[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100659898":3},{"organization":4,"outcomesModule":7,"designInfo":27,"detailedDescription":28,"studyPopulation":31,"armGroups":28,"interventions":32,"overallOfficials":38,"centralContacts":43,"locations":52,"responsibleParty":69,"collaborators":28,"id":71,"slug":72,"hasResults":73,"nctId":74,"briefTitle":75,"officialTitle":76,"acronym":77,"eligibilityCriteria":78,"healthyVolunteers":73,"sex":79,"minAge":80,"maxAge":28,"enrollmentInfo":81,"targetDuration":28,"studyType":84,"phases":28,"briefSummary":85,"conditions":86,"keywords":28,"overallStatus":54,"whyStopped":28,"lastUpdateSubmitDate":88,"lastUpdatePostDateStruct":89,"startDateStruct":92,"completionDateStruct":94,"leadSponsor":96,"locationsCount":97},{"fullName":5,"class":6},"Medical University of Graz","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":23},[9],{"measure":10,"description":11,"timeFrame":12},"Mean arterial pressure measurement Agreement between IBP and NIBP","Measurement agreement in mean arterial pressure between intraarterial (reference test) and intermittent non-invasive oscillometric (index test) blood pressure monitoring in high-risk patients having induction of anesthesia.","In the first five minutes after induction of anesthesia.",[14,17,20],{"measure":15,"description":16,"timeFrame":12},"Diastolic arterial pressure measurement agreement between IBP and NIBP","Measurement agreement of diastolic arterial pressure between intraarterial (reference test) and intermittent non-invasive oscillometric (index test) blood pressure monitoring in high-risk patients having induction of anesthesia.",{"measure":18,"description":19,"timeFrame":12},"Systolic arterial pressure measurement Agreement between IBP and NIBP","Measurement agreement of systolic arterial pressure between intraarterial (reference test) and intermittent non-invasive oscillometric (index test) blood pressure monitoring in high-risk patients having induction of anesthesia.\n\nTime Frame: In the first five minutes after induction of anesthesia",{"measure":21,"description":22,"timeFrame":12},"Characteristics associated with disagreement between IBP and NIBP","Patient and\u002For treatment characteristics associated with pairwise disagreement (\\>10 mmHg) between intraarterial (clinical reference) and intermittent non-invasive oscillometric (index test) blood pressure monitoring in high-risk patients having induction of anesthesia.",[24],{"measure":25,"description":26,"timeFrame":12},"Subgroup Analysis in patients with severe blood pressure changes","In a predefined subgroup analysis, the primary aim and secondary aims 1 and 2 will be evaluated in situations with severe blood pressure changes (a change ≥ 50 mmHg within one minute).",{"allocation":28,"interventionModel":28,"interventionModelDescription":28,"primaryPurpose":28,"observationalModel":29,"timePerspective":30,"maskingInfo":28},null,"COHORT","PROSPECTIVE","Adults patients with a high-risk of hemodynamic changes during induction of anesthesia undergoing general anesthesia induction with clinically indicated intraarterial blood pressure monitoring before induction.",[33],{"type":6,"name":34,"description":35,"armGroupLabels":28,"otherNames":36},"non-invasive oscillometric blood pressure monitoring","In addition to intraarterial blood pressure monitoring, non-invasive oscillometric blood pressure monitoring will be performed on the contralateral arm.",[37],"NIBP",[39],{"name":40,"affiliation":41,"role":42},"Michael Eichlseder, MD PhD","Medical University of Graz, Department of Anaesthesiology and Intensive Care Medicine","PRINCIPAL_INVESTIGATOR",[44,48],{"name":40,"role":45,"phone":46,"phoneExt":28,"email":47},"CONTACT","+43 316 385 81919","michael.eichlseder@medunigraz.at",{"name":49,"role":45,"phone":50,"phoneExt":28,"email":51},"Nikolaus Schreiber, MD PhD","+43 316 385 81917","nikolaus.schreiber@medunigraz.at",[53],{"facility":41,"status":54,"city":55,"state":56,"zip":57,"country":58,"countryCode":59,"cosmosGeoPoint":60,"geoPoint":65,"contacts":66},"RECRUITING","Graz","Styria","8010","Austria","AT",{"type":61,"coordinates":62},"Point",[63,64],15.44197,47.06733,{"lat":64,"lon":63},[67,68],{"name":40,"role":45,"phone":46,"phoneExt":28,"email":47},{"name":49,"role":45,"phone":50,"phoneExt":28,"email":28},{"type":70,"investigatorFullName":28,"investigatorTitle":28,"investigatorAffiliation":28,"oldNameTitle":28,"oldOrganization":28},"SPONSOR","100659898","measurement-agreement-between-ibp-and-nibp-during-induction-of-anesthesia-in-high-risk-patients-100659898",false,"NCT07870356","Measurement