[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100665623":3},{"organization":4,"outcomesModule":7,"designInfo":83,"detailedDescription":82,"studyPopulation":82,"armGroups":88,"interventions":95,"overallOfficials":103,"centralContacts":107,"locations":113,"responsibleParty":129,"collaborators":131,"id":135,"slug":136,"hasResults":137,"nctId":138,"briefTitle":139,"officialTitle":140,"acronym":82,"eligibilityCriteria":141,"healthyVolunteers":137,"sex":142,"minAge":143,"maxAge":82,"enrollmentInfo":144,"targetDuration":82,"studyType":147,"phases":148,"briefSummary":149,"conditions":150,"keywords":82,"overallStatus":115,"whyStopped":82,"lastUpdateSubmitDate":156,"lastUpdatePostDateStruct":157,"startDateStruct":160,"completionDateStruct":162,"leadSponsor":164,"locationsCount":165},{"fullName":5,"class":6},"Seoul National University Hospital","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":22,"otherOutcomes":82},[9,13,16,19],{"measure":10,"description":11,"timeFrame":12},"Change in Blood Pressure From Before to After Functional Assessment","Systolic and Diastolic blood pressure will be measured in millimeters of mercury (mmHg) before and after completion of the functional assessment, which includes gait and balance tests performed under the designated orthosis conditions.","Immediately before and after the functional assessment at each study visit",{"measure":14,"description":15,"timeFrame":12},"Change in Heart Rate From Before to After Functional Assessment","Heart rate will be measured in beats per minute (bpm) before and after completion of the functional assessment, which includes gait and balance tests performed under the designated orthosis conditions.",{"measure":17,"description":18,"timeFrame":12},"Change in Perceived Exertion From Before to After Functional Assessment","Perceived exertion will be assessed using the Borg Scale before and after completion of the functional assessment. Higher scores indicate greater perceived exertion.",{"measure":20,"description":21,"timeFrame":12},"Change in Pain Intensity From Before to After Functional Assessment","Pain intensity will be assessed using the Numeric Rating Scale (NRS) before and after completion of the functional assessment. Scores range from 0 to 10, with higher scores indicating greater pain intensity.",[23,27,30,33,36,39,42,45,48,52,55,58,61,64,67,70,73,76,79],{"measure":24,"description":25,"timeFrame":26},"6-Minute Walk Test","To evaluate walking endurance and functional mobility by measuring the maximum walking distance achieved within six minutes.","1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)",{"measure":28,"description":29,"timeFrame":26},"10-Meter Walk Test","To assess gait speed and short-distance walking performance under different orthosis conditions.",{"measure":31,"description":32,"timeFrame":26},"20-Meter Walk Test","To assess walking speed and gait performance over a longer walking distance.",{"measure":34,"description":35,"timeFrame":26},"Surface Electromyography","To evaluate lower-limb muscle activation patterns during walking using surface electromyography (sEMG).",{"measure":37,"description":38,"timeFrame":26},"Static One-Leg Standing Balance Test","To evaluate static balance ability by measuring the duration participants can maintain single-leg standing.",{"measure":40,"description":41,"timeFrame":26},"Postural Sway","To assess postural stability during quiet standing using center of pressure (COP)-based balance measurements.",{"measure":43,"description":44,"timeFrame":26},"Passive Joint Position Reproduction Test","To evaluate proprioceptive accuracy by measuring passive knee joint position reproduction error.",{"measure":46,"description":47,"timeFrame":26},"Active Joint Position Reproduction Test","To evaluate proprioceptive accuracy by measuring active knee joint position reproduction error.",{"measure":49,"description":50,"timeFrame":51},"Participant Satisfaction","To assess participant satisfaction, comfort, perceived