[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100664585":3},{"organization":4,"outcomesModule":7,"designInfo":55,"detailedDescription":54,"studyPopulation":54,"armGroups":64,"interventions":77,"overallOfficials":87,"centralContacts":54,"locations":92,"responsibleParty":126,"collaborators":128,"id":131,"slug":132,"hasResults":133,"nctId":134,"briefTitle":135,"officialTitle":136,"acronym":137,"eligibilityCriteria":138,"healthyVolunteers":133,"sex":139,"minAge":140,"maxAge":54,"enrollmentInfo":141,"targetDuration":54,"studyType":144,"phases":145,"briefSummary":147,"conditions":148,"keywords":153,"overallStatus":94,"whyStopped":54,"lastUpdateSubmitDate":159,"lastUpdatePostDateStruct":160,"startDateStruct":163,"completionDateStruct":165,"leadSponsor":167,"locationsCount":168},{"fullName":5,"class":6},"AdventHealth","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":54},[9],{"measure":10,"description":11,"timeFrame":12},"Elbow Flexion-Extension Arc of Motion","Total arc of elbow flexion-extension in degrees (maximum flexion minus loss of extension), measured with a goniometer. The primary comparison between groups is at 24 months postoperatively. Measurements at earlier time points are reported to describe recovery over time.","Baseline, 3 months, 6 months, 12 months, and 24 months postoperatively",[14,18,22,25,28,32,35,38,41,44,47,50],{"measure":15,"description":16,"timeFrame":17},"Forearm Rotation Arc of Motion","Total arc of forearm rotation in degrees (maximum pronation plus maximum supination), measured with a goniometer.","Baseline, 3, 6, 12, and 24 months postoperatively",{"measure":19,"description":20,"timeFrame":21},"Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) Score","The QuickDASH is an 11-item patient-reported questionnaire assessing upper extremity function and symptoms. Scores range from 0 to 100, and higher scores indicate greater disability (worse outcome).","Baseline (preoperative), 3, 6, 12, and 24 months postoperatively",{"measure":23,"description":24,"timeFrame":21},"Mayo Elbow Performance Score (MEPS)","The MEPS assesses elbow pain, range of motion, stability, and ability to perform daily activities. Scores range from 0 to 100, and higher scores indicate better elbow function (better outcome).",{"measure":26,"description":27,"timeFrame":17},"Visual Analog Scale (VAS) for Pain","Participants mark their pain intensity on a continuous line scored from 0 (no pain) to 10 (worst imaginable pain). Higher scores indicate worse pain.",{"measure":29,"description":30,"timeFrame":31},"Number of Participants Receiving Corticosteroid Injections","Number of participants who receive one or more corticosteroid injections to the operative elbow after radial head arthroplasty.","Through 24 months postoperatively",{"measure":33,"description":34,"timeFrame":31},"Number of Participants Requiring Reoperation","Number of participants who undergo any secondary surgical procedure on the operative elbow after the index radial head arthroplasty, including stiffness release and implant removal.",{"measure":36,"description":37,"timeFrame":31},"Number of Participants With Radiographic Implant Loosening","Intramedullary stem loosening on standard elbow radiographs.",{"measure":39,"description":40,"timeFrame":31},"Number of Participants With Radiographic Implant Subsidence","Implant subsidence on standard elbow radiographs compared with immediate postoperative radiographs.",{"measure":42,"description":43,"timeFrame":31},"Number of Participants With Radial Neck Resorption","Radial neck bone resorption (stress shielding) on standard elbow radiographs.",{"measure":45,"description":46,"timeFrame":31},"Number of Participants With Heterotopic Ossification","Heterotopic ossification on standard elbow radiographs.",{"measure":48,"description":49,"timeFrame":31},"Number of Participants With Surgical or Implant-Related Complications","Number of participants with one or more complications related to the surgery or implant, including implant loosening, infection, stiffness, nerve injury, instability, or implant failure.",{"measure":51,"description":52,"timeFrame":53},"Grip Strength","Maximum grip strength of the operative hand in kilograms, measured with a hand-held dynamometer.","3, 6, 12, and 24 months postoperatively",null,{"allocation":56,"interventionModel":57,"interventionModelDescription":58,"primaryPurpose":59,"observationalModel":54,"timePerspective":54,"maskingInfo":60},"RANDOMIZED","PARALLEL","Parallel Assignment - participants randomized 1:1 to press-fit or loose-fit radial head arthroplasty","TREATMENT",{"masking":61,"maskingDescription":54,"whoMasked":62},"SINGLE",[63],"PARTICIPANT",[65,71],{"label":66,"type":67,"description":68,"interventionNames":69},"Press-Fit Radial Head Arthroplasty","EXPERIMENTAL","Patients undergoing primary RHA with a press-fit (grit-blasted or porous-coated, ingrowth-dependent) radial head implant - Skeletal Dynamics radial head prosthesis.",[70],"Device: Skeletal Dynamics Radial Head (Press-Fit)",{"label":72,"type":73,"description":74,"interventionNames":75},"Loose-Fit Radial Head Arthroplasty","ACTIVE_COMPARATOR","Patients undergoing primary RHA with a loose-fit (smooth-stem spacer) radial head implant - Stryker radial head prosthesis.",[76],"Device: Stryker Radial Head (Loose-Fit).",[78,83],{"type":79,"name":80,"description":81,"armGroupLabels":82,"otherNames":54},"DEVICE","Skeletal