[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100664445":3},{"organization":4,"outcomesModule":7,"designInfo":57,"detailedDescription":67,"studyPopulation":56,"armGroups":68,"interventions":81,"overallOfficials":56,"centralContacts":93,"locations":99,"responsibleParty":111,"collaborators":56,"id":115,"slug":116,"hasResults":117,"nctId":118,"briefTitle":119,"officialTitle":120,"acronym":56,"eligibilityCriteria":121,"healthyVolunteers":117,"sex":122,"minAge":123,"maxAge":124,"enrollmentInfo":125,"targetDuration":56,"studyType":128,"phases":129,"briefSummary":131,"conditions":132,"keywords":137,"overallStatus":146,"whyStopped":56,"lastUpdateSubmitDate":147,"lastUpdatePostDateStruct":148,"startDateStruct":151,"completionDateStruct":153,"leadSponsor":155,"locationsCount":156},{"fullName":5,"class":6},"Beni-Suef University","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":17,"otherOutcomes":56},[9,13],{"measure":10,"description":11,"timeFrame":12},"Mean Expired Tidal Volume (VTe) Delivery Accuracy","Measured in milliliters per kilogram of ideal body weight (mL\u002Fkg IBW) using the anesthesia workstation flow sensor. Evaluates delivery accuracy relative to the prescribed target (6.0-7.0 mL\u002Fkg IBW).\n\nValues within the target prescribed range (6.0-7.0 mL\u002Fkg IBW) indicate a good result (effective alveolar ventilation). Values significantly below target (\\\u003C 5.0 mL\u002Fkg IBW) indicate a bad result (hypoventilation due to circuit leak), while values above target (\\> 8.0 mL\u002Fkg IBW) indicate a bad result (risk of volutrauma).","Measured at 20 minutes post-initiation of mechanical ventilation (T1) and at end of surgery \u002F pre-emergence (T2, up to 120 minutes)",{"measure":14,"description":15,"timeFrame":16},"Percentage of Participants With Ultrasonographically Confirmed Gastric Insufflation","Defined as an increase in serial radiologist-measured gastric antrum cross-sectional area (CSA) ≥ 20% from baseline (T0), confirmed on ≥ 2 of 3 measurements at either T1 or T2, calculated using the ellipse formula: CSA=(π × D1 × D2)\u002F4 A lower percentage indicates a good result (enhanced gastric safety and effective airway seal). A higher percentage indicates a bad result (increased risk of gastric distension, elevated intra-abdominal pressure, and pulmonary aspiration).","Intraoperative period (assessed at 20 minutes post-ventilation [T1] and end of surgery [T2], up to 120 minutes total)",[18,21,24,28,32,36,40,44,48,52],{"measure":19,"description":20,"timeFrame":12},"Mean Peak Inspiratory Pressure (Ppeak)","Peak airway pressure measured in centimeters of water (cmH2O) directly from the anesthesia workstation pressure transducer.\n\nA lower value indicates a good result (reduced risk of barotrauma and lower potential to exceed oropharyngeal leak pressure). A higher value indicates a bad result (increased pulmonary barotrauma risk and higher likelihood of driving gas into the esophagus).",{"measure":22,"description":23,"timeFrame":12},"Mean Dynamic Respiratory System Compliance (Cdyn)","Calculated using the formula: Cdyn= (VTe) ÷(Ppeak-PEEP), expressed in mL\u002FcmH2O. A higher value indicates a good result (superior lung\u002Fthoracic compliance and lower resistance to inflation). A lower value indicates a bad result (stiffer lungs, higher airway resistance, or increased impedance).",{"measure":25,"description":26,"timeFrame":27},"Mean Oropharyngeal Leak Pressure (OLP)","Airway pressure in cmH2O at which an anterior cervical leak is detected on precordial auscultation during circuit occlusion.