[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100663162":3},{"organization":4,"outcomesModule":7,"designInfo":67,"detailedDescription":73,"studyPopulation":66,"armGroups":74,"interventions":86,"overallOfficials":66,"centralContacts":96,"locations":66,"responsibleParty":106,"collaborators":110,"id":114,"slug":115,"hasResults":116,"nctId":117,"briefTitle":118,"officialTitle":119,"acronym":66,"eligibilityCriteria":120,"healthyVolunteers":116,"sex":121,"minAge":122,"maxAge":123,"enrollmentInfo":124,"targetDuration":66,"studyType":127,"phases":128,"briefSummary":130,"conditions":131,"keywords":66,"overallStatus":133,"whyStopped":66,"lastUpdateSubmitDate":134,"lastUpdatePostDateStruct":135,"startDateStruct":138,"completionDateStruct":140,"leadSponsor":142,"locationsCount":66},{"fullName":5,"class":6},"Oregon Health and Science University","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":66},[9],{"measure":10,"description":11,"timeFrame":12},"Percent of time with sensed glucose between 70-180 mg\u002Fdl during the daytime","Percent of time with sensed glucose between 70-180 mg\u002Fdl during the daytime (06:00-23:59) comparing the results during the week when participants used the single-hormone insulin-only system (arm 1) versus when participants used the dual-hormone insulin and pramlintide system (arm 2). This outcome can range from 0% to 100% time with sensed glucose between 70-180 mg\u002FdL with a higher percentage indicating better glucose control.","CGM measured during the daytime (06:00-23:59) hours for all days in the week when participants used the single-hormone system compared with all days in the week when participants used the dual-hormone system.",[14,18,22,25,28,31,34,37,40,43,46,49,53,57,60,63],{"measure":15,"description":16,"timeFrame":17},"Incremental area under the sensed glucose curve of in-clinic postprandial glucose","Incremental area under the sensed glucose curve (iAUC) of postprandial glucose as measured by CGM in the 6 hours following the start of standarized in-clinic meal. iAUC (mg\u002FdL\\*min) will be calculated using a trapezoidal method \\[76\\], which sums all CGM values in the 6 hour period following the meal above the starting glucose. This value can range between 0 and 144,000 mg\u002FdL\\*min with a lower iAUC indicating better glucose control. We will compare the results during the week when participants used the single-hormone insulin-only system (arm 1) versus when participants used the dual-hormone insulin and pramlintide system (arm 2).","6 hours following the start of standarized in-clinic meal",{"measure":19,"description":20,"timeFrame":21},"Percent of time with sensed glucose \u003C70 mg\u002Fdl","Percent of time sensed CGM glucose is less than 70 mg\u002FdL comparing the results during the week when participants used the single-hormone insulin-only system (arm 1) versus when participants used the dual-hormone insulin and pramlintide system (arm 2).. This outcome can range from 0 to 100% with a lower value indicating better glucose control.","Daytime (06:00-23:59), overnight (24:00-05:59), and over full 24-hours.",{"measure":23,"description":24,"timeFrame":21},"Percent of time with sensed glucose between 70 - 140 mg\u002Fdl","Percent of time with sensed glucose between 70 - 140 mg\u002Fdl comparing the results during the week when participants used the single-hormone insulin-only system (arm 1) versus when participants used the dual-hormone insulin and pramlintide system (arm 2). This outcome can take values between 0 and 100 with a higher value indicating better glucose control.",{"measure":26,"description":27,"timeFrame":21},"Mean sensed glucose","Mean of the CGM values comparing the results during the week when participants used the single-hormone insulin-only system (arm 1) versus the week when participants used the dual-hormone insulin and pramlintide system (arm 2). This outcome can take values between 40 and 400 mg\u002FdL with a lower value indicating better glucose control.",{"measure":29,"description":30,"timeFrame":21},"Coefficient of variation of sensed glucose","Coefficient of variation of CGM comparing the results during the week when participants used the single-hormone insulin-only system (arm 1) versus the week when participants used the dual-hormone insulin and pramlintide system (arm 2). This outcome can take values between 0 and 100% with a lower value indicating better glucose control.",{"measure":32,"description":33,"timeFrame":21},"Percent