[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100663981":3},{"organization":4,"outcomesModule":7,"designInfo":50,"detailedDescription":49,"studyPopulation":49,"armGroups":56,"interventions":64,"overallOfficials":74,"centralContacts":49,"locations":78,"responsibleParty":98,"collaborators":100,"id":106,"slug":107,"hasResults":108,"nctId":109,"briefTitle":110,"officialTitle":111,"acronym":49,"eligibilityCriteria":112,"healthyVolunteers":108,"sex":113,"minAge":114,"maxAge":115,"enrollmentInfo":116,"targetDuration":49,"studyType":119,"phases":120,"briefSummary":121,"conditions":122,"keywords":124,"overallStatus":81,"whyStopped":49,"lastUpdateSubmitDate":129,"lastUpdatePostDateStruct":130,"startDateStruct":133,"completionDateStruct":135,"leadSponsor":137,"locationsCount":138},{"fullName":5,"class":6},"E-DA Hospital","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":49},[9],{"measure":10,"description":11,"timeFrame":12},"Change in Ring-Derived Apnea-Hypopnea Index (bAHI3)","Change in the ring-derived apnea-hypopnea index (bAHI3, events\u002Fh) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 nightly recordings with the mean of the last 7 nightly recordings.","Baseline (first 7 nights) and end of training (nights 22-28 or last 7 recordings)",[14,18,21,25,28,32,36,40,43,46],{"measure":15,"description":16,"timeFrame":17},"Change in Ring-Derived Apnea-Hypopnea Index Using the 4% Desaturation Criterion (bAHI4)","Ring-derived apnea-hypopnea index using the 4% oxygen desaturation criterion (bAHI4, events\u002Fh) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings.","Baseline (first 7 valid nights) and end of training (last 7 valid nights), 4 weeks",{"measure":19,"description":20,"timeFrame":17},"Change in Ring-Derived Sleep Efficiency","Ring-derived sleep efficiency (%, total sleep time divided by total recording time) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings.",{"measure":22,"description":23,"timeFrame":24},"Change in STOP-Bang Score","STOP-Bang questionnaire score (range 0-8; higher scores indicate higher risk of obstructive sleep apnea), before vs after training.","Baseline and end of 4-week training",{"measure":26,"description":27,"timeFrame":24},"Change in Midsagittal Pharyngeal Airway Area on Supine CT","Midsagittal pharyngeal airway area (mm2), outlined on the midsagittal CT reconstruction from the level of the hard palate to the epiglottis, before vs after training.",{"measure":29,"description":30,"timeFrame":31},"Post-Training Satisfaction Score","Participant-rated satisfaction with the training program on a 0-100 scale (higher scores indicate greater satisfaction).","End of 4-week training",{"measure":33,"description":34,"timeFrame":35},"Adherence: Proportion of Nights With a Valid Ring Recording","Number of nights with a valid ring-type monitor recording divided by the number of scheduled nights, expressed as a percentage.","4 weeks",{"measure":37,"description":38,"timeFrame":39},"Number of Participants With Adverse Events","Adverse events related to electrical stimulation or ring wear (e.g., skin irritation, pain, discomfort), recorded during training and follow-up.","During the 4-week training and up to 90 days of follow-up",{"measure":41,"description":42,"timeFrame":17},"Change in Ring-Derived Oxygen Desaturation Index (ODI)","Ring-derived oxygen desaturation index (events\u002Fh) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings.",{"measure":44,"description":45,"timeFrame":17},"Change in Ring-Derived Sleep-Onset Latency","Ring-derived sleep-onset latency (min) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings.",{"measure":47,"description":48,"timeFrame":17},"Change in Ring-Derived Total Sleep Time","Ring-derived total sleep time (min) measured by a ring-type sleep monitor (Belun Ring BLS-100), comparing the mean of the first 7 valid nightly recordings with the mean of the last 7 valid nightly recordings.",null,{"allocation":51,"interventionModel":52,"interventionModelDescription":49,"primaryPurpose":53,"observationalModel":49,"timePerspective":49,"maskingInfo":54},"NA","SINGLE_GROUP","TREATMENT",{"masking":55,"maskingDescription":49,"whoMasked":49},"NONE",[57],{"label":58,"type":59,"description":60,"interventionNames":61},"Submental NMES with nightly ring monitoring","EXPERIMENTAL","Adults