[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100661677":3},{"organization":4,"outcomesModule":7,"designInfo":50,"detailedDescription":57,"studyPopulation":49,"armGroups":58,"interventions":66,"overallOfficials":77,"centralContacts":81,"locations":86,"responsibleParty":120,"collaborators":123,"id":127,"slug":128,"hasResults":129,"nctId":130,"briefTitle":131,"officialTitle":132,"acronym":133,"eligibilityCriteria":134,"healthyVolunteers":135,"sex":136,"minAge":137,"maxAge":49,"enrollmentInfo":138,"targetDuration":49,"studyType":141,"phases":142,"briefSummary":143,"conditions":144,"keywords":149,"overallStatus":154,"whyStopped":49,"lastUpdateSubmitDate":155,"lastUpdatePostDateStruct":156,"startDateStruct":159,"completionDateStruct":161,"leadSponsor":163,"locationsCount":164},{"fullName":5,"class":6},"University of Plymouth","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":21,"otherOutcomes":49},[9,13,16,18],{"measure":10,"description":11,"timeFrame":12},"Agreement between the OCUTOP and the reference instrument for central simulated mean keratometry (K-mean)","Mean paired difference (OCUTOP minus reference, dioptres) with 95% confidence interval, and Bland-Altman 95% limits of agreement with their 95% confidence intervals, in the analysis eye, pooled across sites and by site. Reference: Pentacam HR (Site 01), Myah (Site 02).","Single study visit (Day 1)",{"measure":14,"description":15,"timeFrame":12},"Agreement between the OCUTOP and the reference instrument for first non-invasive tear break-up time (NIBUT-first)","Mean paired difference (OCUTOP minus reference, seconds) with 95% confidence interval, and Bland-Altman 95% limits of agreement with their 95% confidence intervals, in the analysis eye, pooled across sites and by site. Reference: Keratograph 5M (Site 01), Myah (Site 02).",{"measure":17,"description":15,"timeFrame":12},"Agreement between the OCUTOP and the reference instrument for average non-invasive tear break-up time (NIBUT-average)",{"measure":19,"description":20,"timeFrame":12},"Agreement between the OCUTOP and the reference instrument for central lower tear meniscus height (TMH)","Mean paired difference (OCUTOP minus reference, millimetres) with 95% confidence interval, and Bland-Altman 95% limits of agreement with their 95% confidence intervals, in the analysis eye, pooled across sites and by site. Reference: Keratograph 5M (Site 01), Myah (Site 02).",[22,25,28,31,34,37,40,43,46],{"measure":23,"description":24,"timeFrame":12},"Repeatability of the OCUTOP and of each reference instrument","Within-subject standard deviation, repeatability coefficient, coefficient of variation and intraclass correlation coefficient from repeat captures, for K-mean, NIBUT-first, NIBUT-average, TMH, K1, K2 and the astigmatism vectors J0 and J45.",{"measure":26,"description":27,"timeFrame":12},"Agreement for K1, K2 and the astigmatism vectors J0 and J45","Mean paired difference and 95% limits of agreement with 95% confidence intervals for K1, K2, J0 and J45, OCUTOP against each reference instrument and, at Site 01, against the Medmont E300.",{"measure":29,"description":30,"timeFrame":12},"Classification agreement at TFOS cut-offs","Agreement between the OCUTOP and the reference instrument in classifying eyes at the TFOS cut-offs (NIBUT below 10 s; TMH below 0.2 mm): Cohen's kappa, sensitivity and specificity with the reference as standard.",{"measure":32,"description":33,"timeFrame":12},"Inter-operator reproducibility of the OCUTOP","Between-operator differences and limits of agreement for the primary measures in the first 20 participants per site, each measured with the OCUTOP by two operators.",{"measure":35,"description":36,"timeFrame":12},"Acquisition yield","Proportion of OCUTOP captures and videos rated unusable, overall and by site, reporting group and operator.",{"measure":38,"description":39,"timeFrame":12},"Participant acceptability and clinician usability","Participant acceptability of the OCUTOP measured with a short study questionnaire (comfort, duration, willingness to be measured again); clinician usability of the device and the OCUGRAPH interface measured with the System Usability Scale (0 to 100, higher is better).",{"measure":41,"description":42,"timeFrame":12},"Agreement and repeatability within record-defined groups","Descriptive agreement and repeatability statistics for the primary measures within the reporting groups formed from the clinical record (normal cornea, keratoconus, previous