[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100663770":3},{"organization":4,"outcomesModule":7,"designInfo":31,"detailedDescription":38,"studyPopulation":30,"armGroups":39,"interventions":46,"overallOfficials":30,"centralContacts":53,"locations":63,"responsibleParty":90,"collaborators":94,"id":102,"slug":103,"hasResults":104,"nctId":105,"briefTitle":106,"officialTitle":107,"acronym":30,"eligibilityCriteria":108,"healthyVolunteers":109,"sex":110,"minAge":111,"maxAge":30,"enrollmentInfo":112,"targetDuration":30,"studyType":115,"phases":116,"briefSummary":117,"conditions":118,"keywords":120,"overallStatus":129,"whyStopped":30,"lastUpdateSubmitDate":130,"lastUpdatePostDateStruct":131,"startDateStruct":134,"completionDateStruct":136,"leadSponsor":138,"locationsCount":139},{"fullName":5,"class":6},"Universidade Federal do Paraná","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":30},[9],{"measure":10,"description":11,"timeFrame":12},"EEG Theta\u002FBeta Ratio as a Neurophysiological Marker of Cognitive Load","Change in the theta\u002Fbeta spectral power ratio derived from 6-channel electroencephalography (EEG) recordings during motor imagery (imagined hand movement) tasks. The theta\u002Fbeta ratio is a validated neurophysiological indicator of cognitive workload and mental effort. This measure is compared across the three distinct device sensitivity levels (low, medium, high) to assess differences in cognitive demand.","Measured continuously during each 10-minute experimental block (blocks 1, 2, and 3) throughout the single 35-minute session.",[14,18,22,26],{"measure":15,"description":16,"timeFrame":17},"NASA Task Load Index (NASA-TLX) Global Workload Score","Subjective assessment of perceived mental workload using the NASA-TLX questionnaire. The instrument evaluates six dimensions: mental demand, physical demand, temporal demand, performance, effort, and frustration. The global workload score ranges from 0 to 100, with higher scores indicating greater perceived workload.","Immediately after each sensitivity block (3 times total) during the experimental session.",{"measure":19,"description":20,"timeFrame":21},"User Experience Questionnaire (UEQ) Scores","Assessment of user experience using the standardized User Experience Questionnaire (UEQ). The instrument measures six scales: Attractiveness, Perspicuity, Efficiency, Dependability, Stimulation, and Novelty. Each scale ranges from -3 (very negative) to +3 (very positive), with higher scores indicating a more favorable user experience.","At the end of the entire experimental session.",{"measure":23,"description":24,"timeFrame":25},"Qualitative Feedback on BCI Physical Interface and Overall Experience","Thematic content analysis of responses collected through a semi-structured qualitative interview consisting of open-ended questions and visual thematic cards. The analysis captures nuanced perceptions regarding the physical interface (EEG cap and robotic glove), comfort, emotional engagement, usability, and suggestions for device improvement.","Immediately following the conclusion of the experimental session.",{"measure":27,"description":28,"timeFrame":29},"Individual Operational Sensitivity Thresholds","Identification of the optimal sensitivity level (low, medium, or high) for each participant based on the calibration phase and successful device triggering during motor imagery tasks. This measure assesses how individual neural signal characteristics influence the optimal threshold for reliable BCI operation.","During the calibration phase and across all three experimental blocks within the session.",null,{"allocation":32,"interventionModel":33,"interventionModelDescription":34,"primaryPurpose":35,"observationalModel":30,"timePerspective":30,"maskingInfo":36},"NA","SINGLE_GROUP","All participants are assigned to a single group and undergo the same experimental protocol. Each participant interacts with the Exobots BCI device across three distinct sensitivity levels (low, medium, high), presented in a counterbalanced order to minimize order effects. The intervention consists of motor imagery tasks with EEG recording and robotic glove