[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100662187":3},{"organization":4,"outcomesModule":7,"designInfo":41,"detailedDescription":48,"studyPopulation":16,"armGroups":49,"interventions":57,"overallOfficials":16,"centralContacts":67,"locations":78,"responsibleParty":92,"collaborators":16,"id":96,"slug":97,"hasResults":98,"nctId":99,"briefTitle":100,"officialTitle":101,"acronym":102,"eligibilityCriteria":103,"healthyVolunteers":98,"sex":104,"minAge":105,"maxAge":16,"enrollmentInfo":106,"targetDuration":16,"studyType":109,"phases":110,"briefSummary":111,"conditions":112,"keywords":117,"overallStatus":126,"whyStopped":16,"lastUpdateSubmitDate":127,"lastUpdatePostDateStruct":128,"startDateStruct":131,"completionDateStruct":133,"leadSponsor":135,"locationsCount":136},{"fullName":5,"class":6},"Marmara University","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":16},[9],{"measure":10,"description":11,"timeFrame":12},"Rate of false amplitude decrease greater than 50%","Proportion of evaluations in which the amplitude at vagal stimulation after resection (V2) is more than 50% lower than the amplitude at vagal stimulation before resection (V1), among nerves in which no true nerve injury is present. One nerve per patient is analyzed, on the first side evaluated, and the two electrode types are compared within the same nerve using the two-sided exact McNemar test. True nerve injury is determined by a combination of a standard loss-of-signal algorithm, intraoperative findings and, where indicated, postoperative laryngoscopy performed within 2 weeks after surgery.","Intraoperative recording (up to 4 hours), with true nerve injury status ascertained by postoperative laryngoscopy within 2 weeks after surgery",[14,18,21,24,27,29,32,36,39],{"measure":15,"description":16,"timeFrame":17},"Proportion of evaluations with a baseline amplitude of 500 microvolts or more at vagal stimulation before resection (V1)",null,"Intraoperative, before resection (up to 2 hours)",{"measure":19,"description":16,"timeFrame":20},"Proportion of evaluations in which the final amplitude is unchanged or higher than baseline","Intraoperative, up to 4 hours",{"measure":22,"description":23,"timeFrame":20},"Signal amplitude in microvolts at each stimulation step","Amplitude recorded at vagal stimulation before dissection (V1), recurrent laryngeal nerve stimulation after identification (R1), recurrent laryngeal nerve stimulation after completion of lobar dissection (R2) and vagal stimulation at the end of the procedure (V2).",{"measure":25,"description":26,"timeFrame":20},"Signal latency in milliseconds at each stimulation step","Latency recorded at vagal stimulation before dissection (V1), recurrent laryngeal nerve stimulation after identification (R1), recurrent laryngeal nerve stimulation after completion of lobar dissection (R2) and vagal stimulation at the end of the procedure (V2).",{"measure":28,"description":16,"timeFrame":17},"Rate of technical failure, defined as failure to obtain a baseline signal",{"measure":30,"description":16,"timeFrame":31},"Positive and negative predictive value of each electrode type for true nerve injury","From surgery to 3 months after surgery",{"measure":33,"description":34,"timeFrame":35},"Change in Turkish Voice Handicap Index-10 total score","The Turkish version of the Voice Handicap Index-10 (VHI-10) is a 10-item patient-reported questionnaire on voice-related handicap. Each item is scored from 0 to 4, giving a total score from 0 (best) to 40 (worst). Higher scores indicate greater voice handicap, so an increase from baseline is a worse outcome.","Baseline, 2 weeks and 3 months after surgery",{"measure":37,"description":38,"timeFrame":35},"Change in Turkish Eating Assessment Tool-10 total score","The Turkish version of the Eating Assessment Tool-10 (EAT-10) is a 10-item patient-reported questionnaire on swallowing difficulty. Each item is scored from 0 to 4, giving a total score from 0 (best) to 40 (worst). Higher scores indicate greater swallowing difficulty, so an increase from baseline is a worse