of time with sensed glucose \u003C54 mg\u002Fdl","Percent of time that sensed glucose is less than 54 mg\u002FdL comparing the results during the week when participants used the single-hormone insulin-only system (arm 1) versus the week when participants used the dual-hormone insulin and pramlintide system (arm 2). This outcome can take values between 0 and 100% with a lower value indicating better glucose control.",{"measure":35,"description":36,"timeFrame":21},"Percent of time with sensed glucose >180 mg\u002Fdl","Percent of time that sensed glucose is less than 180 mg\u002FdL comparing the results during the week when participants used the single-hormone insulin-only system (arm 1) versus the week when participants used the dual-hormone insulin and pramlintide system (arm 2). This outcome can take values between 0 and 100% with a lower value indicating better glucose control.",{"measure":38,"description":39,"timeFrame":21},"Percent of time with sensed glucose >250 mg\u002Fdl","Percent of time that sensed glucose is \\>250 mg\u002FdL comparing the results during the week when participants used the single-hormone insulin-only system (arm 1) versus the week when participants used the dual-hormone insulin and pramlintide system (arm 2). This outcome can take values between 0 and 100% with a lower value indicating better glucose control.",{"measure":41,"description":42,"timeFrame":21},"Mean amount of insulin delivered (in units and units\u002Fkg)","Mean amount of insulin delivered in units and units\u002Fkg comparing the results during the week when participants used the single-hormone insulin-only system (arm 1) versus the week when participants used the dual-hormone insulin and pramlintide system (arm 2). This outcome can take values between 0 and 200 units with a lower value indicating lower insulin requirements.",{"measure":44,"description":45,"timeFrame":21},"Mean amount of pramlintide delivered (in mcg and mcg\u002Fkg)","Mean amount of pramlintide delivered in mcg and mcg\u002Fkg comparing the results during the week when participants used the single-hormone insulin-only system (arm 1) versus the week when participants used the dual-hormone insulin and pramlintide system (arm 2). This outcome can take values between 0 and 1200 mcg, with lower values indicating lower insulin and pramlintide requirements.",{"measure":47,"description":48,"timeFrame":21},"Percent of time with sensed glucose between 70-180 mg\u002Fdl","Percent of time with sensed glucose between 70-180 mg\u002FdL comparing the results during the week when participants used the single-hormone insulin-only system (arm 1) versus the week when participants used the dual-hormone insulin and pramlintide system (arm 2). This outcome can take values between 0 and 100%, with lower values indicating lower insulin and pramlintide requirements.",{"measure":50,"description":51,"timeFrame":52},"Number of adverse events probably or possibly associated with Pramlintide administration","An AE is any clinically significant undesirable experience (sign, symptom, illness, or other medical event) meeting the causality definition above that appears or worsens in a participant during a clinical study. A clinically significant event is any event (sign, symptom, lab\u002Fimaging abnormality, or diagnosis) that is noteworthy enough to merit documentation in standard medical records (e.g. history and physical, progress notes, clinic visit notes, etc.). Other non-clinically significant events (e.g. colds, minor headaches, etc.) may be documented on the comments CRF. Mild hypoglycemia is expected in persons with diabetes using insulin and are typically self-limiting in nature; thus, this will not be captured as an AE.","Entire study duration.",{"measure":54,"description":55,"timeFrame":56},"Baxter Retching Faces (BARF) scale for standardized in-clinic meal","Participants will fill out the BARF questionnaire 6 hours after first in-clinic meal and at conclusion of the insulin + pramlintide dual-hormone arm of the study. A higher BARF score indicates more nausea.","6 hours after completion of in-clinic meal and at conclusion of the dual-hormone insulin and pramlintide arm of the study.",{"measure":58,"description":59,"timeFrame":56},"Mean duration of gastrointestinal issues after standardized in-clinic meal as reported by participant on BARF VAS scale","Participants will fill out the BARF questionnaire 6 hours after first in-clinic meal and at conclusion