[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100662805":3},{"organization":4,"outcomesModule":7,"designInfo":22,"detailedDescription":26,"studyPopulation":27,"armGroups":28,"interventions":34,"overallOfficials":23,"centralContacts":23,"locations":40,"responsibleParty":61,"collaborators":63,"id":66,"slug":67,"hasResults":68,"nctId":69,"briefTitle":70,"officialTitle":71,"acronym":23,"eligibilityCriteria":72,"healthyVolunteers":68,"sex":73,"minAge":74,"maxAge":23,"enrollmentInfo":75,"targetDuration":78,"studyType":79,"phases":23,"briefSummary":80,"conditions":81,"keywords":83,"overallStatus":43,"whyStopped":23,"lastUpdateSubmitDate":85,"lastUpdatePostDateStruct":86,"startDateStruct":89,"completionDateStruct":91,"leadSponsor":93,"locationsCount":94},{"fullName":5,"class":6},"American College of Cardiology","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":17},[9],{"measure":10,"description":11,"timeFrame":12},"30 Day Major Adverse Cardiac and Cerebrovascular Events","30 day major adverse cardiac and cerebrovascular events captured by the TVT registry.","30 days post procedure",[14],{"measure":15,"description":16,"timeFrame":12},"30 Day Outcomes","Proportion of patients who are alive at 30 days year without adverse events including stroke or transient ischemic attack (TIA), major vascular complications, valve related dysfunction requiring re-intervention, incident renal replacement therapy, life-threatening bleeding, and high-degree aortic valve (AV) block requiring permanent pacemaker implantation as captured by the TVT Registry",[18],{"measure":19,"description":20,"timeFrame":21},"5 year Outcomes","Outcomes beyond 30 days will be assessed up to five years following TAVR using administrative claims data that will capture the following events: stroke or transient ischemic attack (TIA), major vascular complications, valve related dysfunction requiring re-intervention, incident renal replacement therapy, life-threatening bleeding, and high-degree aortic valve (AV) block requiring permanent pacemaker implantation","5 years post procedure",{"allocation":23,"interventionModel":23,"interventionModelDescription":23,"primaryPurpose":23,"observationalModel":24,"timePerspective":25,"maskingInfo":23},null,"COHORT","PROSPECTIVE","The STS\u002FACC TVT Registry™ (TVT Registry) was designed to support a national surveillance system to assess the prevalence, demographics, management, and outcomes of patients receiving transcutaneous valve therapies. The purposes of the TVT Registry include: (i) collecting pertinent and standardized data elements from participating hospitals, health care providers and others that measure and assess the quality of care for patients receiving TVT; (ii) providing confidential periodic reports to participating hospitals, health care providers and others, to evaluate and improve the quality of care in these areas; (iii) permitting and fostering appropriate research based upon the data collected by means of the TVT Registry; and (iv) to serve as a scalable data infrastructure for pre and post market studies.\n\nThe TVT Registry was created under the leadership of cardiovascular experts using available ACC-AHA and STS guidelines, data elements and definitions, previous trial data elements, Valve Academic Research Consortium (VARC) and other evidentiary sources and with critical input from participating sites regarding the feasibility of implementation and the burden of data collection. The process for developing the core registry dataset follows an established methodology for creating clinical data standards. In short, experts constitute a multi-disciplinary committee charged with initially outlining a set of key quality metrics to measure and describe the quality of care, using existing clinical practice guidelines as a blueprint. Through the measure\u002Fmetric development process of specifying numerators and denominators, inclusion and exclusion criteria, a comprehensive set of data elements and definitions are created to capture the clinical characteristics, indications, procedural aspects and adverse outcomes of patients undergoing transcutaneous valve therapies. These data elements and definitions were then subjected to several phases of review and refinement, including public comment period, to gain consensus on the final data elements and definitions. Datasets are periodically revised to reflect current clinical practice and on-going scientific relevance.\n\nHospitals join the TVT Registry by agreeing to the terms of a specific contract that outlines the obligations of each party and the annual fees for participation. In addition, participating sites sign a Business Associate Agreement\u002FData Use Agreement with the American College of Cardiology Foundation (ACCF) and the The Society of Thoracic Surgeons (STS) as per the requirements of the Health Insurance Portability and Accountability Act of 1996 as amended (HIPAA). Patient-level data are submitted by participating hospitals to The Society of Thoracic Surgeons (STS) and American College of Cardiology Foundation's (ACCF) joint TVT Registry.\n\nThe data are collected retrospectively from existing medical records or concurrently in the normal course of treatment on patients who meet the inclusion criteria as outlined in the registry. Additional testing and contact with the patient outside the hospital episode of care is required for this registry at 30 days and optional at one year for follow up interview and physical examination. The physical examination is a routine portion of the care for these patients; the interview will consist of optional survey questions from the Kansas City Cardiomyopathy Questionnaire (KCCQ) as a Quality of Life (QOL) survey.\n\nAll registry data (in-hospital and follow-up) is captured by participating sites using an electronic data collection tool provided by the TVT Registry or using a certified software application that has been reviewed and certified as compliant with the transmission specifications established by the ACCF for the TVT Registry.