[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100666599":3},{"organization":4,"outcomesModule":7,"designInfo":33,"detailedDescription":42,"studyPopulation":38,"armGroups":43,"interventions":50,"overallOfficials":38,"centralContacts":56,"locations":62,"responsibleParty":92,"collaborators":94,"id":97,"slug":98,"hasResults":99,"nctId":100,"briefTitle":101,"officialTitle":102,"acronym":103,"eligibilityCriteria":104,"healthyVolunteers":99,"sex":105,"minAge":106,"maxAge":38,"enrollmentInfo":107,"targetDuration":38,"studyType":110,"phases":111,"briefSummary":112,"conditions":113,"keywords":118,"overallStatus":65,"whyStopped":38,"lastUpdateSubmitDate":131,"lastUpdatePostDateStruct":132,"startDateStruct":135,"completionDateStruct":137,"leadSponsor":139,"locationsCount":140},{"fullName":5,"class":6},"Nimble Diagnostics S.L.","INDUSTRY",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":29},[9],{"measure":10,"description":11,"timeFrame":12},"Heartbeat-Synchronous Signal Detection Rate in Post-PCI Acquisitions","Proportion of assessable post-PCI pre-measurement acquisitions in which a heartbeat-synchronous microwave signal is detected, defined by the presence of statistically significant periodic modulation of the microwave signal at the cardiac frequency using the electrocardiogram (ECG) signal as the temporal cardiac-cycle reference.","Day 1 (day of the PCI procedure)",[14,17,20,23,26],{"measure":15,"description":16,"timeFrame":12},"False Detection Rate","Proportion of assessable acquisitions exhibiting stent-compatible microwave patterns that do not demonstrate heartbeat-linked periodicity and are therefore classified as non-cardiac or artifactual reflections.",{"measure":18,"description":19,"timeFrame":12},"Intra-Patient Measurement Repeatability","Repeatability of repeated WAEVE acquisitions performed under identical acquisition conditions within the same session, quantified using the Measurement Stability Index (MSI). The Measurement Stability Index ranges from 0 to 1, with higher values indicating greater agreement between repeated acquisitions",{"measure":21,"description":22,"timeFrame":12},"Proportion of Technically Assessable Acquisitions","Proportion of acquisitions meeting predefined signal-quality criteria and considered suitable for analysis",{"measure":24,"description":25,"timeFrame":12},"Signal Changes Associated With Stent Implantation","Within-subject differences between pre-PCI and post-PCI microwave reflection characteristics at matched anatomical sites, summarized using reflection morphology features and the Peak Prominence Difference Index (PPDI).",{"measure":27,"description":28,"timeFrame":12},"Heart Rate Agreement Between Microwave-Derived and ECG-Derived Signals","Agreement between heart rate estimated from microwave reflections and heart rate derived from ECG, summarized using Heart Rate Error (HRE).",[30],{"measure":31,"description":32,"timeFrame":12},"Association Between Inflammatory Biomarkers and WAEVE® Signal Parameters","Exploratory correlations between inflammatory biomarker levels and selected WAEVE® signal characteristics, including heartbeat-synchronous signal metrics and stent-related reflection features.",{"allocation":34,"interventionModel":35,"interventionModelDescription":36,"primaryPurpose":37,"observationalModel":38,"timePerspective":38,"maskingInfo":39},"NA","SINGLE_GROUP","Single-arm, prospective, multicenter clinical investigation in which all enrolled participants undergo WAEVE® measurements before elective PCI. Participants receiving a single coronary stent during PCI undergo additional post-PCI WAEVE® measurements and contribute to the primary analysis cohort. No randomization or comparison group is included.","OTHER",null,{"masking":40,"maskingDescription":41,"whoMasked":38},"NONE","This is an open-label study. During WAEVE® measurements, operators are not informed whether the acquired microwave reflections correspond to true cardiac and stent-related signals or to non-cardiac or artifactual reflections. Assessment of heartbeat synchrony and signal origin is performed retrospectively through offline analysis by designated engineering personnel according to predefined algorithms and procedures.","Coronary artery disease (CAD) remains one of the leading causes of morbidity and mortality worldwide. Percutaneous coronary intervention (PCI) with coronary stent implantation is a widely used treatment for restoring coronary blood flow in patients with obstructive coronary artery disease. Despite significant advances in stent technology, in-stent restenosis (ISR) and other stent-related complications remain clinically relevant and often require further diagnostic evaluation and treatment.