[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100660469":3},{"organization":4,"outcomesModule":7,"designInfo":27,"detailedDescription":33,"studyPopulation":26,"armGroups":34,"interventions":45,"overallOfficials":26,"centralContacts":26,"locations":50,"responsibleParty":98,"collaborators":26,"id":100,"slug":101,"hasResults":102,"nctId":103,"briefTitle":104,"officialTitle":105,"acronym":106,"eligibilityCriteria":107,"healthyVolunteers":102,"sex":108,"minAge":109,"maxAge":26,"enrollmentInfo":110,"targetDuration":26,"studyType":113,"phases":114,"briefSummary":116,"conditions":117,"keywords":119,"overallStatus":53,"whyStopped":26,"lastUpdateSubmitDate":122,"lastUpdatePostDateStruct":123,"startDateStruct":126,"completionDateStruct":128,"leadSponsor":130,"locationsCount":131},{"fullName":5,"class":6},"Morrow Eyewear","INDUSTRY",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":26},[9],{"measure":10,"description":11,"timeFrame":12},"Reduction in head gain","Reduction in head gain: defined as the ratio of head yaw angle to total gaze angle, assessed during optotype reading across varying horizontal and vertical gaze angles, to evaluate the superiority of the Morrow eProgressive over the control Progressive Addition Lens (PAL) in facilitating more efficient gaze strategies and dynamic visual performance.","Comparing the 3-week wearing period at visit 4, with the 3-week wearing period at visit 3",[14,17,20,23],{"measure":15,"description":16,"timeFrame":12},"Mean stair descent time","Stair Descent Performance: The change in mean stair descent time (measured in seconds) during a standardized stair descent test, compared between the Morrow eProgressive and the control Progressive Addition Lens (PAL).",{"measure":18,"description":19,"timeFrame":12},"Mean cadence variability","Stair Descent Performance: The change in mean cadence variability (gait stability metric) during a standardized stair descent test, compared between the Morrow eProgressive and the control Progressive Addition Lens (PAL).",{"measure":21,"description":22,"timeFrame":12},"Mean NAVQ-P score","Patient-Reported Visual Quality: change in the mean Near Visual Acuity Questionnaire Presbyopia (NAVQ-P) score, compared between the Morrow eProgressive and the control Progressive Addition Lens (PAL), reported on a scale from 0 to 3 with lower scores having a better outcome.",{"measure":24,"description":25,"timeFrame":12},"Subjective Lens Preference for Vision","Subjective Lense Preference for Vision: the proportion of participants expressing an overall preference in terms of better vision for the Morrow eProgressive lens compared to the control Progressive Addition Lens (PAL), as evaluated by a post-wear Lens Preference Questionnaire, reported on a scale from 1 to 10 with higher scores having a better outcome.",null,{"allocation":28,"interventionModel":29,"interventionModelDescription":26,"primaryPurpose":30,"observationalModel":26,"timePerspective":26,"maskingInfo":31},"RANDOMIZED","CROSSOVER","SUPPORTIVE_CARE",{"masking":32,"maskingDescription":26,"whoMasked":26},"NONE","Traditional PALs are characterized by fixed optical corridors bordered by lateral astigmatism. This spatial restriction imposes a significant physiological and biomechanical burden on the wearer during dynamic visual tasks. When executing lateral gaze shifts, such as shifting from the end of a line of text to the beginning of the next during reading, or scanning the ground during locomotion, wearers must either tolerate peripheral blur or employ compensatory head movements. The Morrow eProgressive utilizes active electronic focal adaptation to provide an expanded, uncompromised visual field, theoretically mitigating these optical limitations and restoring natural oculomotor patterns.\n\nA key challenge in presbyopic clinical trials is the high degree of inter-individual variability. Factors such as individual neuro-visual adaptation speed and prior spectacle history vary widely between patients. To eliminate these significant confounding variables, this investigation utilizes a randomized, open-label, crossover design. By allowing each participant to serve as their own internal control across balanced 3-week wear periods, the study isolates the direct optical impact of the lens technology from confounding patient specific characteristics, vastly increasing the statistical validity of the intra-subject comparisons.\n\nThis study optimizes clinical efficiency by employing a dual-layered endpoint strategy:\n\n* Objective dynamic visual performance (Primary): Eye-tracking parameter, specifically head gain, serve as objective indicator of visual field performance.