[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100663406":3},{"organization":4,"outcomesModule":7,"designInfo":54,"detailedDescription":57,"studyPopulation":58,"armGroups":59,"interventions":65,"overallOfficials":11,"centralContacts":71,"locations":77,"responsibleParty":129,"collaborators":133,"id":137,"slug":138,"hasResults":139,"nctId":140,"briefTitle":141,"officialTitle":142,"acronym":11,"eligibilityCriteria":143,"healthyVolunteers":144,"sex":145,"minAge":146,"maxAge":147,"enrollmentInfo":148,"targetDuration":11,"studyType":151,"phases":11,"briefSummary":152,"conditions":153,"keywords":11,"overallStatus":80,"whyStopped":11,"lastUpdateSubmitDate":155,"lastUpdatePostDateStruct":156,"startDateStruct":159,"completionDateStruct":161,"leadSponsor":163,"locationsCount":164},{"fullName":5,"class":6},"Huazhong University of Science and Technology","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":11},[9],{"measure":10,"description":11,"timeFrame":12},"Agreement Between Expert BI-RADS Classifications Based on Robotic and Handheld Breast Ultrasound Images",null,"6 weeks after completion of image collection for all participants",[14,17,20,22,24,26,28,30,32,35,38,40,42,44,46,48,50,52],{"measure":15,"description":16,"timeFrame":12},"Proportion of Examinations With Complete Breast Coverage Assessed by Expert Review of Ultrasound Recordings","Breast scanning completeness will be assessed through expert review of the complete ultrasound recordings obtained using robotic and handheld ultrasound. Each examination will be classified as complete or incomplete (Yes\u002FNo) according to whether the predefined breast scanning regions are adequately covered. The outcome will be reported as the percentage of complete examinations for each modality.",{"measure":18,"description":19,"timeFrame":12},"Overall Breast Ultrasound Image Quality Assessed Using a 5-Point Expert Rating Scale","Overall image quality will be evaluated by experienced breast ultrasound experts using a 5-point ordinal rating scale (1 = poorest quality; 5 = best quality) based on the complete ultrasound recordings acquired using each modality.",{"measure":21,"description":11,"timeFrame":12},"Lesion-Level Detection Sensitivity",{"measure":23,"description":11,"timeFrame":12},"Mean Number of False-Positive Lesion Detections per Breast Ultrasound Examination",{"measure":25,"description":11,"timeFrame":12},"Lesion Detection Precision",{"measure":27,"description":11,"timeFrame":12},"Proportion of Breast Lesions With Accurate Localization Based on Expert Reference Assessment",{"measure":29,"description":11,"timeFrame":12},"Agreement in Lesion Diameter Measurements",{"measure":31,"description":11,"timeFrame":12},"Agreement Between Robotic and Handheld Ultrasound in Sonographic Features (Shape, Orientation, Margin, Echogenicity, and Posterior Acoustic Features) of Breast Lesions",{"measure":33,"description":34,"timeFrame":12},"Patient-Reported Overall Satisfaction Score Using a 5-Point Questionnaire","Responses will be coded on a 5-point ordinal scale: 1 = very dissatisfied, 2 = dissatisfied, 3 = neutral, 4 = satisfied, and 5 = very satisfied. Higher scores indicate greater satisfaction.",{"measure":36,"description":37,"timeFrame":12},"Patient-Reported Pain Score Assessed Using a Study-Specific 5-Point Scale","Each item will be coded on a 5-point ordinal scale, ranging from 1 (none) to 5 (very pronounced). Higher scores indicate greater perceived pressure, pain, or anxiety.",{"measure":39,"description":37,"timeFrame":12},"Patient-Reported Anxiety Score Assessed Using a Study-Specific 5-Point Scale",{"measure":41,"description":37,"timeFrame":12},"Patient-Reported Probe Pressure Score Assessed Using a Study-Specific 5-Point Scale",{"measure":43,"description":11,"timeFrame":12},"Patient-Level Sensitivity for Breast Cancer Detection",{"measure":45,"description":11,"timeFrame":12},"Patient-Level Specificity for Breast Cancer Detection",{"measure":47,"description":11,"timeFrame":12},"Area Under the Receiver Operating Characteristic Curve (AUC) for Patient-Level Breast Cancer Detection",{"measure":49,"description":11,"timeFrame":12},"Change in Patient-Level Sensitivity With Versus Without AI Assistance (Percentage Points)",{"measure":51,"description":11,"timeFrame":12},"Change in Patient-Level Specificity With Versus Without AI Assistance (Percentage Points)",{"measure":53,"description":11,"timeFrame":12},"Change in Area Under the Receiver Operating Characteristic Curve (AUC) With Versus Without AI Assistance",{"allocation":11,"interventionModel":11,"interventionModelDescription":11,"primaryPurpose":11,"observationalModel":55,"timePerspective":56,"maskingInfo":11},"COHORT","PROSPECTIVE","This is a prospective, multicenter, non-randomized, intraindividual paired clinical study. All eligible participants will undergo both autonomous breast ultrasound scanning using a dual-arm robotic ultrasound system and conventional handheld ultrasound examinations, with complete ultrasound images and videos retained for both examinations. Two senior ultrasound experts will independently review images from both modalities in a blinded manner, assessing lesion detection, localization, long and short diameters, sonographic features, and Breast Imaging Reporting and Data System (BI-RADS) categories. Disagreements will be resolved by a third expert.