\n\nA higher value indicates a good result (a tighter perilaryngeal device seal capable of sustaining higher positive pressure without leaking). A lower value indicates a bad result (poor device seal and higher risk of leak).","Measured immediately post-i-gel placement (T0) and at 20 minutes post-initiation of mechanical ventilation (T1)",{"measure":29,"description":30,"timeFrame":31},"Mean End-Tidal Carbon Dioxide (EtCO2) Concentration","Measured in millimeters of mercury (mmHg) using continuous side-stream capnography on the anesthesia workstation to assess systemic ventilation status and carbon dioxide elimination.\n\nDirectional Interpretation: Values within the physiological target range (35-45 mmHg) indicate a good result (optimal normocapnic ventilation). Values significantly above target (\\> 45 mmHg) indicate a bad result (hypercapnia\u002Fhypoventilation due to circuit leak or dead-space rebreathing), while values below target (\\\u003C 30 mmHg) indicate a bad result (hypocapnia due to hyperventilation).","Measured at T0 (post-i-gel placement), T1 (20 minutes post-ventilation start), T2 (end of surgery), and at emergence \u002F i-gel removal (up to 120 minutes)",{"measure":33,"description":34,"timeFrame":35},"Percentage of Total Mechanical Ventilation Time With Hypercapnia (EtCO2 > 50 mmHg)","Percentage calculated as: 100 × \\[(Duration of mechanical ventilation with EtCO2 \\> 50 mmHg)÷(Total Mechanical Ventilation Time)\\].\n\nA lower percentage (ideally 0%) indicates a good result (effective carbon dioxide clearance throughout the surgical procedure). A higher percentage indicates a bad result (sustained alveolar hypoventilation or persistent leak leading to carbon dioxide retention).","Total duration of mechanical ventilation (up to 120 minutes)",{"measure":37,"description":38,"timeFrame":39},"Percentage of Mechanical Breaths Exceeding Baseline Oropharyngeal Leak Pressure","Percentage calculated as: 100 × \\[(Breaths where Ppeak)\\> (Baseline OLP)÷ (Total Mechanical Breaths)\\].\n\nA lower value (ideally 0%) indicates a good result (effective pressure containment within safe seal thresholds). A higher value indicates a bad result (frequent pressure spikes above the seal threshold, driving air into the stomach).","Entire duration of mechanical ventilation (up to 120 minutes)",{"measure":41,"description":42,"timeFrame":43},"Percentage of Participants Experiencing Intraoperative Respiratory Adverse Events","Composite incidence of laryngospasm, bronchospasm, oxygen desaturation (SpO2 \\\u003C 93%), i-gel displacement, or endotracheal intubation conversion.\n\nA lower percentage indicates a good result (superior airway safety and stability). A higher percentage indicates a bad result (increased perioperative respiratory complications).","From i-gel insertion until PACU transfer (up to 180 minutes)",{"measure":45,"description":46,"timeFrame":47},"i-gel Insertion Time","Time in seconds from first device handling until capnographic confirmation of airway placement.\n\nA lower value indicates a good result (faster, smoother airway securing). A higher value indicates a bad result (prolonged or difficult device placement).","At time of airway placement (induction period, approximately 1-3 minutes)",{"measure":49,"description":50,"timeFrame":51},"Post-Anaesthesia Care Unit (PACU) Length of Stay","PACU entry to achieving a modified Aldrete Score ≥ 9\u002F10. A lower value indicates a good result (faster recovery and readiness for ward transfer). A higher value indicates a bad result (delayed recovery or lingering anesthetic effects).","Postoperative recovery period (up to 120 minutes)",{"measure":53,"description":54,"timeFrame":55},"Percentage of Participants With Postoperative Airway Complications at 24 Hours","Composite incidence of sore throat, hoarseness, or dysphagia assessed at 24 hours via telephone.