[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100663608":3},{"organization":4,"outcomesModule":7,"designInfo":30,"detailedDescription":33,"studyPopulation":34,"armGroups":35,"interventions":29,"overallOfficials":29,"centralContacts":42,"locations":51,"responsibleParty":85,"collaborators":29,"id":87,"slug":88,"hasResults":89,"nctId":90,"briefTitle":91,"officialTitle":92,"acronym":29,"eligibilityCriteria":93,"healthyVolunteers":89,"sex":94,"minAge":95,"maxAge":29,"enrollmentInfo":96,"targetDuration":99,"studyType":100,"phases":29,"briefSummary":101,"conditions":102,"keywords":105,"overallStatus":54,"whyStopped":29,"lastUpdateSubmitDate":115,"lastUpdatePostDateStruct":116,"startDateStruct":119,"completionDateStruct":121,"leadSponsor":123,"locationsCount":124},{"fullName":5,"class":6},"Universitas Indonesia","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":29},[9],{"measure":10,"description":11,"timeFrame":12},"Area under the receiver operating characteristic curve (AUROC) of machine learning models for predicting extubation failure","Discrimination of five supervised machine learning models (LightGBM, CatBoost, XGBoost, random forest, SVM) for predicting extubation failure in adult ICU patients on mechanical ventilation, including the difference in AUROC among the five algorithms. Extubation failure is defined as reintubation, tracheostomy, or death from any cause within 7 days after planned extubation. AUROC (unitless, range 0-1) is reported with 95% CI in the internal testing set (RSCM) and the external validation cohort (RS UI).","up to 7 days after planned extubation",[14,17,20,23,26],{"measure":15,"description":16,"timeFrame":12},"Accuracy of machine learning models for predicting extubation failure","Proportion of patients correctly classified (true positives plus true negatives, divided by all patients) by each of the five machine learning models for predicting extubation failure, at a probability threshold determined within the training data by maximizing the F1-score using cross-validated predictions. Reported as a percentage with 95% CI in the internal testing set and the external validation cohort.",{"measure":18,"description":19,"timeFrame":12},"Sensitivity (recall) of machine learning models for predicting extubation failure","Proportion of patients with extubation failure who are correctly identified (true positives divided by true positives plus false negatives) by each of the five machine learning models, at a probability threshold determined within the training data by maximizing the F1-score using cross-validated predictions. Reported as a percentage with 95% CI in the internal testing set and the external validation cohort.",{"measure":21,"description":22,"timeFrame":12},"Positive predictive value (precision) of machine learning models for predicting extubation failure","Proportion of patients predicted to have extubation failure who actually have extubation failure (true positives divided by true positives plus false positives) for each of the five machine learning models, at a probability threshold determined within the training data by maximizing the F1-score using cross-validated predictions. Reported as a percentage with 95% CI in the internal testing set and the external validation cohort.",{"measure":24,"description":25,"timeFrame":12},"Mean absolute SHAP value of candidate predictors for extubation failure (best-performing model)","Contribution of candidate predictors measured before extubation (patient characteristics, clinical condition, mechanical ventilation parameters, and laboratory results) to the predictions of the best-performing model, expressed as mean absolute SHAP value on the predicted probability scale (unitless).",{"measure":27,"description":28,"timeFrame":12},"Permutation importance of candidate predictors for extubation failure","Contribution of candidate predictors measured before extubation to the predictions of each of the five machine learning models, expressed as the mean decrease in AUROC (unitless) when the values of each predictor are randomly permuted in the internal test set.",null,{"allocation":29,"interventionModel":29,"interventionModelDescription":29,"primaryPurpose":29,"observationalModel":31,"timePerspective":32,"maskingInfo":29},"COHORT","PROSPECTIVE","This is a prospective, multicenter, observational cohort study. Extubation and reintubation decisions are made by the attending anesthesiologists as part of routine care and are not informed by the models. The models will be developed only after data collection is complete.