[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100662184":3},{"organization":4,"outcomesModule":7,"designInfo":32,"detailedDescription":38,"studyPopulation":31,"armGroups":39,"interventions":52,"overallOfficials":31,"centralContacts":61,"locations":31,"responsibleParty":68,"collaborators":31,"id":70,"slug":71,"hasResults":72,"nctId":73,"briefTitle":74,"officialTitle":75,"acronym":31,"eligibilityCriteria":76,"healthyVolunteers":77,"sex":78,"minAge":79,"maxAge":31,"enrollmentInfo":80,"targetDuration":31,"studyType":83,"phases":84,"briefSummary":86,"conditions":87,"keywords":31,"overallStatus":89,"whyStopped":31,"lastUpdateSubmitDate":90,"lastUpdatePostDateStruct":91,"startDateStruct":94,"completionDateStruct":96,"leadSponsor":98,"locationsCount":31},{"fullName":5,"class":6},"University of Malaya","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":20,"otherOutcomes":31},[9,13,17],{"measure":10,"description":11,"timeFrame":12},"Rating of Perceived Exertion During Walking Sessions","Participants will rate their perceived physical effort after each planned walking session using a 10-point Rating of Perceived Exertion scale. Scores range from 1 to 10, where 1 indicates very light effort and 10 indicates maximal perceived effort. Higher scores indicate greater perceived exertion and may indicate lower exercise tolerance or a need to pause, repeat, or simplify the current walking plan.","Week 1 through Week 12",{"measure":14,"description":15,"timeFrame":16},"Smart-Sock and Mobile-Application Data Completeness","Percentage of expected device and application data records available for analysis. Scores range from 0% to 100%; higher percentages indicate better data completeness.","Baseline through Week 12",{"measure":18,"description":19,"timeFrame":16},"Safety Events","Number of reported falls, near-falls, warning symptoms, device discomfort events, battery\u002Fcharging concerns, and technical faults. Lower numbers indicate better safety and technical acceptability.",[21,25,28],{"measure":22,"description":23,"timeFrame":24},"Six-Minute Walk Test Distance","Distance walked during the Six-Minute Walk Test, measured in meters. Higher distance indicates better walking endurance.","Baseline, Week 6, and Week 12",{"measure":26,"description":27,"timeFrame":24},"Timed Up and Go Test Time","Time required to stand from a chair, walk 3 meters, turn, walk back, and sit down, measured in seconds. Lower time indicates better functional mobility.",{"measure":29,"description":30,"timeFrame":24},"30-Second Chair Stand Test Repetitions","Percentage of planned walking sessions completed during the intervention. Scores range from 0% to 100%; higher percentages indicate better adherence.",null,{"allocation":33,"interventionModel":34,"interventionModelDescription":31,"primaryPurpose":35,"observationalModel":31,"timePerspective":31,"maskingInfo":36},"RANDOMIZED","PARALLEL","PREVENTION",{"masking":37,"maskingDescription":31,"whoMasked":31},"NONE","This study evaluates a low-cost, foot-worn sensing prototype and mobile application intended to support gradual walking activity in older adults. Many commercially available activity tools provide step counts or fixed goals but do not combine simple foot-level movement information, perceived effort, symptom reporting, and conservative progression rules. The proposed system is designed to explore whether a simpler and more accessible approach can be implemented reliably in community-dwelling older adults.\n\nThe smart sock is a removable research prototype used with ordinary footwear. Its sensing module combines an FSR402 force-sensitive resistor placed beneath the forefoot with the integrated inertial measurement unit in a Seeed Studio XIAO nRF52840 Sense board. The FSR402 is used to identify changes in foot contact, while the inertial sensor records patterns of acceleration and angular movement. These signals are used to derive step events, cadence, inter-step timing, and simple indicators of walking rhythm. The system is intended for activity monitoring and coaching only. It is not designed to diagnose disease, measure laboratory-grade plantar pressure, estimate oxygen consumption, predict falls, provide emergency alerts, or replace clinical assessment.\n\nThe prototype is built from readily available components to support reproducibility and low cost. It includes a protected 3.7-V lithium-polymer battery, a 3.3-kΩ 1\u002F4-W metal-film resistor, flexible insulated wire, a small green perforated FR-4 prototype printed circuit board, and a removable protective enclosure. The FSR402 and resistor form a 3.3-V voltage-divider circuit connected to the analog input of the XIAO board. The board uses Bluetooth Low Energy to send session summaries to the mobile application. The electronics are enclosed and positioned above the foot or near the shoe laces; the sensor sits beneath the removable insole at the forefoot. The battery is not charged while the device is worn or inside the shoe.\n\nThe mobile application is designed specifically for older adults. Its interface uses large high-contrast text, clear icons, plain-language prompts, minimal navigation, optional audio prompts, and a direct method to pause a session or report a symptom. Rather than showing complex sensor graphs, the application provides a small number of understandable messages about the current walking plan, session completion, perceived effort, and whether the current level should be maintained, reviewed for cautious progression, or paused.