\n\nThe primary outcome is the agreement between expert BI-RADS assessments based on robotic ultrasound images and those based on conventional handheld ultrasound images. Secondary outcomes include imaging completeness and quality, lesion detection and localization, agreement in lesion size measurements, and patient-reported examination experiences. Additionally, the study will explore the patient-level diagnostic sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of both examination methods for breast cancer detection, as well as the impact of the robotic ultrasound AI-assisted diagnostic system on physicians' diagnostic performance.","Participants will be recruited from the breast ultrasound outpatient clinics of three participating hospitals in Hubei Province, China. The study population will consist of adults aged 18-80 years with no history of breast cancer who voluntarily participate in breast ultrasound screening. All eligible participants will undergo conventional handheld breast ultrasound followed by autonomous dual-arm robotic breast ultrasound.",[60],{"label":61,"type":11,"description":62,"interventionNames":63},"Breast Ultrasound Screening Cohort","Eligible participants will undergo conventional handheld breast ultrasound followed by autonomous dual-arm robotic breast ultrasound.",[64],"Diagnostic Test: Autonomous Dual-Arm Robotic Breast Ultrasound",[66],{"type":67,"name":68,"description":69,"armGroupLabels":70,"otherNames":11},"DIAGNOSTIC_TEST","Autonomous Dual-Arm Robotic Breast Ultrasound","Participants will undergo autonomous dual-arm robotic breast ultrasound after conventional handheld ultrasound. The system will autonomously perform breast scanning and acquire ultrasound images for subsequent evaluation of imaging and diagnostic performance. The robotic ultrasound results will not be used to guide clinical management.",[61],[72],{"name":73,"role":74,"phone":75,"phoneExt":11,"email":76},"Xiaoxv Yin","CONTACT","+8613871187781","yxx@hust.edu.cn",[78,96,109,118],{"facility":79,"status":80,"city":81,"state":82,"zip":83,"country":84,"countryCode":85,"cosmosGeoPoint":86,"geoPoint":91,"contacts":92},"Taihe Hospital of Shiyan City","RECRUITING","Shiyan","Hubei","442000","China","CN",{"type":87,"coordinates":88},"Point",[89,90],110.77806,32.6475,{"lat":90,"lon":89},[93],{"name":94,"role":74,"phone":95,"phoneExt":11,"email":76},"Xiaoxv Yin, Doctor","86+13871187781",{"facility":97,"status":98,"city":99,"state":82,"zip":100,"country":84,"countryCode":85,"cosmosGeoPoint":101,"geoPoint":105,"contacts":106},"Wuhan Children's Hospital","NOT_YET_RECRUITING","Wuhan","430016",{"type":87,"coordinates":102},[103,104],114.26667,30.58333,{"lat":104,"lon":103},[107],{"name":73,"role":74,"phone":108,"phoneExt":11,"email":76},"13871187781",{"facility":110,"status":80,"city":99,"state":82,"zip":111,"country":84,"countryCode":85,"cosmosGeoPoint":112,"geoPoint":114,"contacts":115},"Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology (Optical Valley Branch)","430030",{"type":87,"coordinates":113},[103,104],{"lat":104,"lon":103},[116],{"name":73,"role":74,"phone":117,"phoneExt":11,"email":76},"+86 13871187781",{"facility":119,"status":80,"city":120,"state":82,"zip":121,"country":84,"countryCode":85,"cosmosGeoPoint":122,"geoPoint":126,"contacts":127},"Xiantao First People's Hospital","Xiantao","433000",{"type":87,"coordinates":123},[124,125],113.44294,30.3708,{"lat":125,"lon":124},[128],{"name":73,"role":74,"phone":117,"phoneExt":11,"email":76},{"type":130,"investigatorFullName":131,"investigatorTitle":132,"investigatorAffiliation":5,"oldNameTitle":11,"oldOrganization":11},"PRINCIPAL_INVESTIGATOR","Xiaoxv Yin, PhD","Professor",[134],{"name":135,"class":136},"Wuhan Cobot Technology Co., Ltd.","UNKNOWN","100663406","evaluation-of-scanning-and-diagnostic-performance-of-an-autonomous-dual-arm-breast-ultrasound-robot-100663406",false,"NCT07915050","Evaluation of Scanning and Diagnostic Performance of an Autonomous Dual-Arm Breast Ultrasound Robot","Evaluation of Scanning and Diagnostic Performance of an Autonomous Dual-Arm Breast Ultrasound Robot: A Prospective, Multicenter Study","Inclusion Criteria:\n\n1. Aged 18-80 years.\n2. No history of breast cancer.\n3. Willing to voluntarily participate in breast screening.\n\nExclusion Criteria:\n\n1. History of breast resection surgery.\n2. Pregnant or breastfeeding women.\n3. Presence of prosthetic implants.\n4. Women with an allergy to ultrasound coupling gel.",true,"FEMALE","18 Years","80 Years",{"count":149,"type":150},885,"ESTIMATED","OBSERVATIONAL","This prospective, multicenter, intraindividual paired study aims to evaluate the autonomous scanning performance of a dual-arm robotic breast ultrasound system and the diagnostic performance of the images it acquires, in comparison with conventional handheld ultrasound. The study primarily focuses on the agreement between diagnostic assessments based on images obtained using the two examination methods, while also evaluating image quality, lesion detection, and measurement performance. The robotic ultrasound findings will be collected for research purposes only and will not be used to guide clinical management; all clinical decisions will be based on routine clinical assessment.",[154],"Breast Diseases","2026-11-08",{"date":157,"type":158},"2026-11-12","ACTUAL",{"date":160,"type":158},"2026-06-01",{"date":162,"type":150},"2028-06-30",{"name":5,"class":6},4]