[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100530770":3},{"organization":4,"outcomesModule":7,"designInfo":21,"detailedDescription":20,"studyPopulation":20,"armGroups":27,"interventions":34,"overallOfficials":40,"centralContacts":44,"locations":54,"responsibleParty":71,"collaborators":75,"id":81,"slug":82,"hasResults":83,"nctId":84,"briefTitle":85,"officialTitle":86,"acronym":87,"eligibilityCriteria":88,"healthyVolunteers":89,"sex":90,"minAge":91,"maxAge":92,"enrollmentInfo":93,"targetDuration":20,"studyType":96,"phases":97,"briefSummary":98,"conditions":99,"keywords":101,"overallStatus":57,"whyStopped":20,"lastUpdateSubmitDate":104,"lastUpdatePostDateStruct":105,"startDateStruct":108,"completionDateStruct":110,"leadSponsor":112,"locationsCount":113},{"fullName":5,"class":6},"University Hospital Heidelberg","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":20,"otherOutcomes":20},[9,13,17],{"measure":10,"description":11,"timeFrame":12},"Oral-Health-Related Quality of Life","Improvement of Oral-Health-Related Quality of Life (OHRQoL) after incorporation of removable partial dentures made of PEEK (PEEK-RPDs) by using a short version of the validated \"Oral Health Impact Profile\" questionnaire with 14 questions (OHIP-G 14). A precise evaluation is obtained by adding up the 14 items with their frequency (\"never\"=0, \"hardly\"=1, \"now and then\"=2, \"often\"=3 and \"very often\"=4) up to a total value. This value can range from 0 (no limitation of OHRQL) to 56 (severe limitation of OHRQoL). These data are collected before treatment and 3 months after insertion of the PEEK-RPDs.","3 months",{"measure":14,"description":15,"timeFrame":16},"Biological complications","Biological complications (intolerances, damage to the abutment teeth and\u002For the periodontium, survival of abutment teeth) after incorporation of PEEK-RPDs. Measurement tool: Study report form. These data are collected half-yearly after insertion of the PEEK-RPDs.","3 years",{"measure":18,"description":19,"timeFrame":16},"Technical complications","Technical complications (clasp fractures, denture defects) after incorporation of PEEK-RPDs. Measurement tool: Study report form. These data are collected half-yearly after insertion of the PEEK-RPDs.",null,{"allocation":22,"interventionModel":23,"interventionModelDescription":20,"primaryPurpose":24,"observationalModel":20,"timePerspective":20,"maskingInfo":25},"NA","SINGLE_GROUP","TREATMENT",{"masking":26,"maskingDescription":20,"whoMasked":20},"NONE",[28],{"label":29,"type":30,"description":31,"interventionNames":32},"PEEK-RPDs","EXPERIMENTAL","Participants with removable partial dentures made of PEEK",[33],"Device: Removable Partial Denture",[35],{"type":36,"name":37,"description":38,"armGroupLabels":39,"otherNames":20},"DEVICE","Removable Partial Denture","Integration of removable partial dentures made of PEEK for the treatment of tooth loss.",[29],[41],{"name":42,"affiliation":5,"role":43},"Peter Rammelsberg, Prof. \u002F Head","STUDY_CHAIR",[45,50],{"name":46,"role":47,"phone":48,"phoneExt":20,"email":49},"Thomas Stober, Assoc. Prof.","CONTACT","004962215636048","thomas.stober@med.uni-heidelberg.de",{"name":51,"role":47,"phone":52,"phoneExt":20,"email":53},"Bohn Eva-Marie, Assis. Prof.","004962215638665","eva-marie.bohn@med.uni-heidelberg.de",[55],{"facility":56,"status":57,"city":58,"state":20,"zip":59,"country":60,"countryCode":61,"cosmosGeoPoint":62,"geoPoint":67,"contacts":68},"University Hospital Heidelberg, Department of Prosthodontics","RECRUITING","Heidelberg","69126","Germany","DE",{"type":63,"coordinates":64},"Point",[65,66],8.69079,49.40768,{"lat":66,"lon":65},[69,70],{"name":46,"role":47,"phone":48,"phoneExt":20,"email":49},{"name":51,"role":47,"phone":52,"phoneExt":20,"email":53},{"type":72,"investigatorFullName":73,"investigatorTitle":74,"investigatorAffiliation":5,"oldNameTitle":20,"oldOrganization":20},"PRINCIPAL_INVESTIGATOR","Thomas Stober","Prof. Dr.",[76,78],{"name":77,"class":6},"Medical University Innsbruck",{"name":79,"class":80},"Merz Dental GmbH","UNKNOWN","100530770","removable-partial-dentures-made-of-peek-100530770",false,"NCT06191107","Removable Partial Dentures Made of PEEK","Clinical Performance of Removable Partial Dentures With Clasps Made of PEEK","KLAP","Inclusion Criteria:\n\n* Indication for a clasp-anchored removable partial denture\n\nExclusion Criteria:\n\n* Minors and adults unable to give consent\n* Pregnancy or breastfeeding\n* Severe general illnesses\n* Allergies or other intolerances to one of the materials used (PEEK, PMMA)\n* Suspicion of lack of compliance",true,"ALL","18 Years","75 Years",{"count":94,"type":95},50,"ESTIMATED","INTERVENTIONAL",[22],"As part of the clinical study, 25 patients each were provided with removable partial dentures with clasps made of PEEK in two centres (University Hospital Heidelberg, Department of Prosthodontics and University Hospital for Dental Prosthetics Innsbruck). The patients were examined over a period of 3 years for the number and type of technical or biological complications and questioned about their oral health-related quality of life.",[100],"Tooth Loss",[37,102,103],"Polyetheretherketone","Oral Health Related Quality of Life","2024-05-10",{"date":106,"type":107},"2024-05-13","ACTUAL",{"date":109,"type":107},"2024-02-12",{"date":111,"type":95},"2028-11",{"name":5,"class":6},1]