\n\nA lower percentage indicates a good result (minimal airway mucosal trauma). A higher percentage indicates a bad result (higher postoperative airway morbidity).","24 hours postoperatively",null,{"allocation":58,"interventionModel":59,"interventionModelDescription":56,"primaryPurpose":60,"observationalModel":56,"timePerspective":56,"maskingInfo":61},"RANDOMIZED","PARALLEL","TREATMENT",{"masking":62,"maskingDescription":56,"whoMasked":63},"TRIPLE",[64,65,66],"PARTICIPANT","CARE_PROVIDER","OUTCOMES_ASSESSOR","Background and Rationale:\n\nControlled positive-pressure ventilation (PPV) via second-generation supraglottic airway devices (SADs) such as the i-gel is widely practiced in pediatric anesthesia. However, because SADs do not provide an absolute tracheal seal, peak inspiratory pressure (PIP) exceeding the individual oropharyngeal leak pressure (OLP) risks gas bypassing the cuff into the esophagus. Gastric insufflation increases intra-abdominal pressure, restricts diaphragmatic excursion, and elevates the risk of aspiration. Pressure-controlled ventilation with volume guarantee (PCV-VG) combines a decelerating flow profile with breath-by-breath feedback to deliver target tidal volume at the lowest feasible PIP. While studied in laparoscopic settings, prospective evidence evaluating PCV-VG versus VCV using serial radiologist-performed gastric antrum ultrasonography in non-laparoscopic pediatric surgery remains lacking.\n\nObjectives:\n\nTo compare PCV-VG against VCV in children aged 2 to 7 years undergoing elective non-laparoscopic surgery with the i-gel across two co-primary domains:\n\nVentilatory efficacy: mean expired tidal volume (VTe) delivery relative to ideal body weight target.\n\nGastric safety: incidence of ultrasonographically confirmed gastric insufflation (antral cross-sectional area \\[CSA\\] increase ≥ 20% from baseline).\n\nTrial Design \\& Interventions:\n\nA prospective, single-center, parallel-group, double-blind, randomized superiority trial conducted at Beni-Suef University Hospital. Ninety children (2-7 years, weight 10-25 kg, ASA I-II) scheduled for elective non-laparoscopic procedures under general anesthesia with i-gel placement will be randomized 1:1 to:\n\nGroup PCV-VG (n = 45): Target VT 6-7 mL\u002Fkg IBW, PEEP 4 cmH2O, I:E 1:2, respiratory rate adjusted to EtCO2 35-45 mmHg, with closed-loop pressure adjustment capped at baseline OLP minus 3 cmH2O (absolute maximum 20 cmH2O).\n\nGroup VCV (n = 45): Target VT 6-7 mL\u002Fkg IBW with constant square inspiratory flow, identical PEEP, I:E, and RR targets, without active leak compensation.\n\nUltrasonic Evaluation Protocol:\n\nA blinded consultant radiologist will perform serial sagittal gastric antrum ultrasonography at three defined timepoints:\n\nT0: Immediately post-i-gel placement (baseline) T1: 20 minutes post-initiation of mechanical ventilation T2: End of surgery (pre-emergence) Antral cross-sectional area (CSA) will be calculated via the ellipse formula (π × D1 × D2 \u002F 4). A positive gastric insufflation event is defined as a post-baseline CSA increase ≥ 20% confirmed on at least 2 of 3 measurements.",[69,75],{"label":70,"type":71,"description":72,"interventionNames":73},"Group PCV-VG (Pressure-Controlled Ventilation with Volume Guarantee)","EXPERIMENTAL","Patients in this group will receive mechanical ventilation using Pressure-Controlled Ventilation with Volume Guarantee (PCV-VG; Draeger AutoFlow or platform equivalent) through an i-gel supraglottic airway device following standard intravenous induction and muscle relaxation with atracurium.