[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100531390":3},{"organization":4,"outcomesModule":7,"designInfo":43,"detailedDescription":53,"studyPopulation":42,"armGroups":54,"interventions":67,"overallOfficials":77,"centralContacts":81,"locations":89,"responsibleParty":110,"collaborators":112,"id":116,"slug":117,"hasResults":118,"nctId":119,"briefTitle":120,"officialTitle":121,"acronym":122,"eligibilityCriteria":123,"healthyVolunteers":118,"sex":124,"minAge":125,"maxAge":126,"enrollmentInfo":127,"targetDuration":42,"studyType":130,"phases":131,"briefSummary":133,"conditions":134,"keywords":136,"overallStatus":92,"whyStopped":42,"lastUpdateSubmitDate":141,"lastUpdatePostDateStruct":142,"startDateStruct":145,"completionDateStruct":147,"leadSponsor":149,"locationsCount":150},{"fullName":5,"class":6},"University Medical Center Groningen","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":42},[9],{"measure":10,"description":11,"timeFrame":12},"To compare the efficacy of repeat pulmonary vein isolation (PVI) with PFA or point-by-point RF ablation.","12-month incidence of AF\u002FAFl\u002FAT recurrence.","12 months",[14,17,21,24,27,30,33,35,38],{"measure":10,"description":15,"timeFrame":16},"24-month incidence of AF\u002FAFl\u002FAT recurrence.","24 months",{"measure":18,"description":19,"timeFrame":20},"Repeat PVI within 12 and 24 months of randomization","Repeat PVI","12 and 24 months",{"measure":22,"description":23,"timeFrame":20},"AF burden with and without 3 months blanking period","Proportion of cumulative time in AF divided by the total time accrued over follow-up",{"measure":25,"description":26,"timeFrame":20},"Change in quality of life","As measured by EuroQol-5D-5L questionnaire",{"measure":28,"description":29,"timeFrame":20},"Change in quality of life as affected by AF","As measured by AF Effect On Quality-Of-Life (AFEQT) questionnaire",{"measure":31,"description":32,"timeFrame":20},"AF hospitalisation \u002F urgent visit","Hospitalization\u002Furgent visit for atrial fibrillation",{"measure":34,"description":34,"timeFrame":20},"Cost-effectiveness",{"measure":36,"description":36,"timeFrame":37},"Rate of ischemic stroke","12 and 24 months (efficacy)",{"measure":39,"description":40,"timeFrame":41},"Complications of ablation","Death, stroke, pericarditis, cardiac tamponade, vascular access complications etc.","0-30 days post ablation",null,{"allocation":44,"interventionModel":45,"interventionModelDescription":46,"primaryPurpose":47,"observationalModel":42,"timePerspective":42,"maskingInfo":48},"RANDOMIZED","PARALLEL","patients will be randomised to PFA or RFA for redo PVI","TREATMENT",{"masking":49,"maskingDescription":50,"whoMasked":51},"SINGLE","Patients know their treatment arm. All endpoints will be adjudicated by a blinded endpoint committee.",[52],"OUTCOMES_ASSESSOR","All participating patients are required to provide written (or equivalent) informed consent, indicated by a dated signature of the subject or legal representative. The consent process must comply with applicable national regulations and use language understandable by the patient.\n\nThe study will be conducted at 6 clinical centres\u002Finvestigational sites across the Netherlands. Patients will be randomized (1:1) into a PFA or point-by-point RF ablation arm. Randomization will occur prior to the ablation procedure. A implantable cardiac monitor will be implanted in all randomised patients one month before ablation to accurately monitor any AF\u002Fatrial flutter (AFL)\u002F atrial tachycardia (AT) recurrence. Treatment allocation will be processed through the Dutch 'National Heart Registry' (NHR) data platform.