[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100660424":3},{"organization":4,"outcomesModule":7,"designInfo":19,"detailedDescription":24,"studyPopulation":18,"armGroups":25,"interventions":38,"overallOfficials":47,"centralContacts":51,"locations":57,"responsibleParty":76,"collaborators":18,"id":78,"slug":79,"hasResults":80,"nctId":81,"briefTitle":82,"officialTitle":83,"acronym":84,"eligibilityCriteria":85,"healthyVolunteers":86,"sex":87,"minAge":88,"maxAge":18,"enrollmentInfo":89,"targetDuration":18,"studyType":92,"phases":93,"briefSummary":95,"conditions":96,"keywords":98,"overallStatus":102,"whyStopped":18,"lastUpdateSubmitDate":103,"lastUpdatePostDateStruct":104,"startDateStruct":107,"completionDateStruct":109,"leadSponsor":111,"locationsCount":112},{"fullName":5,"class":6},"Iuliu Hatieganu University of Medicine and Pharmacy","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":18},[9],{"measure":10,"description":11,"timeFrame":12},"Mean paired difference in systolic blood pressure","Primary outcome: Mean paired difference in systolic blood pressure between Fowler and seated positions.","25-30 minutes",[14],{"measure":15,"description":16,"timeFrame":17},"BP equivalence in specific populations","Identification of patient groups\u002F populations where the seated vs fowler would be considereed as equal","20-30 minutes",null,{"allocation":20,"interventionModel":21,"interventionModelDescription":18,"primaryPurpose":6,"observationalModel":18,"timePerspective":18,"maskingInfo":22},"RANDOMIZED","CROSSOVER",{"masking":23,"maskingDescription":18,"whoMasked":18},"NONE","Background and Rationale Blood pressure (BP) measurement is a cornerstone of cardiovascular assessment. Standard guidelines recommend seated BP measurements; however, in routine clinical practice, measurements are frequently obtained in alternative positions such as the Fowler position. This study aims to determine whether SBP measurements obtained in the Fowler position are clinically equivalent to those obtained in the seated position.\n\nObjectives The primary objective is to determine whether SBP measured in the Fowler position is equivalent to SBP measured in the seated position within a predefined clinical equivalence margin of ±5 mmHg.\n\nHypothesis Null hypothesis: The mean paired difference in SBP between Fowler and seated positions is outside the equivalence margin of ±5 mmHg.\n\nAlternative hypothesis: The mean paired difference in SBP between Fowler and seated positions lies within the equivalence margin of ±5 mmHg.\n\nStudy Design This is a prospective, randomized, paired equivalence trial. Each participant will undergo SBP measurement in both seated and Fowler positions, with the order of positions randomized.\n\nSetting Outpatient cardiology clinic. Blood Pressure Measurement Protocol Blood pressure will be measured using a validated automated OMRON device. For each position, three consecutive (1 minute apart) SBP measurements will be obtained and averaged. A rest period of 5 minutes will be observed after changing position before measurements, with a 5-minute rest period before the first BP measurement. The same arm and appropriately sized cuff will be used for all measurements.\n\nSeated position\n\n* Back supported\n* Feet flat on the floor\n* Legs uncrossed\n* Arm supported at mid-sternal (right atrial) level Fowler position\n* Semi-recumbent position with trunk elevated at 30° measured using an inclinometer\n* Knees extended\n* Back supported\n\nRandomization Participants will be randomized 1:1 to one of two measurement sequences: (1) seated first followed by Fowler, or (2) Fowler first followed by seated. The method used is random block generation, to account for the relatively small size of the study population.\n\nOutcome Measure Primary outcome: Mean paired difference in systolic blood pressure between Fowler and seated positions.\n\nSample Size Calculation Assuming a standard deviation of paired differences of 9 mmHg, an equivalence margin of ±5 mmHg, a two-sided alpha of 0.01, and 95% power, a minimum of 120 participants is required. This will yield 240 observations between the two positions.\n\nStatistical Analysis Analyses will be performed according to a per-protocol principle, as recommended for equivalence trials.\n\nThe mean paired difference (Fowler - seated, seated - Fowler) will be calculated for each participant.