of the insulin + pramlintide dual-hormone arm of the study. A longer duration of gastrointestinal issues indicates a worse outcome.",{"measure":61,"description":62,"timeFrame":21},"Episodes of carbohydrate intake to treat hypoglycemia","We will count the average times that person takes carbohydrates to treat hypoglycemia comparing the results during the week when participants used the single-hormone insulin-only system (arm 1) versus the week when participants used the dual-hormone insulin and pramlintide system (arm 2). This outcome can take values between 0 and about 24, with lower values indicating reduced risk of hypoglycemia.",{"measure":64,"description":65,"timeFrame":21},"Mean number of low glucose events \u002F day","We will count the number of low glucose events \u002F day whereby a single low glucose event is defined to start when the CGM drops below 70 mg\u002FdL for at least three measurements and ends when the CGM rises above 69 mg\u002FdL for at least three measurements. We will compare the results during the week when participants used the single-hormone insulin-only system (arm 1) versus the week when participants used the dual-hormone insulin and pramlintide system (arm 2). This outcome can take values between 0 and about 24, with lower values indicating reduced risk of hypoglycemia.",null,{"allocation":68,"interventionModel":69,"interventionModelDescription":66,"primaryPurpose":70,"observationalModel":66,"timePerspective":66,"maskingInfo":71},"RANDOMIZED","CROSSOVER","HEALTH_SERVICES_RESEARCH",{"masking":72,"maskingDescription":66,"whoMasked":66},"NONE","Background:\n\nType 1 diabetes (T1D) is a complex disease and people with T1D are at high-risk of both hyper- and hypoglycemia which can lead to severe acute and chronic complications. Due to the burden and complexity of managing T1D, the vast majority of people with T1D do not reach the target HbA1c of \\\u003C7% as recommended by the American Diabetes Association. Data from the T1D Exchange, which includes 64 diabetes centers, demonstrated that 69% of patients in the exchange had HbA1c levels of \\>7.5%. The benefits of optimal glycemic control are well documented, including significant reductions in microvascular disease and to a lesser degree macrovascular disease. Achieving optimal glycemic control requires frequent glucose monitoring by finger-stick and\u002For continuous glucose monitoring (CGM) in combination with either multiple daily injection (MDI) or insulin pump therapy, or most recently, with an artificial pancreas (AP) system. AP systems automate insulin delivery based on CGM values to minimize hypoglycemia and hyperglycemia, and in some cases also deliver glucagon to prevent and treat hypoglycemia. AP systems have been tested extensively in both the inpatient and outpatient settings.\n\nCurrent commercial closed loop systems such as the Medtronic 670g and more recently Tandem's Control-IQ have demonstrated a modest improvement in the percent time in glucose target range (70-180 mg\u002FdL) of 5% for the 670g and 10% for the Control-IQ. However, the benefit is almost entirely due to improved glycemic control overnight when meals are not being consumed as shown by Kovatchev and colleagues. Our group has developed a multi-hormone (glucagon and insulin) closed loop system that improved time in range by 7.6% overall; but as with the commercial systems the majority of benefit was during the overnight hours where it exhibited 100% time in target range (70-180 mg\u002FdL) compared with 62.5% time in range for the control open loop system with predictive low glucose suspend Commercial closed-loop systems and the systems developed by our group are unable to effectively handle meals because the kinetics of subcutaneously delivered insulin are sufficiently slower than the body's absorption of carbohydrates. This delay in kinetics of insulin relative to meal absorption results in a rapid increase in glucose immediately following a meal that cannot be prevented, even if the appropriate amount of insulin is given at the time of the meal or even prior to meal consumption.