[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100665453":3},{"organization":4,"outcomesModule":7,"designInfo":86,"detailedDescription":85,"studyPopulation":85,"armGroups":95,"interventions":110,"overallOfficials":128,"centralContacts":133,"locations":138,"responsibleParty":151,"collaborators":85,"id":154,"slug":155,"hasResults":156,"nctId":157,"briefTitle":158,"officialTitle":159,"acronym":160,"eligibilityCriteria":161,"healthyVolunteers":156,"sex":162,"minAge":163,"maxAge":164,"enrollmentInfo":165,"targetDuration":85,"studyType":168,"phases":169,"briefSummary":171,"conditions":172,"keywords":174,"overallStatus":179,"whyStopped":85,"lastUpdateSubmitDate":180,"lastUpdatePostDateStruct":181,"startDateStruct":184,"completionDateStruct":186,"leadSponsor":188,"locationsCount":189},{"fullName":5,"class":6},"The University of Hong Kong","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":17,"otherOutcomes":85},[9,13],{"measure":10,"description":11,"timeFrame":12},"Total Fluoroscopy Time","The total duration, measured in minutes or seconds, that the X-ray beam is actively turned on during a fluoroscopic procedure during the operation.","Intra-operative",{"measure":14,"description":15,"timeFrame":16},"Functional Assessment measured by QuickDASH Score","The QuickDASH score is a validated, internationally recognized tool to assess functional outcomes of patients of the upper arm, especially in long term recovery assessments. The survey will assess the control group against intervention group in return to daily activities, assessment of overall upper limb function, symptoms, and quality of life.","At post-op, 3 weeks, 6 weeks , 3 months and 6 months",[18,22,25,28,31,34,37,40,43,46,49,52,55,58,61,64,67,70,73,76,79,82],{"measure":19,"description":20,"timeFrame":21},"Rating of placement of implant using 25 point Surgeon-Reported Outcome Measures","The qualitative assessment of 1 to 5 of the placement of implant rated by the surgeon.","Immediately after operation",{"measure":23,"description":24,"timeFrame":21},"Rating of ergonomics and visualisation of plate position using 25 point Surgeon-Reported Outcome Measures","The qualitative assessment of 1 to 5 of the ergonomics and visualisation of plate position rated by the surgeon.",{"measure":26,"description":27,"timeFrame":21},"Rating of retraction during fluoroscopy using 25 point Surgeon-Reported Outcome Measures","The qualitative assessment of 1 to 5 of the retraction during fluoroscopy rated by the surgeon.",{"measure":29,"description":30,"timeFrame":21},"Rating of fracture reduction using 25 point Surgeon-Reported Outcome Measures","The qualitative assessment of 1 to 5 of the quality of fracture reduction rated by the surgeon.",{"measure":32,"description":33,"timeFrame":21},"Rating of overall assistants' efforts using 25 point Surgeon-Reported Outcome Measures","The qualitative assessment of 1 to 5 of the quality of overall assistants' efforts rated by the surgeon.",{"measure":35,"description":36,"timeFrame":12},"Number of surgical assistants","The maximum number of surgical assistants required for retraction tasks at any single point during the surgery.",{"measure":38,"description":39,"timeFrame":12},"Number of times retractors were removed and replaced","The number of times the whole RRRR or the metal retractor is lifted out of the incision site, then putting it back count as 1.",{"measure":41,"description":42,"timeFrame":12},"Number of times the retractor was loosened from the surgical site","The number of times the traditional retractor or RRRR is not adequately retracting the surgical wound and providing a clear view of the fracture site,",{"measure":44,"description":45,"timeFrame":12},"Number of readjustments for fracture reduction","The number of times that a fracture reduction is changed during the operation.",{"measure":47,"description":48,"timeFrame":12},"Number of attempts for repositioning