\n\nEquivalence will be assessed using the TOST procedure. A 99% confidence interval (CI) for the mean paired SBP difference will be constructed. Equivalence will be concluded if the entire CI lies within the predefined equivalence margin of ±5 mmHg.\n\nNormality of paired differences will be evaluated using the Shapiro-Wilk test. If violated, bootstrap confidence intervals (10,000 resamples) will be used.\n\nAll tests will be two-sided with significance level α = 0.01. Ethical Considerations The study will be conducted in accordance with the Declaration of Helsinki. All participants will provide written informed consent prior to participation.\n\nData Management Data will be collected anonymously and stored securely. Only study investigators will have access to the final dataset.",[26,32],{"label":27,"type":28,"description":29,"interventionNames":30},"Seated BP","ACTIVE_COMPARATOR","standardised BP measurement",[31],"Other: Standard BP measurement",{"label":33,"type":34,"description":35,"interventionNames":36},"Fowler BP","EXPERIMENTAL","The same protocol as per standard measurement, with the patient in the semi-recumbent position (Fowler position), at a 30 degree angle of the head of the bed",[37],"Other: blood pressure measurement in the semi-recumbent position",[39,43],{"type":6,"name":40,"description":41,"armGroupLabels":42,"otherNames":18},"blood pressure measurement in the semi-recumbent position","Blood pressure measurement , with the investigational variable being the position of the body of the patient",[33],{"type":6,"name":44,"description":45,"armGroupLabels":46,"otherNames":18},"Standard BP measurement","Standardized BP measurement, in the seated, back-supported position",[27],[48],{"name":49,"affiliation":5,"role":50},"Mihai Lupu, MD, PhD, Assistant Professor","STUDY_CHAIR",[52],{"name":49,"role":53,"phone":54,"phoneExt":55,"email":56},"CONTACT","România","+40755022572","lupu.mihai@umfcluj.ro",[58,71],{"facility":59,"status":18,"city":60,"state":61,"zip":62,"country":63,"countryCode":64,"cosmosGeoPoint":65,"geoPoint":70,"contacts":18},"Centrul Medical Transilvania","Cluj-Napoca","Cluj","40034","Romania","RO",{"type":66,"coordinates":67},"Point",[68,69],23.6,46.76667,{"lat":69,"lon":68},{"facility":72,"status":18,"city":60,"state":61,"zip":62,"country":63,"countryCode":64,"cosmosGeoPoint":73,"geoPoint":75,"contacts":18},"Spitalul Clinic Judetean de Urgenta Cluj",{"type":66,"coordinates":74},[68,69],{"lat":69,"lon":68},{"type":77,"investigatorFullName":18,"investigatorTitle":18,"investigatorAffiliation":18,"oldNameTitle":18,"oldOrganization":18},"SPONSOR","100660424","equivalence-of-systolic-blood-pressure-measurements-between-fowler-and-seated-positions-100660424",false,"NCT07878858","Equivalence of Systolic Blood Pressure Measurements Between Fowler and Seated Positions","Equivalence of Systolic Blood Pressure Measurements Between Fowler and Seated Positions: A Randomized Paired Equivalence Trial","POSE-SBP","Inclusion Criteria:\n\n* Adults aged ≥18 years\n* Arm circumference 22-42 cm\n* Ability to provide informed consent\n\nExclusion Criteria:\n\n* Inability to maintain required positions\n* Pregnancy\n* Any condition interfering with accurate BP measurement (i.e., atrial fibrillation)",true,"ALL","18 Years",{"count":90,"type":91},200,"ESTIMATED","INTERVENTIONAL",[94],"NA","Blood pressure is an important part of checking heart health. Blood pressure is usually measured while sitting, but in everyday medical care it is sometimes measured in other positions, such as the Fowler position, where the upper body is raised. This study will compare blood pressure measured while sitting with blood pressure measured in the Fowler position to see whether the results are similar enough to be considered equivalent. Adults aged 18 or older who can give informed consent and have an arm circumference of 22-42 cm may take part. Each participant will have their blood pressure measured in both positions, with the order chosen randomly. People who cannot maintain the required positions or whose condition could affect the accuracy of the blood pressure measurement will not take part.",[97],"Blood Pressure Measurement",[99,100,101],"blood pressure","methodology","equivalence","NOT_YET_RECRUITING","2026-10-27",{"date":105,"type":106},"2026-10-29","ACTUAL",{"date":108,"type":91},"2026-10-20",{"date":110,"type":91},"2026-12-20",{"name":5,"class":6},2]