[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100665574":3},{"organization":4,"outcomesModule":7,"designInfo":14,"detailedDescription":20,"studyPopulation":13,"armGroups":21,"interventions":31,"overallOfficials":13,"centralContacts":36,"locations":42,"responsibleParty":61,"collaborators":13,"id":65,"slug":66,"hasResults":67,"nctId":68,"briefTitle":69,"officialTitle":70,"acronym":13,"eligibilityCriteria":71,"healthyVolunteers":67,"sex":72,"minAge":73,"maxAge":13,"enrollmentInfo":74,"targetDuration":13,"studyType":77,"phases":78,"briefSummary":80,"conditions":81,"keywords":83,"overallStatus":45,"whyStopped":13,"lastUpdateSubmitDate":89,"lastUpdatePostDateStruct":90,"startDateStruct":93,"completionDateStruct":95,"leadSponsor":97,"locationsCount":98},{"fullName":5,"class":6},"Azienda Sanitaria Universitaria Integrata del Trentino","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":13},[9],{"measure":10,"description":11,"timeFrame":12},"Temperature drop","Measure the real temperature drop from the end of the heated respiratory tube and the tracheal carina in the patient with mechanical invasive ventilation and active humidification.","50 patients or 1 year",null,{"allocation":15,"interventionModel":16,"interventionModelDescription":13,"primaryPurpose":17,"observationalModel":13,"timePerspective":13,"maskingInfo":18},"RANDOMIZED","CROSSOVER","TREATMENT",{"masking":19,"maskingDescription":13,"whoMasked":13},"NONE","The study protocol involves measuring, in all patients meeting the inclusion criteria, both the temperature at the end of the heated ventilator circuit (\"Tpatient\") and the air temperature at the level of the tracheal carina.\n\nTpatient will be obtained by directly reading the value displayed on the humidifier. Tracheal air temperature will instead be measured by inserting a sterile temperature probe into the endotracheal tube.\n\nThe temperature probe used for this purpose will be the standard temperature measurement probe compatible with the GE CARESCAPE ONE® multiparameter monitor, currently available in the Intensive Care Unit 1 - Santa Chiara Hospital, Trento. The probe will be inserted into the endotracheal tube using a sterile technique. Before use, the reusable probe will undergo the sterilization process established by the APSS Central Sterilization Department.\n\nFor the purposes of this study, it is particularly important that the probe protrudes no more than 1 cm beyond the tip of the endotracheal tube, thereby avoiding contact with the tracheobronchial mucosa and minimizing the risk of pressure-related injuries. This positioning also ensures that the measurement reflects the intended parameter, namely air temperature. This condition will be achieved using the graduated scale on the temperature probe, which will allow the correct insertion depth to be determined.\n\nThe temperature measured by the probe will be displayed on the multiparameter monitor in the ICU through a dedicated electrical connection cable.\n\nThe humidifier used in the study will be the device already available in the Intensive Care Unit 1 - Santa Chiara Hospital, Trento, namely the Dräger Aquapor H300®. The humidifier will be operated in FREE mode, allowing the investigators to freely adjust the temperatures according to the settings specified in the study protocol.\n\nFor each enrolled patient, two series of measurements will be performed using two different humidification settings.\n\nThe first measurement series will be performed with Tpatient set at 37°C and a temperature gradient of -2°C (Tpatient 37°C - Tchamber 35°C). The second measurement series will be performed with Tpatient set at 40°C and a temperature gradient of -3°C (Tpatient 40°C - Tchamber 37°C).\n\nThe order in which the first and second measurement series are performed will be randomly assigned using an online randomization website.\n\nTo ensure that the humidifier reaches the selected temperature settings, each temperature configuration will be maintained for at least 15 minutes before measurements are recorded.