\n\nProtected Health Information (PHI), such as social security number, is collected. Registry sites can opt out of transmitting direct identifiers to the National Cardiovascular Data Registry (NCDR), so inclusion of direct identifiers in the registry is at the discretion of the registry site. When using the NCDR web-based data collection tool, direct identifiers are entered but a partition between the data collection process and the data warehouse maintains the direct identifiers separate from the analysis datasets. The minimum level of PHI transmitted to the ACCF when a participant opts out of submitting direct identifiers meets the definition of a Limited Dataset as such term is defined by HIPAA.\n\nIn recognition of the importance of data quality to all of its registry products, and to ensure that data submitted to the NCDR are complete, consistent, and accurate, a Data Quality Program was formally established by the NCDR in 2004. Upon receipt of the TVT Registry data submission, the ACCF reviews the data electronically and reports back coding errors. Such electronic checks verify consistency and completeness and allow participants to have ample opportunity to submit data until it satisfies consistency and completion thresholds. The report produced from these data checks is called a Data Quality Report (DQR).\n\nThe DQR provides the participant with a confidential analysis of their data submission's completeness and is used by the participant to help prioritize data cleaning efforts and to assess the necessity for re-submission. Once the data meets the data quality thresholds, it may be included in aggregation for the participant's data and national comparison.\n\nThe NCDR understands the need to ensure the data submitted to the TVT Registry is accurate and has a national audit program whereas a random set of participants are selected for an audit to confirm the data submitted to the registry is consistent with data in the medical record or source documentation.","Patients 18 years or over on arrival at the facility undergoing transcatheter aortic valve replacement.\n\nStudy Population:\n\nAll facilities performing transcatheter aortic valve replacement with the appropriate infrastructure that includes but is not limited to:\n\n1. On-site structural heart interventional cardiology and cardiac surgery programs.\n2. A post-procedure intensive care unit with personnel experienced in managing patients who have undergone open-heart valve procedures.\n3. A continuous quality improvement process that assesses procedural outcomes and makes necessary programmatic adjustments to assure patient safety.",[29],{"label":30,"type":23,"description":31,"interventionNames":32},"Transcatheter Aortic Valve Replacement Patients","TAVR Patients Will include all patients 18 years or over who undergo Transcatheter Aortic Valve Replacement (TAVR) including patients with asymptomatic severe aortic stenosis. The sample size will include all patients entered into the TVT Registry.",[33],"Procedure: Transcatheter Aortic Valve Replacement",[35],{"type":36,"name":37,"description":38,"armGroupLabels":39,"otherNames":23},"PROCEDURE","Transcatheter Aortic Valve Replacement","Procedure: Transcatheter Aortic Valve Replacement\n\n• Minimal invasive implantation of a biological prothesis in Aortic Position",[30],[41],{"facility":42,"status":43,"city":44,"state":45,"zip":46,"country":47,"countryCode":48,"cosmosGeoPoint":49,"geoPoint":54,"contacts":55},"American College of Cardiology \u002F National Cardiovascular Data Registry","RECRUITING","Washington D.C.","District of Columbia","20037","United States","US",{"type":50,"coordinates":51},"Point",[52,53],-77.03637,38.89511,{"lat":53,"lon":52},[56],{"name":57,"role":58,"phone":59,"phoneExt":23,"email":60},"NCDR Product Support","CONTACT","1-800-257-4737","ncdr@acc.org",{"type":62,"investigatorFullName":23,"investigatorTitle":23,"investigatorAffiliation":23,"oldNameTitle":23,"oldOrganization":23},"SPONSOR",[64],{"name":65,"class":6},"The Society of Thoracic Surgeons","100662805","society-of-thoracic-surgeons-and-american-college-of-cardiology-transcatheter-valve-therapy-registry-stsacc-tvt-registry-registry-purpose-and-research-objective-100662805",false,"NCT07908355","Society of Thoracic Surgeons and American College of Cardiology Transcatheter Valve Therapy Registry (STS\u002FACC TVT Registry™): Registry Purpose and Research Objective","STS\u002FACC TVT Registry™","Inclusion Criteria:\n\n* Patients 18 years or over on arrival at the facility undergoing transcatheter aortic valve replacement.\n\nExclusion Criteria:\n\n\\-","ALL","18 Years",{"count":76,"type":77},50000,"ESTIMATED","3 Months","OBSERVATIONAL","The STS\u002FACC TVT Registry™ (TVT Registry), created by The Society of Thoracic Surgeons (STS) and the American College of Cardiology Foundation (ACCF), is a benchmarking tool designed to assess the prevalence, demographics, management, and outcomes of patients undergoing transcatheter aortic valve replacement (TAVR) procedure. Patient-level data will be submitted by participating hospitals to the TVT Registry via the American College of Cardiology Foundation's National Cardiovascular Data Registry (NCDR). The primary aims of the TVT Registry, are to optimize the outcomes and management of patients through the implementation of evidence-based guideline recommendations in clinical practice, facilitate efforts to improve the quality and safety for patients undergoing TAVR procedures, investigate novel quality improvement methods and provide risk-adjusted assessment of patients for comparison with nationwide NCDR data. The secondary purpose of the TVT Registry is to serve as a rich source of clinical data to support assessments of short- and long-term safety, comparative and cost effectiveness research, and as a scalable data infrastructure for pre and post market studies.",[82],"Aortic Valve Stenosis",[71,84],"TVT Registry","2026-10-27",{"date":87,"type":88},"2026-11-02","ACTUAL",{"date":90,"type":77},"2026-09",{"date":92,"type":77},"2036-01",{"name":5,"class":6},1]