\n\nVentilation parameters: Target tidal volume (VT) set at 6-7 mL\u002Fkg ideal body weight (IBW), PEEP 4 cmH2O, I:E ratio 1:2, and age-stratified respiratory rate adjusted to maintain EtCO2 at 35-45 mmHg. The closed-loop algorithm dynamically auto-titrates inspiratory pressure (Pinsp) breath-by-breath based on the previous breath's expired tidal volume (VTe) to achieve target VT, with Pinsp safety ceiling capped at the individual baseline oropharyngeal leak pressure (OLP) minus 3 cmH2O (absolute maximum 20 cmH2O).",[74],"Procedure: Pressure-Controlled Ventilation with Volume Guarantee (PCV-VG)",{"label":76,"type":77,"description":78,"interventionNames":79},"Group VCV (Volume-Controlled Ventilation)","ACTIVE_COMPARATOR","Patients in this group will receive standard mechanical ventilation using Volume-Controlled Ventilation (VCV) through an i-gel supraglottic airway device following standard intravenous induction and muscle relaxation with atracurium.\n\nVentilation parameters: Set tidal volume (VT) programmed at 6-7 mL\u002Fkg ideal body weight (IBW) with a constant square inspiratory flow waveform, PEEP 4 cmH2O, I:E ratio 1:2, and age-stratified respiratory rate adjusted to maintain EtCO2 at 35-45 mmHg. No active closed-loop leak-compensation or pressure-guarantee algorithm is engaged. Peak inspiratory pressure safety limit is set at baseline OLP minus 3 cmH2O (absolute maximum 20 cmH2O). If VTe falls \\> 20% below set VT for ≥ 3 consecutive breaths, VT may be up-titrated in 0.5 mL\u002Fkg IBW increments up to maximum 9 mL\u002Fkg IBW provided peak pressure remains below OLP.",[80],"Procedure: Volume-Controlled Ventilation (VCV)",[82,89],{"type":83,"name":84,"description":85,"armGroupLabels":86,"otherNames":87},"PROCEDURE","Pressure-Controlled Ventilation with Volume Guarantee (PCV-VG)","Administration of closed-loop pressure-controlled ventilation with volume guarantee via the i-gel supraglottic airway, maintaining target VT 6-7 mL\u002Fkg IBW with breath-by-breath inspiratory pressure auto-titration.",[70],[88],"PCV-VG",{"type":83,"name":90,"description":91,"armGroupLabels":92,"otherNames":56},"Volume-Controlled Ventilation (VCV)","Administration of traditional volume-controlled ventilation with constant inspiratory flow via the i-gel supraglottic airway, maintaining set VT 6-7 mL\u002Fkg IBW without automated pressure adaptation.",[76],[94],{"name":95,"role":96,"phone":97,"phoneExt":56,"email":98},"Kerollos Moneer Neseem Mikhael, MD","CONTACT","00201288549959","Kmnmk87@med.bsu.edu.eg",[100],{"facility":101,"status":56,"city":102,"state":56,"zip":56,"country":103,"countryCode":104,"cosmosGeoPoint":105,"geoPoint":110,"contacts":56},"Beni-Suef University Hospital","Banī Suwayf","Egypt","EG",{"type":106,"coordinates":107},"Point",[108,109],31.09785,29.07441,{"lat":109,"lon":108},{"type":112,"investigatorFullName":113,"investigatorTitle":114,"investigatorAffiliation":5,"oldNameTitle":56,"oldOrganization":56},"PRINCIPAL_INVESTIGATOR","Kerollos Moneer Neseem Mikhael","Lecturer of Anesthesiology, Surgical Intensive care and Pain Management, Faculty of Medicine, Beni-suef university","100664445","pcv-vg-versus-vcv-through-the-i-gel-in-young-children-100664445",false,"NCT07928791","PCV-VG Versus VCV Through the I-gel in Young Children","PCV-VG Versus VCV for Ventilatory Efficacy and Gastric Safety Through the I-gel Supraglottic Airway in Young Children: A Randomized Controlled Trial","Inclusion Criteria:\n\n* Children aged 2 to 7 years inclusive\n* Body weight 10 to 25 kg inclusive\n* American Society of Anesthesiologists (ASA) physical status classification I