Agreement Between IBP and NIBP During Induction of Anesthesia in High Risk Patients","Measurement Agreement Between Intraarterial (IBP) and Intermittent Non-Invasive Blood Pressure (NIBP) Monitoring During Induction of Anesthesia in High Risk Patients: The AGREE-BP Prospective Observational Study","AGREE-BP","Inclusion Criteria:\n\n1. Intraarterial blood pressure monitoring prior to induction of anesthesia is necessary for clinical reasons\n2. Surgery under general anesthesia\n3. Provision of written informed consent\n4. Less than a 5 mmHg difference between consecutive non-invasive oscillometric blood pressure measurements on the left and right arms\n5. Supine positioning during induction of anesthesia possible and used for clinical reasons.\n6. At least one of the following factors indicating high-risk of blood pressure changes during induction of anesthesia:\n\n   1. Peripheral arterial disease\n   2. Carotid artery disease\n   3. Severe coronary artery disease\n   4. Arterial hypertension requiring three or more antihypertensive agents\n\nExclusion Criteria:\n\n1. Inability to insert the intraarterial catheter and venous catheter on the same arm (mandatory to be on the contralateral side of the non-invasive oscillometric measurement)\n2. Pregnancy\n3. Planned awake fiberoptic intubation\n4. Previous enrollment in the study","ALL","18 Years",{"count":82,"type":83},120,"ESTIMATED","OBSERVATIONAL","The AGREE-BP study aims to evaluate how closely blood pressure measurements taken with an automated upper-arm cuff agree with measurements taken through a small plastic tube placed in an artery, called an arterial catheter, during the start of general anesthesia.\n\nBlood pressure can change rapidly when patients receive medication to induce general anesthesia. These changes may be particularly pronounced in patients with heart or blood vessel disease or high blood pressure. An upper-arm cuff measures blood pressure at intervals, whereas an arterial catheter measures it continuously with each heartbeat. Although cuff measurements are widely used, their agreement with arterial catheter measurements during this period of rapid change is not fully evaluated and validated.\n\nThis observational study will include 120 patients undergoing surgery under general anesthesia at University Hospital Graz, Austria. Participants will have conditions that increase their risk of blood pressure changes and will already require an arterial catheter before anesthesia for medical reasons.\n\nDuring the first five minutes after administration of the medication used to induce anesthesia, researchers will record blood pressure using both methods. The cuff will be placed on the arm opposite the arterial catheter and will take measurements at least once per minute, or more frequently if the monitor allows. Anesthesia and treatment decisions will remain the responsibility of the treating clinician. Participation does not require additional follow-up visits.\n\nThe main aim is to assess agreement in mean arterial pressure, which is the average pressure in the arteries over a heartbeat. Researchers will also compare systolic pressure, the pressure when the heart contracts, and diastolic pressure, the pressure when the heart relaxes. They will examine whether patient characteristics or treatments are associated with differences between the two measurement methods and will separately assess agreement during particularly large, rapid blood pressure changes.\n\nThe findings may help clinicians understand when cuff measurements differ meaningfully from arterial catheter measurements and inform future decisions about blood pressure monitoring during the start of anesthesia.",[87],"Blood Pressure Monitoring","2026-10-21",{"date":90,"type":91},"2026-10-22","ACTUAL",{"date":93,"type":91},"2026-10-07",{"date":95,"type":83},"2027-10",{"name":5,"class":6},1]