usability, and overall acceptance of the wearable orthosis.","Immediately post-brace activation (power on)",{"measure":53,"description":54,"timeFrame":26},"Gait Speed","Gait speed measured using the GAITRite system, reported in meters per second (m\u002Fs).",{"measure":56,"description":57,"timeFrame":26},"Cadence","Cadence measured using the GAITRite system, reported in steps per minute (steps\u002Fmin).",{"measure":59,"description":60,"timeFrame":26},"Step Time","Step time measured using the GAITRite system, reported in seconds (s).",{"measure":62,"description":63,"timeFrame":26},"Step Length","Step length measured using the GAITRite system, reported in centimeters (cm).",{"measure":65,"description":66,"timeFrame":26},"Stride Time","Stride time measured using the GAITRite system, reported in seconds (s).",{"measure":68,"description":69,"timeFrame":26},"Stride Length","Stride length measured using the GAITRite system, reported in centimeters (cm).",{"measure":71,"description":72,"timeFrame":26},"Single Support Time","Single support time measured using the GAITRite system, reported in seconds (s).",{"measure":74,"description":75,"timeFrame":26},"Double Support Time","Double support time measured using the GAITRite system, reported in seconds (s).",{"measure":77,"description":78,"timeFrame":26},"Stance Time","Stance time measured using the GAITRite system, reported in seconds (s).",{"measure":80,"description":81,"timeFrame":26},"Swing Time","Swing time measured using the GAITRite system, reported in seconds (s).",null,{"allocation":84,"interventionModel":85,"interventionModelDescription":82,"primaryPurpose":6,"observationalModel":82,"timePerspective":82,"maskingInfo":86},"NA","SINGLE_GROUP",{"masking":87,"maskingDescription":82,"whoMasked":82},"NONE",[89],{"label":90,"type":91,"description":92,"interventionNames":93},"Integrated Fabric-Type Orthosis Evaluation","EXPERIMENTAL","Participants will undergo gait, balance, proprioception, and electromyography assessments under three conditions: without the orthosis, with the orthosis powered off, and with the orthosis powered on. The wearable fabric-type orthosis provides muscle-mimicking lower-limb assistance and proprioception-enhancing vibrotactile stimulation for gait and balance support in older adults.",[94],"Device: Integrated Fabric-Type Orthosis",[96],{"type":97,"name":98,"description":99,"armGroupLabels":100,"otherNames":101},"DEVICE","Integrated Fabric-Type Orthosis","A wearable fabric-type lower-limb orthosis integrating muscle-mimicking actuation and proprioception-enhancing vibrotactile stimulation. The device is designed to assist knee and ankle movements during gait and balance activities in older adults with gait and balance impairments. Participants will be evaluated under three conditions: without the orthosis, with the orthosis powered off, and with the orthosis powered on.",[90],[102],"Soft Exosuit",[104],{"name":105,"affiliation":5,"role":106},"hyungik shin, prof","STUDY_DIRECTOR",[108],{"name":109,"role":110,"phone":111,"phoneExt":82,"email":112},"junghyun kim, prof","CONTACT","82+1088632341","kiking0@naver.com",[114],{"facility":5,"status":115,"city":116,"state":117,"zip":118,"country":119,"countryCode":82,"cosmosGeoPoint":120,"geoPoint":125,"contacts":126},"RECRUITING","Seoul","Jongno","03080","South Korea",{"type":121,"coordinates":122},"Point",[123,124],126.9784,37.566,{"lat":124,"lon":123},[127],{"name":109,"role":110,"phone":128,"phoneExt":82,"email":112},"82+1059657182",{"type":130,"investigatorFullName":82,"investigatorTitle":82,"investigatorAffiliation":82,"oldNameTitle":82,"oldOrganization":82},"SPONSOR",[132],{"name":133,"class":134},"Ministry of Science and ICT, Republic of Korea","OTHER_GOV","100665623","safety-and-feasibility-of-an-integrated-fabric-type-orthosis-for-gait-and-balance-improvement-in-geriatric-patients-100665623",false,"NCT07945288","Safety and Feasibility of an Integrated Fabric-Type Orthosis for Gait and Balance Improvement in Geriatric Patients","Safety and Feasibility of an Integrated Fabric- Type Orthosis With Muscle-Mimicking and Proprioception-Enhancing Functions for Improving Gait and Balance in Geriatric Patients: Pilot Clinical Trial","Inclusion Criteria:\n\nEligibility for participation in the study requires that all the following criteria are met:\n\n1. Age: Participants must be 65 years of age or older.