\n\nAfter this 15-minute stabilization period, the Tpatient value displayed on the humidifier and the tracheal carina temperature displayed on the multiparameter monitor will be recorded in the study data collection form.\n\nFor each measurement, the following additional variables will also be recorded: patient's core body temperature, type of endotracheal tube, tube size, endotracheal tube insertion depth, volume of non-heated connectors, presence of mainstream ETCO₂ monitoring, type of ventilation, minute ventilation at the time of measurement, and ambient temperature.\n\nAfter the 30-minute period required to complete both measurement series (15 minutes at 37°C and 15 minutes at 40°C), the temperature probe will be removed from the endotracheal tube.",[22,28],{"label":23,"type":24,"description":25,"interventionNames":26},"Temperature drop 37°C","EXPERIMENTAL","Measure of the temperarure drop in two different humidification setting: 37°C - 40°C",[27],"Other: temperature drop",{"label":29,"type":24,"description":13,"interventionNames":30},"Temperature drop 40°C",[27],[32],{"type":6,"name":33,"description":34,"armGroupLabels":35,"otherNames":13},"temperature drop","Evaluation of the temperature drop from the end of the heated ventilatory tube to the tracheal carina",[23,29],[37],{"name":38,"role":39,"phone":40,"phoneExt":13,"email":41},"Riccardo Re, nurse","CONTACT","+393332298618","riccardo.re@asuit.tn.it",[43],{"facility":44,"status":45,"city":46,"state":47,"zip":48,"country":47,"countryCode":49,"cosmosGeoPoint":50,"geoPoint":55,"contacts":56},"Santa Chiara Hospital of Trento - ASUIT","RECRUITING","Trento","Italy","38100","IT",{"type":51,"coordinates":52},"Point",[53,54],11.12108,46.06787,{"lat":54,"lon":53},[57],{"name":58,"role":39,"phone":59,"phoneExt":13,"email":60},"Giacomo Bellani","+390461903972","giacomo.bellani@asuit.tn.it",{"type":62,"investigatorFullName":63,"investigatorTitle":64,"investigatorAffiliation":5,"oldNameTitle":13,"oldOrganization":13},"PRINCIPAL_INVESTIGATOR","Riccardo Re","Nurse","100665574","evaluation-of-the-temperature-difference-of-medical-gases-between-the-heated-inspiratory-limb-and-the-tracheal-carina-in-patients-undergoing-invasive-mechanical-ventilation-with-active-humidification-a-crossover-clinical-study-100665574",false,"NCT07946003","Evaluation of the Temperature Difference of Medical Gases Between the Heated Inspiratory Limb and the Tracheal Carina in Patients Undergoing Invasive Mechanical Ventilation With Active Humidification","Evaluation of the Temperature Difference of Medical Gases Between the Heated Inspiratory Limb and the Tracheal Carina in Patients Undergoing Invasive Mechanical Ventilation With Active Humidification: A Crossover Clinical Study","Inclusion Criteria:\n\n* Adult patients\n* Invasive mechanical ventilation\n* Active humidification\n* Invasive body temperature monitoring in place.\n\nExclusion Criteria:\n\n* Tubes smaller than size 7\n* Double-lumen tubes","ALL","18 Years",{"count":75,"type":76},50,"ESTIMATED","INTERVENTIONAL",[79],"NA","The aim of this study is to assess the actual temperature drop of medical gases from the distal end of the heated ventilator circuit to the tracheal carina during invasive mechanical ventilation with active humidification. This analysis reflects the investigators' intention to observe the temperature drop under real-world clinical practice conditions, while assessing potential interactions with patient body temperature, ambient temperature, and the size of unheated ventilatory connectors. These findings may provide insight into the appropriate temperature and humidity targets, thereby further optimizing active humidification during invasive mechanical ventilation.",[82],"Assess the Actual Temperature Drop of Medical Gases From the Distal End of the Heated Ventilator Circuit to the Tracheal Carina",[84,85,86,87,88],"Active Humidification","Heat Humidifier","Passover HH","temperature","ICU","2026-11-18",{"date":91,"type":92},"2026-11-23","ACTUAL",{"date":94,"type":92},"2026-06-22",{"date":96,"type":76},"2027-06-22",{"name":5,"class":6},1]