\n\nThe progression approach is intentionally conservative. The application does not advance activity after a single successful session. It considers repeated session completion, perceived exertion within the intended range, absence of a reported fall or warning symptom, and the absence of concerning changes in the derived walking indicators. When conditions are favorable, only one part of the walking plan is changed at a time, such as a small increase in walking duration or a reduction in a planned recovery period. A report of pain, dizziness, unusual shortness of breath, a fall, high perceived effort, device discomfort, or a concerning walking trend leads to pausing, repeating, simplifying, or reviewing the plan rather than automatic progression.\n\nThe application includes an optional participant-controlled family-support function. If a participant chooses this option, a trusted family member or helper may receive limited practical notifications, such as that a session was completed, paused, or that a check-in may be helpful. The support person cannot see raw sensor information, perceived-effort ratings, symptoms, health history, functional-assessment results, or the application's progression rule. They cannot change the participant's settings, override an alert, or make a progression decision. This feature is intended to support encouragement and practical assistance while preserving participant autonomy and privacy.\n\nThe study will document whether the hardware, software, instructions, and monitoring workflow can be delivered as planned and whether the system produces usable information for a later, appropriately powered effectiveness study. Technical assessment will focus on agreement of device-derived step events and cadence with reference observations. Implementation assessment will consider wearable fit, battery and charging performance, data transfer, technical faults, ease of setup, device comfort, accessibility of the application, and acceptability of optional family support. Information collected by the application will be limited to data necessary for monitoring and evaluation, including time-stamped step events or derived features, session information, perceived effort, symptom reports, app status, technical logs, and selected family-support preferences. Data will be handled through institutionally approved, secure procedures.",[40,46],{"label":41,"type":42,"description":43,"interventionNames":44},"Adaptive Smart Sock and Mobile Application","EXPERIMENTAL","Participants will use a low-cost smart sock and an older-adult mobile application for 12 weeks. The smart sock records step timing, cadence, and walking-rhythm indicators and sends session summaries to the app through Bluetooth Low Energy. The app provides an individual walking plan, session-completion prompts, rating of perceived exertion and symptom reporting, simple walking-trend feedback, conservative progression rules, and optional privacy-controlled family-support notifications. The system is not intended to diagnose disease, predict falls, provide emergency monitoring, or replace clinical assessment",[45],"Device: Low-Cost Smart Sock and Older-Adult Mobile Application",{"label":47,"type":48,"description":49,"interventionNames":50},"Standard Individual Walking Plan","ACTIVE_COMPARATOR","Participants will follow a standard, nonadaptive individual walking plan for 12 weeks. The plan includes the same broad recommended walking frequency, safety information, and scheduled study contact. Participants will complete the program independently and will not receive the smart sock, individualized mobile-app feedback, automated progression, or study-provided family support",[51],"Other: Standard Individual Walking Plan",[53,58],{"type":54,"name":55,"description":56,"armGroupLabels":57,"otherNames":31},"DEVICE","Low-Cost Smart Sock and Older-Adult Mobile Application","A low-cost foot-worn research prototype and mobile application for monitoring walking-related information and supporting gradual physical activity in adults aged 60 years and older. The device includes an FSR402 force-sensitive resistor, Seeed Studio XIAO nRF52840 Sense board with integrated motion sensor, protected 3.7-V lithium-polymer battery, and Bluetooth Low Energy connectivity. The application provides an individual walking plan, session completion prompts, perceived-exertion and symptom reporting, simple walking-trend feedback, conservative progression rules, and optional privacy-controlled family-support notifications. The system is not intended to diagnose disease, predict falls, provide emergency monitoring, or replace clinical assessment.",[41],{"type":6,"name":47,"description":59,"armGroupLabels":60,"otherNames":31},"A standard, nonadaptive individual walking plan with safety information and scheduled study contact. Participants complete the plan independently and do not receive the smart sock, individualized application feedback, automated progression, or study-provided family support.",[47],[62],{"name":63,"role":64,"phone":65,"phoneExt":66,"email":67},"Azari J Medhir, PhD","CONTACT","+60 199561806","+966 544152309","moh37471@gmail.com",{"type":69,"investigatorFullName":31,"investigatorTitle":31,"investigatorAffiliation":31,"oldNameTitle":31,"oldOrganization":31},"SPONSOR","100662184","smart-sock-for-monitoring-walking-and-supporting-physical-activity-in-older-adults-a-family-supported-feasibility-study-100662184",false,"NCT07902102","Smart Sock for Monitoring Walking and Supporting Physical Activity in Older Adults","Protocol for a Low-Cost Smart Sock for Monitoring Walking Function and Supporting Progressive Physical Activity in Older Adults: Hardware Construction and a Family-Supported Randomized Feasibility Study","Inclusion Criteria:\n\n* Aged 60 years or older.