[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100660862":3},{"organization":4,"outcomesModule":7,"designInfo":30,"detailedDescription":36,"studyPopulation":29,"armGroups":37,"interventions":44,"overallOfficials":29,"centralContacts":50,"locations":57,"responsibleParty":73,"collaborators":29,"id":77,"slug":78,"hasResults":79,"nctId":80,"briefTitle":81,"officialTitle":82,"acronym":83,"eligibilityCriteria":84,"healthyVolunteers":79,"sex":85,"minAge":86,"maxAge":29,"enrollmentInfo":87,"targetDuration":29,"studyType":90,"phases":91,"briefSummary":92,"conditions":93,"keywords":96,"overallStatus":106,"whyStopped":29,"lastUpdateSubmitDate":107,"lastUpdatePostDateStruct":108,"startDateStruct":111,"completionDateStruct":113,"leadSponsor":115,"locationsCount":116},{"fullName":5,"class":6},"Universität Münster","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":16,"otherOutcomes":29},[9,13],{"measure":10,"description":11,"timeFrame":12},"Target Registration Error After Multimodal Breast Image Registration","Target Registration Error (TRE) will be used to quantify the spatial accuracy of registration between corresponding breast imaging datasets. TRE will be calculated as the distance in mm between predefined corresponding anatomical or imaging reference points after registration. Lower TRE values indicate greater registration accuracy. Registration performance will be assessed for datasets acquired in different body positions and for datasets acquired in comparable prone breast positions.","Up to 4 months after completion of imaging acquisition for each participant",{"measure":14,"description":15,"timeFrame":12},"Mean Three-Dimensional Structural Similarity Index (3D-SSIM) Between Registered PET Datasets","Structural similarity between the registered PET datasets acquired as part of PET\u002FCT and PET\u002FMRI will be assessed using the three-dimensional Structural Similarity Index (3D-SSIM), implemented in Python using the scikit-image library. The index provides a dimensionless measure of similarity in spatial image patterns, with higher values indicating greater structural similarity and a value of 1 representing perfect similarity. The 3D-SSIM will be calculated within the registered breast image volume for each registration approach and acquisition setting to assess registration performance and the effect of comparable breast positioning on registration quality.",[17,20,23,26],{"measure":18,"description":19,"timeFrame":12},"Absolute Difference in SUVmax After Image Deformation","The maximum standardized uptake value (SUVmax) will be measured in corresponding regions of the original PET dataset and the PET dataset after application of the calculated deformation field. The absolute difference in SUVmax between the original and deformed datasets will be calculated to quantify changes in quantitative PET information introduced by image deformation. The mean absolute difference in SUVmax will be compared across registration methods and patient positioning conditions to assess the robustness of the registration approaches and whether reduced positioning differences improve quantitative stability.",{"measure":21,"description":22,"timeFrame":12},"Absolute Difference in SUVmean After Image Deformation","The mean standardized uptake value (SUVmean) will be measured in corresponding regions of the original PET dataset and the PET dataset after application of the calculated deformation field. The absolute difference in SUVmean between the original and deformed datasets will be calculated to quantify changes in quantitative PET information introduced by image deformation. The mean absolute difference in SUVmean will be compared across registration methods and patient positioning conditions to assess the robustness of the registration approaches and whether reduced positioning differences improve quantitative stability.",{"measure":24,"description":25,"timeFrame":12},"Absolute Difference in SUVpeak After Image Deformation","The peak standardized uptake value (SUVpeak) will be measured in corresponding regions of the original PET dataset and the PET dataset after application of the calculated deformation field. The absolute difference in SUVpeak between the original and deformed datasets will be calculated to quantify changes in quantitative PET information introduced by image deformation. The mean absolute difference in SUVpeak will be compared across registration methods and patient positioning conditions to assess the robustness of the registration approaches and whether reduced positioning differences improve quantitative stability.",{"measure":27,"description":28,"timeFrame":12},"Absolute Difference in SUVmax-Based Tumor-to-Background Ratio After Image Deformation","The tumor-to-background ratio based on maximum standardized uptake value (TBRmax) will be calculated in corresponding regions of the original PET dataset and the PET dataset after application of the calculated deformation field. The absolute difference in TBRmax between the original and deformed datasets will be calculated to quantify changes in quantitative PET contrast introduced by image deformation. The mean absolute difference in TBRmax will be compared across registration methods and patient positioning conditions to assess the robustness of the registration approaches and whether reduced positioning differences improve quantitative stability.",null,{"allocation":31,"interventionModel":32,"interventionModelDescription":29,"primaryPurpose":33,"observationalModel":29,"timePerspective":29,"maskingInfo":34},"NA","SINGLE_GROUP","DIAGNOSTIC",{"masking":35,"maskingDescription":29,"whoMasked":29},"NONE","PET\u002FCT and MRI provide complementary functional and anatomical information for breast imaging. However, direct spatial integration of separately acquired PET\u002FCT and MRI datasets is limited by differences in patient positioning and the resulting deformation of the breast. Routine PET\u002FCT is generally performed in the supine position, whereas dedicated breast MRI is acquired in the prone position with the breasts positioned within a breast coil. These differences can lead to substantial spatial discrepancies between corresponding findings.\n\nREPOSE-Breast investigates a combined acquisition- and registration-based approach to reduce these discrepancies. The study includes patients who are already scheduled to undergo both PET\u002FCT and PET\u002FMRI as part of their clinical diagnostic work-up.