corneal or refractive surgery, corneal scar, high myopia, dry eye).",{"measure":44,"description":45,"timeFrame":12},"Dry-eye symptom scores and their relation to tear-film measures","DEQ-5 and SPEED questionnaire scores, their correlation with NIBUT and TMH from each instrument, and dry-eye classification by the TFOS DEWS III definition.",{"measure":47,"description":48,"timeFrame":12},"Safety: adverse events, adverse device effects, device deficiencies and participant-reported discomfort","Number and nature of adverse events, adverse device effects and device deficiencies recorded during and after the visit, and participant-reported discomfort on the acceptability questionnaire.",null,{"allocation":51,"interventionModel":52,"interventionModelDescription":53,"primaryPurpose":54,"observationalModel":49,"timePerspective":49,"maskingInfo":55},"NA","SINGLE_GROUP","Within-participant method-comparison and repeatability study. Every participant has both eyes measured with the investigational device and with the site reference instruments at a single visit; only the order of the instrument blocks and of the eyes is randomised.","DIAGNOSTIC",{"masking":56,"maskingDescription":49,"whoMasked":49},"NONE","Prospective, single-visit, within-participant method-comparison and repeatability study of the OCUTOP corneal topographer with OCUGRAPH software at two non-NHS sites in the United Kingdom (Centre for Eyecare Excellence, University of Plymouth; Simon Berry Optometrist, Durham). Participants are adults attending either clinic for any reason, invited consecutively; reporting groups (normal cornea, keratoconus, previous corneal or refractive surgery, corneal scar, high myopia, dry eye) are formed afterwards from the clinical record. Both eyes are measured with the OCUTOP and with the site reference instruments; the order of instrument blocks and of eyes is randomised. Reference instruments are the Pentacam HR and Keratograph 5M at Site 01 (with the Medmont E300 as an additional topographer) and the Myah at Site 02. The study is an estimation study without a formal hypothesis test: for each co-primary endpoint the mean paired difference (OCUTOP minus reference) and the 95% limits of agreement, each with 95% confidence intervals, are reported and read against pre-specified clinical interpretation thresholds. The sample size of 100 evaluable participants (one analysis eye each; recruitment ceiling 150) is set by the precision of the limits of agreement. Secondary analyses cover repeatability, agreement for K1, K2 and astigmatism vectors, classification agreement at TFOS cut-offs, inter-operator reproducibility, acquisition yield, participant acceptability and clinician usability, symptom scores and safety. A Statistical Analysis Plan is signed before the first participant. The investigation is conducted under the UK Medical Devices Regulations 2002 (regulation 16) and ISO 14155:2026, with MHRA notification and Research Ethics Committee review through IRAS (370513).",[59],{"label":60,"type":61,"description":62,"interventionNames":63},"OCUTOP and reference instruments","EXPERIMENTAL","All participants. At a single visit, both eyes are measured with the OCUTOP corneal topographer (OCUGRAPH software) and with the site reference instruments (Pentacam HR, Keratograph 5M and Medmont E300 at Site 01; Myah at Site 02), in a randomised order of instrument blocks and eyes, with a rest of at least 5 minutes between blocks. Participants complete two short questionnaires. No treatment is given and there is no follow-up.",[64,65],"Device: OCUTOP hand-held corneal topographer with OCUGRAPH software","Diagnostic Test: Reference instrument measurement (corneal topography and tear-film assessment)",[67,72],{"type":68,"name":69,"description":70,"armGroupLabels":71,"otherNames":49},"DEVICE","OCUTOP hand-held corneal topographer with OCUGRAPH software","Investigational hand-held, non-contact, Placido-based corneal topographer with integrated non-invasive tear-film assessment (tear break-up time and tear meniscus height), operated through the OCUGRAPH software on a Windows computer. The device rim rests on the skin around the eye; nothing touches the eye. Both eyes are imaged at one visit, with repeat captures for repeatability. The device is not UKCA or CE marked and is labelled exclusively for clinical investigation. Manufacturer: OCUWELL Limited.",[60],{"type":73,"name":74,"description":75,"armGroupLabels":76,"otherNames":49},"DIAGNOSTIC_TEST","Reference