[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100661172":3},{"organization":4,"outcomesModule":7,"designInfo":52,"detailedDescription":56,"studyPopulation":57,"armGroups":58,"interventions":65,"overallOfficials":76,"centralContacts":81,"locations":86,"responsibleParty":145,"collaborators":148,"id":155,"slug":156,"hasResults":157,"nctId":158,"briefTitle":159,"officialTitle":159,"acronym":160,"eligibilityCriteria":161,"healthyVolunteers":157,"sex":162,"minAge":163,"maxAge":53,"enrollmentInfo":164,"targetDuration":53,"studyType":167,"phases":53,"briefSummary":168,"conditions":169,"keywords":172,"overallStatus":179,"whyStopped":53,"lastUpdateSubmitDate":180,"lastUpdatePostDateStruct":181,"startDateStruct":184,"completionDateStruct":186,"leadSponsor":188,"locationsCount":189},{"fullName":5,"class":6},"Leiden University Medical Center","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":44},[9],{"measure":10,"description":11,"timeFrame":12},"Proportion successfully maintained monitor","The proportion of patients (%) in whom continuous tissue oximetry monitoring was successfully maintained for the entire postoperative period.","From day of surgery (day 0) until day 3 postoperative",[14,17,20,24,27,31,34,37,40],{"measure":15,"description":16,"timeFrame":12},"Surgical re-exploration","Surgical re-exploration performed because of suspected vascular compromise of the free flap. Yes\u002Fno.",{"measure":18,"description":19,"timeFrame":12},"Flap failure","Flap failure. Yes\u002Fno.",{"measure":21,"description":22,"timeFrame":23},"Flap risk score","0= no risk parameters present 6= all risk parameters present. Risk parameters are: color, consistency, capillary refill, temperature, doppler signal, clinical suspiscion. Parameters score 0 if the parameter is clinically judged to be normal\u002Foptimal and 1 if parameter is clinically judged to be suboptimal","From day of surgery (day 0) until day 3 posteroperative",{"measure":25,"description":26,"timeFrame":23},"Postoperative complications","According to Clavien-Dindo scale\n\nGrade I Any deviation from the normal postoperative course without the need for pharmacological treatment or surgical, endoscopic and radiological interventions. Allowed therapeutic regimens are: drugs as antiemetics, antipyretics, analgetics, diuretics and electrolytes and physiotherapy. This grade also includes wound infections opened at the bedside.\n\nGrade II Requiring pharmacological treatment with drugs other than such allowed for grade I complications. Blood transfusionsand total parenteral nutritionare also included.\n\nGrade III Requiring surgical, endoscopic or radiological intervention\n\n* IIIa Intervention not under general anesthesia\n* IIIb Intervention under general anesthesia\n\nGrade IV Life-threatening complication (including CNS complications)\\* requiring IC\u002FICU-management\n\n* IVa single organ dysfunction (including dialysis)\n* IVb multiorgandysfunction\n\nGrade V Death of a patient",{"measure":28,"description":29,"timeFrame":30},"INVOS risk triggers: absolute drop of StO₂","Number of absolute drops of StO₂ \\\u003C 60%.","From start of INVOS measurements (day 0) until day 3 postoperative",{"measure":32,"description":33,"timeFrame":30},"INVOS risk triggers: relative drop StO₂","Number of relative drops of StO₂ ≥20% decrease from baseline sustained ≥30 minutes.",{"measure":35,"description":36,"timeFrame":30},"INVOS risk triggers: flap-to-reference ratio","Flap-to-reference ratio of \\\u003C0.75. Yes\u002Fno",{"measure":38,"description":39,"timeFrame":23},"Incidence sensor displacement or detachment","The incidence of mechanical sensor displacement or complete detachment requiring clinical intervention or sensor replacement within the first 48 hours postoperatively.",{"measure":41,"description":42,"timeFrame":43},"Cumulative duration missing StO2 data","The cumulative duration of missing or uninterpretable tissue oxygen saturation (StO₂) data due to sensor detachment, signal artifacts, or hardware failure, expressed as a percentage (%) of the total monitoring time.","From start INVOS measurement (day 0) until day 3 postoperative",[45,48],{"measure":46,"description":47,"timeFrame":12},"Reasons of device failure","Reasons of device failure. For each case, the reason why the device failed or did not function as intended (e.g. technical malfunction, battery issue, software error, or user error) is recorded as free text. This is a qualitative outcome measure with no unit. Responses will be described and categorised afterwards to identify the most frequent causes of