Kirschner wire","The numbers of times the Kirschner wire is removed from the incision site and then putting it back count as 1.",{"measure":50,"description":51,"timeFrame":12},"Maximum number of Kirschner wire used to maintain positioning and\u002For reduction","The maximum number of Kirschner wires at any time point that are used to maintain implant positioning and\u002For fracture reduction.",{"measure":53,"description":54,"timeFrame":12},"Number of repositioning of plates","The number of times the implant plate is moved and repositioned is recorded as 1.",{"measure":56,"description":57,"timeFrame":12},"Number of repositioning of screws","The number of times the screw is removed from the incision site and repositioned is recorded as 1.",{"measure":59,"description":60,"timeFrame":12},"Total number of screws used in the operation","The total number of screws that are used in the operation, including those that are implanted or wasted.",{"measure":62,"description":63,"timeFrame":12},"Number of head turns to assess x-ray images","The number of times the primary surgeon looks at the fluoroscopy monitor during fracture reduction.",{"measure":65,"description":66,"timeFrame":12},"Number of times the eyepiece focus is lost","The number of times the AR HMD eyepiece is out of focus is recorded as 1.",{"measure":68,"description":69,"timeFrame":12},"Duration of surgery","Defined from the time difference of the incision start time and the completion time of final suturing.",{"measure":71,"description":72,"timeFrame":12},"Incision Length in mm","Defined as the length in millimeters of the incision cut in the surgery.",{"measure":74,"description":75,"timeFrame":16},"Radial Inclination in degrees","Measurement of the coronal-plane slope of the distal radius articular surface, measured in pre-operative and post-operative wrist x-ray.",{"measure":77,"description":78,"timeFrame":16},"Radial Height in millimeters","Measurement of the axial distance between perpendicular lines at the radial styloid and ulnar border, quantifying fracture-induced radial shortening, measured in pre-operative and post-operative wrist x-ray.",{"measure":80,"description":81,"timeFrame":16},"Volar \u002F Dorsal Angulation in degrees","Measurement of the tilt of the distal articular surface relative to the shaft, measured in pre-operative and post-operative wrist x-ray.",{"measure":83,"description":84,"timeFrame":16},"Articular Step-off in millimeters","Measurement of the vertical incongruity along the subchondral surface, measured in pre-operative and post-operative wrist x-ray.",null,{"allocation":87,"interventionModel":88,"interventionModelDescription":89,"primaryPurpose":90,"observationalModel":85,"timePerspective":85,"maskingInfo":91},"RANDOMIZED","PARALLEL","Participants are randomly assigned to either one of the interventional arm and will not be informed of the randomisation result.","TREATMENT",{"masking":92,"maskingDescription":85,"whoMasked":93},"SINGLE",[94],"PARTICIPANT",[96,103],{"label":97,"type":98,"description":99,"interventionNames":100},"Radius Radiolucent Ring Retractor and the Augmented Reality Glasses","EXPERIMENTAL","The surgery will be completed with the combination of Radius Radiolucent Ring Retractor (RRRR) and Augmented Reality Glasses.\n\nThe RRRR is a 3D-printed surgical tool designed for hands-free retraction in arm and wrist surgeries.