\n\nPatients randomized to both arms of the study will be evaluated for PV isolation at the start of the ablation procedure. If PV reconnection is identified in patients in the point-by-point RF arm, re-ablation will occur according to the study protocol. Patients in the PFA arm will have PV reconnection determined using the FARAWAVE catheter. Those with no PV reconnection (100% PV isolation\u002Fdurable PVI) will be followed in an observational registry.\n\nThe PFA ablation arm involves the use of the Farastar generator system, Farawave ablation catheter, and Faradrive steering catheter for the procedure. The RF point-by-point ablation arm (control) involves RF ablation following standard practice.",[55,61],{"label":56,"type":57,"description":58,"interventionNames":59},"Radiofrequency ablation","ACTIVE_COMPARATOR","In this group, patients will undergo the acquisition of a 3D high-density map. If pulmonary vein (PV) reconnection is identified, radiofrequency ablation (RFA) will be employed for pulmonary vein isolation (PVI). Should PV reconnection not be detected, the operator will have the discretion to determine the necessary ablation strategies. Patients falling into this category will be included in a concurrent registry.",[60],"Device: pulmonary vein isolation with RFA",{"label":62,"type":63,"description":64,"interventionNames":65},"Pulsed field ablation","EXPERIMENTAL","In this group, pulmonary vein (PV) reconnection is identified by the FARAWAVE system. If reconnection is observed, pulsed field ablation (PFA) will be employed for pulmonary vein isolation (PVI). Should PV reconnection not be detected, the operator will have the discretion to determine the necessary ablation strategies. Patients falling into this category will be included in a concurrent registry.",[66],"Device: pulmonary vein isolation with PFA",[68,73],{"type":69,"name":70,"description":71,"armGroupLabels":72,"otherNames":42},"DEVICE","pulmonary vein isolation with RFA","Patients randomised to RFA will undergo PVI with point-by-point RFA.",[56],{"type":69,"name":74,"description":75,"armGroupLabels":76,"otherNames":42},"pulmonary vein isolation with PFA","Patients randomised to PFA will undergo PVI with PFA.",[62],[78],{"name":79,"affiliation":5,"role":80},"Yuri Blaauw, Dr.","PRINCIPAL_INVESTIGATOR",[82,86],{"name":79,"role":83,"phone":84,"phoneExt":42,"email":85},"CONTACT","+31503616161","y.blaauw01@umcg.nl",{"name":87,"role":83,"phone":84,"phoneExt":42,"email":88},"Nick van Vreeswijk, drs.","n.l.van.vreeswijk@umcg.nl",[90],{"facility":91,"status":92,"city":93,"state":94,"zip":95,"country":96,"countryCode":97,"cosmosGeoPoint":98,"geoPoint":103,"contacts":104},"UMCG","RECRUITING","Groningen","Provincie Groningen","9713GZ","Netherlands","NL",{"type":99,"coordinates":100},"Point",[101,102],6.56667,53.21917,{"lat":102,"lon":101},[105,108],{"name":106,"role":83,"phone":107,"phoneExt":42,"email":85},"Yuri Blaauw, MD, PhD","0503616161",{"name":109,"role":83,"phone":107,"phoneExt":42,"email":88},"Nick van Vreeswijk, MD",{"type":111,"investigatorFullName":42,"investigatorTitle":42,"investigatorAffiliation":42,"oldNameTitle":42,"oldOrganization":42},"SPONSOR",[113],{"name":114,"class":115},"Boston Scientific Corporation","INDUSTRY","100531390","pulsed-field-ablation-versus-conventional-radiofrequency-catheter-ablation-for-repeat-pvi-in-patients-with-paroxysmal-af-100531390",false,"NCT06199180","Pulsed Field Ablation Versus Conventional Radiofrequency Catheter Ablation for Repeat PVI in Patients With Paroxysmal AF","Pulsed Field Ablation Versus Conventional Radiofrequency Catheter Ablation for Repeat","REPEAT-AF","Subjects who meet all of the following inclusion criteria at screening will be eligible for enrolment:\n\n* Patient had 1 previous PVI with either cryoballoon, RF ablation or PFA\n* Index PVI occurred within \\\u003C5 years prior to enrolment\n* Documented AF recurrence \\>30 seconds\n* Symptomatic AF\n* Paroxysmal AF\n* Age \\>18 and \\\u003C80 years\n* Willing and capable to provide informed consent\n* Able and willing to participate in all examinations and follow-up visits and tests associated with this clinical study\n\nSubjects who meet ANY of the following exclusion criteria will be excluded from the study:\n\n* Persistent AF (by diagnosis of duration \\>7 days)\n* Concomitant\u002F prior diagnosis for atrial tachycardia (AT) and\u002For atrial flutter (AFl). Note typical cavotricuspid isthmus dependent flutter is not an exclusion criterium.