[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100665832":3},{"organization":4,"outcomesModule":7,"designInfo":24,"detailedDescription":27,"studyPopulation":28,"armGroups":29,"interventions":35,"overallOfficials":41,"centralContacts":45,"locations":51,"responsibleParty":66,"collaborators":68,"id":72,"slug":73,"hasResults":74,"nctId":75,"briefTitle":76,"officialTitle":77,"acronym":23,"eligibilityCriteria":78,"healthyVolunteers":74,"sex":79,"minAge":80,"maxAge":81,"enrollmentInfo":82,"targetDuration":85,"studyType":86,"phases":23,"briefSummary":87,"conditions":88,"keywords":92,"overallStatus":53,"whyStopped":23,"lastUpdateSubmitDate":97,"lastUpdatePostDateStruct":98,"startDateStruct":101,"completionDateStruct":103,"leadSponsor":105,"locationsCount":106},{"fullName":5,"class":6},"Chungnam National University Hospital","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":23},[9],{"measure":10,"description":11,"timeFrame":12},"Area under the receiver operating characteristic curve (AUC) of the pre-dialysis T-wave morphology index for discriminating hyperkalemia","Hyperkalemia is defined as pre-dialysis serum potassium greater than 5.0 mEq\u002FL. The prespecified T-wave morphology index (T-wave slope-to-amplitude ratio) is calculated from the six-channel wearable electrocardiogram (ECG) recorded immediately before dialysis. AUC is estimated from a mixed-effects logistic regression model with a random effect for participant; the 95% confidence interval is obtained by participant-level bootstrap.","At each monthly dialysis session for 6 months (6 sessions per participant)",[14,17,20],{"measure":15,"description":16,"timeFrame":12},"Within-participant correlation between the T-wave morphology index and serum potassium concentration","Estimated from a linear mixed-effects model separating between- and within-participant associations, using pre- and post-dialysis measurements.",{"measure":18,"description":19,"timeFrame":12},"Mean absolute error of electrocardiogram (ECG)-estimated serum potassium","Mean absolute error (mEq\u002FL) between ECG-based estimated potassium and laboratory serum potassium, with participant-level cross-validation.",{"measure":21,"description":22,"timeFrame":12},"Within-participant correlation between change in serum potassium and change in electrocardiogram (ECG) indices during dialysis","Repeated-measures correlation between the pre- to post-dialysis change in serum potassium (mEq\u002FL) and the corresponding change in ECG waveform indices within the same session.",null,{"allocation":23,"interventionModel":23,"interventionModelDescription":23,"primaryPurpose":23,"observationalModel":25,"timePerspective":26,"maskingInfo":23},"COHORT","PROSPECTIVE","Patients on maintenance hemodialysis accumulate potassium between sessions, and hyperkalemia can cause conduction delay, bradycardia, ventricular arrhythmia, and cardiac arrest, often without symptoms. Routine monitoring relies on monthly venous blood sampling and cannot capture changes between tests. Previous studies have shown that T-wave morphology on the electrocardiogram (ECG) correlates with serum potassium, but most wearable studies have used single-lead signals.\n\nThe investigators previously conducted a pilot study (NCT07054905) in 32 hemodialysis patients using a single-lead wearable ECG patch over 6 weeks with pre-dialysis potassium only. The present study extends that design in three ways: (1) a wearable device that records six ECG channels from three chest electrodes, (2) a longer observation period of 6 months with one measurement session per month (6 sessions per participant), and (3) measurement of post-dialysis potassium, calcium, and phosphate in addition to pre-dialysis laboratory tests, so that ECG changes can be related to the large electrolyte shift within a single dialysis session.\n\nAt each monthly session, scheduled on the day of the routine monthly blood test, the device is attached immediately before dialysis, records continuously throughout dialysis, and is removed at the end of the session. Pre-dialysis laboratory values are taken from routine monthly tests. Post-dialysis potassium, calcium, and phosphate are measured in the blood sample routinely drawn for dialysis adequacy assessment. Dialysis prescription, intradialytic blood pressure, body weight, medication changes, and skin condition at the attachment site are recorded at each session. Dialysis prescriptions and medications are determined by the treating physicians and are not specified by the study.