assistance.","BASIC_SCIENCE",{"masking":37,"maskingDescription":30,"whoMasked":30},"NONE","Background and Rationale\n\nBrain-Computer Interfaces (BCIs) are increasingly employed in neurorehabilitation settings to assist individuals with motor impairments. While these systems enable direct neural control of assistive devices, there is a significant gap in understanding the cognitive demands they impose on users. Excessive mental workload can lead to frustration, disengagement, and suboptimal therapeutic outcomes. This study addresses this gap by applying a neuroergonomic approach-integrating objective neurophysiological measures with subjective user experience (UX) assessments.\n\nObjectives\n\nPrimary Objective: To evaluate cognitive load during interaction with the Exobots BCI device by integrating neurophysiological metrics (EEG), psychometric UX scores, and subjective user perceptions.\n\nSecondary Objectives:\n\n1. To map neural activity patterns, focusing on theta, alpha, and beta frequency bands, during BCI interaction.\n2. To correlate neurophysiological indicators of mental effort with usability and UX measures obtained via the NASA-TLX and UEQ.\n3. To identify preliminary operational sensitivity threshold parameters established during individual device calibration.\n4. To analyze participants' subjective perceptions of the physical BCI interface using a semi-structured questionnaire with open-ended questions and visual cards.\n5. To formulate technical recommendations for BCI interface design based on the integrated analysis of neurophysiological, psychometric, and qualitative data.\n\nStudy Design\n\nThis is an interventional, single-group, experimental study without a control arm. All participants will undergo the same protocol, testing three distinct sensitivity levels (low, medium, high) in a within-subjects design, with the order of sensitivity levels counterbalanced to avoid order effects.\n\nStudy Population and Sample Size\n\nHealthy adults (aged 18 years or older) who are students (undergraduate, graduate, technical level) or staff members from the Federal University of Paraná (UFPR) and the Federal Institute of Paraná (IFPR) will be recruited.\n\nThe minimum sample size was calculated using G\\*Power software (version 3.1.9.7) for a bivariate normal correlation model (Exact test, Family: Correlation). Considering an expected effect size of r = 0.50, a significance level of α = 0.05, and a statistical power of (1-β) = 0.80, the calculation indicated a minimum of 29 participants. To ensure statistical robustness and account for potential data loss due to EEG artifacts or voluntary dropouts, the target enrollment is set at 30 participants, with recruitment extended to up to 60 individuals if necessary.\n\nIntervention and Procedures\n\nScreening and Consent: Interested individuals will receive and sign the Informed Consent Form (TCLE). A screening questionnaire will be administered to verify inclusion\u002Fexclusion criteria (e.g., no neurological disorders, no recent head injuries).\n\nDevice and Preparation: Participants will interact with the Exobots device (provided by Neurobots). An elastic cap equipped with six dry\u002Fwet EEG electrodes will be placed on the participant's scalp. A water-based conductive gel will be applied to the contact points to ensure optimal signal quality. The robotic glove will be fitted to the participant's hand.\n\nCalibration: The system will be calibrated to recognize each participant's specific neural patterns. Based on the calibration, three distinct sensitivity thresholds (low, medium, high) will be defined and tested individually.\n\nExperimental Protocol: Each participant will complete a sequence of repeated cycles consisting of four sequential steps:\n\nPrepare: The participant focuses attention on their hand in anticipation of the command.\n\nThink: The participant imagines opening\u002Fclosing their hand without physically executing the movement. The EEG system detects the motor imagery signal. If the signal is maintained above the predetermined threshold for three consecutive seconds, the robotic glove is activated.\n\nMove: The robotic glove passively moves the participant's hand. The participant is instructed to voluntarily accompany this movement if possible.