\n\nThe Augmented Reality Glasses for surgeons designed specifically for surgeons can display real-time X-ray images directly in the doctor's field of vision, allowing the doctor to focus on the wrist throughout the procedure without having to turn their head to look at the X-ray screen.",[101,102],"Device: Radial Radiolucent Ring Retractor","Device: Augmented Reality Glasses",{"label":104,"type":105,"description":106,"interventionNames":107},"Metal tools and standard X-ray monitor","ACTIVE_COMPARATOR","Traditional method with metal retractors and standard X-ray monitor.",[108,109],"Device: Metal Retractor","Device: Standard X-ray monitor",[111,116,120,124],{"type":112,"name":113,"description":114,"armGroupLabels":115,"otherNames":85},"DEVICE","Radial Radiolucent Ring Retractor","The Radius Radiolucent Ring Retractor (RRRR) is a single-use, 3D-printed nylon surgical device designed for hands-free retraction in arm and wrist surgeries.",[97],{"type":112,"name":117,"description":118,"armGroupLabels":119,"otherNames":85},"Augmented Reality Glasses","Augmented Reality of C-Arm intraoperative fluoroscopic imaging integration with a head mount-display (HMD).",[97],{"type":112,"name":121,"description":122,"armGroupLabels":123,"otherNames":85},"Metal Retractor","Manual traditional metal retractor used by surgeons and assistants.",[104],{"type":112,"name":125,"description":126,"armGroupLabels":127,"otherNames":85},"Standard X-ray monitor","Standard X-ray monitor that displays fluoroscopy images during the operation.",[104],[129],{"name":130,"affiliation":131,"role":132},"Christian Prof. Fang","Dept of Orthopaedics and Traumatology, Queen Mary Hospital","PRINCIPAL_INVESTIGATOR",[134],{"name":130,"role":135,"phone":136,"phoneExt":85,"email":137},"CONTACT","+852 22554581","cfang@hku.hk",[139],{"facility":140,"status":85,"city":141,"state":85,"zip":85,"country":141,"countryCode":142,"cosmosGeoPoint":143,"geoPoint":148,"contacts":149},"Queen Mary Hospital, The University of Hong Kong","Hong Kong","HK",{"type":144,"coordinates":145},"Point",[146,147],114.17469,22.27832,{"lat":147,"lon":146},[150],{"name":130,"role":135,"phone":136,"phoneExt":85,"email":137},{"type":132,"investigatorFullName":152,"investigatorTitle":153,"investigatorAffiliation":5,"oldNameTitle":85,"oldOrganization":85},"Prof. Christian Xinshuo Fang","Clinical Associate Professor","100665453","fracture-internal-x-fixation-with-augmented-reality-and-radiolucent-ring-retraction-100665453",false,"NCT07943845","Fracture Internal X-fixation With Augmented Reality and Radiolucent Ring Retraction","Fracture Internal X-fixation With Augmented Reality and Radiolucent Ring Retraction: A Prospective Randomised Controlled Trial","FIXAR","Inclusion Criteria:\n\n* Adults (18-85 years)\n* Distal radial fractures requiring Open Reduction and Internal Fixation.\n* Patients that would be suitable for the volar approach.\n\nExclusion Criteria:\n\n* Open fractures\n* Active infection\n* Polytrauma patients where the wrist is not the primary focus.","ALL","18 Years","85 Years",{"count":166,"type":167},94,"ESTIMATED","INTERVENTIONAL",[170],"NA","The surgical management of distal radius fractures via open reduction and internal fixation (ORIF) remains the gold standard for restoring wrist function. However, the procedure is traditionally characterized by repetitive workflow interruptions of the removal of metallic retractors to avoid radiological artifacts and the ergonomic strain of the \"head-turn\" required to view distant fluoroscopy monitors.\n\nThe Radius Radiolucent Ring Retractor (RRRR) is a single-use, 3D-printed nylon surgical device designed for hands-free retraction in arm and wrist surgeries. This device was developed at the University of Hong Kong and invention is held by HKU Versitech Limited.\n\nThis study aims to definitively evaluate the gadget-optimized distal radius fixation surgery with the RRRR and head-mounted Augmented Reality glasses display to optimize the surgical workflow. This trial will evaluate whether this system provides a more efficient alternative to conventional monitor-based fluoroscopy in modern orthopedic practice.",[173],"Distal Radius Fracture",[175,176,177,178],"Augmented Reality","3D Printing","Distal Radial Fracture","Patient outcomes","NOT_YET_RECRUITING","2026-11-13",{"date":182,"type":183},"2026-11-17","ACTUAL",{"date":185,"type":167},"2026-12-01",{"date":187,"type":167},"2028-03-31",{"name":5,"class":6},1]