\n\nCompounding this problem is the fact that many people struggle to adequately estimate their carbohydrates because they simply do not know the amount of carbohydrates in the food that they are consuming. Our group recently showed that 49% of smaller meals (carbs \\\u003C30 g) are overestimated by an average of 25.7 +\u002F- 17.2 g while 64% of larger meals (\\>60 g) are underestimated by an average of 53.6+\u002F-33.8 g by people with T1D under free-living conditions. Furthermore, people with T1D oftentimes forget to announce meals to the closed loop system altogether, leading to insufficient insulin at meal time, followed by possible over-dosing of insulin by the control algorithm immediately after the meal when glucose levels spike, which can then lead to both short-term hyperglycemia and also hypoglycemia hours after the meal. This is why the current commercial closed loop systems require users to announce meals to the system prior to eating. Hybrid closed loop systems use the carbohydrate amount entered by the user to dose the appropriate amount of insulin based on preset insulin to carbohydrate ratios. Requiring a person with T1D to announce meals is both a burden to the person, and as discussed above, missed doses and errors in carbohydrate estimations can lead to serious postprandial hypo- and hyperglycemic outcomes after a meal. The failure of hybrid closed loop systems to appropriately handle meals is the primary reason why these systems do not show a benefit during the daytime compared with manual control.\n\nIntegrating pramlintide into a dual hormone hybrid closed loop system is effective at substantially improving time in target range (70-180mg\u002FdL) during the daytime as shown by Haidar and colleagues. When people with T1D dosed a combination of rapid acting insulin and pramlintide, their time in target range was substantially lower following the meal compared with rapid acting insulin alone. Haidar et al. found that time in target range could be increased from 74% (SD 18%) to 84% (SD 13%) when incorporating pramlintide dosed with insulin prior to meals. Pramlintide is a synthetic form of amylin which is released with insulin from the beta cell in normal physiology. People with T1D loose both insulin and amylin secretion due to autoimmune beta cell destruction. Pramlintide is known to substantially blunt rate of appearance of glucose after a meal in T1D as shown by our group in Riddle et al by suppressing glucagon production to prevent hepatic glucose release and delaying gastric emptying via central nervous system effects. The slowing of gastric emptying by pramlintide controls the influx of glucose from the meal to better match the relatively slower kinetics of subcutaneous insulin for disposal of glucose. There is now a co-formulation in development of insulin with pramlintide that will allow for ease of dosing (Adocia Pharmaceuticals). M1Pram contains A21G human insulin analog (\"M1\"), which most closely matches pharmacokinetics of regular human insulin, along with the amylin analog pramlintide manufactured by AstraZeneca.\n\nWe have developed a meal detection and carb-estimation algorithm and we have integrated this algorithm within the context of a dual-hormone insulin and pramlintide closed loop system to enable fully automated closed loop control without requiring people with T1D to enter carbohydrates to the system. This meal detection and carb-estimation algorithm was shown in a clinical study to detect meals within 25.9 minutes of meal consumption with sensitivity of 83.3% and a false discovery rate of 16.6%. It was shown to reduce time above 180 mg\u002FdL by 10.8%.\n\nWe evaluated a prior iteration of this insulin + pramlintide dual hormone Automated Insulin Delivery System in an in clinic study where two \\~60g carbohydrated meals were consumed 6 hours apart under IRB #25279. We found a significant reduction in the incremental area under the glucose curve (incremental AUC \u002F 1000 in Insulin + Pram arm; First meal: -3 (adj p = 0.01); Second meal: -12 (adj p \\\u003C 0.001)). There was a similar average time to meal detection (29.2 +\u002F- 6.7 minutes in Insulin-Only arm, 29.7 +\u002F- 8.7 minutes in Insulin + Pramlintide arm). There was a significant improvement in time in range in Insulin + Pramlintide arm (TIR = 70-180 mg\u002FdL) for meal 1 and even more marked for meal 2 (49% TIR Insulin-only vs. 74% TIR Insulin + Pramlintide (p \\\u003C0.001)). This was achieved with clinically acceptable time below range in Insulin + Pram arm (TBR \\\u003C 70 mg\u002FdL) for first meal 1.0 % and for second meal 2.1 %.\n\nThe clinical study described in this protocol is an outpatient study to evaluate performance a non-hybrid, fully automated closed loop system that does not require the person to announce meals to the system, and which utilizes the hormone analog pramlintide in combination with insulin to potentially reduce the meal related hyperglycemia and increase the time spent in target range during the daytime.