\n* Underwent additional ablations outside the pulmonary veins during index AF ablation\n* AF secondary to electrolyte imbalance, thyroid disease, alcohol abuse, or other reversible\u002Fnon-cardiac causes\n* Contraindication to, or unwillingness to use, systematic anticoagulation\n* Left ventricular ejection fraction (LVEF) \\\u003C30% as documented by transthoracic echo (TTE) (within \\\u003C3 months prior)\n* Left atrial volume index \\>60 ml\u002Fm2\n* Clinically significant arrhythmias other than AF\n* Previous surgery for AF\n* New York Heart Association (NYHA) Functional Class III or IV\n* Presence of intramural thrombus, tumour or other abnormality that precludes safe catheter introduction or manipulation\n* BMI \\>35 kg\u002Fm2\n* Significant or symptomatic hypotension, bradycardia, or chronotropic incompetence\n* Chronic renal insufficiency of \\\u003C15 mL\u002Fmin\u002F1.73 m2 or any history of renal dialysis, or history of renal transplant\n* Hemodynamically significant valvular disease\n* Presence of patent foramen ovale (PFO) or atrial septal defect (ASD) closure device\n* History of abnormal bleeding and\u002For clotting disorder\n* History of rheumatic fever\n* Severe lung disease, pulmonary hypertension, or any lung disease. Only if involving abnormal blood gases or significant dyspnoea\n* Clinically significant systemic infection or sepsis\n* Life expectancy \\\u003C1 year\n* Sensitivity to contrast media not controlled by pre-medication\n* Any of the following within the 3 months prior to enrolment:\n\n  * Myocardial infarction\n  * Unstable angina\n  * Percutaneous coronary intervention\n  * Heart failure hospitalization\n  * Stroke or TIA\n  * Significant bleeding\n  * Pericarditis\u002Feffusions\n  * Left atrial thrombus\n* Coronary artery bypass grafting\u002Fatriotomy within 6 months prior\n* Organ or haematologic transplant, or currently being evaluated for an organ transplant\n* Women who are pregnant or breastfeeding","ALL","18 Years","80 Years",{"count":128,"type":129},154,"ESTIMATED","INTERVENTIONAL",[132],"NA","Various methods exist for performing pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF), including thermal ablation and pulse-field ablation (PFA). However, in cases requiring a second PVI for recurrent AF, radiofrequency ablation (RFA) is utilized in nearly 95% of instances post-acquiring a 3D high-density map from the left atrium (LA). Up to 85% of patients experiencing recurrent AF after the initial PVI exhibit pulmonary vein (PV) reconnections, often identified as the cause of AF.\n\nPFA has demonstrated its safety and efficiency compared to RFA as a swift technique for performing ablation. Yet, whether PFA or RFA stands out as superior or safer when applied for a second PVI remains unclear, as no randomized controlled trial has investigated this comparison. The proposed REPEAT-AF trial aims to randomize 154 AF patients experiencing recurrent AF after the initial PVI, assigning them in a 1:1 ratio to either RFA or PFA. Each patient will receive an implantable cardiac monitor to precisely detect any AF recurrences.",[135],"Atrial Fibrillation Recurrent",[137,138,139,140],"pulmonary vein isolation","pulsed field ablation","radiofrequency ablation","implantable cardiac monitor","2026-11-24",{"date":143,"type":144},"2026-11-25","ACTUAL",{"date":146,"type":144},"2024-09-20",{"date":148,"type":129},"2029-01",{"name":5,"class":6},1]