\n\nCurrent methods for evaluating implanted coronary stents, including invasive coronary angiography and intravascular imaging techniques, are associated with procedural risks, resource utilization, and patient burden. Furthermore, these methods are not suitable for frequent or routine monitoring. Consequently, there is an unmet clinical need for non-invasive, non-ionizing technologies capable of assessing implanted coronary stents and supporting longitudinal patient follow-up.\n\nWAEVE® is an investigational active medical device developed by NIMBLE Diagnostics, S.L. that uses microwave interferometry to non-invasively assess implanted coronary stents. The technology is based on the interaction between low-power microwave signals and metallic coronary stents. Reflected signals are captured and analyzed to extract information related to the presence and behavior of the implanted device. Previous technical and clinical investigations have demonstrated the feasibility of detecting stent-related microwave reflections and have supported the continued development of the technology.\n\nAs part of the ongoing development of WAEVE®, a new pre-measurement feature has been incorporated into the system. This feature evaluates whether detected microwave reflections exhibit modulation synchronized with the cardiac cycle by using the electrocardiogram (ECG) signal as a temporal reference. The underlying rationale is that reflections originating from implanted coronary stents should demonstrate a heartbeat-synchronous pattern due to the cyclic motion and deformation of the coronary arteries during the cardiac cycle. In contrast, reflections originating from external structures, environmental sources, patient movement, or other non-cardiac artifacts are not expected to exhibit this physiological synchronization.\n\nBy confirming the cardiac origin of the detected reflection, the pre-measurement feature is intended to improve the robustness and reliability of WAEVE® measurements and reduce the risk of false detections arising from non-cardiac or artifactual reflections. The feature is designed to support operators in identifying measurements that are more likely to contain true stent-related information before the acquisition is accepted for further analysis.\n\nThe NIMBLE-II study is a prospective, multicenter, single-arm clinical investigation designed to evaluate the technical performance of this pre-measurement feature under real-world clinical conditions. The study will be conducted in Spain and will enroll adult patients undergoing elective PCI. Participants without previously implanted coronary stents will undergo WAEVE® measurements before PCI. Patients in whom a single coronary stent is successfully implanted during the procedure will undergo additional post-PCI measurements and will contribute to the primary analysis cohort.\n\nThe primary objective of the study is to determine the proportion of post-PCI pre-measurement acquisitions in which a heartbeat-synchronous microwave signal is detected. Secondary objectives include the characterization of false detections, assessment of heartbeat synchronism metrics, evaluation of signal repeatability and measurement stability, assessment of signal changes associated with stent implantation, and evaluation of operational performance indicators. Additional analyses will explore factors that may influence signal acquisition and detection performance.\n\nAn exploratory substudy conducted at Hospital Universitari Germans Trias i Pujol will investigate inflammatory biomarkers associated with PCI and evaluate potential relationships between biomarker levels and WAEVE® signal characteristics. These analyses are intended to generate hypotheses and support future research regarding the biological and physiological factors that may influence microwave signal behavior following stent implantation.\n\nThe results of the NIMBLE-II study are expected to provide technical and clinical validation evidence supporting the performance of the WAEVE® pre-measurement feature and contribute to the continued development of a non-invasive, non-ionizing technology for the assessment of implanted coronary stents.",[44],{"label":45,"type":46,"description":47,"interventionNames":48},"WAEVE® Assessment","EXPERIMENTAL","Participants undergoing elective percutaneous coronary intervention (PCI) will undergo WAEVE® measurements before PCI. Participants receiving a single coronary stent during PCI will undergo additional post-PCI WAEVE® measurements for evaluation of the study endpoints.",[49],"Device: WAEVE®",[51],{"type":52,"name":53,"description":54,"armGroupLabels":55,"otherNames":38},"DEVICE","WAEVE®","WAEVE® is an investigational, non-invasive, non-ionizing medical device that uses microwave interferometry to detect and analyze microwave reflections associated with implanted coronary stents. Participants undergo WAEVE® measurements