[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100662555":3},{"organization":4,"outcomesModule":7,"designInfo":22,"detailedDescription":31,"studyPopulation":21,"armGroups":32,"interventions":44,"overallOfficials":53,"centralContacts":64,"locations":69,"responsibleParty":82,"collaborators":21,"id":85,"slug":86,"hasResults":87,"nctId":88,"briefTitle":89,"officialTitle":90,"acronym":21,"eligibilityCriteria":91,"healthyVolunteers":87,"sex":92,"minAge":93,"maxAge":94,"enrollmentInfo":95,"targetDuration":21,"studyType":98,"phases":99,"briefSummary":101,"conditions":102,"keywords":104,"overallStatus":72,"whyStopped":21,"lastUpdateSubmitDate":109,"lastUpdatePostDateStruct":110,"startDateStruct":113,"completionDateStruct":115,"leadSponsor":117,"locationsCount":118},{"fullName":5,"class":6},"Cairo University","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":21},[9],{"measure":10,"description":11,"timeFrame":12},"Bone density","Bone mineral density recovery at the fracture site, will be analyzed using Hounsfield Units (HU).","Patients will undergo multi-slice CT scanning at baseline (within 1 week) and at 6 months postoperatively to assess the recovery.",[14,18],{"measure":15,"description":16,"timeFrame":17},"Postoperative occlusion","Number of participants achieving a satisfactory occlusion, defined as meeting three criteria simultaneously: dental midline deviation ≤ 1 mm, bilateral normal canine relationship, and bilateral normal molar relationship. Failure in any criterion is classified as unsatisfactory.","One week postoperatively",{"measure":19,"description":20,"timeFrame":17},"Incidence of Postoperative Neurosensory Dysfunction","The number of participants who develop neurosensory dysfunction. Sensation is evaluated using the Two-Point Discrimination (2PD) test. Neurosensory dysfunction is defined as a binary categorical outcome where a participant fails to distinguish two distinct points at the standard clinical threshold (≤ 5 mm). Participants who require a distance greater than 5 mm to discriminate the two points are marked as having neurosensory dysfunction.",null,{"allocation":23,"interventionModel":24,"interventionModelDescription":21,"primaryPurpose":25,"observationalModel":21,"timePerspective":21,"maskingInfo":26},"RANDOMIZED","PARALLEL","TREATMENT",{"masking":27,"maskingDescription":28,"whoMasked":29},"SINGLE","This is a single-blind clinical trial where only the participant is blinded. Due to the distinct differences in the geometric design, and radiographic appearance of the patient-specific plates versus conventional plates on computed tomography (CT) scans, it is impossible to mask the operating surgeon or the radiological outcome assessor.",[30],"PARTICIPANT","This parallel-group, randomized controlled clinical trial evaluates the efficacy of patient-specific (custom-designed) fixation plates compared to conventional plates regarding bone mineral density recovery in mandibular body fractures.\n\nUpon consenting to participate, eligible patients requiring open reduction and internal fixation (ORIF) for mandibular body fractures will be randomly assigned to one of two groups:\n\n1. Group I (Intervention): Patients will receive patient-specific titanium plates pre-fabricated utilizing computer-aided design and computer-aided manufacturing (CAD\u002FCAM) based on preoperative 3D computed tomography (CT) data.\n2. Group II (Control): Patients will receive conventional, standard stock titanium plates adapted manually during surgery.\n\nAll surgical procedures will be standardized and performed under general anesthesia by the same surgical team.