[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100666683":3},{"organization":4,"outcomesModule":7,"designInfo":24,"detailedDescription":27,"studyPopulation":28,"armGroups":29,"interventions":23,"overallOfficials":42,"centralContacts":47,"locations":23,"responsibleParty":53,"collaborators":23,"id":55,"slug":56,"hasResults":57,"nctId":58,"briefTitle":59,"officialTitle":60,"acronym":61,"eligibilityCriteria":62,"healthyVolunteers":63,"sex":64,"minAge":65,"maxAge":23,"enrollmentInfo":66,"targetDuration":23,"studyType":69,"phases":23,"briefSummary":70,"conditions":71,"keywords":74,"overallStatus":79,"whyStopped":23,"lastUpdateSubmitDate":80,"lastUpdatePostDateStruct":81,"startDateStruct":84,"completionDateStruct":86,"leadSponsor":88,"locationsCount":23},{"fullName":5,"class":6},"IRCCS San Raffaele","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":23},[9],{"measure":10,"description":11,"timeFrame":12},"CMT","central macular thickness","From January 2016 to January 2026",[14,17,20],{"measure":15,"description":16,"timeFrame":12},"HF","hyperreflective foci",{"measure":18,"description":19,"timeFrame":12},"SRF","subretinal fluid",{"measure":21,"description":22,"timeFrame":12},"IRF","intraretinal fluid",null,{"allocation":23,"interventionModel":23,"interventionModelDescription":23,"primaryPurpose":23,"observationalModel":25,"timePerspective":26,"maskingInfo":23},"COHORT","RETROSPECTIVE","This study aims to evaluate sensitivity and specificity of a new generation AI-based software for the detection of optical coherence tomography (OCT) retinal alterations of retinal vein occlusions (RVO). We will statistically compare the obtained results with the grading of an expert ophthalmologist to test sensitivity and specificity. AI-based tools are establishing as useful support in many retinal diseases, such as age-related macular degeneration and diabetic retinopathy. Retinal vein occlusions represent a major retinal disease, affecting a big number of patients. Most of the used OCT imaging metrics are the same found in age-related macular degeneration and diabetic retinopathy. Hence, a knowledge gap is represented by the sensitivity and specificity of these AI tools for the proper detection of these metrics in RVO.\n\nTrue positive and true negative results are defined as AI-based assessments matching with expert grader analysis (presence or not of the same OCT metrics). The study is designed as retrospective analysis of OCT images acquired during ophthalmologic visits.","Eyes affected by RVO, DR, AMD or healthy controls",[30,33,36,39],{"label":31,"type":23,"description":32,"interventionNames":23},"RVO","Eyes affected by branch or central RVO",{"label":34,"type":23,"description":35,"interventionNames":23},"AMD","Eyes affected by age-related macular degeneration",{"label":37,"type":23,"description":38,"interventionNames":23},"DR","Eyes affected by diabetic retinopathy",{"label":40,"type":23,"description":41,"interventionNames":23},"Healthy","Healthy controls",[43],{"name":44,"affiliation":45,"role":46},"Alessandro Arrigo","IRCCS San Raffaele Scientific Institute, Milan, Italy","PRINCIPAL_INVESTIGATOR",[48],{"name":49,"role":50,"phone":51,"phoneExt":23,"email":52},"Alessandro Arrigo, MD, PhD","CONTACT","+390226433580","arrigo.alessandro@hsr.it",{"type":46,"investigatorFullName":44,"investigatorTitle":54,"investigatorAffiliation":5,"oldNameTitle":23,"oldOrganization":23},"MD, PhD, Head of Imaging Unit, Ophthalmology Department","100666683","new-generation-artificial-intelligence-tool-for-detecting-optical-coherence-tomography-alterations-in-retinal-vein-occlusions-100666683",false,"NCT07959458","New Generation Artificial Intelligence Tool for Detecting Optical Coherence Tomography Alterations in Retinal Vein Occlusions","Testing Sensitivity and Specificity of a New Generation Artificial Intelligence Tool for Detecting Optical Coherence Tomography Alterations in Retinal Vein Occlusions.","AIRVO-2026","Inclusion Criteria:\n\n* • Age ≥ 18 years\n\n  * Both genders\n  * Confirmed diagnosis of one of the diseases described above\n  * Visual acuity of at least 1\u002F20\n  * Informed consent signed for study participation\n  * Women of childbearing age or pregnant may be included.\n\nExclusion Criteria:\n\n* • Media opacities\n\n  * Any other ocular or systemic condition that may irreversibly affect the results of the study\n  * Eye surgery in the study, including cataract extraction, within three months prior to recruitment",true,"ALL","18 Years",{"count":67,"type":68},750,"ESTIMATED","OBSERVATIONAL","This study aims to evaluate sensitivity and specificity of a new generation AI-based software for the detection of optical coherence tomography (OCT) retinal alterations of retinal vein occlusions (RVO). We will statistically compare the obtained results with the grading of an expert ophthalmologist to test sensitivity and specificity.",[72,73],"Retinal Vein Occlusion (RVO)","Retinal Vein Occlusion",[75,76,77,78],"rvo","retinal vein occlusion","oct","artificial intelligence","NOT_YET_RECRUITING","2026-11-21",{"date":82,"type":83},"2026-11-25","ACTUAL",{"date":85,"type":68},"2027-01-07",{"date":87,"type":68},"2028-03-01",{"name":5,"class":6}]