\n\nPrimary Objective:\n\nTo evaluate safety and efficacy of a fixed co-ratio insulin and pramlintide delivery strategy under closed loop as compared to an insulin alone under closed loop as measured by percent of time 70-180 mg\u002FdL on continuous glucose monitor during the daytime (06:00-23:59).\n\nSecondary Objective:\n\nTo evaluate performance of the fully closed-loop system with insulin+pramlintide as compared to insulin-only for other glycemic outcomes\n\nStudy Hypothesis:\n\nOur hypothesis is that pramlintide and insulin delivered by a closed loop system that does not require meal annoucement (a.k.a. fully closed loop) will allow for improved glucose control as measured by percent of time 70-180 mg\u002FdL during the daytime (06:00-23:59) as compared with an insulin-only fully closed loop system.\n\nEndpoints\n\nPrimary Endpoint:\n\nPercent of time with sensed glucose between 70-180 mg\u002Fdl during the daytime (06:00-23:59)\n\nSecondary Endpoints:\n\nIncremental area under the curve (iAUC) of postprandial glucose as measured by CGM in the 6 hours following the start of standarized in-clinic meal. iAUC (mg\u002FdL\\*min) will be calculated using a trapezoidal method \\[76\\], which sums all CGM values in the 6 hour period following the meal above the starting glucose.\n\nEach of the following endpoints for the daytime (06:00-23:59) and overnight (24:00-05:59) except where noted:\n\nPercent of time with sensed glucose \\\u003C70 mg\u002Fdl\n\n* Percent of time with sensed glucose between 70 - 140 mg\u002Fdl\n* Mean sensed glucose\n* Coefficient of variation of glucose\n* Percent of time with sensed glucose \\\u003C54 mg\u002Fdl\n* Percent of time with sensed glucose \\>180 mg\u002Fdl\n* Percent of time with sensed glucose \\>250 mg\u002Fdl\n* Mean amount of insulin delivered (in units and units\u002Fkg)\n* Mean amount of pramlintide delivered (in mcg and mcg\u002Fkg)\n* Percent of time with sensed glucose between 70-180 mg\u002Fdl for overnight period (24:00-05:59)\n\nEach of the following will be reported for the full study duration:\n\n* Mean amount of insulin delivered (in units and units\u002Fkg)\n* Mean amount of pramlintide delivered (in mcg and mcg\u002Fkg)\n* Safety endpoints (over full study duration):\n\nAdverse events Number of adverse events probably or possibly associated with pramlintide administration (see 'Causality Relationship' below) Baxter Retching Faces (BARF) VAS scale for standardized in-clinic meal, see Protocol Appendix C.\n\nMean duration of gastrointestinal issues after standardized in-clinic meal as reported by participant on BARF VAS scale, see Protocol Appendix C.\n\nEpisodes of carbohydrate intake to treat hypoglycemia (defined as 15g carbohydrate intake) Mean number of low glucose events \u002F day whereby a single low glucose event is defined to start when the CGM drops below 70 mg\u002FdL for at least three measurements and ends when the CGM rises above 69 mg\u002FdL for at least three measurements\n\nStudy Type This is a single-center, crossover trial designed to evaluate glucose outcomes of a fully closed-loop system with insulin+pramlintide as compared to an insulin alone fully closed loop system.\n\nStudy Population Study population will be participants with type 1 diabetes, ages 18-70 years of age. Up to 40 participants may be screened and up to 28 participants will be enrolled at OHSU.\n\nPower Analysis Assuming a standard deviation of 27 percentage points for the paired mean difference in daytime time in range (70-180 mg\u002FdL), a sample size of 24 participants provides approximately 80% power to detect a standardized paired mean difference of 0.49 SD (corresponding to a 16.1-percentage-point difference) and approximately 90% power to detect a standardized paired mean difference of 0.56 SD (corresponding to an 18.7-percentage-point difference).This was calculated using a paired t test to approximate a mixed model with treatment, period, and sequence effects. Data from a previous study under IRB #25279 was used to determine these estimates. We will enroll up to 28 participants to allow for potential non completion of the study, with a goal to complete at least 24 participants.