before PCI and, when applicable, after coronary stent implantation. The study evaluates the performance of a pre-measurement feature designed to detect heartbeat-synchronous microwave reflections and distinguish true cardiac and stent-related signals from non-cardiac or artifactual reflections.",[45],[57],{"name":58,"role":59,"phone":60,"phoneExt":38,"email":61},"Oriol Rodríguez Leor, MD, PhD","CONTACT","93 465 12 00","orodriguez.germanstrias@gencat.cat",[63,82],{"facility":64,"status":65,"city":66,"state":67,"zip":68,"country":69,"countryCode":70,"cosmosGeoPoint":71,"geoPoint":76,"contacts":77},"Hospital Universitari Germans Trias i Pujol","RECRUITING","Badalona","Catalonia","08916","Spain","ES",{"type":72,"coordinates":73},"Point",[74,75],2.24741,41.45004,{"lat":75,"lon":74},[78],{"name":79,"role":59,"phone":80,"phoneExt":38,"email":81},"Oriol Rodriguez Leor, MD, PhD","(+34) 934 97 89 89","icor@icor.cat",{"facility":83,"status":84,"city":85,"state":67,"zip":86,"country":69,"countryCode":70,"cosmosGeoPoint":87,"geoPoint":91,"contacts":38},"Hospital Universitari de Bellvitge","NOT_YET_RECRUITING","L'Hospitalet de Llobregat","08907",{"type":72,"coordinates":88},[89,90],2.10028,41.35967,{"lat":90,"lon":89},{"type":93,"investigatorFullName":38,"investigatorTitle":38,"investigatorAffiliation":38,"oldNameTitle":38,"oldOrganization":38},"SPONSOR",[95],{"name":96,"class":37},"Fundación EPIC","100666599","evaluation-of-waeve-pre-measurement-feature-for-detection-of-implanted-coronary-stents-in-patients-undergoing-elective-pci-100666599",false,"NCT07957508","Evaluation of WAEVE® Pre-Measurement Feature for Detection of Implanted Coronary Stents in Patients Undergoing Elective PCI","Evaluation of WAEVE® Pre-Measurement Feature for Detection of Implanted Coronary Stents in Patients Undergoing Elective PCI: NIMBLE-II Study","NIMBLE-II","Inclusion Criteria:\n\n* Adults ≥18 years of age.\n* scheduled for a PCI procedure with potential stent implantation and without any previously implanted coronary stent.\n* Clinically stable condition allowing completion of pre-PCI WAEVE® measurements.\n* Ability to understand the study procedures and provide written informed consent.\n\nExclusion Criteria:\n\n* Hemodynamic instability, cardiogenic shock, or severe arrhythmias.\n* Active implantable electronic devices or metallic implants on the chest that may interfere with measurements (e.g., pacemakers, defibrillators, CRT devices, sternal wires, rib plates, metallic clips).\n* Presence of skin conditions, wounds, or lesions in the areas designated for transducer placement (including extensive thoracic skin lesions).\n* Inability to remain supine or still during WAEVE® measurements.\n* Pregnancy or absence of a negative pregnancy test in women of childbearing potential.","ALL","18 Years",{"count":108,"type":109},120,"ESTIMATED","INTERVENTIONAL",[34],"Coronary stent implantation is a common treatment for coronary artery disease. However, current methods used to evaluate implanted stents and detect complications such as in-stent restenosis are generally invasive and may require ionizing radiation.\n\nThe WAEVE® device is an investigational, non-invasive, non-ionizing medical device that uses microwave interferometry to assess implanted coronary stents. The NIMBLE-II study is designed to evaluate the performance of a new pre-measurement feature incorporated into WAEVE® that detects heartbeat-synchronous microwave reflections and helps distinguish true stent-related signals from non-cardiac or artifactual signals. By confirming the cardiac origin of the detected reflection, this feature is intended to improve the robustness and reliability of WAEVE® measurements and reduce the risk of false detections arising from non-cardiac or artifactual reflections.\n\nThis prospective, multicenter, single-arm clinical investigation will enroll adults undergoing elective percutaneous coronary intervention (PCI). Participants will undergo WAEVE® measurements before PCI and, when a single coronary stent is implanted, after PCI. The study aims to generate technical and clinical evidence supporting the reliability and robustness of the WAEVE® pre-measurement feature under real clinical conditions.",[114,115,116,117],"CAD - Coronary Artery Disease","Stenosis Coronary","Coronary Stent Implantation","Microwaves",[119,120,121,122,123,124,125,126,127,128,129,130],"WAEVE","Microwave Interferometry","Coronary Stent","Percutaneous Coronary Intervention","Non-invasive Monitoring","Stent Assessment","Heartbeat-Synchronous Signal Detection","Microwave Sensing","Medical Device","Cardiac Monitoring","In-Stent Restenosis","NIMBLE Diagnostics","2026-11-17",{"date":133,"type":134},"2026-11-24","ACTUAL",{"date":136,"type":134},"2026-06-08",{"date":138,"type":109},"2027-12-31",{"name":5,"class":6},2]