[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100661934":3},{"organization":4,"outcomesModule":7,"designInfo":51,"detailedDescription":54,"studyPopulation":54,"armGroups":58,"interventions":65,"overallOfficials":71,"centralContacts":76,"locations":82,"responsibleParty":168,"collaborators":54,"id":170,"slug":171,"hasResults":172,"nctId":173,"briefTitle":174,"officialTitle":174,"acronym":175,"eligibilityCriteria":176,"healthyVolunteers":172,"sex":177,"minAge":178,"maxAge":54,"enrollmentInfo":179,"targetDuration":54,"studyType":182,"phases":183,"briefSummary":184,"conditions":185,"keywords":187,"overallStatus":129,"whyStopped":54,"lastUpdateSubmitDate":192,"lastUpdatePostDateStruct":193,"startDateStruct":196,"completionDateStruct":197,"leadSponsor":199,"locationsCount":200},{"fullName":5,"class":6},"MED-EL Elektromedizinische Geräte GmbH","INDUSTRY",{"primaryOutcomes":8,"secondaryOutcomes":16,"otherOutcomes":33},[9,13],{"measure":10,"description":11,"timeFrame":12},"Word Test in Quiet","Word recognition in quiet, on a scale from 0 to 100% correct, higher scores indicate better outcomes","Pre-op to 6 months after first fitting",{"measure":14,"description":15,"timeFrame":12},"Sentence Test in Noise","Oldenburg Matrix Test, results measured in dB signal-to-noise ratio (SNR) with a range of +30 to -10 dB SNR, lower values indicating better outcomes",[17,20,23,27,30],{"measure":18,"description":19,"timeFrame":12},"Health Utility Index Mark 3 (HUI3)","Health utility scale:\n\n1.00: Perfect health. 0.00: Death. Negative values: States worse than death.",{"measure":21,"description":22,"timeFrame":12},"Nijmegen Cochlear Implant Questionnaire (NCIQ)","Disease specific Quality of Life, overall score is on a scale from 0 to 100, higher numbers indicating better outcomes",{"measure":24,"description":25,"timeFrame":26},"Change in body sound perception","Participant reported scale on body sound perception (0 - no disturbance to 10 - very disturbing)","through study completion, an average of 12 months after first fitting",{"measure":28,"description":29,"timeFrame":26},"Change in stigma perception","Participant reported scale on stigma perception (0 - no stigmatization to 10 - strong stigmatization)",{"measure":31,"description":32,"timeFrame":26},"Change in comfort perception","Participant reported scale on stigma perception (0 - not comfortable to 10 - very comfortable)",[34,36,37,38,39,42,45,48],{"measure":35,"description":11,"timeFrame":26},"Word test in quiet",{"measure":14,"description":15,"timeFrame":26},{"measure":18,"description":19,"timeFrame":26},{"measure":21,"description":22,"timeFrame":26},{"measure":40,"description":41,"timeFrame":26},"Speech, Spatial, Quality of Hearing (SSQ12)","Speech, Spatial and Quality of hearing scale from 0 to 10, higher numbers indicating better outcomes",{"measure":43,"description":44,"timeFrame":26},"Hearing Implant Sound Quality Index (HISQUI)","Sound quality score ranging from 19 (very poor sound quality) to 133 (very good sound quality)",{"measure":46,"description":47,"timeFrame":26},"Tinnitus Functional Index (TFI)","Tinnitus questionnaire measures the severity and negative impact of tinnitus on a 0 (Not a Problem \u002F Slight Tinnitus) to 100 (Very Big Problem \u002F Very Severe Tinnitus) scale",{"measure":49,"description":50,"timeFrame":26},"Audiogram","Pure-tone air-conduction hearing thresholds will be measured in each ear. The threshold is the lowest sound level, in decibels hearing level (dB HL), at which the participant responds. The outcome is the threshold at each frequency. Higher thresholds mean poorer hearing; lower thresholds better