\n\nRadiological Assessment of Bone Density:\n\nThe primary outcome, bone mineral density recovery at the fracture site, will be analyzed using Hounsfield Units (HU). Patients will undergo multi-slice CT scanning at baseline (within 1 week) and at 6 months postoperatively to assess the recovery.",[33,39],{"label":34,"type":35,"description":36,"interventionNames":37},"Fixation of mandibular body fractures with patient-specific titanium plates.","EXPERIMENTAL","Patients in this group will undergo open reduction and internal fixation (ORIF) using custom-designed titanium plates. The plates are pre-fabricated utilizing computer-aided design and computer-aided manufacturing (CAD\u002FCAM) based on the patient's preoperative 3D computed tomography (CT) data.",[38],"Procedure: Open reduction and Internal fixation of a mandibular body fracture",{"label":40,"type":41,"description":42,"interventionNames":43},"Fixation of mandibular body fractures with conventional plates.","ACTIVE_COMPARATOR","Patients in this group will undergo standard open reduction and internal fixation (ORIF) using commercially available, standard stock titanium plates.",[38],[45,50],{"type":46,"name":47,"description":48,"armGroupLabels":49,"otherNames":21},"PROCEDURE","Open reduction and Internal fixation of a mandibular body fracture","Patient-Specific titanium plates designed using virtual 3D planning software and fabricated via computer-aided manufacturing to match the patient's precise pre-injury mandibular anatomy.",[34],{"type":46,"name":47,"description":51,"armGroupLabels":52,"otherNames":21},"Commercially available, standard stock titanium plates will be adapted and bent manually by the surgeon during the operation to fit the patient's mandibular anatomy.",[40],[54,58,60],{"name":55,"affiliation":56,"role":57},"Rofaida A Abbas, PhD","Associate Professor","STUDY_DIRECTOR",{"name":59,"affiliation":56,"role":57},"Nahla M Awadallah, PhD",{"name":61,"affiliation":62,"role":63},"Dina Y Girgis","Assistant Lecturer","PRINCIPAL_INVESTIGATOR",[65],{"name":61,"role":66,"phone":67,"phoneExt":21,"email":68},"CONTACT","01278061226","dina.yacoub@dentistry.cu.edu.eg",[70],{"facility":71,"status":72,"city":73,"state":74,"zip":75,"country":76,"countryCode":77,"cosmosGeoPoint":21,"geoPoint":21,"contacts":78},"Faculty of Dentistry- Cairo University","RECRUITING","Cairo","Giza Governorate","11553","Egypt","EG",[79,81],{"name":61,"role":66,"phone":80,"phoneExt":21,"email":68},"+201278061226",{"name":61,"role":63,"phone":21,"phoneExt":21,"email":21},{"type":63,"investigatorFullName":83,"investigatorTitle":84,"investigatorAffiliation":5,"oldNameTitle":21,"oldOrganization":21},"Dina Yacoub Girgis","Assistant lecturer","100662555","optimized-osteosynthesis-bone-mineral-density-recovery-in-mandibular-body-fractures-using-patient-specific-versus-conventional-plates-100662555",false,"NCT07904897","Optimized Osteosynthesis: Bone Mineral Density Recovery in Mandibular Body Fractures Using Patient-Specific Versus Conventional Plates","Optimized Osteosynthesis: A Comparative Analysis of Bone Mineral Density Recovery in Mandibular Body Fractures Using Patient-Specific Versus Conventional Plates (A Randomized Controlled Clinical Trial)","Inclusion Criteria:\n\n* Unilateral or bilateral mandibular body fracture requiring open reduction and internal fixation (ORIF), presenting either isolated or concurrently with other maxillofacial, midface, or other mandibular fractures.\n* Patients in good general health who are medically cleared to undergo major maxillofacial surgery under general anesthesia.\n\nExclusion Criteria:\n\n* Presence of comminuted fractures or pre-existing malunions at the fracture site.\n* Patients with high-risk systemic diseases or any medical conditions that contraindicate the administration of general anesthesia.","ALL","18 Years","55 Years",{"count":96,"type":97},26,"ESTIMATED","INTERVENTIONAL",[100],"NA","The goal of this randomized controlled clinical trial is to evaluate and compare the bone mineral density (BMD) recovery following open reduction and internal fixation (ORIF) of mandibular body fractures using patient-specific plates versus conventional plates. Bone density at the fracture site will be quantified using Hounsfield Units (HU) on computed tomography (CT) scans.\n\nThe main question it aims to answer is: Do patient-specific plates provide a superior recovery of bone mineral density at the fracture site compared to conventional plates in patients undergoing fixation for mandibular body fractures?",[103],"Mandibular Fractures",[105,106,107,108],"Mandibular Body Fracture","Patient-Specific Plates","Conventional plates","Bone Mineral Density","2026-10-23",{"date":111,"type":112},"2026-10-29","ACTUAL",{"date":114,"type":112},"2026-10-12",{"date":116,"type":97},"2028-01",{"name":5,"class":6},1]