\n\nProtocol Summary:\n\nParticipants will complete two study arms, each lasting 7 days, with a minimum 3-day washout period between arms, to evaluate (1) insulin plus pramlintide and (2) insulin-only delivery strategies. The order of the visits will be randomized. The standarized in-clinic meal will be identical across study arms. Participants will arrive at approximately 8 am for all visits, be monitored through the afternoon and discharged at approximately 4 pm. During each study visit, participants will wear Omnipod(s) to deliver insulin and\u002For pramlintide, use a study provided phone which runs the system, wear a Dexcom G6 CGM to measure glucose and a Pixel smartwatch to measure activity levels.",[75,81],{"label":76,"type":77,"description":78,"interventionNames":79},"Single-hormone automated insulin delivery","EXPERIMENTAL","Participants will use a single-hormone automated insulin delivery system to manage their glucose levels. The system comprises an Google Pixel smart phone, a Dexcom G6 continuous glucose monitor, an Insulet Omnipod Dash pump filled with insulin, and a Google Pixel smart watch to capture exercise.",[80],"Device: Single-hormone automated insulin delivery system",{"label":82,"type":77,"description":83,"interventionNames":84},"Dual-hormone automated insulin and pramlintide delivery","Participants will use the closed loop system with insulin and pramlintide for managing blood sugar for 1 week. Insulin and pramlintide will be administered by two Omnipods. Sensor glucose will be measured by a Dexcom G6 CGM.",[85],"Device: Dual-hormone automated insulin and pramlintide delivery system",[87,92],{"type":88,"name":89,"description":90,"armGroupLabels":91,"otherNames":66},"DEVICE","Single-hormone automated insulin delivery system","The intervention in this arm is a single-hormone automated insulin delivery system that delivers insulin in response to sensed continuous glucose monitoring data (CGM) received from a Dexcom G6 CGM. The system automatically detects meals and delivers meal insulin based on the detected meal size. Users of the system have the option to use a bolus calculator to dose meal insulin in advance of their meals if they choose. The AID also automatically detects exercise and adjusts insulin based on increased levels of physical activity. The system comprises an Android Pixel smart phone running the AID control algorithm, a Dexcom G6 sensor, an Insulet Omnipod Dash pump, and an Android Pixel smart watch to quantify exercise.",[76],{"type":88,"name":93,"description":94,"armGroupLabels":95,"otherNames":66},"Dual-hormone automated insulin and pramlintide delivery system","The intervention in this arm is a dual-hormone automated insulin and pramlintide delivery system that delivers insulin and pramlintide in response to sensed continuous glucose monitoring data (CGM) received from a Dexcom G6 CGM. Insulin and pramlintide are delivered in a fixed ratio of 1 u insulin: 6 mcg pramlintide. The system automatically detects meals and delivers meal insulin and pramlintide based on the detected meal size. Users of the system have the option to use a bolus calculator to dose meal insulin and pramlintide in advance of their meals if they choose. The system also automatically detects exercise and adjusts insulin based on increased levels of physical activity. The system comprises an Android Pixel smart phone running the AID control algorithm, a Dexcom G6 sensor, an Insulet Omnipod Dash pump filled with insulin, a Dash pump filled with pramlintide, and an Android Pixel smart watch to quantify exercise.",[82],[97,102],{"name":98,"role":99,"phone":100,"phoneExt":66,"email":101},"Peter Jacobs, PhD","CONTACT","503-418-9331","jacobsp@ohsu.edu",{"name":103,"role":99,"phone":104,"phoneExt":66,"email":105},"Samrita Thapa, MPH","503-494-8421","thapasa@ohsu.edu",{"type":107,"investigatorFullName":108,"investigatorTitle":109,"investigatorAffiliation":5,"oldNameTitle":66,"oldOrganization":66},"PRINCIPAL_INVESTIGATOR","Linda Lester","Associate Professor",[111],{"name":112,"class":113},"National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)","NIH","100663162","outpatient-pramlintide-study-100663162",false,"NCT07914621","Outpatient Pramlintide Study","An Outpatient Crossover Study to Evaluate Insulin and Pramlintide Versus Insulin Alone Delivery Strategy","Inclusion Criteria:\n\n* Diagnosis of type 1 diabetes mellitus for at least 1 year.\n* Participants 18 to 70 years of age.\n* Current use of an insulin pump for at least 3 months with stable insulin pump settings for \\>2 weeks.