[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100666509":3},{"organization":4,"outcomesModule":7,"designInfo":20,"detailedDescription":26,"studyPopulation":11,"armGroups":27,"interventions":35,"overallOfficials":11,"centralContacts":46,"locations":56,"responsibleParty":75,"collaborators":11,"id":77,"slug":78,"hasResults":79,"nctId":80,"briefTitle":81,"officialTitle":81,"acronym":82,"eligibilityCriteria":83,"healthyVolunteers":79,"sex":84,"minAge":85,"maxAge":11,"enrollmentInfo":86,"targetDuration":11,"studyType":89,"phases":90,"briefSummary":91,"conditions":92,"keywords":96,"overallStatus":98,"whyStopped":11,"lastUpdateSubmitDate":99,"lastUpdatePostDateStruct":100,"startDateStruct":103,"completionDateStruct":105,"leadSponsor":107,"locationsCount":108},{"fullName":5,"class":6},"Abbott Medical Devices","INDUSTRY",{"primaryOutcomes":8,"secondaryOutcomes":11,"otherOutcomes":11},[9,13,16],{"measure":10,"description":11,"timeFrame":12},"Occurrence of specific adverse events with onset within 7 days of procedure",null,"From procedure to 7 days post procedure",{"measure":14,"description":11,"timeFrame":15},"Confirmation of entrance block in all targeted pulmonary veins","20 minutes after initial PVI",{"measure":17,"description":18,"timeFrame":19},"Freedom from documented AFL","Collected via holter monitor","12 months post initial procedure",{"allocation":21,"interventionModel":22,"interventionModelDescription":11,"primaryPurpose":23,"observationalModel":11,"timePerspective":11,"maskingInfo":24},"NA","SINGLE_GROUP","TREATMENT",{"masking":25,"maskingDescription":11,"whoMasked":11},"NONE","The primary objective of the study is to demonstrate continued safety and effectiveness of the commercially approved Volt PFA System for treating symptomatic, drug-refractory, recurrent PAF and PersAF during real-world use.",[28],{"label":29,"type":30,"description":31,"interventionNames":32},"treatment","EXPERIMENTAL","Ablation procedure using Volt PFA System in patients indicated for PAF or PersAF Treatment",[33,34],"Procedure: PVI","Device: Pulse Field Ablation",[36,41],{"type":37,"name":38,"description":39,"armGroupLabels":40,"otherNames":11},"PROCEDURE","PVI","PFA Ablation",[29],{"type":42,"name":43,"description":44,"armGroupLabels":45,"otherNames":11},"DEVICE","Pulse Field Ablation","Ablation",[29],[47,52],{"name":48,"role":49,"phone":50,"phoneExt":11,"email":51},"Elizabeth Komosa","CONTACT","612 297 0005","elizabeth.komosa@abbott.com",{"name":53,"role":49,"phone":54,"phoneExt":11,"email":55},"Katie Trebilcock","8189665072","katie.trebilcock@abbott.com",[57],{"facility":58,"status":11,"city":59,"state":60,"zip":61,"country":62,"countryCode":63,"cosmosGeoPoint":64,"geoPoint":69,"contacts":70},"Hightower Clinical","Oklahoma City","Oklahoma","73102","United States","US",{"type":65,"coordinates":66},"Point",[67,68],-97.51643,35.46756,{"lat":68,"lon":67},[71],{"name":72,"role":49,"phone":73,"phoneExt":11,"email":74},"Monica Lo","501-219-7000","mdsherbet@gmail.com",{"type":76,"investigatorFullName":11,"investigatorTitle":11,"investigatorAffiliation":11,"oldNameTitle":11,"oldOrganization":11},"SPONSOR","100666509","investigation-of-post-market-volt-pfa-insights-into-therapy-effectiveness-and-safety-in-atrial-fibrillation-100666509",false,"NCT07954999","InvestiGatioN of Post Market Volt PFA: Insights Into Therapy Effectiveness and Safety in Atrial Fibrillation","IGNITE AF","Inclusion Criteria:\n\n* Documented symptomatic PAF or PersAF. Documentation requirements are as follows:\n\nParoxysmal:\n\n• Physician's note indicating recurrent self-terminating AF AND\n\n• One electrocardiographically documented PAF episode within 12 months prior to enrollment.