[59],"Procedure: Dural Puncture Epidural Analgesia (DPEA)",{"label":61,"type":48,"description":62,"interventionNames":63},"Late Labor Group","Pregnant women in spontaneous labor who request Dural Puncture Epidural Analgesia (DPEA) when cervical dilation is 6 cm or greater. DPEA protocol identical to Early Group. Plasma oxytocin measured at same timepoints (T-0 and T-Eff).",[59],[65,70],{"type":66,"name":67,"description":68,"armGroupLabels":69,"otherNames":48},"PROCEDURE","Dural Puncture Epidural Analgesia (DPEA)","Standard clinical DPEA procedure: Combined spinal-epidural kit used to locate epidural space at L3-L4 or L4-L5 with 17G Tuohy needle (loss of resistance). A 26G spinal needle is passed through the Tuohy needle to perform dural puncture; CSF return is confirmed. NO intrathecal drug is administered. The spinal needle is withdrawn, the epidural catheter is advanced 5 cm into the epidural space. After negative aspiration and test dose, 15 mL of 0.1% bupivacaine is administered through the epidural catheter. Maintenance analgesia is provided via patient-controlled epidural analgesia (PCEA).",[56],{"type":66,"name":67,"description":68,"armGroupLabels":71,"otherNames":48},[61],[73],{"name":74,"affiliation":5,"role":75},"Esra UYAR TÜRKYILMAZ, MD, Assoc. Prof.","PRINCIPAL_INVESTIGATOR",[77],{"name":78,"role":79,"phone":80,"phoneExt":48,"email":81},"Esra Uyar Türkyılmaz, MD, Assoc. Prof.","CONTACT","+905053840429","esrauyarturkyilmaz@yahoo.com",[83],{"facility":84,"status":48,"city":85,"state":85,"zip":48,"country":86,"countryCode":48,"cosmosGeoPoint":87,"geoPoint":92,"contacts":93},"Ankara Bilkent City Hospital","Ankara","Turkey (Türkiye)",{"type":88,"coordinates":89},"Point",[90,91],32.85427,39.91987,{"lat":91,"lon":90},[94,96],{"name":74,"role":79,"phone":95,"phoneExt":48,"email":81},"+90505 384 04 29",{"name":97,"role":79,"phone":98,"phoneExt":48,"email":99},"Hilal KÜÇÜK, MD","+90 531 978 33 83","drhilalkucuk@gmail.com",{"type":75,"investigatorFullName":101,"investigatorTitle":102,"investigatorAffiliation":5,"oldNameTitle":48,"oldOrganization":48},"Esra Uyar Türkyılmaz","Assoc. Prof. (Doç. Dr.), Obstetric Anesthesiologist","100660127","effect-of-dural-puncture-epidural-analgesia-on-oxytocin-in-early-vs-late-labor-100660127",false,"NCT07873814","Effect of Dural Puncture Epidural Analgesia on Oxytocin in Early vs Late Labor","Comparison of Maternal Plasma Oxytocin Response to Dural Puncture Epidural Analgesia in Early (≤5cm) vs Late (≥6cm) Cervical Dilation Stages of Spontaneous Labor: A Prospective Comparative Study","DPEA-OXY","Inclusion Criteria:\n\n* Gestational age 37-41 weeks, singleton pregnancy, vertex presentation\n* Spontaneous onset of labor (not induced)\n* Request for neuraxial labor analgesia (DPEA)\n* Cervical dilation ≤5 cm (Early Group) or ≥ 6 cm (Late Group) at the time of DPEA\n* Age 18-40 years, ASA physical status II\n* Able to communicate in Turkish; written informed consent\n\nExclusion Criteria:\n\nCRITICAL EXCLUSION (methodological requirement):\n\n* Any administration of exogenous oxytocin (induction or augmentation) prior to T-0 blood sampling\n* Use of misoprostol, dinoprostone, or other labor-stimulating agents\n\nSTANDARD EXCLUSION:\n\n* Opioid use within the preceding 12 hours\n* Membrane rupture \\>2 hours before enrollment\n* Uterine hyperstimulation\n* History of lumbar spine surgery, coagulopathy (platelet count \\\u003C80,000\u002Fmm³)\n* Known allergy to local anesthetics or opioids\n* Preeclampsia, gestational hypertension, or insulin-dependent gestational diabetes\n* Suspected placenta previa\u002Fabruption, non-reassuring fetal status\n* Polyhydramnios or oligohydramnios\n* Technical failure of DPEA (\\>2 attempts, failed dural puncture confirmation)","FEMALE","18 Years","40 Years",{"count":115,"type":116},120,"ESTIMATED","OBSERVATIONAL","Oxytocin is a key hormone that regulates uterine contractions during labor. Dural Puncture Epidural Analgesia (DPEA) is a modern technique for labor pain relief that provides faster onset and more reliable analgesia than standard epidural.While it is known that neuraxial analgesia can suppress oxytocin levels, it is unclear whether this effect depends on the stage of labor at which analgesia is administered. This prospective comparative study will enroll 120 pregnant women in spontaneous labor who request DPEA, divided into two groups: Early group (cervical dilation≤5 cm, n=60) and Late group (cervical dilation≥6 cm , n=60). Both groups receive identical DPEA (a total volume of 15 mL containing 0.1% bupivacaine and 100 µg fentanyl is administered through the epidural catheter, following dural puncture with a 26G spinal needle without intrathecal drug injection). The primary outcome is the percentage change in plasma oxytocin from baseline (T-0, before analgesia) to T-Eff (30 minutes after onset of effective analgesia defined as VAS\\\u003C2). Patients who received any exogenous oxytocin (induction or augmentation) before T-0 are excluded to ensure that the measured oxytocin represents endogenous production. The study will contribute to understanding how the timing of neuraxial analgesia relative to labor progression affects the endogenous oxytocin system, with potential implications for optimal clinical timing of labor analgesia administration.",[120,121,122],"Labor Analgesia","Labor Pain","Oxytocin",[124,125,126,127,128],"dural puncture epidural","neuraxial analgesia","oxytocin","cervical dilatation","labor analgesia","NOT_YET_RECRUITING","2026-10-14",{"date":132,"type":133},"2026-10-19","ACTUAL",{"date":135,"type":116},"2026-11-01",{"date":137,"type":116},"2027-08-01",{"name":5,"class":6},1]