Dynamics Radial Head (Press-Fit)","Skeletal Dynamics Radial Head (Press-Fit). Surgical placement of a press-fit radial head prosthesis sized for interference fit within the radial canal.",[66],{"type":79,"name":84,"description":85,"armGroupLabels":86,"otherNames":54},"Stryker Radial Head (Loose-Fit).","Surgical placement of a smooth-stem radial head prosthesis functioning as a spacer permitting rotation and micromotion.",[72],[88],{"name":89,"affiliation":90,"role":91},"Amir Kachooei, MD PhD","Rothman Orthopedics at AdventHealth","PRINCIPAL_INVESTIGATOR",[93,111],{"facility":5,"status":94,"city":95,"state":96,"zip":97,"country":98,"countryCode":99,"cosmosGeoPoint":100,"geoPoint":105,"contacts":106},"RECRUITING","Orlando","Florida","32827","United States","US",{"type":101,"coordinates":102},"Point",[103,104],-81.37924,28.53834,{"lat":104,"lon":103},[107],{"name":89,"role":108,"phone":109,"phoneExt":54,"email":110},"CONTACT","(844) 407-4070","amir.kachooei@rothmanortho.com",{"facility":112,"status":94,"city":113,"state":54,"zip":54,"country":114,"countryCode":115,"cosmosGeoPoint":116,"geoPoint":120,"contacts":121},"La Paz","Madrid","Spain","ES",{"type":101,"coordinates":117},[118,119],-3.70256,40.4165,{"lat":119,"lon":118},[122],{"name":123,"role":108,"phone":124,"phoneExt":54,"email":125},"Raul Barco, MD PhD","+34 917 27 70 00","atepac.hulp@salud.madrid.org",{"type":127,"investigatorFullName":54,"investigatorTitle":54,"investigatorAffiliation":54,"oldNameTitle":54,"oldOrganization":54},"SPONSOR",[129],{"name":130,"class":6},"Hospital Universitario La Paz","100664585","press-fit-vs-loose-fit-radial-head-arthroplasty-100664585",false,"NCT07932704","Press-Fit vs Loose-Fit Radial Head Arthroplasty","Outcomes of Press-Fit vs Loose-Fit Radial Head Implants: A Prospective Single-Blinded Randomized Control Trial With a Minimum Follow-Up of 2 Years","PROFIT","Inclusion Criteria:\n\n1. Age 18 years or older.\n2. Scheduled for primary RHA.\n3. Willing and able to provide written informed consent.\n4. Willing and able to comply with post-operative follow-up visits at 3 months, 6 months, 1 year, and 2 years.\n5. No concurrent elbow procedures such as ligament reconstruction or additional joint resurfacing at the time of RHA.\n6. No prior history of revision RHA.\n7. RHA to be performed using press-fit or loose-fit implants (no other fixation methods included).\n8. Must be able to complete PROs independently.\n\nExclusion Criteria:\n\n1. Diagnosed with any significant comorbidities that could interfere with rehabilitation or study participation, including but not limited to:\n\n   * Severe osteoarthritis affecting elbow function\n   * Rheumatoid arthritis or other autoimmune disorders affecting musculoskeletal function\n   * Full-thickness cartilage lesion in the elbow joint\n   * Neurological or vascular complications\n   * Neuromuscular disorders affecting movement or coordination\n   * Neurocognitive conditions impacting study participation\n   * Chronic infections or immunodeficiency conditions\n   * Uncontrolled diabetes\n   * Cardiovascular diseases (e.g., congestive heart failure, ischemic heart disease)\n   * Severe chronic obstructive pulmonary disease (COPD) or other significant respiratory conditions\n   * Renal insufficiency or chronic kidney disease (stage 3 or higher)\n   * Obesity with a body mass index (BMI) \\> 40\n   * Active cancer treatment or history of cancer within the past 5 years\n2. Known allergy or contraindication to any surgical materials used in the radial head implant procedure.\n3. Patients currently participating in another clinical trial that may interfere with this study's outcomes.\n4. Risk factors for poor implant integration and healing, including:\n\n   * Active alcohol or substance dependence\n   * Nicotine\u002Ftobacco use\n   * Chronic corticosteroid use\n   * Recent chemotherapy\n5. Any condition that, in the opinion of the principal investigator, would make participation in the study unsafe or not in the patient's best interest.","ALL","18 Years",{"count":142,"type":143},130,"ESTIMATED","INTERVENTIONAL",[146],"NA","This study compares two types of artificial implants used to replace a broken part of the elbow (the radial head) when the bone is too damaged to repair. One implant (press-fit) is designed to grip the bone tightly so bone grows into it and holds it in place. The other implant (loose-fit) has a smooth stem that sits loosely in the bone and is meant to move slightly. Both implants are already approved and widely used; doctors do not yet know if one works better than the other. People taking part are placed by chance into one of the two implant groups. The study will follow them for at least 2 years to see how far they can bend and straighten the elbow, how much pain they have, how well the elbow works in daily life, whether the implant stays in good position on X-rays, and whether any further surgery is needed.",[149,150,151,152],"Radial Head Fractures","Elbow Fractures","Elbow Dislocation","Elbow Injuries and Disorders",[154,155,156,157,158],"radial head arthroplasty","Press-Fit Implant","Loose-Fit Implant","Elbow","Radial Head Prosthesis","2026-11-09",{"date":161,"type":162},"2026-11-12","ACTUAL",{"date":164,"type":162},"2026-01-16",{"date":166,"type":143},"2031-09",{"name":5,"class":6},2]