\n\nPersistent: Continuous AF sustained beyond 7 days and less than 1 year that is documented by • Physician's note, AND either\n\n• 24-hour Holter within 12 months prior to enrollment, showing continuous AF, OR\n\n•\n\nTwo electrocardiograms (from any form of rhythm monitoring) showing continuous AF:\n\no That are taken at least 7 days apart but less than 12 months apart o If electrograms are more than 12 months apart, there must be one or more Sinus Rhythm recordings in between or within 12 months prior to consent\u002Fenrollment o The most recent electrocardiogram must be within 180 days of enrollment. NOTE: Documented evidence of the AF episode must either be continuous AF on a 12-lead ECG or include at least 30 seconds of AF from another ECG device.\n\n2\\. Planning to undergo PVI with the Volt PFA System 3. Refractory, intolerant, or contraindicated to at least one Class I-IV AAD medication 4. At least 21 years of age 5. Able and willing to comply with all trial requirements including pre-procedure, post- procedure, and follow-up testing and requirements 6. Informed of the nature of the trial, agreed to its provisions, and has provided written informed consent as approved by the Institutional Review Board\u002FEthics Committee (IRB\u002FEC) of the respective clinical trial site.\n\nExclusion Criteria:\n\nArrhythmia due to reversible causes including thyroid disorders, acute alcohol intoxication, electrolyte imbalance, severe untreated sleep apnea, and other major surgical procedures in the preceding 90 days 2. Known presence of cardiac thrombus 3. Left ventricular ejection fraction \\\u003C 35% within 365 days of index procedure 4. Stroke or TIA (transient ischemic attack) within the last 90 days 5. Myocardial infarction (MI), acute coronary syndrome, percutaneous coronary intervention (PCI), or valve or coronary bypass grafting surgery within preceding 90 days 6. Severe pulmonary disease (e.g., restrictive pulmonary disease, constrictive or chronic obstructive pulmonary disease requiring permanent inhaler therapy or oxygen) or any other disease or malfunction of the lungs or respiratory system that produces severe chronic symptoms 7. Severe mitral regurgitation (regurgitant volume ≥ 60 mL\u002Fbeat, regurgitant fraction ≥ 50%, and\u002For effective regurgitant orifice area ≥ 0.40cm2).\n\n8\\. Patients who have had a ventriculotomy or atriotomy within the preceding 4 weeks of procedure 9. Patients with prosthetic valves 10. Active systemic infection 11. Patients with a myxoma 12. Patient unable to receive heparin or an acceptable alternative to achieve adequate anticoagulation 13. Patients with an interatrial baffle or patch Pregnant or nursing at the time of the ablation procedure or planning to become pregnant prior to the ablation procedure 15. Patient is currently participating in another clinical study without pre-approval from the Sponsor of this study 16. Unlikely to survive the protocol follow up period of 36 months 17. Presence of other medical, anatomic, comorbid, social, or psychological conditions that, in the investigator's opinion, could limit the subject's ability to participate in the clinical investigation or to comply with follow-up requirements, or impact the scientific soundness of the clinical investigation results 18. Individuals without legal authority 19. Individuals unable to read or write\n\n\\-","ALL","18 Years",{"count":87,"type":88},250,"ESTIMATED","INTERVENTIONAL",[21],"Demonstrate safety and effectiveness of the Volt Pulse Field Ablation System for treating recurrent Paroxysmal Atrial Fibrillation and Persistent Atrial Fibrillation.",[93,94,95],"Atrial Fibrillation (AF)","Paroxysmal AF","Persistent Atrial Fibrillation",[97,95,94],"Atrial Fibrillation","NOT_YET_RECRUITING","2026-11-19",{"date":101,"type":102},"2026-11-24","ACTUAL",{"date":104,"type":88},"2026-12-31",{"date":106,"type":88},"2030-06-30",{"name":5,"class":6},1]