\n\nRelax: The participant stops focusing and rests for a few seconds before the next cycle.\n\nEach sensitivity level will be tested in blocks of approximately 10 minutes, totaling approximately 35 minutes of effective interaction per participant. Sessions will be scheduled in advance, with at least 48 hours' notice.\n\nOutcome Measures\n\nNeurophysiological: Continuous 6-channel EEG recording throughout the task. Spectral power analysis will focus on theta (4-8 Hz), alpha (8-12 Hz), and beta (12-30 Hz) bands, with particular emphasis on the theta\u002Fbeta ratio as a validated marker of cognitive load.\n\nPsychometric: Immediately after each sensitivity block, participants will complete the NASA Task Load Index (NASA-TLX) to assess perceived mental, physical, and temporal demands, effort, and frustration. At the end of the entire session, the User Experience Questionnaire (UEQ) will be administered to evaluate pragmatic and hedonic quality attributes.\n\nQualitative: A semi-structured interview with open-ended questions and thematic cards will be conducted to capture nuanced perceptions regarding the physical interface, comfort, and overall experience that standardized scales may not fully address.\n\nStatistical Analysis\n\nPearson correlation coefficients will be calculated to assess the association between neurophysiological metrics (e.g., theta\u002Fbeta ratio, alpha power) and UX scores (UEQ and NASA-TLX). A significance level of p \\\u003C 0.05 will be adopted. Qualitative data will be analyzed using content analysis techniques to identify recurring themes and insights.\n\nEthical Considerations\n\nThe study protocol was reviewed and approved by the Research Ethics Committee of the Federal Technological University of Paraná (CEP\u002FUTFPR) under Approval Number 8.558.948 (issued July 2, 2026; CAAE: 97426026.1.0000.0165). All procedures comply with Brazilian regulations (Resolution CNS 466\u002F12 and LGPD - Lei Geral de Proteção de Dados).\n\nParticipants will be informed that no direct clinical benefits are expected, but that their participation will contribute to the scientific advancement of assistive technologies. Risks are minimal and include mild scalp discomfort from the EEG cap\u002Fgel, transient fatigue, or mild frustration. Participants may take breaks or withdraw at any time without penalty. All data will be anonymized, stored on a password-protected local hard drive, and kept confidential.\n\nData Monitoring Committee\n\nA formal Data Monitoring Committee (DMC) will not be established, as this is a low-risk, non-clinical, academic study with healthy volunteers and no investigational drug or device under IDE regulations.",[40],{"label":41,"type":42,"description":43,"interventionNames":44},"Exobots BCI Device","EXPERIMENTAL","Participants perform motor imagery tasks (imagining hand movements) while using the Exobots EEG-based BCI device. The system detects neural signals and activates a robotic glove to assist hand movement. Three distinct sensitivity thresholds (low, medium, high) are tested in a counterbalanced order within a single 35-minute experimental session.",[45],"Other: EEG-Based Brain-Computer Interface Device",[47],{"type":6,"name":48,"description":49,"armGroupLabels":50,"otherNames":51},"EEG-Based Brain-Computer Interface Device","Non-invasive electroencephalography (EEG)-based Brain-Computer Interface (BCI) system consisting of a 6-channel EEG headset and a robotic hand exoskeleton (glove). The device detects motor imagery neural signals associated with imagined hand movements. When the EEG signal is maintained above a predefined sensitivity threshold for three consecutive seconds, the system triggers the robotic glove to passively move the participant's hand. The study evaluates three distinct sensitivity levels (low, medium, high) during individual calibration. The EEG headset uses water-based conductive gel on contact points to ensure signal quality. The device is manufactured by Neurobots and provided for this research.",[41],[52],"Exobots BCI System",[54,59],{"name":55,"role":56,"phone":57,"phoneExt":30,"email":58},"Lucas T dos