\n\nAs part of the study, participants undergo an additional low-dose CT acquisition and an additional PET acquisition in a dedicated prone breast position. The additional PET acquisition uses the radiotracer that has already been administered for the clinically indicated PET examination; no additional tracer injection is required. The study-specific prone acquisition is intended to reduce positioning-related differences between PET\u002FCT and MRI before subsequent image registration is performed.\n\nThe acquired PET\u002FCT and MRI datasets will then be spatially aligned using several registration approaches of increasing methodological complexity. These include rigid registration, simple deformable registration, diffeomorphic deformable registration, and a biomechanical registration approach incorporating tissue deformation.\n\nAnatomical information derived from CT and MRI is used to support the registration process and its validation. The resulting transformations will be applied to the corresponding imaging data to assess how accurately anatomical and functional findings can be transferred between PET\u002FCT and MRI.\n\nThe overall aim is to determine whether the combination of dedicated prone breast positioning and non-rigid image registration can improve the spatial integration of separately acquired PET\u002FCT and MRI datasets. This approach is intended to facilitate more reliable assignment of PET findings to the corresponding anatomical structures on MRI without requiring simultaneous PET\u002FMRI acquisition.",[38],{"label":39,"type":40,"description":41,"interventionNames":42},"Additional Prone Breast PET\u002FCT Acquisition","EXPERIMENTAL","Participants undergo an additional PET acquisition and a low-dose CT scan in a dedicated prone breast position. The PET acquisition uses the radiotracer already administered for the clinically indicated PET examination; no additional tracer injection is required. The study-specific acquisition is performed to reduce positioning-related differences between PET\u002FCT and breast MRI and to provide image data for subsequent multimodal image registration.",[43],"Diagnostic Test: Prone Breast PET\u002FCT Acquisition",[45],{"type":46,"name":47,"description":48,"armGroupLabels":49,"otherNames":29},"DIAGNOSTIC_TEST","Prone Breast PET\u002FCT Acquisition","Participants undergo an additional PET acquisition and a low-dose CT acquisition in a dedicated prone breast position using a breast-specific positioning setup. The study-specific imaging procedure takes approximately 6-10 minutes. The PET acquisition is performed after the clinically indicated radiotracer administration and does not require an additional tracer injection. The study-specific acquisition is designed to reduce differences in breast shape and position between PET\u002FCT and prone breast MRI and to provide image data for subsequent multimodal image registration.",[39],[51],{"name":52,"role":53,"phone":54,"phoneExt":55,"email":56},"Philippe Brüggemann, Dr. med.","CONTACT","+4925183","47362","nuklearmedizin@ukmuenster.de",[58],{"facility":59,"status":29,"city":60,"state":61,"zip":62,"country":63,"countryCode":64,"cosmosGeoPoint":65,"geoPoint":70,"contacts":71},"Department of Nuclear Medicine, University Hospital Münster","Münster","North Rhine-Westphalia","48149","Germany","DE",{"type":66,"coordinates":67},"Point",[68,69],7.62571,51.96236,{"lat":69,"lon":68},[72],{"name":52,"role":53,"phone":54,"phoneExt":55,"email":56},{"type":74,"investigatorFullName":75,"investigatorTitle":76,"investigatorAffiliation":5,"oldNameTitle":29,"oldOrganization":29},"PRINCIPAL_INVESTIGATOR","Philippe Brüggemann","Physician and Researcher, Department of Nuclear Medicine","100660862","improving-combined-petct-and-mri-of-the-breast-using-dedicated-breast-positioning-and-image-registration-100660862",false,"NCT07883460","Improving Combined PET\u002FCT and MRI of the Breast Using Dedicated Breast Positioning and Image Registration","Development and Validation of a Multimodal, Non-Rigid Registration Method for Hybrid Imaging of the Breast","REPOSE-Breast","Inclusion Criteria:\n\n* Female sex\n* Clinically indicated PET\u002FCT and PET\u002FMRI of the breast\n* Histologically confirmed breast cancer\n\nExclusion Criteria:\n\n* Age under 18 years\n* Pregnancy\n* Lack of capacity to provide informed consent\n* Possible conception within the previous 14 days\n* Inability to remain still in the prone position for approximately 10 minutes","FEMALE","18 Years",{"count":88,"type":89},20,"ESTIMATED","INTERVENTIONAL",[31],"The goal of this clinical trial is to improve the combined use of PET\u002FCT and MRI for imaging of the breast. PET\u002FCT and MRI are usually performed in different body positions, which can change the shape and position of the breast and make it difficult to accurately align findings between the two examinations.\n\nThe main questions this study aims to answer are:\n\nCan dedicated breast positioning during PET\u002FCT reduce differences in breast shape and position compared with MRI?\n\nCan image registration methods further improve the alignment of PET\u002FCT and MRI images of the breast?\n\nHow accurately can findings seen on PET\u002FCT be transferred to the corresponding location on MRI?\n\nParticipants in this study are breast cancer patients who are already scheduled to undergo PET\u002FCT and PET\u002FMRI as part of their clinical care. As part of the study, they will undergo an additional low-dose CT scan and an additional PET acquisition in a dedicated prone breast position. The additional PET images will be acquired using the tracer that has already been administered for the clinically indicated PET examination; no additional tracer injection is required.\n\nThe imaging data will then be used to develop and evaluate different methods for aligning PET\u002FCT and MRI images of the breast.\n\nThe study does not investigate a new drug or treatment.",[94,95],"Breast Cancer","Breast - Female",[97,98,99,100,101,102,103,104,105],"Breast Imaging","Positron Emission Tomography Computed Tomography","Hybrid Imaging","Breast Positioning","Prone Breast Imaging","Non-Rigid Image Registration","Deformable Image Registration","Multimodal Imaging Image Registration","Magnetic Resonance Imaging","NOT_YET_RECRUITING","2026-10-12",{"date":109,"type":110},"2026-10-20","ACTUAL",{"date":112,"type":89},"2026-10-06",{"date":114,"type":89},"2027-09-30",{"name":5,"class":6},1]