with obstructive sleep apnea perform home-based submental transcutaneous neuromuscular electrical stimulation (30 minutes every evening for 28 consecutive nights) and wear a ring-type sleep monitor every night during and after training.",[62,63],"Device: Submental transcutaneous neuromuscular electrical stimulation (RS-18)","Device: Ring-type sleep monitor (Belun Ring BLS-100)",[65,70],{"type":66,"name":67,"description":68,"armGroupLabels":69,"otherNames":49},"DEVICE","Submental transcutaneous neuromuscular electrical stimulation (RS-18)","Submental transcutaneous neuromuscular electrical stimulation with the RS-18 wireless low-frequency stimulator (Jie-Mai Medical Technology; TFDA license 007859; off-label use). Biphasic symmetrical pulses, 250 us, 30-100 Hz program, intensity self-titrated to a strong but comfortable contraction. One 30-minute session every evening before bedtime for 28 consecutive nights at home, after supervised instruction.",[58],{"type":66,"name":71,"description":72,"armGroupLabels":73,"otherNames":49},"Ring-type sleep monitor (Belun Ring BLS-100)","A ring-type wearable sleep monitor (Belun Ring BLS-100) worn on the finger every night during and after the 4-week training period to record pulse oximetry, heart rate and accelerometry signals for ring-derived apnea-hypopnea index, oxygen desaturation index and sleep parameters. Used for monitoring only; no therapeutic function.",[58],[75],{"name":76,"affiliation":5,"role":77},"Chih-Chun Wang, MD","PRINCIPAL_INVESTIGATOR",[79],{"facility":80,"status":81,"city":82,"state":49,"zip":83,"country":84,"countryCode":85,"cosmosGeoPoint":86,"geoPoint":91,"contacts":92},"E-Da Hospital","RECRUITING","Kaohsiung City","82445","Taiwan","TW",{"type":87,"coordinates":88},"Point",[89,90],120.31333,22.61626,{"lat":90,"lon":89},[93],{"name":94,"role":95,"phone":96,"phoneExt":49,"email":97},"Chih-Chun Wang","CONTACT","+886-988-092-216","CCW5969@yahoo.com.tw",{"type":77,"investigatorFullName":94,"investigatorTitle":99,"investigatorAffiliation":5,"oldNameTitle":49,"oldOrganization":49},"Physician, Department of Otolaryngology-Head and Neck Surgery",[101,103],{"name":102,"class":6},"National Cheng Kung University",{"name":104,"class":105},"Metal Industries Research & Development Centre","UNKNOWN","100663981","nightly-wearable-monitoring-during-home-based-submental-electrical-stimulation-for-obstructive-sleep-apnea-100663981",false,"NCT07921329","Nightly Wearable Monitoring During Home-Based Submental Electrical Stimulation for Obstructive Sleep Apnea","Clinical Testing of a Physiological Signal Detection, Recognition and Feedback System for Obstructive Sleep Apnea: Home-Based Submental Transcutaneous Neuromuscular Electrical Stimulation With Nightly Ring-Type Monitoring","Inclusion Criteria:\n\n* Adults aged 20 to 65 years\n* Obstructive sleep apnea diagnosed by a physician on polysomnography or an equivalent respiratory-event index test with AHI \\>= 5 events\u002Fh (mild 5-14.9, moderate 15-29.9, severe \\>= 30)\n\nExclusion Criteria:\n\n* AHI \\\u003C 5 events\u002Fh\n* Pregnancy\n* Prior nasal CPAP therapy\n* Inflammation, rash, broken skin, swelling or infection at the stimulation site\n* Cardiac disease, pacemaker or other implanted electronic or metallic device\n* Allergic reaction to the device\n* Concurrent use of other wearable medical devices (e.g., insulin pump)\n* Cognitive impairment\n* Suspected or confirmed epilepsy\n* Central pain syndromes including headache","ALL","20 Years","65 Years",{"count":117,"type":118},50,"ESTIMATED","INTERVENTIONAL",[51],"This single-arm pilot study evaluates the feasibility of nightly wearable monitoring with a ring-type sleep monitor during a 4-week home-based program of submental transcutaneous neuromuscular electrical stimulation in adults with obstructive sleep apnea, and describes changes in the ring-derived apnea-hypopnea index, sleep continuity, STOP-Bang score and upper-airway anatomy on CT before and after training.",[123],"Obstructive Sleep Apnea",[125,126,127,128],"neuromuscular electrical stimulation","wearable monitoring","apnea-hypopnea index","obstructive sleep apnea","2026-11-19",{"date":131,"type":132},"2026-11-24","ACTUAL",{"date":134,"type":132},"2025-06-07",{"date":136,"type":118},"2028-01",{"name":5,"class":6},1]