or II\n* Scheduled for elective non-laparoscopic surgical procedures of anticipated duration 30 to 120 minutes, not involving the airway, head, or neck (e.g., orthopedic, urological, perineal, or minor extremity procedures)\n* Suitability for i-gel supraglottic airway management under controlled positive-pressure ventilation, as judged by the attending anesthesiologist\n* Written informed consent obtained from a parent or legal guardian, and age-appropriate assent obtained from children aged ≥ 7 years\n\nExclusion Criteria:\n\n* Anticipated or known difficult airway (history of failed supraglottic airway device insertion, syndromic anatomical airway anomalies, Mallampati class IV, or inter-incisor gap \\\u003C 20 mm)\n* Active upper or lower respiratory tract infection within 2 weeks prior to surgery\n* Reactive airway disease (asthma or bronchiolitis) with active wheeze or exacerbation within 4 weeks\n* Obesity: body mass index (BMI) ≥ 97th centile for age and sex according to WHO Child Growth Standards (2006)\n* Gastro-esophageal reflux disease, symptomatic hiatus hernia, or any other condition conferring elevated pulmonary aspiration risk\n* Congenital or acquired pulmonary disease (e.g., chronic lung disease of prematurity, cystic fibrosis, interstitial lung disease)\n* Significant cardiovascular disease (ASA physical status ≥ III)\n* Neuromuscular disease affecting respiratory mechanics\n* Surgical procedure requiring prone, lateral decubitus, or head-down (Trendelenburg \\> 15°) positioning\n* Emergency or semi-elective surgical cases\n* Known allergy or documented contraindication to any anesthetic agent used in the protocol (propofol, sevoflurane, fentanyl, atracurium)\n* Laparoscopic surgical procedure\n* Enrollment in another interventional clinical trial within the preceding 30 days","ALL","2 Years","7 Years",{"count":126,"type":127},90,"ESTIMATED","INTERVENTIONAL",[130],"NA","Supraglottic airway devices (SADs) like the i-gel are frequently used to manage airways during general anesthesia in children. However, delivering positive-pressure mechanical ventilation through a supraglottic airway carries a risk of gas leaking around the cuff into the stomach (gastric insufflation), which can cause stomach distension and increase the risk of regurgitation.\n\nVolume-controlled ventilation (VCV) delivers a fixed breath volume, which can cause spikes in peak inspiratory pressure if airway resistance changes, potentially exceeding the device seal and forcing air into the stomach. Pressure-controlled ventilation with volume guarantee (PCV-VG) uses closed-loop feedback to auto-titrate inspiratory pressure breath-by-breath to target the desired tidal volume while minimizing peak airway pressures.\n\nThis prospective, single-center, randomized controlled trial aims to evaluate whether PCV-VG offers superior ventilatory efficacy (accurate tidal volume delivery) and enhanced gastric safety (lower incidence of ultrasonographically detected gastric insufflation) compared to VCV when using the i-gel supraglottic airway in children aged 2 to 7 years undergoing elective non-laparoscopic surgery",[133,134,135,136],"General Aneshesia","Intraoperative Complications","Gastric Insufflation","Airway Management",[138,88,139,140,141,142,143,144,145],"Pressure-Controlled Volume-Guaranteed Ventilation","Volume-Controlled Ventilation","VCV","i-gel","Supraglottic Airway Device","Pediatric Anesthesia","Gastric Ultrasonography","Antral Cross-Sectional Area","NOT_YET_RECRUITING","2026-11-04",{"date":149,"type":150},"2026-11-10","ACTUAL",{"date":152,"type":127},"2026-11",{"date":154,"type":127},"2027-05",{"name":5,"class":6},1]