instrument measurement (corneal topography and tear-film assessment)","Corneal topography and non-invasive tear-film assessment with the CE or UKCA marked instruments in routine use at each site, used within their intended purpose: Pentacam HR (topography) and Keratograph 5M (tear film) at Site 01, with the Medmont E300 as an additional topographer; Myah (topography and tear film) at Site 02. Both eyes, same visit, repeat captures for repeatability.",[60],[78],{"name":79,"affiliation":5,"role":80},"Daniela Oehring, PhD","PRINCIPAL_INVESTIGATOR",[82],{"name":79,"role":83,"phone":84,"phoneExt":49,"email":85},"CONTACT","+4417525847487","daniela.oehring@plymouth.ac.uk",[87,106],{"facility":88,"status":49,"city":89,"state":90,"zip":91,"country":92,"countryCode":93,"cosmosGeoPoint":94,"geoPoint":99,"contacts":100},"Simon Berry Optometrist","Durham","County Durham","DH1 2HX","United Kingdom","UK",{"type":95,"coordinates":96},"Point",[97,98],-1.57566,54.77676,{"lat":98,"lon":97},[101,105],{"name":102,"role":83,"phone":103,"phoneExt":49,"email":104},"Simon Berry","+44 191 375 7544","simon@simonberry.co.uk",{"name":102,"role":80,"phone":49,"phoneExt":49,"email":49},{"facility":107,"status":49,"city":108,"state":109,"zip":110,"country":92,"countryCode":93,"cosmosGeoPoint":111,"geoPoint":115,"contacts":116},"Centre for Eyecare Excellence, University of Plymouth","Plymouth","Devon","PL4 8AA",{"type":95,"coordinates":112},[113,114],-4.14305,50.37153,{"lat":114,"lon":113},[117,119],{"name":79,"role":83,"phone":118,"phoneExt":49,"email":85},"+44 7584 428035",{"name":79,"role":80,"phone":49,"phoneExt":49,"email":49},{"type":80,"investigatorFullName":121,"investigatorTitle":122,"investigatorAffiliation":5,"oldNameTitle":49,"oldOrganization":49},"Dr Daniela Oehring","Associate Professor in Eye and Vision Science; Chief Investigator",[124],{"name":125,"class":126},"OCUWELL Limited","UNKNOWN","100661677","performance-evaluation-of-the-ocutop-hand-held-corneal-topographer-100661677",false,"NCT07895849","Performance Evaluation of the OCUTOP Hand-held Corneal Topographer","Performance Evaluation of the OCUTOP Corneal Topographer With OCUGRAPH Software: Agreement With Reference Instruments, Repeatability and Safety in an Unselected Adult Clinic Population","OCUTOP","Inclusion Criteria:\n\n1. Aged 18 years or over.\n2. Able to give written informed consent.\n3. Attending the participating clinic for any reason.\n4. Able to sit and fixate on a target for the duration of the measurements.\n\nExclusion Criteria:\n\n1. Unable or unwilling to give informed consent.\n2. Active infection or inflammation of the eye or eyelids, or broken skin around the eye, at the study visit.\n3. Any condition that prevents the eye being kept open or the head being kept steady for the measurements (for example severe blepharospasm or nystagmus).\n4. Contact lens wear on the day of the visit.\n5. Eye surgery within the previous three months.\n6. Known sensitivity to the device's rim material or to the disinfectant wipe used between participants.\n7. Taking part in another clinical investigation that could interfere with this one.",true,"ALL","18 Years",{"count":139,"type":140},150,"ESTIMATED","INTERVENTIONAL",[51],"The OCUTOP is a new hand-held camera that photographs the front of the eye to map the shape of the cornea and to assess the tear film. Before it can be used in eye care it must be compared with the instruments that clinics already use. In this study, adults attending one of two UK eye clinics for an ordinary appointment are invited to have both eyes measured once with the OCUTOP and with the clinic's usual instruments, in a random order, and to complete two short questionnaires. The visit adds about 30 minutes; nothing is put in the eye and no treatment is given. The study measures how closely the OCUTOP agrees with the reference instruments for corneal curvature, tear break-up time and tear meniscus height, how repeatable it is, how often it produces usable images, how acceptable participants and clinicians find it, and whether any adverse events occur.",[145,146,147,148],"Corneal Topography","Dry Eye Syndromes","Keratoconus","Healthy Volunteers",[150,151,152,153],"corneal topography","non-invasive tear break-up time","tear meniscus height","method comparison","NOT_YET_RECRUITING","2026-10-19",{"date":157,"type":158},"2026-10-26","ACTUAL",{"date":160,"type":140},"2027-01",{"date":162,"type":140},"2027-03",{"name":5,"class":6},2]