\n* Uses a carbohydrate ratio, at least occasionally, to dose meal-time insulin\n* HbA1c ≤ 10.5% at screening.\n* Total daily insulin requirement is less than 139 units\u002Fday.\n* Lives with another person age 18 or older who will sleep in the house at night and that can attend the training on using the system.\n* Current use of a smartphone so can be contacted by study staff off-campus\n* Willingness to follow all study procedures, including attending all clinic visits.\n* Willingness to sign informed consent and HIPAA documents.\n\nExclusion Criteria:\n\n* Individual of childbearing potential who is pregnant or intending to become pregnant or breast-feeding, or is not using adequate contraceptive methods. Acceptable contraception includes birth control pill \u002F patch \u002F vaginal ring, Depo-Provera, Norplant, an IUD, the double barrier method (the woman uses a diaphragm and spermicide and the man uses a condom), or abstinence.\n* Any cardiovascular disease, defined as a clinically significant EKG abnormality at the time of screening or any history of: stroke, heart failure, myocardial infarction, angina pectoris, or coronary arterial bypass graft or angioplasty. Diagnosis of 2nd or 3rd degree heart block or any non-physiological arrhythmia judged by the investigator to be exclusionary.\n* Renal insufficiency (GFR \\\u003C 60 ml\u002Fmin, using the MDRD equation as reported by the site laboratory).\n* Liver failure, cirrhosis, or any other liver disease that compromises liver function as determined by the investigator.\n* History of severe hypoglycemia during the past 3 months prior to screening visit or hypoglycemia unawareness as judged by the investigator.\n* Participants will complete a hypoglycemia awareness questionnaire included in Appendix A. Participants will be excluded for four or more R responses.\n* History of diabetes ketoacidosis during the prior 3 months prior to screening visit, as diagnosed on hospital admission or as judged by the investigator.\n* Adrenal insufficiency.\n* Any active infection requiring treatment (example soft tissue infection requiring antibiotics).\n* Known or suspected abuse of alcohol, narcotics, or illicit drugs.\n* Seizure disorder.\n* Active foot ulceration.\n* Severe peripheral arterial disease characterized by ischemic rest pain or severe claudication.\n* Major surgical operation within 30 days prior to screening.\n* Use of an investigational drug within 30 days prior to screening.\n* Chronic usage of any immunosuppressive medication (such as cyclosporine, azathioprine, sirolimus, or tacrolimus).\n* Bleeding disorder, treatment with warfarin, or platelet count below 50,000.\n* Allergy to Aspart insulin.\n* Allergy or intolerance of pramlintide.\n* Current administration of oral or parenteral corticosteroids.\n* Any life-threatening disease, including malignant neoplasms and medical history of malignant neoplasms within the past 5 years prior to screening (except basal and squamous cell skin cancer).\n* Current use of beta blockers or non-dihydropyridine calcium channel blockers.\n* Current use of any medication that may lower glucose other than insulin or pramlintide (ex. use of liraglutide, metformin, empaglifozin etc) including the use of GLP1RA medications for weight loss (ex. Wegovy or Zepbound).\n* Gastroparesis or history of chronic nausea and\u002For frequent emesis.\n* Low carbohydrate diet at the time of screening defined as less than 50 grams of carbohydrate per day.\n* Any clinically significant disease or disorder which in the opinion of the Investigator may jeopardize the participant's safety or compliance with the protocol","ALL","18 Years","70 Years",{"count":125,"type":126},26,"ESTIMATED","INTERVENTIONAL",[129],"NA","The primary purpose of this study is to compare the performance of a dual-hormone automated insulin delivery (AID) system that delivers both insulin and pramlintide with an AID that only delivers insulin. Our hypothesis is that people using the dual-hormone AID will have a significantly increased percent time in range (70-180 mg\u002FdL) compared with when they use a single-hormone insulin-only AID. Both systems are designed to automatically dose meal insulin if the participant forgets to enter their meal insulin at the time of their meals.",[132],"Type 1 Diabetes","NOT_YET_RECRUITING","2026-11-07",{"date":136,"type":137},"2026-11-12","ACTUAL",{"date":139,"type":126},"2026-11-02",{"date":141,"type":126},"2027-01-31",{"name":5,"class":6}]