\n\nECG waveform indices (including T-wave amplitude, slope, slope-to-amplitude ratio, QRS duration, QT and corrected QT intervals, PR interval, and P-wave amplitude) are calculated for each channel. The primary analysis evaluates discrimination of pre-dialysis hyperkalemia using mixed-effects logistic regression with a random effect for participant, with confidence intervals obtained by participant-level bootstrap. Secondary analyses use linear mixed-effects models and repeated-measures correlation to estimate within-participant associations. The study is exploratory; the sample size of 40 participants (240 sessions) was chosen based on prior studies of similar design, expected precision of the primary estimate, and feasibility. Results will provide effect size and intraclass correlation estimates for planning a subsequent multicenter confirmatory study.","Adults with end-stage kidney disease receiving maintenance hemodialysis at the hemodialysis unit of Chungnam National University Hospital, Daejeon, Republic of Korea.",[30],{"label":31,"type":23,"description":32,"interventionNames":33},"Maintenance hemodialysis patients","Adults receiving thrice-weekly maintenance hemodialysis at a single center who wear a six-channel wearable electrocardiogram (ECG) patch during one dialysis session per month for 6 months.",[34],"Device: Six-channel wearable electrocardiogram (ECG) patch (SHC-U8)",[36],{"type":37,"name":38,"description":39,"armGroupLabels":40,"otherNames":23},"DEVICE","Six-channel wearable electrocardiogram (ECG) patch (SHC-U8)","A wearable Holter-type ECG recorder (model SHC-U8, Solmitech Co., Ltd., Republic of Korea) that records six ECG channels from three chest electrodes. The device is attached immediately before dialysis and removed at the end of the session, once per month for 6 months. It is used within its approved indication for ECG recording only; no treatment is assigned.",[31],[42],{"name":43,"affiliation":5,"role":44},"Dae Eun Choi","PRINCIPAL_INVESTIGATOR",[46],{"name":47,"role":48,"phone":49,"phoneExt":23,"email":50},"Kyungho Park, MD","CONTACT","82-42-280-7235","ds3ixc@gmail.com",[52],{"facility":5,"status":53,"city":54,"state":55,"zip":56,"country":57,"countryCode":23,"cosmosGeoPoint":58,"geoPoint":63,"contacts":64},"RECRUITING","Daejeon","DJ","34955","South Korea",{"type":59,"coordinates":60},"Point",[61,62],127.3848,36.35022,{"lat":62,"lon":61},[65],{"name":47,"role":48,"phone":49,"phoneExt":23,"email":50},{"type":67,"investigatorFullName":23,"investigatorTitle":23,"investigatorAffiliation":23,"oldNameTitle":23,"oldOrganization":23},"SPONSOR",[69],{"name":70,"class":71},"Korea Health Industry Development Institute","OTHER_GOV","100665832","six-channel-wearable-ecg-for-prediction-of-hyperkalemia-in-hemodialysis-patients-100665832",false,"NCT07947485","Six-Channel Wearable Electrocardiogram for Prediction of Hyperkalemia in Hemodialysis Patients","Prediction of Hyperkalemia in Hemodialysis Patients Through Waveform Analysis Using a Six-Channel Wearable Electrocardiogram","Inclusion Criteria:\n\n* Age 19 to 79 years\n* Receiving hemodialysis three times per week and clinically stable without acute complications for the past 3 months\n* Able to understand the purpose and procedures of the study and provide written informed consent\n* No physical or physiological condition that prevents electrocardiogram (ECG) measurement\n* Expected to continue maintenance hemodialysis at the study site for the 6-month participation period\n\nExclusion Criteria:\n\n* Chest skin condition that prevents or may be aggravated by device attachment (for example, severe dermatitis, burn, surgical wound, or infection at the attachment site)\n* Permanent pacemaker, implantable cardioverter-defibrillator, or cardiac resynchronization therapy device\n* Pregnant or breastfeeding\n* Planned kidney transplantation, conversion to peritoneal dialysis, or transfer to another facility during the study period\n* Lack of capacity to provide informed consent, including cognitive impairment\n* Any other condition that the principal investigator considers inappropriate for participation","ALL","19 Years","79 Years",{"count":83,"type":84},40,"ESTIMATED","6 Months","OBSERVATIONAL","Hyperkalemia is a common and potentially fatal electrolyte disorder in patients receiving maintenance hemodialysis, but it is currently detected only by periodic blood tests. This prospective, single-center observational cohort study will evaluate whether T-wave morphology measured with a six-channel wearable electrocardiogram (ECG) patch can identify hyperkalemia (serum potassium greater than 5.0 mEq\u002FL) in these patients. Forty adults on thrice-weekly hemodialysis will wear the device during one dialysis session per month for 6 months. ECG recordings will be compared with serum potassium measured before and after the same dialysis session. No treatment is assigned by the study, and no additional blood draws are required.",[89,90,91],"Hyperkalemia","End-Stage Kidney Disease (ESKD)","Hemodialysis",[93,94,95,96],"wearable electrocardiography","T wave","serum potassium","digital health","2026-11-23",{"date":99,"type":100},"2026-11-27","ACTUAL",{"date":102,"type":100},"2026-11-12",{"date":104,"type":84},"2027-11-30",{"name":5,"class":6},1]