[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100664294":3},{"organization":4,"outcomesModule":7,"designInfo":14,"detailedDescription":21,"studyPopulation":13,"armGroups":22,"interventions":29,"overallOfficials":35,"centralContacts":40,"locations":13,"responsibleParty":49,"collaborators":13,"id":52,"slug":53,"hasResults":54,"nctId":55,"briefTitle":56,"officialTitle":57,"acronym":13,"eligibilityCriteria":58,"healthyVolunteers":54,"sex":59,"minAge":60,"maxAge":13,"enrollmentInfo":61,"targetDuration":13,"studyType":64,"phases":65,"briefSummary":66,"conditions":67,"keywords":13,"overallStatus":70,"whyStopped":13,"lastUpdateSubmitDate":71,"lastUpdatePostDateStruct":72,"startDateStruct":75,"completionDateStruct":77,"leadSponsor":79,"locationsCount":13},{"fullName":5,"class":6},"Atlantic Health System","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":13},[9],{"measure":10,"description":11,"timeFrame":12},"Number of Participants Achieving Hemostasis Without Alternative Nasal Packing or Balloon Tamponade","Hemostasis is defined as cessation of active bleeding after placement and inflation of the JStop™ Hemostatic Device, without the need for alternative nasal packing or balloon tamponade, as assessed by the treating emergency physician.","Within 10 minutes of device placement",null,{"allocation":15,"interventionModel":16,"interventionModelDescription":17,"primaryPurpose":18,"observationalModel":13,"timePerspective":13,"maskingInfo":19},"NA","SINGLE_GROUP","Prospective, single-arm, single-site pilot feasibility study. All participants receive the JStop™ Hemostatic Device. There is no control or comparator group.","TREATMENT",{"masking":20,"maskingDescription":13,"whoMasked":13},"NONE","Epistaxis is a common emergency department presentation. Moderate to severe cases often require mechanical tamponade with nasal packing, Foley catheters, or commercially available balloon devices, which can be uncomfortable, technically challenging, and sometimes ineffective, occasionally requiring repeated attempts or specialist consultation.\n\nThe JStop™ Hemostatic Device is a mechanical intranasal tamponade device intended to provide temporary hemostasis while potentially simplifying placement and improving patient tolerance. The device is considered a Non-Significant Risk (NSR) device under 21 CFR 812.3(m).\n\nThis is a prospective, single-arm, single-site pilot feasibility study at Morristown Medical Center (Atlantic Health System). Approximately 50 adults (18 years or older) presenting to the emergency department with epistaxis requiring nasal packing or mechanical tamponade, and able to provide written informed consent, will be enrolled. The treating emergency physician will place the JStop device according to its Instructions for Use. If the device fails to control bleeding or if clinically indicated, it will be removed and standard of care treatment provided immediately.\n\nProcedural data collected include time from insertion to inflation completion, time to hemostasis, total inflation volume, need for repositioning, and immediate device success or failure. Participants will be evaluated approximately 2 to 4 days after placement and contacted by telephone at one month.\n\nThe primary outcome is achievement of hemostasis without the need for alternative nasal packing or balloon tamponade within 10 minutes of device placement. Secondary outcomes include device-related adverse events, need for additional interventions, device failure, time to hemostasis, pain scores (0 to 10) at insertion, inflation, and while in place, physician-rated ease of placement (5-point Likert scale), device stability, rebleeding within 24 hours and 7 days, ease of removal and bleeding on removal, and investigator confidence in the device as first-line treatment.\n\nAnalyses will be descriptive, with success rates reported as proportions with exact confidence intervals. No formal hypothesis testing is planned given the pilot design.",[23],{"label":24,"type":25,"description":26,"interventionNames":27},"JStop™ Hemostatic Device","EXPERIMENTAL","Adults presenting to the emergency department with epistaxis requiring nasal packing or mechanical tamponade receive the JStop™ Hemostatic Device.",[28],"Device: Intranasal balloon tamponade device",[30],{"type":31,"name":32,"description":33,"armGroupLabels":34,"otherNames":13},"DEVICE","Intranasal balloon tamponade device","The JStop™ Hemostatic Device is a mechanical intranasal balloon tamponade device (Class I, 510(k)-exempt) placed and inflated by the treating emergency physician according to its Instructions for Use to provide temporary hemostasis in adults with epistaxis. If bleeding is not controlled, the device is removed and standard of care treatment is provided.",[24],[36],{"name":37,"affiliation":38,"role":39},"Tanveer Janjua, MD","Atlantic Health System (Morristown Medical Center)","PRINCIPAL_INVESTIGATOR",[41,45],{"name":37,"role":42,"phone":43,"phoneExt":13,"email":44},"CONTACT","9082689350","facialplastics@outlook.com",{"name":46,"role":42,"phone":47,"phoneExt":13,"email":48},"Cosimo Laterza","MD","cosimo.laterza@atlantichealth.org",{"type":39,"investigatorFullName":50,"investigatorTitle":51,"investigatorAffiliation":5,"oldNameTitle":13,"oldOrganization":13},"Tanveer Janjua","Physician","100664294","safety-and-feasibility-of-the-jstop-hemostatic-device-for-nosebleeds-in-the-emergency-department-100664294",false,"NCT07928739","Safety and Feasibility of the JStop™ Hemostatic Device for Nosebleeds in the Emergency Department","A Prospective Pilot Study Evaluating the Safety and Feasibility of the JStop™ Hemostatic Device in Patients With Epistaxis","Inclusion Criteria:\n\n* Inclusion Criteria:\n\n  1. Adults aged 18 years or older.\n  2. Presentation to the emergency department with epistaxis requiring nasal packing or mechanical tamponade as determined by the treating physician.\n  3. Ability to understand the study procedures and provide written informed consent.\n  4. Willingness to comply with study procedures and follow-up requirements.\n\nExclusion Criteria:\n\n1. Inability to provide informed consent.\n2. Known or suspected nasal or facial trauma, skull base fracture, or anatomical abnormality that would make device placement unsafe.\n3. Known hypersensitivity or allergy to materials used in the study device.\n4. Hemodynamic instability or medical condition requiring immediate life-saving intervention.\n5. Active nasal or sinus infection that, in the judgment of the treating physician, would increase risk of complications.\n6. Any condition that, in the opinion of the investigator, would make participation unsafe or interfere with study evaluation.\n7. Members of a vulnerable population category.","ALL","18 Years",{"count":62,"type":63},50,"ESTIMATED","INTERVENTIONAL",[15],"This study is testing whether the JStop™ Hemostatic Device can safely and quickly stop moderate to severe nosebleeds (epistaxis) in adults treated in the emergency department. JStop is a balloon device placed in the nose that applies gentle pressure to stop bleeding, similar to nasal packing and balloon devices already in use.\n\nAbout 50 adults who come to the Morristown Medical Center Emergency Department with a nosebleed that needs nasal packing will be treated with JStop. The main question is whether the device stops the bleeding within 10 minutes without the need for other packing. The study will also look at side effects, pain, how easy the device is to place and remove, and whether bleeding comes back. Participants will be seen 2 to 4 days after treatment and called at one month to check on their recovery.",[68,69],"Epistaxis","Nosebleed (Epistaxis) - Posterior or Anterior","NOT_YET_RECRUITING","2026-11-04",{"date":73,"type":74},"2026-11-10","ACTUAL",{"date":76,"type":63},"2027-01-01",{"date":78,"type":63},"2028-01",{"name":5,"class":6}]