\n2. Comprehension and Compliance: Able to fully understand and comply with the instructions and study procedures.\n3. Mobility-Impacting Conditions: Must have at least one of the following conditions affecting mobility: (1)Sarcopenia:\n\n   * Muscle Strength: Handgrip strength of \\\u003C28 kg for men and \\\u003C18 kg for women.\n   * Muscle Function: Short Physical Performance Battery (SPPB) score of 8 or less.\n   * Muscle Mass: Bioelectrical impedance analysis (BIA) showing muscle mass \\\u003C7.0 kg\u002Fm² for men and \\\u003C5.7 kg\u002Fm² for women. (2)Diabetes:\n   * Diagnosed distal symmetric polyneuropathy.\n   * Sensory impairments in toes or feet. (3)Knee Osteoarthritis:\n   * Kellgren-Lawrence grade ≥2.\n   * Persistent pain (≥3 months) with a severity of at least 3 on the Numerical Rating Scale (NRS).\n\nExclusion Criteria:\n\nIndividuals meeting any of the following criteria will be excluded from study participation:\n\n1. Inability to Consent: Unable to provide informed consent or not willing to participate in the study procedures.\n2. Severe Sensory or Motion Limitations: Including severe visual or vestibular impairments that could increase the risk of falling.\n3. Communication Barriers: Significant hearing, speech, or language problems that would hinder communication with study personnel.\n4. Independent Walking Inability: Cannot walk independently without the aid of a walking device.\n5. Other Significant Diseases or Conditions:\n\n   * Neurological disorders that affect walking ability (e.g., stroke, Parkinson's disease).\n   * Orthopedic or musculoskeletal conditions severely affecting lower limb function.\n   * Severe cardiovascular conditions including uncontrolled hypertension or heart failure.\n   * Respiratory diseases requiring regular oxygen therapy.\n   * Active cancer treatment or cancer treatment within the past 3 years (except basal cell carcinoma or localized prostate cancer).\n   * Severe psychiatric disorders like schizophrenia or bipolar disorder.\n6. Other Exclusionary Factors:\n\n   * Past severe orthopedic surgeries on lower limbs which might affect gait and mobility.\n   * Severe back pain or any other condition affecting mobility not already listed.","ALL","65 Years",{"count":145,"type":146},30,"ESTIMATED","INTERVENTIONAL",[84],"This pilot clinical trial aims to evaluate the safety and feasibility of an integrated fabric-type orthosis with muscle-mimicking and proprioception-enhancing functions in older adults with geriatric conditions affecting gait and balance. The wearable orthosis provides lower-limb assistance through a fabric-based actuation system and vibrotactile proprioceptive stimulation. Thirty participants aged 65 years or older will undergo gait, balance, proprioception, and electromyography assessments under three conditions: without the orthosis, with the orthosis powered off, and with the orthosis powered on. Outcome measures include gait performance, postural sway, one-leg standing balance, joint position sense, muscle activation, physiological responses, fatigue, and device-related adverse events. The study is designed as an exploratory pilot trial to assess the clinical applicability, usability, and safety of the wearable assistive device in geriatric patients.",[151,152,153,154,155],"Sarcopenia","Older Adults (65 Years and Older)","Gait Analysis","Balance","Orthotic Device","2026-11-12",{"date":158,"type":159},"2026-11-18","ACTUAL",{"date":161,"type":159},"2026-06-17",{"date":163,"type":146},"2027-12-31",{"name":5,"class":6},1]