outcome.",{"measure":40,"description":16,"timeFrame":31},"Incidence of adverse events attributed to electrode placement",{"allocation":42,"interventionModel":43,"interventionModelDescription":44,"primaryPurpose":45,"observationalModel":16,"timePerspective":16,"maskingInfo":46},"NA","SINGLE_GROUP","All participants receive both electrode types simultaneously during the same operation, so that each participant serves as their own control. There is no separate comparison group; the comparison is within-patient, between the two recording channels.","DIAGNOSTIC",{"masking":47,"maskingDescription":16,"whoMasked":16},"NONE","Patients scheduled for primary total thyroidectomy or hemithyroidectomy are enrolled consecutively at a single center. All operations are performed by experienced endocrine surgeons using a standardized capsular dissection technique. After induction, a neuromonitoring endotracheal tube with surface electrodes is positioned by the anesthetist. At the start of the operation, after the skin incision and exposure of the thyroid cartilage, paired needle electrodes are inserted into the anterior thyroid cartilage in the subperichondrial plane. Both electrode channels are connected to the same neuromonitoring system and record simultaneously throughout the procedure. Electromyographic responses are obtained according to the standard V1, R1, R2, V2 algorithm: vagal stimulation before dissection (V1), recurrent laryngeal nerve stimulation after identification (R1), recurrent laryngeal nerve stimulation after completion of lobar dissection (R2) and vagal stimulation at the end of the procedure (V2). Amplitude and latency are recorded from both channels at each step. Loss of signal is defined according to the International Neural Monitoring Study Group criteria. When loss of signal occurs, the standard troubleshooting algorithm is applied and the operative strategy is adjusted accordingly. True nerve injury is determined from the combination of the loss-of-signal algorithm, intraoperative findings and postoperative vocal cord examination within 2 weeks after surgery, which is performed in patients with voice symptoms and in all patients in whom loss of signal was recorded. Voice and swallowing are assessed with the Turkish versions of the Voice Handicap Index-10 and the Eating Assessment Tool-10 before surgery and at 2 weeks and 3 months after surgery. The primary analysis uses one nerve per patient, on the first side evaluated. The two electrode types are compared within the same nerve using the two-sided exact McNemar test.",[50],{"label":51,"type":52,"description":53,"interventionNames":54},"Simultaneous dual-electrode neuromonitoring","EXPERIMENTAL","All participants undergo thyroidectomy with simultaneous recording from an endotracheal tube surface electrode and transcartilage needle electrodes. Each participant serves as their own control.",[55,56],"Device: Transcartilage needle electrode recording","Device: Endotracheal tube surface electrode recording",[58,63],{"type":59,"name":60,"description":61,"armGroupLabels":62,"otherNames":16},"DEVICE","Transcartilage needle electrode recording","Paired needle electrodes are inserted into the anterior thyroid cartilage in the subperichondrial plane through the existing neck incision at the start of the operation, and removed at the end. Electromyographic responses to vagal and recurrent laryngeal nerve stimulation are recorded at vagal stimulation before dissection (V1), recurrent laryngeal nerve stimulation after identification (R1), recurrent laryngeal nerve stimulation after completion of lobar dissection (R2) and vagal stimulation at the end of the procedure (V2).",[51],{"type":59,"name":64,"description":65,"armGroupLabels":66,"otherNames":16},"Endotracheal tube surface electrode recording","A standard neuromonitoring endotracheal tube with surface electrodes is positioned at intubation. Electromyographic responses to vagal and recurrent laryngeal nerve stimulation are recorded at the same four stimulation steps, simultaneously with the needle electrode