\n* Functional and Subjective Validation (Secondary): To ensure these micro-physiological improvements translate to real-world patient utility, objective metrics are paired with the validated Near Visual Acuity Questionnaire Presbyopia (NAVQ-P), a dedicated Subjective Lens Preference Questionnaire, and physical performance tasks via a standardized Stair Descent Test.",[35,41],{"label":36,"type":37,"description":38,"interventionNames":39},"Morrow eProgressive","EXPERIMENTAL","3 weeks wearing of study device instead of their current wearing solution",[40],"Procedure: 3 weeks wearing of study device instead of their current wearing solution",{"label":42,"type":43,"description":38,"interventionNames":44},"Traditional PAL","ACTIVE_COMPARATOR",[40],[46],{"type":47,"name":38,"description":48,"armGroupLabels":49,"otherNames":26},"PROCEDURE","Instead of wearing their current solution for presbyopia, all participants can solely wear allocated spectacles during the duration of the trial for all day to day activities.",[36,42],[51,69,83],{"facility":52,"status":53,"city":54,"state":26,"zip":26,"country":55,"countryCode":56,"cosmosGeoPoint":57,"geoPoint":62,"contacts":63},"University Hospital Antwerp","RECRUITING","Antwerp","Belgium","BE",{"type":58,"coordinates":59},"Point",[60,61],4.40026,51.22047,{"lat":61,"lon":60},[64],{"name":65,"role":66,"phone":67,"phoneExt":26,"email":68},"Carina Koppen","CONTACT","+3238213372","secretariaat.oogheelkunde@uza.be",{"facility":70,"status":71,"city":72,"state":26,"zip":26,"country":55,"countryCode":56,"cosmosGeoPoint":73,"geoPoint":77,"contacts":78},"Meclinas","NOT_YET_RECRUITING","Mechelen",{"type":58,"coordinates":74},[75,76],4.47762,51.02574,{"lat":76,"lon":75},[79],{"name":80,"role":66,"phone":81,"phoneExt":26,"email":82},"Lisa Billast","+3215792797","info@meclinas.com",{"facility":84,"status":71,"city":85,"state":26,"zip":26,"country":86,"countryCode":87,"cosmosGeoPoint":88,"geoPoint":92,"contacts":93},"Research Centre in Optics & Optometry (COMiB), University of Milano Bicocca","Milan","Italy","IT",{"type":58,"coordinates":89},[90,91],9.18951,45.46427,{"lat":91,"lon":90},[94],{"name":95,"role":66,"phone":96,"phoneExt":26,"email":97},"Fabrizio Zeri","+39264485054","fabrizio.zeri@unimib.it",{"type":99,"investigatorFullName":26,"investigatorTitle":26,"investigatorAffiliation":26,"oldNameTitle":26,"oldOrganization":26},"SPONSOR","100660469","evaluation-of-functional-superiority-of-the-morrow-eprogressive-100660469",false,"NCT07878416","Evaluation of Functional Superiority of the Morrow eProgressive","Evaluation of Functional Superiority of the Morrow eProgressive : A Comparative Study of Visual and Physical Comfort During Dynamic Activity","EPACT","Inclusion Criteria:\n\n* Adults aged 45 or older, who are presbyopic in both eyes, with an inclusion criterium of minimum + 1.75 ADDition.\n* Suitable candidate for Morrow glasses\n* Willing and able to adhere to the study protocol and study procedures, and provide written consent prior to enrollment\n* Willing and able to strictly adhere to the 2 x 3-week spectacle-wearing schedule for all standard day-to-day activities, including a commitment to exclusive progressive wear of the assigned study spectacles (traditional PAL or Morrow eProgressive) throughout each respective study phase (temporary exceptions for sports or specific occasions are permitted using single-vision solutions only).\n* Current vision solution satisfaction below 8\u002F10, as assessed by the study specific satisfaction questionnaire.\n\nExclusion Criteria:\n\n* Individuals who do not yet require a reading addition for near tasks.\n* Distant BCVA worse than 20\u002F25 (Snellen) or \\>0.1 LogMar\n* Previous laser treatment for refractive correction.\n* Any previous refraction and\u002For intra-ocular surgery.\n* Any known systemic diseases affecting vision (e.g. diabetes, uncontrolled or unmedicated hypertension, autoimmune disease, inflammatory disease … ), at the discretion of the investigator\n* Associated strabismus (eyes not properly aligned)\n* Associated amblyopia (lazy eye)\n* Currently undergoing orthoptics therapy (exercises or treatments to fix eye movement problems or double vision)\n* Associated anisometropia \\> 1.5 diopters","ALL","45 Years",{"count":111,"type":112},50,"ESTIMATED","INTERVENTIONAL",[115],"NA","Presbyopia is a common age-related condition where the eye loses its ability to focus on nearby objects, typically from around age 45.\n\nThe standard correction is progressive addition lenses (PALs), but these have limitations: narrow viewing zones, peripheral distortion, and the need for unnatural head movements, which can affect comfort and safety.\n\nMorrow has developed an electronically adjustable progressive lens (Morrow eProgressive) that dynamically adapts its optical zones.\n\nThis CE-marked device is already commercially available. This study compares its functional performance against standard PALs.\n\nApproximately 50 adults (≥45 years) will participate at three sites (Belgium and Italy). Each participant wears both glasses types for three weeks each, in random order.\n\nResearchers will measure head and eye movements during reading tasks, stair descent performance, and visual comfort via a questionnaire. Participants will also indicate their overall lens preference.",[118],"Presbyopia",[120,121],"post market","presbyopia","2026-10-12",{"date":124,"type":125},"2026-10-16","ACTUAL",{"date":127,"type":125},"2026-09-24",{"date":129,"type":112},"2027-02-28",{"name":5,"class":6},3]