\n* Living in the community (not residing in an institutional care facility).\n* Able to walk independently, with or without a customary walking aid, when considered safe by the study team.\n* Insufficiently active or interested in improving regular walking activity.\n* Has a compatible smartphone or access to a study-supported smartphone.\n* Able to understand study instructions and use the application independently or with assistance from a participant-selected helper.\n* Able and willing to provide written informed consent.\n* Willing to wear the smart sock during planned sessions and complete study assessments and follow-up procedures.\n\nExclusion Criteria:\n\n* Chest pain during physical activity or at rest that has not been medically assessed.\n* Unexplained dizziness, fainting, or loss of consciousness.\n* Acute lower-limb injury, severe foot pain, or another condition that prevents safe walking.\n* Unstable medical condition or a condition for which gradual unsupervised walking progression is considered inappropriate.\n* A fall in the recent period that required medical attention, unless cleared by an appropriate health professional.\n* Severe cognitive, visual, hearing, or communication difficulty that prevents informed consent, understanding of safety instructions, or safe participation.\n* Any other condition identified during pre-exercise screening that requires medical review before increasing physical activity.",true,"ALL","60 Days",{"count":81,"type":82},5,"ESTIMATED","INTERVENTIONAL",[85],"NA","The goal of this randomized feasibility clinical trial is to learn whether a low-cost smart sock and mobile application can be used safely, reliably, and comfortably to support gradual walking activity in adults aged 60 years and older. The smart sock is a research prototype worn with the participant's usual footwear. It records simple walking information, such as step timing and walking rhythm, and sends a summary to a mobile application. The application provides an individual walking plan, asks about perceived effort and symptoms, and shows simple messages about whether the participant should continue, repeat the current level, or pause and seek review.\n\nThe study will include community-dwelling adults aged 60 years or older who can walk independently, with or without a usual walking aid when this is considered safe. This study does not diagnose medical conditions, predict falls, provide emergency monitoring, or replace medical care.\n\nThe main questions this study aims to answer are:\n\n* Can older adults use the smart sock and application comfortably and complete the planned walking sessions?\n* Does the smart sock record step events and walking cadence accurately enough for this type of monitoring?\n* Are the application instructions, safety messages, and optional family-support feature understandable and acceptable to older adults?\n* Can the study procedures be delivered safely, including device fitting, battery charging, walking progression, and reporting of symptoms or falls?\n* What changes are seen over 12 weeks in walking activity and supervised functional assessments?\n\nResearchers will compare a smart-sock-supported adaptive walking group with a comparison group receiving a standard individual walking plan. Participants will be assigned to one of the two groups by chance. The smart-sock group will use the device and app, which may adjust the walking plan conservatively when repeated sessions are completed at an acceptable effort and no safety concerns are reported. Participants in this group may choose a trusted family member or helper to receive limited notifications, such as \"session completed\" or \"please check in.\" Family members will not see sensor data, symptoms, health history, test results, or decisions about walking progression. The comparison group will follow a standard nonadaptive walking plan independently and will not receive the smart sock, individualized app feedback, or study-provided family support.\n\nParticipants will:\n\n* Complete screening, provide informed consent, and take part in a supervised baseline visit.\n* Complete walking-related assessments at baseline, Week 6, and Week 12, including a 6-minute walk test, Timed Up and Go test, and 30-second chair-stand test.\n* Follow an individual walking plan for 12 weeks, usually with three to five sessions per week.\n* In the smart-sock group, wear the smart sock during planned sessions and use the mobile application to record session completion, perceived effort, and any symptoms.\n* Report falls, near-falls, pain, dizziness, unusual shortness of breath, device discomfort, or technical problems.\n\nParticipants can stop a walking session at any time. The walking plan will not progress if there are warning symptoms, a fall, high perceived effort, concerning changes in walking information, or a decline at supervised reassessment. The study team may pause, simplify, or review the plan when needed.",[88],"Walking Mesh","NOT_YET_RECRUITING","2026-10-28",{"date":92,"type":93},"2026-11-02","ACTUAL",{"date":95,"type":82},"2027-01-01",{"date":97,"type":82},"2027-07-01",{"name":5,"class":6}]