Santos Vieira","CONTACT","+55 041 998746-9352","lucastadeu1875@gmail.com",{"name":60,"role":56,"phone":61,"phoneExt":30,"email":62},"Henrique C Carvalho","+55 012 999138-3609","hccarvalho@utfpr.edu.br",[64,82],{"facility":65,"status":30,"city":66,"state":67,"zip":68,"country":69,"countryCode":70,"cosmosGeoPoint":71,"geoPoint":76,"contacts":77},"Federal Technological University of Paraná","Curitiba","Paraná","80230901","Brazil","BR",{"type":72,"coordinates":73},"Point",[74,75],-49.27306,-25.42778,{"lat":75,"lon":74},[78,80],{"name":55,"role":56,"phone":79,"phoneExt":30,"email":58},"+55 041 987469362",{"name":60,"role":56,"phone":81,"phoneExt":30,"email":62},"+55 012 9991383609",{"facility":83,"status":30,"city":66,"state":67,"zip":30,"country":69,"countryCode":70,"cosmosGeoPoint":84,"geoPoint":86,"contacts":87},"UFPR",{"type":72,"coordinates":85},[74,75],{"lat":75,"lon":74},[88],{"name":89,"role":56,"phone":79,"phoneExt":30,"email":58},"Lucas Tadeu dos Santos Vieira, Bacharel",{"type":91,"investigatorFullName":92,"investigatorTitle":93,"investigatorAffiliation":5,"oldNameTitle":30,"oldOrganization":30},"PRINCIPAL_INVESTIGATOR","Henrique Cunha Carvalho","PhD",[95,98,100],{"name":96,"class":97},"Instituto Federal do Paraná (IFPR)","UNKNOWN",{"name":99,"class":97},"Universidade Federal do Paraná (UFPR)",{"name":101,"class":97},"Universidade Tecnológica Federal do Paraná (UTFPR)","100663770","neuroergonomic-analysis-of-a-brain-computer-interface-device-bci-100663770",false,"NCT07922265","Neuroergonomic Analysis of a Brain-Computer Interface Device (BCI)","Neuroergonomic Analysis of a Brain-Computer Interface (BCI) Device Based on EEG Signals and User Experience","Inclusion Criteria:\n\n1. Technical-level students, undergraduate students, graduate students, and staff members, of both sexes, healthy, affiliated with the Federal University of Paraná (UFPR) or the Federal Institute of Paraná (IFPR).\n2. Age 18 years or older.\n\nExclusion Criteria:\n\n1. Use of psychoactive medications.\n2. History of epilepsy or other neurological conditions that would preclude the use of the device.\n3. Severe motor limitations that prevent interaction with the device.\n4. Recent traumatic brain injuries.\n5. Injury, dermatitis, or open wound on the scalp.\n6. Excessive consumption of stimulant substances within the last 4 hours.\n7. Sleep deprivation (less than 5 hours of sleep the previous night) or extreme sleepiness on the day of data collection.",true,"ALL","18 Years",{"count":113,"type":114},30,"ESTIMATED","INTERVENTIONAL",[32],"This study evaluates the mental workload and user experience associated with a Brain-Computer Interface (BCI) device called Exobots. The Exobots system uses a non-invasive electroencephalography (EEG) headset to detect neural signals and control a robotic glove that assists hand movement. The primary goal is to assess how three different system sensitivity levels (low, medium, high) impact mental effort, usability, and overall user perception. Healthy adult volunteers (students and staff from IFPR and UFPR) will participate in a single experimental session. During the session, they will perform a repeated mental imagery task (imagine hand movement) while the EEG records their brain activity. After each sensitivity block, participants will complete standardized questionnaires (NASA Task Load Index and User Experience Questionnaire) and a semi-structured qualitative interview about their experience. By combining objective neurophysiological data with subjective feedback, this research aims to identify optimal sensitivity thresholds that minimize cognitive strain and maximize user comfort. The findings are expected to provide technical recommendations for designing more adaptive, user-centered BCI systems for future neurorehabilitation applications.",[119],"Healthy Volunteers - Male and Female",[121,122,123,124,125,126,127,128],"Brain-Computer Interface","BCI","Electroencephalography","Mental Workload","Motor Imagery","NASA-TLX","UEQ","Human Factors","NOT_YET_RECRUITING","2026-11-02",{"date":132,"type":133},"2026-11-06","ACTUAL",{"date":135,"type":114},"2026-12-28",{"date":137,"type":114},"2027-03-31",{"name":5,"class":6},2]