\n\nData collection:\n\nCandidate predictors are chosen from previous studies and clinical relevance. They fall into four groups: patient characteristics, clinical condition, mechanical ventilation parameters, and laboratory results. Trained ICU staff and research assistants record them from bedside monitors, ventilator displays, paper and electronic medical records, and family interviews. Patient characteristics and severity scores (APACHE II and SAPS II) are recorded at ICU admission. Before extubation, ventilator parameters are taken within 4 hours, clinical condition within 24 hours, and laboratory results within 48 hours, using the measurement closest to extubation. Patients are followed for 7 days after planned extubation through bedside monitoring and review of medical records after transfer to the ward.\n\nParticipants:\n\nParticipants are enrolled when they receive invasive mechanical ventilation in the ICU, before it is known whether they will have a planned extubation. After enrollment, participants are excluded from the analysis if they die or have a tracheostomy without the breathing tube being removed; stay on a breathing machine for more than 2 weeks without the tube being removed; have an unplanned extubation (the tube was pulled out by the participant or by accident); are transferred to another hospital before extubation or within 7 days after; if they or their family decline further intensive care; or if more than 10% of the candidate predictors are missing. The number of participants enrolled is therefore larger than the number analyzed. Recruitment at the development site continues until the number of participants eligible for analysis reaches the target sample size.\n\nData management:\n\nData are recorded on paper case report forms, entered into an electronic database using study codes without names, medical record numbers, or dates of birth, and stored at the Big Data Center, Indonesia Medical Education and Research Institute (IMERI), Universitas Indonesia. Research assistants periodically check the data for completeness and implausible values. Values that are not measured are left blank during data collection and will be handled in the analysis.\n\nSample size:\n\nThe development cohort target was calculated to estimate sensitivity (80%, precision of 10 percentage points, 95% confidence), assuming a 10% extubation failure rate and 10% dropout. The external validation target was calculated to estimate the extubation failure rate with a 5 percentage point margin of error. The development sample is smaller than formal prediction model sample size criteria would require. The study is therefore exploratory, and the external validation is preliminary.\n\nPlanned analysis:\n\nFive supervised machine learning algorithms will be developed: LightGBM, CatBoost, XGBoost, random forest, and support vector machine. The development cohort will be randomly split, stratified by outcome, into a training set (80%) and a test set (20%). Hyperparameters will be tuned using stratified 5-fold cross-validation within the training set, with AUROC as the optimization metric. The classification threshold will be determined within the training data by maximizing the F1-score using cross-validated predictions. Missing values will be imputed, and class imbalance will be handled using class weighting. Discrimination, calibration, classification performance, and clinical utility (decision curve analysis) will be assessed on the test set and on the external validation cohort, using the final models without modification. Predictor contributions will be assessed with SHAP values for the best-performing model and with permutation importance for all models.\n\nReporting:\n\nThis study follows the TRIPOD+AI reporting guideline (Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis, updated for artificial intelligence).","Adults treated in the intensive care units (ICUs) of two tertiary referral hospitals in Indonesia: Dr. Cipto Mangunkusumo National General Hospital in Jakarta (development cohort) and Universitas Indonesia Hospital in Depok (external validation cohort).",[36,39],{"label":37,"type":29,"description":38,"interventionNames":29},"Development Cohort (RSCM)","Adult ICU patients (≥18 years) on invasive mechanical ventilation via endotracheal tube at Dr. Cipto Mangunkusumo National General Hospital (RSCM), Jakarta, who underwent planned extubation. Enrolled from September 2024; recruitment is expected to be completed in January 2027. Pre-extubation predictors (patient characteristics, clinical condition, ventilator parameters, laboratory results) are recorded prospectively. Outcome: extubation failure, defined as reintubation, tracheostomy, or death from any cause within 7 days after