hearing.",{"allocation":52,"interventionModel":53,"interventionModelDescription":54,"primaryPurpose":55,"observationalModel":54,"timePerspective":54,"maskingInfo":56},"NA","SINGLE_GROUP",null,"TREATMENT",{"masking":57,"maskingDescription":54,"whoMasked":54},"NONE",[59],{"label":60,"type":61,"description":62,"interventionNames":63},"TICI recipients","EXPERIMENTAL","Participants in this clinical investigation will be implanted with an Mi2000 TICI totally cochlear implant",[64],"Device: Cochlear Implantation",[66],{"type":67,"name":68,"description":69,"armGroupLabels":70,"otherNames":54},"DEVICE","Cochlear Implantation","Participants in this clinical investigation will receive a totally implantable cochlear implant.",[60],[72],{"name":73,"affiliation":74,"role":75},"Florian Schwarze","MED-EL","STUDY_DIRECTOR",[77],{"name":78,"role":79,"phone":80,"phoneExt":54,"email":81},"Florian Schwarze, PhD","CONTACT","+4357788","studies@medel.com",[83,101,115,127,143,154],{"facility":84,"status":85,"city":86,"state":87,"zip":88,"country":89,"countryCode":90,"cosmosGeoPoint":91,"geoPoint":96,"contacts":97},"AKH Wien","NOT_YET_RECRUITING","Vienna","State of Vienna","1090","Austria","AT",{"type":92,"coordinates":93},"Point",[94,95],16.37208,48.20849,{"lat":95,"lon":94},[98],{"name":99,"role":79,"phone":54,"phoneExt":54,"email":100},"Christoph Arnoldner, Prof. Dr.","christoph.arnoldner@meduniwien.ac.at",{"facility":102,"status":85,"city":103,"state":104,"zip":105,"country":104,"countryCode":106,"cosmosGeoPoint":107,"geoPoint":111,"contacts":112},"UZA Antwerpen","Antwerp","Belgium","2650","BE",{"type":92,"coordinates":108},[109,110],4.40026,51.22047,{"lat":110,"lon":109},[113],{"name":114,"role":79,"phone":54,"phoneExt":54,"email":54},"Vincent van Rompaey, Prof. Dr.",{"facility":116,"status":85,"city":117,"state":54,"zip":118,"country":104,"countryCode":106,"cosmosGeoPoint":119,"geoPoint":123,"contacts":124},"Centre Hospitalier Universitaire de Liège, Department ORL","Liège","4000",{"type":92,"coordinates":120},[121,122],5.56749,50.63373,{"lat":122,"lon":121},[125],{"name":126,"role":79,"phone":54,"phoneExt":54,"email":54},"Philippe Lefebvre, Dr.med.",{"facility":128,"status":129,"city":130,"state":131,"zip":132,"country":133,"countryCode":134,"cosmosGeoPoint":135,"geoPoint":139,"contacts":140},"Klinikum der Universität München, Campus Großhadern","RECRUITING","München","Bavaria","81377","Germany","DE",{"type":92,"coordinates":136},[137,138],13.46314,48.69668,{"lat":138,"lon":137},[141],{"name":142,"role":79,"phone":54,"phoneExt":54,"email":54},"Joachim Müller, Dr.med.",{"facility":144,"status":85,"city":145,"state":54,"zip":54,"country":133,"countryCode":134,"cosmosGeoPoint":146,"geoPoint":150,"contacts":151},"Universitätsklinikum Würzburg","Würzburg",{"type":92,"coordinates":147},[148,149],9.95121,49.79391,{"lat":149,"lon":148},[152],{"name":153,"role":79,"phone":54,"phoneExt":54,"email":54},"Kristen Rak, Prof. Dr.",{"facility":155,"status":85,"city":156,"state":157,"zip":158,"country":157,"countryCode":159,"cosmosGeoPoint":160,"geoPoint":164,"contacts":165},"The Institute of Physiology and Pathology of Hearing","Nadarzyn","Poland","05-830","PL",{"type":92,"coordinates":161},[162,163],20.80776,52.09438,{"lat":163,"lon":162},[166],{"name":167,"role":79,"phone":54,"phoneExt":54,"email":54},"Piotr Skarzynski, Prof. Dr.",{"type":169,"investigatorFullName":54,"investigatorTitle":54,"investigatorAffiliation":54,"oldNameTitle":54,"oldOrganization":54},"SPONSOR","100661934","mi2000-tici---post-market-implantation-study-100661934",false,"NCT07897318","Mi2000 TICI - Post-market Implantation Study","TUPIS","Inclusion Criteria:\n\n* Minimum age of eighteen (18) years at time of enrolment\n* Bilateral sensorineural hearing loss with no or limited benefit from a hearing aid (\\>70 dB HL PTA4(500, 1000, 2000, 4000Hz))\n* Post-lingual onset of deafness\n* No or limited