failure.",{"measure":49,"description":50,"timeFrame":51},"Patient satisfaction","At the end of the monitoring period (72h) the patient will be asked to rate their experience with the INVOS monitoring by answering the following questions:\n\n* Express your satisfaction with INVOS monitoring (0-5; 0 very dissatisfied - 5 very satisfied)\n* Did INVOS interfere with mobility? (0-5; 0 not at all - 5 very much)\n* Did INVOS interfere with sleep? (0-5; 0 not at all - 5 very much)\n* Did INVOS monitoring make you feel more reassured? (0-5; 0 not at all - 5 very much):\n* Would you be willing to receive INVOS monitoring for potential future postoperative monitoring? (yes\u002Fmaybe\u002Fno)\n* Would you recommend INVOS monitoring for postoperative monitoring to other patients? (yes\u002Fmaybe\u002Fno)","At day 3 postoperative",{"allocation":53,"interventionModel":53,"interventionModelDescription":53,"primaryPurpose":53,"observationalModel":54,"timePerspective":55,"maskingInfo":53},null,"COHORT","PROSPECTIVE","Reconstruction of defects using free flaps has become increasingly popular. However, vascular compromise is a potential postoperative complication leading to ischemia of (parts of the) flap. Early detection of perfusion problems is pivotal and directly correlated with increased flap salvage. Currently, detection of flap ischemia relies on frequent postoperative clinical inspection of the flap and the assessment of doppler signal of the (perforator) artery of the flap. These inspections are labor intensive and potentially suboptimal as these inspections are done in one- to four-hour intervals. Near infrared tissue oximetry using INVOStm monitoring technique allows for continuous monitoring of the flap, which may improve detection of flap ischemia and reduce the work load for health care personnel. Previous studies using NIRS for free flap monitoring have reported promising results, but available evidence is limited by differences in NIRS devices, algorithms, flap types, monitoring protocols, sensor placement, definitions of vascular compromise and proposed alarm thresholds. In addition, practical aspects of prolonged postoperative monitoring on a recovery unit or ward, including sensor adherence, signal quality, missing or uninterpretable data, patient mobility and patient experience, have not been sufficiently studied.\n\nMain objective: To assess the feasibility of postoperative INVOS tissue oximetry monitoring after free-flap reconstructive surgery.\n\nSecondary objectives:\n\nTo descriptively evaluate clinical outcomes after free-flap reconstructive surgery, including flap-at-risk episodes, surgical re-exploration, flap failure, postoperative complications and patient-reported experience with INVOS™ monitoring.\n\nStudy design: Multi-center, observational cohort study Study population: adult patients scheduled for elective free flap reconstructive surgery Main study endpoints: Successful maintenance of continuous monitoring, proportion of missing or uninterpretable StO₂ data, and sensor displacement or detachment requiring inter-vention or replacement. Nature and extent of the burden and risks associated with participation, benefit and group relatedness: Participants will receive perioperative surgical and anesthetic care as usual. At the end of surgery, INVOStm stickers will be placed at the free-flap by the surgeon. In addition, an INVOStm sticker will be placed at the femoral muscle which will serve as so-matic reference. Postoperative flap controls will follow routine protocol; no decisions will be made based on INVOStm readings.","Patients scheduled for elective free flap reconstructive surgery",[59],{"label":60,"type":53,"description":61,"interventionNames":62},"Primary cohort","Adult patients scheduled for elective free flap reconstructive surgery.",[63,64],"Procedure: Elective free flap surgery","Device: INVOS monitoring",[66,71],{"type":67,"name":68,"description":69,"armGroupLabels":70,"otherNames":53},"PROCEDURE","Elective free flap surgery","Reconstruction using deep inferior epigastric perforator (DIEP) flap. Participants will receive standard surgical, anaesthetic and postoperative care according to local practice.",[60],{"type":72,"name":73,"description":74,"armGroupLabels":75,"otherNames":53},"DEVICE","INVOS monitoring","The INVOS system (In Vivo Optical Spectroscopy). INVOS™ sensors will be applied to the free flap and to a femoral reference site for postoperative tissue oximetry monitoring. The INVOS™ monitor readings will not be visible to caregivers, alarms will be muted, and INVOS™ measurements will not be used for clinical decision-making during this study. Clinical assessment and Doppler monitoring will remain leading for all decisions regarding flap viability.",[60],[77],{"name":78,"affiliation":79,"role":80},"Martijn Boon, MD, PhD","Leiden University Medical Centre","PRINCIPAL_INVESTIGATOR",[82],{"name":78,"role":83,"phone":84,"phoneExt":53,"email":85},"CONTACT","0031 71 526 2301","m.boon@lumc.nl",[87,115,130],{"facility":79,"status":53,"city":88,"state":89,"zip":90,"country":91,"countryCode":92,"cosmosGeoPoint":93,"geoPoint":98,"contacts":99},"Leiden","South Holland","2333 ZA","Netherlands","NL",{"type":94,"coordinates":95},"Point",[96,97],4.49306,52.15833,{"lat":97,"lon":96},[100,102,104,107,109,111,113],{"name":78,"role":83,"phone":101,"phoneExt":53,"email":85},"0031 71 526 91 11",{"name":103,"role":80,"phone":53,"phoneExt":53,"email":53},"Hendrik J.F. Helmerhorst, MD, PhD",{"name":105,"role":106,"phone":53,"phoneExt":53,"email":53},"Joost R. van der Vorst, MD, PhD","SUB_INVESTIGATOR",{"name":108,"role":106,"phone":53,"phoneExt":53,"email":53},"Pieter S. Verduijn, MD, PhD",{"name":110,"role":106,"phone":53,"phoneExt":53,"email":53},"Robbert Dijkman, MD, PhD",{"name":112,"role":106,"phone":53,"phoneExt":53,"email":53},"Indy Planting, MD",{"name":114,"role":106,"phone":53,"phoneExt":53,"email":53},"Severano Verhoef, MD",{"facility":116,"status":53,"city":117,"state":89,"zip":118,"country":91,"countryCode":92,"cosmosGeoPoint":119,"geoPoint":123,"contacts":124},"Haaglanden Medisch Centrum, locatie Anthoniushove","Leidschendam","2262 BA",{"type":94,"coordinates":120},[121,122],4.39281,52.08167,{"lat":122,"lon":121},[125,129],{"name":126,"role":83,"phone":127,"phoneExt":53,"email":128},"Yuen M. Cheung, MD, PhD","0031 88 979 79 00","y.cheung@haaglandenmc.nl",{"name":126,"role":106,"phone":53,"phoneExt":53,"email":53},{"facility":131,"status":53,"city":132,"state":89,"zip":133,"country":91,"countryCode":92,"cosmosGeoPoint":134,"geoPoint":138,"contacts":139},"HagaZiekenhuis","The Hague","2545 AA",{"type":94,"coordinates":135},[136,137],4.29861,52.07667,{"lat":137,"lon":136},[140,144],{"name":141,"role":83,"phone":142,"phoneExt":53,"email":143},"Mandana Rad, MD, PhD","0031 70 210 0000","m.rad@hagaziekenhuis.nl",{"name":141,"role":106,"phone":53,"phoneExt":53,"email":53},{"type":80,"investigatorFullName":146,"investigatorTitle":147,"investigatorAffiliation":5,"oldNameTitle":53,"oldOrganization":53},"Martijn Boon","MD, PhD",[149,150,153],{"name":131,"class":6},{"name":151,"class":152},"Medtronic","INDUSTRY",{"name":154,"class":6},"Medical Center Haaglanden","100661172","flap-assessment-with-regional-oximetry-for-early-detection-of-compromise-in-free-flap-reconstructive-surgery---flare-study-100661172",false,"NCT07887256","Flap Assessment With Regional Oximetry for Early Detection of Compromise in Free Flap Reconstructive Surgery - FLARE Study","FLARE","Inclusion Criteria:\n\n* Patients 18 years or older who are schedulded for elective free flap reconstructive surgery\n\nExclusion Criteria:\n\n* Severe cardiac comorbidities (NYHA heart failure \\>2)\n* Severe pulmonary comorbidities (MET\\\u003C4)\n* Oxygen saturation level \\\u003C 90% without supplemental oxygen during preop visit\n* Any contraindications for INVOStm monitoring\n* Inability or refusal to complete informed consent form\n* Absence of an adequate site for safe and reliable INVOS™ sensor placement on or near the free flap, or for placement of the reference sensor, as determined by the treating plastic surgeon","ALL","18 Years",{"count":165,"type":166},100,"ESTIMATED","OBSERVATIONAL","After some operations in which tissue is removed, it is necessary to repair the defect with a piece of tissue from another location in the body. This is called a microsurgically transplanted tissue flap (or tissue flap, for short). It is important that, after an operation, enough blood flows to the relocated tissue. In this study, we want to investigate whether, after the operation, measuring oxygen in the tissue flap with the INVOS 7100c device helps detect blood flow problems earlier. In the future, this could help doctors intervene more quickly, thereby reducing the risk of complications.",[170,171],"Reconstructive Surgery","Flap Monitoring",[173,174,175,176,177,178],"DIEP","INVOS","Reconstructive surgery","Free flap surgery","Near-infrared spectroscopy","Flap monitoring","NOT_YET_RECRUITING","2026-10-14",{"date":182,"type":183},"2026-10-21","ACTUAL",{"date":185,"type":166},"2026-12",{"date":187,"type":166},"2028-12",{"name":5,"class":6},3]