planned extubation. Data are used to develop and internally validate machine learning models (LightGBM, CatBoost, XGBoost, random forest, SVM). No intervention is assigned; extubation follows routine care.",{"label":40,"type":29,"description":41,"interventionNames":29},"External Validation Cohort (RS UI)","Adult ICU patients (≥18 years) on invasive mechanical ventilation via endotracheal tube at Universitas Indonesia Hospital (RS UI) who underwent planned extubation, using the same eligibility criteria, predictors, and 7-day outcome definition as the development cohort. Recruited during a period overlapping with the development cohort (February 2025-February 2026). Data are used only to externally validate the final models developed in the RSCM cohort, without modification. No intervention is assigned; extubation follows routine care.",[43,48],{"name":44,"role":45,"phone":46,"phoneExt":29,"email":47},"Adhrie Sugiarto","CONTACT","+62213157008","adhrie.sugiarto@ui.ac.id",{"name":49,"role":45,"phone":46,"phoneExt":29,"email":50},"Jefferson Hidayat","Jeffersonhidayat@yahoo.com",[52,74],{"facility":53,"status":54,"city":55,"state":56,"zip":57,"country":58,"countryCode":59,"cosmosGeoPoint":60,"geoPoint":65,"contacts":66},"Cipto Mangunkusumo National General Hospital (RSCM)","RECRUITING","Jakarta","DKI Jakarta","10430","Indonesia","ID",{"type":61,"coordinates":62},"Point",[63,64],106.84513,-6.21462,{"lat":64,"lon":63},[67,71],{"name":68,"role":45,"phone":69,"phoneExt":29,"email":70},"Medical and Health Research Ethics Committee of RSCM","021-315-7008","penelitian.anestesirscm2@gmail.com",{"name":72,"role":73,"phone":29,"phoneExt":29,"email":29},"Adhrie Sugiarto, MD, SpAn-KIC","PRINCIPAL_INVESTIGATOR",{"facility":75,"status":76,"city":77,"state":78,"zip":79,"country":58,"countryCode":59,"cosmosGeoPoint":80,"geoPoint":84,"contacts":29},"Universitas Indonesia Hospital (RS UI)","COMPLETED","Depok","West Java","16424",{"type":61,"coordinates":81},[82,83],106.81861,-6.4,{"lat":83,"lon":82},{"type":73,"investigatorFullName":44,"investigatorTitle":86,"investigatorAffiliation":5,"oldNameTitle":29,"oldOrganization":29},"Head of Anesthesiology and Intensive Care Study Program","100663608","predicting-extubation-failure-using-machine-learning-100663608",false,"NCT07918924","Predicting Extubation Failure Using Machine Learning","Prediction of Extubation Failure in Mechanically Ventilated Adult Patients Using a Machine Learning-Based Approach","Inclusion Criteria:\n\n* Aged 18 years or older\n* Receiving invasive mechanical ventilation through a breathing tube in the windpipe (endotracheal tube) in the intensive care unit (ICU)\n\nExclusion Criteria:\n\n\\- Used a breathing machine through a tracheostomy (a surgical opening in the neck) when admitted to the ICU","ALL","18 Years",{"count":97,"type":98},1100,"ESTIMATED","1 Week","OBSERVATIONAL","The goal of this observational study is to predict who will have problems after the breathing tube is removed. Taking out the tube is called extubation, and having these problems is called extubation failure. Participants are adults in the intensive care unit (ICU) who use a breathing machine (ventilator).\n\nThe main questions it aims to answer are:\n\n* How well can computer tools predict problems in the 7 days after the tube is removed?\n* Which information, such as age or blood tests, matters most for the prediction?\n\nExtubation failure means the participant needs the tube put back in, needs a surgical opening in the neck to help breathing, or dies.\n\nResearchers will use machine learning to build the computer tools. Machine learning is a type of artificial intelligence that finds patterns in data. Researchers will compare five types of machine learning to see which works best. They will build the tools with participants from Dr. Cipto Mangunkusumo National General Hospital in Jakarta. They will test the tools with participants from Universitas Indonesia Hospital in Depok.\n\nParticipants get their usual care. Doctors do not use the tools to make treatment decisions. Researchers will:\n\n* Record health information about participants before the tube is removed\n* Follow participants for 7 days after the tube is removed",[103,104],"Extubation Failure","Critical Illness",[106,107,108,109,110,58,111,103,112,113,114],"Machine Learning","Airway Extubation","Ventilator Weaning","Mechanical Ventilation","Intensive Care Units","Clinical Prediction Model","External Validation","Artificial Intelligence","Prospective Cohort","2026-11-18",{"date":117,"type":118},"2026-11-23","ACTUAL",{"date":120,"type":118},"2024-09-04",{"date":122,"type":98},"2027-01-31",{"name":5,"class":6},2]