benefit from hearing aids for less than 10 years and an expected benefit from cochlear implantation\n* A maximum score of 50% on a word test in the language of the test center in the ear to be implanted in the best aided condition\n* Fluency in the test language with excellent proficiency, as appropriate to perform speech testing\n* Functional auditory nerve\n* General health condition, psychological and emotional condition deemed compatible with the treatment and tests performed in this study\n* Pre-operative assessment according to the local professional standards\n* Candidate is highly motivated and has realistic expectations about the expected benefit of the implant and shall understand the importance of returning to the implant center for regular speech processor programming, assessment sessions and training\n* Realistic expectations, as deemed appropriate by the implanting surgeon\u002Fimplant board\n* Signed and dated informed consent before the start of any study-specific procedure\n\nExclusion Criteria:\n\n* Lack of compliance with any inclusion criterion\n* Previously having received an implant on the location chosen for placing the cochlear implant\n* Having received a hearing implant from another manufacturer than MED-EL on the contralateral ear\n* Pre-existing condition known to necessitate MRI scans after implantation of the Mi2000 TICI\n* Women being pregnant or nursing\n* The individual is known to be intolerant of the materials used in the implant or other required accessories\n* Absence of cochlear development\n* The cause of deafness is non-functionality of the auditory nerve and\u002For the upper auditory pathway\n* Medical contra-indications to middle ear and\u002For inner ear surgery, and\u002For anesthesia\n* External or middle ear infections are present\n* The tympanic membrane is perforated in the ear to be implanted\n* Anatomic abnormalities are present that would prevent appropriate placement of the stimulator housing in the bone of the skull, or prevent placement of the chosen electrode array into the cochlea (including ossification of the cochlea)\n* The psychological status of the individual is unstable\n* The individual has unrealistic expectations\n* Acute cholesteatoma\n* History of vestibular schwannoma\n* Unstable Meniere's disease\n* Auditory Neuropathy\n* Epilepsy not responding to treatment\n* Permanent inability and\u002For unwillingness to participation in post-operative care and rehabilitation\n* Known intellectual disability and\u002For psychological diseases\n* Participation in other pharmacological clinical trials within four weeks prior to enrolment\n* Anything that, in the opinion of the Investigator, would\n\n  * place the subject at increased risk\n  * preclude the subject's full compliance with or completion of the study","ALL","18 Years",{"count":180,"type":181},22,"ESTIMATED","INTERVENTIONAL",[52],"This Post-Market Clinical Follow-up (PMCF) investigation aims to further collect evidence on safety and performance of the Mi2000 TICI. This PMCF investigation will prospectively collect clinical data from the use of the Mi2000 TICI and related devices.\n\nThis PMCF investigation is performed on a cochlear implant system newly introduced to the market, which was previously studied in two pre-market clinical investigations. The purpose of the current clinical investigation is to collect further evidence by collecting additional clinical data on the use of the Mi2000 TICI.",[186,68],"Hearing Loss, Binaural",[188,189,190,191],"Cochlear Implant","Totally Implantable Cochlear Implant","TICI","Fully Implantable Cochlear Implant","2026-11-11",{"date":194,"type":195},"2026-11-12","ACTUAL",{"date":192,"type":195},{"date":198,"type":181},"2029-01",{"name":5,"class":6},6]