channel.",[51],[68,74],{"name":69,"role":70,"phone":71,"phoneExt":72,"email":73},"Muhammer Ergenç, MD","CONTACT","+902166254545","3629","muhammer.ergenc@marmara.edu.tr",{"name":75,"role":70,"phone":71,"phoneExt":76,"email":77},"Mustafa Baş, MD","7454","mustafa.bas@marmara.edu.tr",[79],{"facility":80,"status":16,"city":81,"state":16,"zip":82,"country":83,"countryCode":16,"cosmosGeoPoint":84,"geoPoint":89,"contacts":90},"Marmara University School of Medicine Hospital, Department of General Surgery","Istanbul","34854","Turkey (Türkiye)",{"type":85,"coordinates":86},"Point",[87,88],28.94966,41.01384,{"lat":88,"lon":87},[91],{"name":75,"role":70,"phone":71,"phoneExt":76,"email":77},{"type":93,"investigatorFullName":94,"investigatorTitle":95,"investigatorAffiliation":5,"oldNameTitle":16,"oldOrganization":16},"PRINCIPAL_INVESTIGATOR","Muhammer Ergenç","Associate Professor of General Surgery","100662187","endotracheal-tube-versus-transcartilage-needle-electrodes-for-nerve-monitoring-in-thyroid-surgery-100662187",false,"NCT07902349","Endotracheal Tube Versus Transcartilage Needle Electrodes for Nerve Monitoring in Thyroid Surgery","Comparison of Endotracheal Tube Surface Electrodes and Transcartilage Needle Electrodes for Intraoperative Neuromonitoring During Thyroidectomy: A Prospective Within-Patient Comparison","TRANSCOMP","Inclusion Criteria:\n\n* Age 18 years or older\n* Scheduled for primary total thyroidectomy or hemithyroidectomy\n* Normal vocal cord mobility on preoperative laryngoscopic examination\n* Able to read and complete the Voice Handicap Index-10 (VHI-10) and Eating Assessment Tool-10 (EAT-10) questionnaires\n* Written informed consent\n\nExclusion Criteria:\n\n* Preoperative vocal cord paralysis or paresis\n* Previous thyroid, parathyroid or neck surgery, including completion thyroidectomy\n* Previous radiotherapy to the neck\n* Advanced thyroid cancer with invasion of the trachea, esophagus or larynx\n* Anatomy preventing needle electrode placement, including severely calcified thyroid cartilage, previous laryngeal trauma or previous laryngeal surgery\n* Neuromuscular disease such as myasthenia gravis, or other neurological disease affecting nerve conduction\n* American Society of Anesthesiologists (ASA) physical status 4 or higher\n* Planned transoral or endoscopic approach\n* Pregnancy\n* Bleeding diathesis, or anticoagulant treatment that cannot be interrupted before surgery\n* Concurrent neck dissection planned with thyroidectomy\n* Expected inability to comply with the follow-up protocol","ALL","18 Years",{"count":107,"type":108},100,"ESTIMATED","INTERVENTIONAL",[42],"Intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroidectomy is most commonly performed with surface electrodes embedded in the endotracheal tube (ETT). ETT electrodes are prone to malposition, rotation and secretions, which can produce low signal amplitudes and false signal loss. Transcartilage needle electrodes (TCN), placed into the thyroid cartilage, have been reported to yield higher and more stable amplitudes. This single-center prospective study records ETT and TCN signals simultaneously in the same patient during thyroidectomy, so that each patient serves as their own control. The primary aim is to compare how often each electrode type shows a false amplitude decrease of more than 50% in nerves without true injury. Voice and swallowing outcomes are assessed before surgery and at 2 weeks and 3 months after surgery using the Turkish versions of the Voice Handicap Index-10 and the Eating Assessment Tool-10.",[113,114,115,116],"Thyroid Diseases","Recurrent Laryngeal Nerve Injury","Vocal Cord Paralysis","Thyroid Nodule",[118,119,120,121,122,123,124,125],"Intraoperative neuromonitoring","Recurrent laryngeal nerve","Thyroidectomy","Transcartilage electrode","Endotracheal tube electrode","Electromyography","Voice Handicap Index","Eating Assessment Tool","NOT_YET_RECRUITING","2026-10-28",{"date":129,"type":130},"2026-10-30","ACTUAL",{"date":132,"type":108},"2026-11-01",{"date":134,"type":108},"2027-09-30",{"name":5,"class":6},1]